Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC AZARA THAKURIAPARA AZARA ASSAM 781 017 | KAMRUP METRO | ASSAM | 781017 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹11.0 L+₹71,474 (6.97%)Rejected-Finance NAV PUKHARI ROAD MILLAN PALLY PO DIST TINSUKIA ASSAM 786 125 | TINSUKIA | DIBRUGARH | ASSAM | 786125 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹11.2 L+₹90,646 (8.83%)Rejected-Finance A T ROAD CHABUA NEAR ST LUKAS HOSPITAL PO CHABUA DIST DIBRUGARH ASSAM 786 184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹11.4 L+₹1.2 L (11.4%)Rejected-Finance MOHANBARI JEMES WARREN TINALI AIR PORT ROAD PO MOHANBARI ASSAM 786012 | DIBRUGARH | ASSAM | 786012 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹11.6 L+₹1.4 L (13.2%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
30 Aug 2021, 6:00 pmClosed
GE (AF) Chbaua
GE(AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUGARH, ASSAM-786102
MAINTENANCE AND REPAIR OF APFC PANEL, MCCBs AND MISC WORKS AT STN UNDER GE (AF) CHABUA
2021_MES_460665_2
333/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Chabua
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) CHABUA
₹20,000
Yes
8 Sept 2021
16 Aug 2021
1 Sept 2021
16 Aug 2021
30 Aug 2021
23 Aug 2021
16 Aug 2021 - 21 Aug 2021
Amount
Indoor type 200 KVAR APFC panel
Indoor type 150 KVAR APFC panel
Indoor type 80 KVAR APFC panel
Indoor type 70 KVAR APFC panel
Indoor type 50 KVAR APFC panel
Indoor type 30 KVAR APFC panel
S & F in repairs power factor improvement static condenser (capacitors) of required capacity, complete all as specified and directed.
Supply and fixing in repair power contactors 3 pole rating 25 Amps, with auxiliary contact 01 NO 01 NC complete all as specified and directed.
Supply and fixing in repair power contactors 3 pole rating 30 Amps, with auxiliary contact 01 NO 01 NC complete all as specified and directed.
Supply and fixing in repair power contactors 3 pole rating 30 Amps, with auxiliary contact 01 NO 01 NC complete all as specified and directed.
Supply and fixing in repair power contactors 3 pole rating 32 Amps, with auxiliary contact 01 NO 01 NC complete all as specified and directed.
Supply and fixing in repair power contactors 3 pole rating 55 Amps, with auxiliary contact 01 NO 01 NC complete all as specified and directed.
Supply and fixing in repair capacitor duty contactors 3 pole type MO C5 Amps, with auxiliary contact 01 NO complete all as specified and directed.
Supply and fixing in repair capacitor duty contactors 3 pole type MO C8.5 Amps, with auxiliary contact 01 NO complete all as specified and directed.
Supply and fixing in repair capacitor duty contactors 3 pole type MO C10 Amps, with auxiliary contact 01 NO complete all as specified and directed.
Supply and fixing in repair capacitor duty contactors 3 pole type MO C12.5 Amps, with auxiliary contact 01 NO complete all as specified and directed.
Supply and fixing in repair capacitor duty contactors 3 pole type MO C15 Amps, with auxiliary contact 01 NO complete all as specified and directed.
Supply and fixing in repair capacitor duty contactors 3 pole type MO C 20 Amps, with auxiliary contact 01 NO complete all as specified and directed.
Supply and fixing in repair capacitor duty contactors 3 pole type MO C 25 Amps, with auxiliary contact 01 NO complete all as specified and directed.
Supply and fixing, in repair of MCBs, TPN, 415 Volts, up to 40 Amps, C curve, 10 kA, complete all as specified and directed.
Supply and fixing, in repair of MCBs, TPN, 415 Volts, 63 Amps, C curve, 10 kA, complete all as specified and directed.
Supply and fixing, in repair detuned reactor, copper wound 440V, 50Hz of capacity 1 KVAR complete all as specified and directed.
Supply and fixing, in repair detuned reactor, copper wound 440V, 50Hz of capacity 2 KVAR complete all as specified and directed.
Supply and fixing, in repair detuned reactor, copper wound 440V, 50Hz of capacity 3 KVAR complete all as specified and directed.
Supply and fixing, in repair detuned reactor, copper wound 440V, 50Hz of capacity 4 KVAR complete all as specified and directed.
Supply and fixing, in repair detuned reactor, copper wound 440V, 50Hz of capacity 5 KVAR complete all as specified and directed.
Supply and fixing, in repair detuned reactor, copper wound 440V, 50Hz of capacity 10 KVAR complete all as specified and directed.
S & F in repairs APFC Relays with auto set function having steps 6 stage suitable for 415 Volts incl necessary connections all as directed.
S & F in repairs APFC Relays with auto set function having 8 stage suitable for 415 Volts incl necessary connections all as directed.
S & F in repairs APFC Relays with auto set function having 12 stage suitable for 415 Volts incl necessary connections all as directed.
S & F in repairs MCCB 3 pole, 415 volt 200 Amps with breaking capacity 35 kA, 415 V, 50 Hz, all as directed.
S & F in repairs MCCB 3 pole,415 volt 250 Amps with breaking capacity 35 kA, 415 V, 50 Hz, all as directed.
S & F in repairs MCCB 4 pole,415 volt 200 Amps with breaking capacity 35 kA, 415 V, 50 Hz, all as directed.
S & F in repairs MCCB 4 pole,415 volt 250 Amps with breaking capacity 35 kA, 415 V, 50 Hz, all as directed.
S & F in repairs MCCB 4 pole,415 volt 400 Amps with breaking capacity 35 kA, 415 V, 50 Hz, all as directed.
Supply and fixing in repair digital voltmeter, ranging from 0 to 500 Volts, including providing necessary electrical connections (to accommodate in panel board) complete all as directed.
Supply and fixing in repair digital ammeter, ranging from 0 to 400 Amps (with CT of suitable ratio), including providing necessary electrical connections (to accommodate in panel board) complete all as directed.
S & F in repairs Fuse holder & Fuse base suitable for Cylindrical / DIN fuse-links with suitable fuse links of capacity 63 Amps all as directed.
S & F in repairs HRC Fuse Links of capacity up to 63 Amp all as directed.
S & F in repairs Indicator Lamps (LED type) all as directed.
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminum conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminum lugs complete of size 25 Sqmm nominal cross section x3.5 core including taking down of old unserviceable cable complete all as directed.
All as per item 36 but Size 35 Sqmm X 3.5 core
All as per item 36 but Size 50 Sqmm X 3.5 core
All as per item 36 but Size 70 Sqmm X 3.5 core
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supply & Laying of Sub-Class B Brick, well burnt laid breadth-wise along the length of cable laid in Trenches over sand cushion laid for UG cable protection complete all as specified and as directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI strip 25 x 4mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3, including exc & earth work in any type of soil, disposal of soil, providing alternate layer of charcoal and common salt, construction of pcc earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B1 cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed at site. Note:- Main earth lead beyond 7.5 meter shall be measured and paid separately.
Schedule of Credit
M/s Pramillabh Construction
M/s Sashi Enterprise
M/S P.K.B.CONSTRUCTION
M/S P R SINGH AND SONS
FREEZCON
kabitaconstruction
M/s PRABIR ENTERPRISE
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .