Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC 19 A NIRUPAMA DEVI ROAD LANE 1 BERHAMPORE MURSHIDABAD | BERHAMPORE | MURSHIDABAD | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹21.2 L+₹23,101.85 (1.10%)Rejected-Finance 76 CRIPER ROAD KONNAGAR HOOGHLY | KONNAGAR | HOOGHLY | WEST BENGAL | L2 | Rejected-Finance NOT L1 BIDDER | |
| 3 | L3₹21.2 L+₹23,201.96 (1.11%)Rejected-Finance 1 6 FAKIR CHAKRABORTY LANE | L3 | Rejected-Finance NOT L1 BIDDER |
| Sl No | Description | Qty | Unit | M/S. Sajahan Chowdhury L1 | MAHADEV ENTERPRISE L2 | H.K.DAS AND CO. L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & delivery of Membrane element for RO unit, Capacity 2000 lit/hr Suitable for installation in RO vessel diameter 8" & length 40". As per following specification:- 1) Permeate Flow:- Minimum 10000 gpd (3.75 m³ /d) 2) Salt Rejection:- (99.5% minimum) 3) Configuration:- Spiral wound 4) Membrane polymer:- Composite Polymide 5) Nominal membrane Area:- Minimum 365 ft² (33.9m²) 6) Maximum applied pressure:- above 450 psi 7) Maximum operation temperature:- Not above 122˚F (50˚C) 8) pH range, continuous (Cleaning):- 2-11 (1-13) 9) Maximum Feed water Turbidity:- Upto 1.0 NTU 10) Maximum Feed water SDI (15 mins):- Upto 5.0 11) Maximum Feed Flow:- 75 GPM (17.0m³/h) 12) Minimum Ratio of Concentrate to permeate Flow any Element:- 5.1 13) Maximum pressure drop for Each Element:- 10 psi (Make:- Hydranoutics/Dow/Toray/GE/Other approved make) | 2 | Nos | 2,38,475 ₹4,76,950 Lowest | 2,41,321 ₹4,82,642 | 2,39,995 ₹4,79,990 |
| 2.00 | UF unit for removing all undisclosed impurities including suspended solids, colidall impurities having Feed Pressure- 5 Bar, Operating Tran membrane Pressure- 2 psig, Maximum Backwash- 20 psig as per following specification:- 1) Filtrate Flow: 12.1 - 29.5 gpm 2.7 - 6.7 m³/hr) 2) Filtrate Turbidity- ≥ 00.7 NTU 3) Virus removal- 4 log 4) Bacteria removal- ≥ 4 log 5) Configuration:- Capillary Ultrarafitration Module 6) Membrane Polymar:- Hydophilic Poly thersulfone 7) Nominal Membrance Area:- 500 ft²(46m²) or above 8) Fiber Dimensions- ID 0.031" (0.8mm) OD 0.055" (1.4mm) 9) Pore size:- 0.02 micron or less 10) Typical Filtrate Flux Rnage:- 35-85 gfd (59-1451/m²/h) 11) Maximum Applied Feed Pressure 73 psig (5bar) 12) Maximum Transmembrane Pressure 20 psig (1.4 bar) 13) Maximum backwash transtmembranece Presuure:- 20 usig (1.4 bar)
14) Instanteneous Chlorine Tolerance: 100 ppm 15) Instantaneous Hydrogen Peroxide Tolerance:- 200 ppm
16) maximum chlorine Expossure:- 200.000ppm-hrs 17) maximum instantaneous Feed Turbidity:- 100 NTU 18) Maximum Operating Temperature:- 104˚F 19) pH opearting range:- 4.0-10.0 20) Clraning pH range:- 1.5-13.0 21) Opearting Mode:- Inside to Outside Filtration Direct flow of Crossflow
22) Backwash flux:- 100-150 gfd (170-255 l/m²/hr) 23) Backwash Duration:- 30-60 seconds 24) Backwash Frequency:- 20-60 minutes 25) Chemical Enhanced Backwash Frequency:- 0-4 ties per day
26) Chemical Enhanced Backwash Duration:- 1-30 minutes 27) Disinfection Chemical- Na0Cl. H₂O₂, CLO₂ or NH₂Cl 28) Cleansing Chemical:- Na0H, HCL, H₂SO₄ or Citric Acid (Make:- Suez / Dow / Toray) | 2 | Nos | 5,27,144 ₹10,54,288 Lowest | 5,29,770 ₹10,59,540 | 5,30,230 ₹10,60,460 |
| 3.00 | Supply & delivery of SS Micron Cartidge Filter/Busket strainer for UF unit 100 micron SS, 20" long (Jumbo Type) lD:- 50mm
OD:- 100mm
Lenght:- 500mm
Flow Capacity: 6m3/hr
construction core not required
Clean DP- 100mbar
Maximum Operating Temperature- 200 deg C
(Make:- Gopani preferably of equivalent) | 2 | Nos | 57,555 ₹1,15,110 Lowest | 59,235 ₹1,18,470 | 61,300 ₹1,22,600 |
| 4.00 | Supply & delivery of at site 5 Micron jumbo wond type pre filter Cartidge of RO Filter assembly with below mention specification
1) Ld:- 4.5"
2) OD:- 6"
3) Lenght:- 20"
4) Flow capacity:- 5m³/hr
5) Care Cover Material:- Poly Propylenem
6) Care:- Poly Propylenem
7) Clean Ps 10 Psid
8) Maximum Operating Temperature:- 120 ˚F (49˚C) | 2 | Nos | 51,779 ₹1,03,558 Lowest | 54,225 ₹1,08,450 | 53,112 ₹1,06,224 |
| 5.00 | Supply & delivery of of Horizontal & Vertical Electrode, L=190mm. | 8 | Nos | 637 ₹5,096 Lowest | 649 ₹5,192 | 640 ₹5,120 |
| 6.00 | Supply and delivery of of Rubber Strip (H 4mm x 18mm x 4mm) | 4 | Nos | 75 ₹300 Lowest | 81 ₹324 | 89 ₹356 |
| 7.00 | Supply and delivery of Teflon Tape (18 x 300 mm imported) | 4 | Nos | 748 ₹2,992 Lowest | 765 ₹3,060 | 753 ₹3,012 |
| 8.00 | Add GST @ 18% | 1 | Nos | 3,16,492.92 ₹3,16,492.92 Lowest | 3,19,982.04 ₹3,19,982.04 | 3,19,997.16 ₹3,19,997.16 |
| 9.00 | Add CESS @ 1% | 1 | Nos | 20,747.87 ₹20,747.87 Lowest | 20,976.6 ₹20,976.6 | 20,977.59 ₹20,977.59 |
Tender Value
Refer Docs
EMD Value
₹43,000
Closing Date
13 Mar 2026, 4:00 pmClosed
Executive Engineer,AMD P.H.E dte
Office of the Executive Engineer,Asansol Mechanical Division,Public Health Engineering Directorate,SEN-RALEIGH ROAD,PASCHIM BARDHAMAN 713305
Supply and delivery of following MTUs spares for repairing and overhauling of the same, under Asansol Mechanical Division, Dist-Paschim Bardhaman.
2026_PHED_1012042_7
WBPHED/EE/AMD/ NIeT-44 of 2025-2026
Open Tender
Miscellaneous Works
Item Wise
30 days
MTU
Please refer Tender documents.
4 documents required · 4 mandatory
₹43,000
Yes
10 Jun 2026
20 Feb 2026
16 Mar 2026
20 Feb 2026
13 Mar 2026
20 Feb 2026
Supply & delivery of Membrane element for RO unit, Capacity 2000 lit/hr Suitable for installation in RO vessel diameter 8" & length 40". As per following specification:- 1) Permeate Flow:- Minimum 10000 gpd (3.75 m³ /d) 2) Salt Rejection:- (99.5% minimum) 3) Configuration:- Spiral wound 4) Membrane polymer:- Composite Polymide 5) Nominal membrane Area:- Minimum 365 ft² (33.9m²) 6) Maximum applied pressure:- above 450 psi 7) Maximum operation temperature:- Not above 122˚F (50˚C) 8) pH range, continuous (Cleaning):- 2-11 (1-13) 9) Maximum Feed water Turbidity:- Upto 1.0 NTU 10) Maximum Feed water SDI (15 mins):- Upto 5.0 11) Maximum Feed Flow:- 75 GPM (17.0m³/h) 12) Minimum Ratio of Concentrate to permeate Flow any Element:- 5.1 13) Maximum pressure drop for Each Element:- 10 psi (Make:- Hydranoutics/Dow/Toray/GE/Other approved make)
UF unit for removing all undisclosed impurities including suspended solids, colidall impurities having Feed Pressure- 5 Bar, Operating Tran membrane Pressure- 2 psig, Maximum Backwash- 20 psig as per following specification:- 1) Filtrate Flow: 12.1 - 29.5 gpm 2.7 - 6.7 m³/hr) 2) Filtrate Turbidity- ≥ 00.7 NTU 3) Virus removal- 4 log 4) Bacteria removal- ≥ 4 log 5) Configuration:- Capillary Ultrarafitration Module 6) Membrane Polymar:- Hydophilic Poly thersulfone 7) Nominal Membrance Area:- 500 ft²(46m²) or above 8) Fiber Dimensions- ID 0.031" (0.8mm) OD 0.055" (1.4mm) 9) Pore size:- 0.02 micron or less 10) Typical Filtrate Flux Rnage:- 35-85 gfd (59-1451/m²/h) 11) Maximum Applied Feed Pressure 73 psig (5bar) 12) Maximum Transmembrane Pressure 20 psig (1.4 bar) 13) Maximum backwash transtmembranece Presuure:- 20 usig (1.4 bar) 14) Instanteneous Chlorine Tolerance: 100 ppm 15) Instantaneous Hydrogen Peroxide Tolerance:- 200 ppm 16) maximum chlorine Expossure:- 200.000ppm-hrs 17) maximum instantaneous Feed Turbidity:- 100 NTU 18) Maximum Operating Temperature:- 104˚F 19) pH opearting range:- 4.0-10.0 20) Clraning pH range:- 1.5-13.0 21) Opearting Mode:- Inside to Outside Filtration Direct flow of Crossflow 22) Backwash flux:- 100-150 gfd (170-255 l/m²/hr) 23) Backwash Duration:- 30-60 seconds 24) Backwash Frequency:- 20-60 minutes 25) Chemical Enhanced Backwash Frequency:- 0-4 ties per day 26) Chemical Enhanced Backwash Duration:- 1-30 minutes 27) Disinfection Chemical- Na0Cl. H₂O₂, CLO₂ or NH₂Cl 28) Cleansing Chemical:- Na0H, HCL, H₂SO₄ or Citric Acid (Make:- Suez / Dow / Toray)
Supply & delivery of SS Micron Cartidge Filter/Busket strainer for UF unit 100 micron SS, 20" long (Jumbo Type) lD:- 50mm OD:- 100mm Lenght:- 500mm Flow Capacity: 6m3/hr construction core not required Clean DP- 100mbar Maximum Operating Temperature- 200 deg C (Make:- Gopani preferably of equivalent)
Supply & delivery of at site 5 Micron jumbo wond type pre filter Cartidge of RO Filter assembly with below mention specification 1) Ld:- 4.5" 2) OD:- 6" 3) Lenght:- 20" 4) Flow capacity:- 5m³/hr 5) Care Cover Material:- Poly Propylenem 6) Care:- Poly Propylenem 7) Clean Ps 10 Psid 8) Maximum Operating Temperature:- 120 ˚F (49˚C)
Supply & delivery of of Horizontal & Vertical Electrode, L=190mm.
Supply and delivery of of Rubber Strip (H 4mm x 18mm x 4mm)
Supply and delivery of Teflon Tape (18 x 300 mm imported)
Add GST @ 18%
Add CESS @ 1%
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
2911.pdf
Tender Documents • 0.51 MB
BOQ_2485439.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .