Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹20.5 L+₹77,021 (3.90%)Rejected-Finance | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹21.3 L+₹1.5 L (7.84%)Rejected-Finance | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹23.8 L+₹4 L (20.2%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹41,100
Closing Date
12 Sept 2024, 6:00 pmClosed
GE Jaipur
GE Jaipur
ROOF TREATMENT AND SPL REPAIRS IN QUARTER NO 02 , 03 AND 04 AT CSD DEPOT JAIPUR
2024_MES_665834_1
GE/J- /2024-25
Open Tender
Civil Works
Item Rate
180 days
GE Jaipur
As per Tender Documents
5 documents required · 5 mandatory
₹500
Yes
GE Jaipur
₹41,100
Yes
22 Nov 2024
13 Jul 2024
14 Sept 2024
13 Jul 2024
12 Sept 2024
27 Jul 2024
Amount
B/R Portion Taking down existing roof treatment complete including demolition of PCC, Mud phuskas, lime concrete etc any description upto 200mm thick, and properly cleaning the surface to remove loose particles with wire brushes and removing the debris out side of MoD land complete all as specified and as directed by Eng- In-Charge.
M&L for surface preparation by removal of all loose particle to ensure clean, smooth and dry surface and laying 25mm thick PCC type B-0, (1:2:4) using 12.5 mm graded stone aggregate finished even & smooth without using extra cement to cover negative slope into prop with mixing of WPC @ 3% weight of cement complete all as specified and directed. Note : WPC shall be measured and paid seperately
Supply only integral water proofing compund omplete all as specified and directed.
M&L for screed plaster 15 mm thick in CM 1:4 on roof surface complete and finished the surface even and fiar without using extra cement etc. to receive water proofing treatment complete all as specified and directed
The surface shall be painted with one coat of polymeric primer @ 0.40 kg per sqm conforming to IS: 3384 and a coat of bitumen grade 30/40 @ 1.20 kg/ Sqm below the layer of APP based polymeric memberance.( 3 mm thick minimum weight not less 150 gms ) and Side over lap shall be 75 mm and ends shall be 100 mm and all over lap and joints insert upto thr ht 150 cm vertical surface imbeded in wall and finifhing in CM 1:3 , embeding membrane into spout pipe , roof down ward facia and shall sealed by torch application with bitumen 30/40 grade, coved filled in PCC (1:2:4) type B-0 of radious 75 mm at roof junction,parapet wall and other vertical surface complete all as specified Applicatiion of polymeric memberance shall be torch application all as per manufacturer instructions. Note : The work shall be carried through authorized applicator
M&L preparation of APP based polymeric surface and applying two coat of aluminium paint all as specified & as directed.
S & F steel work in tubular trusses including special shaped washer etc, complete using ERW or induction butt welded tubes conforiming to IS 1161-1979 grade St-240 complete all as specified and as directed.
M & L Dismantling/ chipping of unsound weak/ loose & cracked concrete/ cement plaster as in soffits of chajjas, ceillings , roof projection, cleaning the rusted reinforcement and exposed surface by wire brush, mechanical device or any other established method and applying the rust removing solution of approved make and quality with cotton swab to reinforcement and allowing to dry the same for 24 hrs, brushing of loose particles and applying 1st coat of rust preventive coating and applying applying bond coat of epoxy bonding agent & Cement in 1:1 ratio for bondig old and new concrete on damaged surfaces and applying polymer modified mortar in CM (1:3) having 20 mm Avg thickness Note :- (a) Repairs to be done by authorised applicator of Dr Fixit/ Build Core/Fosroc/Pedilite as approved by GE. (b) (i) Quanitiy of polymer shall be 15% by weight of cement. (ii) Pan mixer shall be used to get homogenous dough on bond coat surfaces. (iii) Required thickness shall be achieved by repeating this step after 24 Hrs to as required. (iv) Repaired surfaces area shall be kept moist for 5-7 days.
M&L Mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape requried, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
,---ditto--- all as per item No 9 but 10 mm dia & over complete all as specified and directed
Taking down cement plaster any description on brick or stone walls, etc. including raking out joints, hacking for key & scrubbing down with water, etc. & removing rubbish outside MD land complete all as directed.
M & L prepartation of new plastered surfaces and applying two coats of oil bound distemper on ceiling complete all as directed.
M&L for rendering 10mm thick on fair faces of conc. surfaces of ceiling in cement mortar 1:3 finished even and smooth w/o using extra cement complete all as specified and directted.
M&L for rendering 15mm thick cement plaster in CM 1:4 on fair faces of brick work or concrete surfaces and finishing the surface even and smooth (without using extra cement) complete all as specified and directted.
M/L rendering 15 mm thick on stone masonry surfaces or other than fair faces of brick surfaces in CM(1:6) finished even and smooth with out using extra cement complete all as specified and directted.
M&L for preparation of new surfaces of wall and applying two coat of oil bound distemper over and incl one coat of primer complete all as specified and as directed.
M&L preparation of new plastered surface and applying two coats of acrylic emulsion weather proof paint in plains, patterns on walls over and incl a coat of primer of any tint all approve by EIC complete all as specified and directed.
M & L complete removal of existing treatment of old plastered surfaces of ceiling and applying two coats of oil bound distemper complete all as directed.
S&F complete removal of existing treatment of old plastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over and incl a coat of primer complete all as specified and directed
S&F complete removal of existing treatment of walls by mechanical means and applying two coat of Exterior acrylic emulsion weather proof paint over a coat of alkali resistant primer on walls complete all as specified.
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic tiles 7 to 8 mm thick, coloured (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match bedded over and incl 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L Non - skid joint free Ceramic tiles 7 to8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical surfaces such as skirtings and dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl backing coat 10 mm thick in CM (1:4) complete all as specified and directed.
M&L digital coloured glazed ceramic tiles 300x450x7mm thick in vertical surfaces such as skirting and dados set and jointed in neat cement slurry pointed in coloured cement to match incl backing coat 10 mm thick in CM (1:4) complete all as specified and directed.
M&L for non skid joint free coloured ceramic matching tiles 7 to 8mm thick (square / rectangular )area of each tiles exc 0.11 sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match bedded over and incl 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
S & F in repair GI tubing medium grade with all fitting 15 mm bore fixed to wall or concealed or fitted to ceiling or laid under floor incl taking down complete all as specified and directed.
S & F in repair GI tubing medium grade with all fitting 20 mm bore fixed to wall or concealed or fitted to ceiling or laid under floor incl taking down complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and ctting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed.
S&F as in repairs 15mm bore bib tap, fancy type, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F as in repairs 15mm bore cast copper alloy CP stop cock /angle cock fancy type screwed down with iron pipe or for union fixed complete all as specified and directed.
S&F in repair 15mm dia CP pillar taps cast copper alloy with capstan head, chromium plated, fancy type, screwed down high pressure with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair brass chromium plated shower rose 125mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and directed.
S & F in repair wall mixer CP for mixing hot & cold water, 15mm bore with L-bend pipe for connection to overhead shower, bright finish with three joints screwed the ends for iron pipe and plugging complete all as specified and directed.
Supply & fix as in repairs water storage tanks 500 litres capacity, rotational moulded, double layer polythene (cylindrical vertical with closed top) hoisting and fixed in position on roofs incl dismantling complete all as specified.
S & F in repair plate rack of size 750mmx600mmx250mm fabricated out of 0.6mm thick stainless steel sheet and fixed with chromium plated brass screws complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets fixed in any position with screws / nails complete all as specified and directed.
S & F 18 mm thick HDHMR (High density high moisture resistant) board of one side white laminate and other side decorative as in kitchen cabinets fixed with minifix hardware where ever required including edge band 22 mm wide 0.80 m thick of matching colour on exposed surfaces of board fixed with polymaster adhessive of REHAU make or equivalent including trimming edges of edge band to true line of thicknesss of board by manual trimmer complete all as directed
S & F 8 mm thick HDHMR (High density high moisture resistant) board of one side white laminate and other side un decorative as in back of kitchen cabinets complete all as specified and directed.
S & F auto close hinges, stainless steel of grade SS-304 , bright finish fixed complete all as specified. Make : Godrej, Hindware, Lifetime
S & F stainless steel handles of size 100 mm fancy type of approved make complete all as specified & directed. Make : Godrej, Hindware, Lifetime
Supply & fix in repairs 25mm dia stainless steel curtain rod powder coated with fixing side brackets, end cups and fixed with PVC rawl plugs & steel screws complete all as specified and directed.
S &F in repairs tubular towel rail, 20mm dia, 600mm long of brass chromium plated, fixed with brackets and including chromium plated brass screws and wooden/plastic cleats complete all as specified.
S &F in repairs Wash hand basin, flat back 550 x 400mm vitreous china (white) including chromium plated waste fittings, 32mm bore, 65mm long waste pipe of PVC & making good disturbed surfaces to match with the existing complete all as specified.
S&F in repair sink with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement morter to dwarft wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm, bowl size 410 mm x 330mm x 160mm complete all as specified and directed.
M&L in repair 75 mm dia PVC(SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed.
Supply & Fix in repair water closet vitreous China squatting pan, ' Orissa patteren, size 580 x 440 mm white, with integral footrests including trap but (excluding flushing cisteren and flush pipe) complete all as specified and directed.
S&F in repairs Vitreous china wash down water closet (EWC) white, pedestal pattern complete, including connection to drain pipe and to flushing pipe antisyphonage pipe, (excluding flushing cistern) incl plastic water closet seat back closed pattern with flat bottom cover and mild steel chromium plated or aluminized hinging device etc complete all as spd & directed
S&F in repairs PVC valveless , syphonic action flushing cistern 10 ltr capacity, low level, white, with inlet, ball valve, float and handle including brackets and PVC flush pipe complete all as specified.
M&L for granite (of any colour) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including grinding and polishing as in kitchen platform, flooring and all other similar works complete all as specified and directed.
Rounding to edges of stones slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and directed.
Taking down Chowkhats or frames with shutters (without taking of shutters from the frame) not exc 1.50 Sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) area exc 1.50 sqm and n.exc 4.00 sqm each complete all as specified and directed.
Dismantling wrought iron or mild steel, including gates work of any description not otherwise provided for complete all as specified and directed.
S &F mild steel framed work such as door frame, grills, gratings, etc., with ends of bar shoulder &/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks with Angle, MS sheet Flat iron & similar work conforming to Fe 290 GDE -E-165 (Ladders, door frames and cooler stand etc) complete all as specified and directed.
S & F 35mm thick second class hardwood factory made glazed and skeleton door shutters open rebated of second class hard wood rail and styles(Hollock), prepared to receive glass/gauge etc divided into square , with plain, chamfered or rounded, mitred and rebated sash bars any numbers , fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed. Note :- S & F Glass / gauge shall be measured and paid for separately
S&F factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing c given in SSR Part – II complete all as specified and directed.
S & F for Factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as given in SSR Part – II complete all as specified and directed.
S&F Flush shutters 35 mm thick, solid core construction, with block board core and plywood face panels, commercial type sunmica lamination on both sides complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire & average width of aperture 1.18mm & fixed with tinned tacks or galvanised wire staples fixed in wodden door or steel windows complete all as specified & directed.
S & F 200mm long SS barrel tower bolts not less than 12 mm dia of extruded section complete all as specified & directed.
S & F 300 mm long SS sliding door bolt with hasp, staple (bolt type) not less than 12 mm dia with & minimum of 6 bolts & nuts, 4 on bolt plate & 2 on staple plate complete all as specified & directed.
S&F 100 mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
S & F 150mm long SS handles cast moulded type fixed with screws complete all as specified & directed.
Supply & fix 75 mm size butt hinges, heavy weight, cold rolled mild steel complete all as specified and directed.
Supply & fix mild steel 300 mm, ordinary rat tail rod pattern springs, including roler and roller plate complete all as specified and directed.
M&L for preparation of new wooden or wood based surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over and incl a coat of pink primer complete all as specified and directed.
S&F powder coated any colour (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors/windows/ ventilators with one or more rebates including joining cleat for fixing etc complete all as specified.
S&F powder coated any colour (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, fixed / sliding type without sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing,locks, anodised alumnium snap beading, screws etc. complete all as specified
S& F 5.5 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares n.exc 0.5 sqm in each pane complete all as specified & directed.
S&F 5.5 mm thick frosted glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm each pane complete all as specified and as directed.
S&F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of operature 1.40mm and fixed with aluminium wire staples complete all as specified and as directed.
Supply and fix 50 micron thick coloured powder coated aluminium anodised grill design No DG-117,10 mm thick including F Sections complete all as specified and directed. Make :- M/s Deco grill / M/s Royal grill or Equivalent
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F 75 mm dia uPVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and as directed.
S&F 110 mm UPVC ventilation and rain water pipes single socketed (type A conforming to IS-13592) in any length with rubber ring joints fixed to wall complete all as specified & directed.
S&F 75 mm UPVC ventilation and rain water pipes single socketed (type A conforming to IS-13592) in any length with rubber ring joints fixed to wall complete all as specified & directed.
S&F 110 mm dia uPVC (SWR) bends any radius with oval access door complete all as specified and directed.
S&F 75 mm dia uPVC (SWR) bends any radius with oval access door complete all as specified and directed.
S&F 75mm uPVC(SWR) vent cowls complete all as specified and directed.
S&F 75 mm bore uPVC(SWR) branch piece, single y equal or unequal with access door complete all as specified and directed.
M&L precast RCC 1:2:4 type B-1, using 20mm graded stone aggregate for manhole cover including placing over manhole all as specified including demolition of old RCC manhole covers. Note :- Reinforcement shall be measured and paid separately.
S&F 110 mm bore uPVC(SWR) branch piece, single y equal or unequal with access door complete all as specified and directed.
Demolition stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and as directed by Engineer-in-Charge.
M&L 75mm thick PCC 1:4:8, type D2 (using 40mm graded agg) as in sub base complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L machine pressed precast concrete interlocking coloured rubber moulded paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, with grey cement and pigment laid over 25mm thick sand cushion complete all as specified and directed. Note : Sand for cushioning shall be measured and paid seperately.
M & L for 75mm thick PCC 1:3:6 , type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed .
Demolition of brick work or stone/boulder masonry, built in cement mortar mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
M&Lfor brick work with sub-class 'B' bricks (ols size), straight or curved on plan exc 6m mean radius built in In cement mortar 1:6 complete all as specified and directed
Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sq m on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete as per specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm.etc complete as per specified and directed.
Removing excavated material to a distance exc 250 metres but n exc 500 metres and depositing where directed at a level n exc. 1.5 m above the starting point. etc complete as per specified and directed.
Supplying and laying DWC pipes (Double wall corrugated) of class SN-4, conforming to IS-16098 (Part-II) of size internal dia of 200mm, laid in trenches and jointed complete with coupler, bends, tee, reducer etc complete all as specified & directed. Note : Earth work shall be measured and paid seperately.
E/M Portion Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings/fixing accessories and unwelded sunken galvanised pressed steel terminal modular boxes of thickness not less than 1.0 mm covered with modular cover plates for mounting modular switches, scokets, fan regulators as required for one light point controlled by one switch complete all as specified and directed.
All as per item No. 97 above but for one fan point controlled by one switch complete all as specified and directed.
All as per item No. 97 above but for One socket outlet 6 Amps controlled by one switch on the same board with other swithces complete all as specified and directed.
All as per item No. 97 above but for one socket outlet 6 Amps controlled by one switch on independent board complete all as specified and directed.
All as per item No. 97 above but for one bell point controlled by one bell push complete all as specified and directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 4 Sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings/fixing accessories and unwelded sunken galvanised pressed steel terminal modular boxes of thickness not less than 1.0 mm covered with modular cover plates for mounting modular switches, sockets as required for one 16 Amps socket outlet point controlled by one switch on independent board complete all as specified and directed.
Taking down carefully sub main wiring with PVC casing capping / PVC surface conduit and making good disturbed surfaces complete all as specified and directed.
M&L for sub main wiring with two run of 6 Sqmm single core, PVC insulated, FRLS multistranded copper conductor cable alongwith one run of 6.0 Sqmm earth wire as earth continuity conductor (Phase-Red, Neutral-Black, Earth-Green) drawing into and including concealed PVC conduit of 25mm dia ISI marked ivory colour & accessories of suitable size including making connection as required complete all as specified and directed. NOTE - Two run of 6 sq.mm phase and neutral wire & One run of 6 sq.mm earth wire & One run of PVC conduit with accessories shall be measured as One length.
S&F angle holder, insulated polycarbonate body with back plate complete all as specified and directed.
S&F in repair LED Z plus cool bright, 9 watt LED lamp of breaking capacity 6500K, beam angle > 120 degree complete all as specified and directed
S&F ceiling rose 3 plates polycarbonate body three terminal complete all as specified and as directed
S&F modular switch 1 way 6 Amps, 230 volts, 1 module complete all as specified and directed.
S&F modular switch 1 way 16 Amps, 230 volts, 1 module complete all as specified and directed.
S&F modular bell push, 6 Amp, 1 module complete all as specified and directed.
S&F electric door bell, ding dong, AC 240 volts, single pole complete all as specified and directed.
S&F modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts complete all as specified and directed.
S&F modular socket 6 Amps, 2/3 pin combined 2 module AC 230 volts complete all as specified and directed.
S&F modular hum free electronic step fan regulator 120-280 volts of 100 watts capacity (socket type), 2 module including connecting up complete all as specified and directed.
S&F in repair MCBs Distribution board SPN, 8 ways, powder coated, CRCA steel sheet, degree of protection IP-43, IK09 with reversible double door, 415V, recess mounted having insulated 100 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
S&F MCBs of 'C' curve single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
S&F MCBs of 'C' curve double pole 10 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
S&F LED bulk head light fitting 9/10 watt IP 66 & IK 09 with polycarbonate body with LED driver duly prewired connection with 0.75sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable complete all as specified & directed.
S&F LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficiency of 105 lumen per watt and total power consumption not more than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete all as specified and directed. Make - Philips Cat ref No. ENDURALED BATTEN "BN 308C LED20S PSU CDL WH, Bajaj cat ref No. BLTRU 20W WH VIVA or Havells Cat No. 600BS20WLED840SPCWH as approved by GE.
S&F LED batten (0.6m) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 900 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 10 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete all as specified and directed.
M&L for taking out ceiling fan 1200mm sweep 50Hz AC 230 volts and refixing at new location including minor repair and replacement of fan blade or spray painting in existing colour including 0.5sqmm thre core PVC insulated flexible copper conductor multistranded wire from fan motor to ceiling as required complete all as specified and directed.
S&F exhaust fan, high speed, metal body 300mm sweep, 1400 RPM, heavy duty motor with four blade, copper wound double ball bearings, grey colour with louver fixed on wall by making suitable size of hole and proper arrangement with nuts, bolts and washers and connecting up with three core 0.75sqmm copper cable from ceiling rose to fan and fix mosquito net with wooden frame of size open for exhaust fan in outer parts of building and make good on distibuted surfaces complete all as specified & directed.
All as per item No. 122 above but of sweep 225mm, 1200 RPM complete all as specified and directed.
S & F 20amp, single pole and neutral socket outlet, with 2 pole and earth, metal enclosed plug top in powder coated CRCA steel sheet enclosre recess mounted with chained matel cover for socket out let with and incl one single pole C curve MCB 16 Amps complete all as specified and directed.
M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I connected to earthing point and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 metre beyond outer edge of earth pit) making PCC pit of size 0.3m X 0.3m X 0.3m (inner size) in mix 1:3:6 type C1, 40 mm thick cover reinforced with 6 mm dia M.S bars, 3 nos both ways with lifting hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, including necessary excavation and earth work and testing on completion to achieve value not more than 2.0 ohm complete all as specified and directed.
Supply, laying, jointing, testing & commissioning 1100 volts grade, heavy duty, LT under ground cable XLPE insulated, , armoured cable with multi stranded aluminium conductor, served with inner seathed of PVC tape armoured with galvanised steel strip or wire and overall PVC sheathed, ISI marked, size 16 sqmm, 2 core, laid in trenches, ducts, pipes or fixed on poles including all necessary clamps, nut, bolt washers incl taking down U/S cable complete all as specfied and directed .
M&L for sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying complete all as specified and directed by the Engr-in-Charge Note : punned thickness shall be measured for payment.
M & L bricks for protection cover to UG cable (with old size sub class B bricks) with width equal to length of brick, laid dry and flat abutting each other with gaps between adjecent bricks not exceeding 10mm complete all as specified and directed.
S & F 40 mm bore GI tubing light grade with all fitting (ISI marked), fixed to wall/ pole / laid in road crossing etc as reqd complete all as specified and directed.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
M/S JALANDRA CONSTRUCTIONS (BID ID -3086013)
JAGDAMBA CONSTRUCTION COMPANY (BID ID -3093632)
UNIVERSAL INFRAPROJECT PVT LTD (BID ID -3076581)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .