| 1 | L1₹14.9 LAccepted-AOC VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹15.9 L+₹47,481 (3.08%)Rejected-Finance 84 B LOWER BURDWAN COMPOUND RANCHI 834001 JHARKHAND | RANCHI | JHARKHAND | 834001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹16.2 L+₹80,386 (5.21%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹16.6 L+₹1.1 L (7.43%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹17.1 L+₹1.7 L (10.8%)Rejected-Finance GALI NO 4 GAUSHALA ROAD VIKASH NAGAR RAMGARH CANTT RAMGARH JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
11 Feb 2021, 6:00 pmClosed
GE Dipatoli
GARRISON ENGINEER MILITARY ENGINEER SERVICES DIPATOLI CANTT P.O. HOTWAR RANCHI - 835217
REPAIR / REPLACEMENT OF WATER SUPPLY NETWORK IN SASF AND ASC FAMILY QTRS AT DIPATOLI MIL STATION.
2021_MES_412395_1
8000/1653/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
Dipatoli
Class E
Category a(ii)
7 documents required · 7 mandatory
₹500
Yes
GE Dipatoli
₹30,000
Yes
19 Feb 2021
14 Jan 2021
13 Feb 2021
14 Jan 2021
11 Feb 2021
28 Jan 2021
Amount
Excavation in trenches n. exc 1.5 m width and not exc 1.5 mtr in depth for laying/taking out of pipe in soft/loose soil complete all as specified and as directed.
Returning/filling in trenches including spreading, leveling, watering and well ramming in layer not exc 25 cm thick complete all as specified and as directed.
Removal of excavated surplus soil n. exc 50 m and depositing where directed at level n exc 1.5 m above the starting point complete all as specified and as directed.
Taking up or down 15mm bore steel tubing and connections including cleaning for refixing or remove to MES store complete all as specified and as directed.
Description all as per srl item No. 4 here in before but pipe 20mm dia complete all as specified and as directed.
Description all as per srl item No. 4 here in before but pipe 25mm dia complete all as specified and as directed.
Description all as per srl item No. 4 here in before but pipe 40mm dia complete all as specified and as directed.
Description all as per srl item No. 4 here in before but pipe 50mm dia complete all as specified and as directed. Note for Srl item No. 4 to 8:- Excavation and earth work shall be measured and paid seperately.
Refixing old steel tubing 15mm bore with necessary connections in old or new positions (laid in Trenches, walls, ceiling, floors etc) with necessary required including new fittings complete all as specified and as directed.
Description all as per srl item No. 9 here in before but pipe 20mm dia complete all as specified and as directed.
Description all as per srl item No. 9 here in before but pipe 25mm dia complete all as specified and as directed.
Description all as per srl item No. 9 here in before but pipe 40mm dia complete all as specified and as directed.
Description all as per srl item No. 9 here in before but pipe 50mm dia complete all as specified and as directed. Note for Srl item No. 9 to 13:- (a) Old GI pipe shall be retrived from Srl item No. 4 to 8. (b) GI fittings required shall be new and shall be provided by the Contractor. Unit quoted rate shall be deemed to be included the cost of new fittings.
S&F 15mm bore GI tubes medium grade galvanized with necessary fittings and clamps as per SSR Part -1, laid in trenches /wall/floors concealed or open execution complete all as specified and as directed.
Description all as per srl item No. 14 here in before but pipe 20mm dia complete all as specified and as directed.
Description all as per srl item No. 14 here in before but pipe 25mm dia complete all as specified and as directed.
Description all as per srl item No. 14 here in before but pipe 40mm dia complete all as specified and as directed.
Description all as per srl item No. 14 here in before but pipe 50mm dia complete all as specified and as directed.
S&F in repair 15mm dia stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe with unions and fixed complete with suitable size of fittings like unions, long screw with check nut for iron pipe complete all as specified and as directed.
Description all as per srl item No. 19 here in before but pipe 20mm dia complete all as specified and as directed.
Description all as per srl item No. 19 here in before but pipe 25mm dia complete all as specified and as directed.
S&F in repair 15mm bore gun metal globe or gate valve with iron wheel head, screwed both ends with union, long screw with check nut for iron pipe complete all as specified and as directed.
Description all as per srl item No. 22 here in before but pipe 20mm dia complete all as specified and as directed.
Description all as per srl item No. 22 here in before but pipe 25mm dia complete all as specified and as directed.
Description all as per srl item No. 22 here in before but pipe 40mm dia complete all as specified and as directed.
Description all as per srl item No. 22 here in before but pipe 50mm dia complete all as specified and as directed.
Taking up 80mm bore cast iron water mains including all fittings with spigot and socket ends and lead joint including burning out lead joint and recovering lead of CI pipe complete all as specified and as directed.
Description all as per srl item No. 27 here in before but pipe 100mm dia complete all as specified and as directed.
Description all as per srl item No. 27 here in before but pipe 150mm dia complete all as specified and as directed. Note of Srl item No. 27 to 29:- Excavation and earth work shall be measured and paid seperately.
Refixing of 80mm bore cast iron pipes with socket and spigot end in trenches with necessary new fittings in any length including cleaning of pipes complete all as specified and as directed.
Description all as per srl item No. 30 here in before but pipe 100mm dia complete all as specified and as directed.
Description all as per srl item No. 30 here in before but pipe 150mm dia complete all as specified and as directed. Note of Srl item No. 30 to 32:- Excavation and earth work shall be measured and paid seperately.
S&F 80mm bore ductile iron pipe with spigot and socket ends class k-7, suitable for Tyton joint in any length, laid in trenches complete all as specified and as directed.
Description all as per srl item No. 33 here in before but pipe 100mm dia complete all as specified and as directed.
Description all as per srl item No. 33 here in before but pipe 150mm dia complete all as specified and as directed. Note of Srl item No. 33 to 35:- Excavation and earth work shall be measured and paid seperately.
M&L in repair for run lead joints of CI pipes of 80mm bore complete all as specified and as directed.
Description all as per srl item No. 36 here in before but pipe 100mm dia complete all as specified and as directed.
Description all as per srl item No. 36 here in before but pipe 150mm dia complete all as specified and as directed.
Description all as per srl item No. 36 here in before but pipe 200mm dia complete all as specified and as directed.
M&L in repair for rubber gasket (Tyton) joint of 80mm dia complete all as specified and as directed.
Description all as per srl item No. 40 here in before but pipe 100mm dia complete all as specified and as directed.
Description all as per srl item No. 40 here in before but pipe 150mm dia complete all as specified and as directed.
M&L for drilling and tapping cast iron water mains in position for branch connections of 15mm bore dia complete all as specified and as directed.
S&F in repair bends ( any type radius and angles) tapers any type (straight bend, increasing, decreasing or double socket etc) tee pieces single branch Y junction, double, branches cross (all sockets or socket and spigot) collars caps and plugs suitable for socket and spigot type of any bore complete all as specified and as directed.
S&F in repair 15mm bore bib taps cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and as directed.
Cutting the existing leakage/broken CI pipe in position for upto 100mm bore and taking out the broken piece, with and including required excavation and earth work in any soil and fixing the new CI pipe and fittings with necessary joints complete all as dierected and shown by Engr-in-Charge. Note for srl item No. 46 & 47:- (a) CI pipe and fittings shall be measured & paid separately. (b) Lead/Tyton joints shall be measured & paid separately
Description all as per srl item No. 46 here in before but CI pipe of 150mm to 200mm dia complete all as specified and as directed.
S&F in repair 15mm bore ball valves high pressure of PTMTwith epoxy coated aluminium rod & high density plastic ball screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
Description all as per srl item No. 48 here in before but 20mm bore ball valve complete all as specified and as directed.
Description all as per srl item No. 48 here in before but 25mm bore ball valve complete all as specified and as directed.
S&F in replacement 80mm bore CI sluice valve confirming to IS 14846 – 2000, PN 1.0, flanged ends, stainless steel spindle with necessary packing materials and nut, bolts complete all as specified and as directed.
Description all as per srl item No. 51 here in before but 100mm dia size sluice valve complete all as specified and as directed.
united builders
M/S ALLIED MACHINERIES AND ENGINEERS
M/s Bawa Brothers
M/s Ray construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .