GE Faridkot
GE Faridkot-151203
Provn of Internal Electrification, Security Lights, Special repair to Lightening conductors at various location at Faridkot Mil Stn
2020_MES_311387_1
GE FRD-69/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Faridkot Mil Stn
Class E Category b i
8 documents required · 8 mandatory
₹500
GE Faridkot
₹40,400
Yes
10 Feb 2020
3 Jan 2020
3 Feb 2020
3 Jan 2020
1 Feb 2020
17 Jan 2020
Amount
Taking down the existing jumbled up sub main / service cable from the existing LT Panel underground or laid along wall / roof from ceiling height 6.5m from the area of Officer Mess Arty Bde from starting point to terminal ends all including re-routing the same after segrigation of serviceable cable of size 6 Sqmm 2 Core Aluminium conductor complete directed by Engineer-in-Charge.
Taking down the existing jumbled up sub main / service cable from the existing LT Panel underground or laid along wall / roof from ceiling height 6.5m from the area of Officer Mess Arty Bde from starting point to terminal ends all including re-routing the same after segrigation of serviceable cable of size two run of 6/10 Sqmm 2 Core Copper conductor complete directed by Engineer-in-Charge.
M & L wiring with two runs of 6 Sqmm size main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FR cable of specified size with multi stranded copper conductors, 1100 volts grade, IS-694 marked, drawn through in existing conduit or cable trunking concealed / surface (as per existing), all fixed into the surface of wall / roof and also including the specified run and size earth continuity conductor of similar type cable completed all as specified and directed by Engineer-in-Charge. Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and the relevant accessories shall be measured as one run length.
M & L wiring with two runs of 4 Sqmm size main cable and one run of 4 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FR cable of specified size with multi stranded copper conductors, 1100 volts grade, IS-694 marked, drawn through in existing conduit or cable trunking concealed / surface (as per existing), all fixed into the surface of wall / roof and also including the specified run and size earth continuity conductor of similar type cable completed all as specified and directed by Engineer-in-Charge. Note : Two runs of 4 Sqmm single core cable and one run of 4 sqmm copper wire earth continuty conductor and the relevant accessories shall be measured as one run length.
M & L wiring with two runs of 10 Sqmm size main cable and one run of 10 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FR cable of specified size with multi stranded copper conductors, 1100 volts grade, IS-694 marked, drawn through in existing conduit or cable trunking concealed / surface (as per existing), all fixed into the surface of wall / roof and also including the specified run and size earth continuity conductor of similar type cable completed all as specified and directed by Engineer-in-Charge. Note : Two runs of 10 Sqmm single core cable and one run of 10 sqmm copper wire earth continuty conductor and the relevant accessories shall be measured as one run length. Note for Srl item No. 3 to 5 : (a) All cables laid on trays shall be carefully aligned & suitably clamped / tied upto the tray. (b) Rate quoted is deemed to be included for thimbles lugs etc as per site requirement. (c) Contractor must visit the site and ascertain himself about the over simplification of the work before quoting the rates.
Supply and laying XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with stranded aluminium conductor 1100 Volts grade confirming to IS - 7098 (Part-I, 1988) cross sectional area 50 Sqmm 3.5 core including thimbles / lugs with and including passing through pipe along wall, under road crossing / Nallah / under floor etc complete all as specified and directed by Engineer in Charge. (Note : Earth work, sand cushioning, GI pipe protection and brick protection to be measured and paid seperately).
S&F MCCB 63 Amps 4 Pole rupturing capacity 16 KA, 415 V in sheet metal enclosure duly recess in wall complete all as specified and directed by Engineer in Charge.
S&F factory made sheet metal enclosure for double door distribution board with epoxy powder coated surface mounted SP & N 12 way, protection class IP-43 suitable for mounting MCB, conforming to IS-8623, BS-5484 with 200 Amps rated copper bus bar stove enameled dust and vermin proof suitable for working on 240 volts AC supply complete all as specified & directed by Engineer-in-Charge.
S&F factory made sheet metal enclosure for double door distribution board with epoxy powder coated surface mounted SP & N 8 way, protection class IP-43 suitable for mounting MCB, conforming to IS-8623, BS-5484 with 200 Amps rated copper bus bar stove enameled dust and vermin proof suitable for working on 240 volts AC supply complete all as specified & directed by Engineer-in-Charge.
S&F factory made sheet metal enclosure for double door distribution board with epoxy powder coated surface mounted TP & N 4 way, protection class IP-43 suitable for mounting MCB, conforming to IS-8623, BS-5484 with 200 Amps rated copper bus bar stove enameled dust and vermin proof suitable for working on 415 volts AC supply complete all as specified & directed by Engineer-in-Charge. Note for Item No. 7 to 10:- Make of the MCB shall be the same as that of DB.
S&F MCB SP&N 240 volt 63 Amp having rupturing capacity 10 KA C Curve complete all as specified and directed by Engineer in Charge. Note : Make of the MCB shall be the same as that of DB.
S&F MCB single Pole 240 Volts 40 Amp rupturing capacity not less than 10 KA C Curve complete all as specified and directed by Engineer in Charge. Note : Make of the MCB shall be the same as that of DB.
S&F MCB single Pole 240 Volts 6 to 32 Amp rupturing capacity not less than 10 KA B Curve complete all as specified and directed by Engineer in Charge. Note : Make of the MCB shall be the same as that of DB.
Supply & fixing electronic energy meter tamper proof with LCD display with Class 1 accuracy single phase 240 V, 10 to 60 Amps capacity fixed in Guest Room No. 2 and write letter "Guest Room No. 2" with brush complete and all as directed by Engineer-in-Charge.
Supply & fixing multi function electronic energy meter tamper proof class 1.00 acuracy with LCD display with Class 1 accuracy single phase 240 V, 5 to 40 Amps capacity fixed in Guest Room and write letter "Guest Room No. " with brush complete and all as directed by Engineer-in-Charge.
Supply & fixing Meter box for single phase electronic energy meter fabricated from 8mm CRCA sheet of size 306mmx143mmx120mm complete and all as directed by Engineer-in-Charge. Make : ESTERA / C&S / HPL
Supply, fixing and testing LED street light fitting of 45 Watt including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP-65 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fittings should be suitable for ambient temperature from - 10 degree centrigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report complete all as specified and directed by Engineer-in-Charge. Make: Bajaj/ Havells/Philips or equivelant Note :- (a) Bidder shall submit rest report of LED street light fitting from accredied test laboratory for LM-79 (b) Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects, (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) scope of work shall include supply and fixing street light fittings on poles which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. Note: (i) Every light fitting will be warranty 5 years after completion of CA and replacement/defects as applicable should be complied/rectified within 7 days . (ii) All three runs of cable from LT overheat line to fittings upto 1.5 mtr long of suitable size deemed to be included in unit rate of above and nothing extra shall be paid.
Supply & fixing in replacement of street light bracket suitable for LED 45 watt as per sample at site made out of 40 mm bore GI pipe light grade pipe, length exc 1 mtr but not exc 1.5 mtr and bent to shape complete all as specified and directed by Engineer-in-Charge.
S&F 4 sqmm twin core , 1100 volts grade heavy duty cable, PVC insulated aluminium multistranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed for making connections of street light fittings with overhead lines/UG Cablecomplete all as specified and directed by Engineer-in-Charge.
Supply, fixing and testing LED street light fitting of 25 Watt including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP-65 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fittings should be suitable for ambient temperature from - 10 degree centrigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection cover should not degrade due to heating and ageing. The efficient of LED luminaries system shall be more than 85 lumens per watt and must be certified by LM-79 test report complete all as specified and directed by Engineer-in-Charge. Make: Bajaj/ Havells/Philips or equivelant Note :- (a) Bidder shall submit rest report of LED street light fitting from accredied test laboratory for LM-79 (b) Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects, (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) scope of work shall include supply and fixing street light fittings on poles which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. Note: Every light fitting will be warranty 5 years after completion of CA and replacement/defects as applicable should be complied/rectified within 7 days .
M & L for point wiring complete with PVC insulated and unsheathed cable 1.5 Sqmm (Nominal area) multistranded copper conductor single core including PVC conduit medium grade ISI marked of appropriate size concealed in wall, 1.60mm thick pressed steel concealed terminal boxes and with top cover 2.80mm thick ISI marked plastic laminated hylum sheet of required colour fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat of red oxide primer complete with all accessories and all as specied including 1.5sqmm PVC insulated unshethed multistranded copper conductor to common earth and connected to earth dolly for One light/fan/bell/exhaust fan point controlled by one switch complete all as specified and directed by Engineer in Charge. Note : Cutting chases if any, required for concelaed conduit wiring shall be finished with cement mortar (1:4) and surface shall be matched with existing surface by using putty, POP etc and applying finishing coat of existing treatment without any extra cost.
S&F switch piano type single pole one way 5 Amp,230 VAC supply complete all as specified and directed by Engineer in Charge.
S&F Ceiling rose, three terminals AC 230 Volts with bakalite 65x50mm back plate complete all as specified and directed by Engineer in Charge.
S&F of air termination rod 12 mm dia single pointed 300 mm long along with base plate welded at bottom of termination rod,of size 10 cm long fabricated out 25x3 mm thick aluminium strip along with making 9 mm dia for fixing in fastners (wooden block) complete all as specified and directed by Engineer -in-Charge.
M&L for aluminium strip 25mmx3.15mm complete with seaddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed by Engineer -in-Charge.
Material & labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6mm galvanised iron strip complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 50mm dia upto earthing test point/equipment fixed with 2 Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:3:6) type C-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Note:- (i) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe shall be provided in slantling position. (iv) Unit rate included earth wire strip and protection pipe upto 7.50 meter from top of earth plate.
M&L for test points as per IS specifications of shape and size as approved by GE and Engineer-in-Charge, made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos, 8mm dia, 25 mm long hexagonal screw complete all as specified and directed by Engineer -in-Charge.
Supply & Fixing and testing in renewal LED flame proof light fitting 1 x 18/20 watt including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 1700 lumens, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin suitable for Gas/vapur of IIA & IIB and Zone 1 & 2 including connecting up with twin core twisted flexible copper conductor with suitable size complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing LED light fitting 1 x 20 watt including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 1700 lumens, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin suitable for Gas/vapur of IIA & IIB and Zone 1 & 2 including connecting up with twin core twisted flexible copper conductor with suitable size complete all as specified and directed by Engineer-in-Charge.
Taking down carefully existing aluminium/copper point wiring light, fan socket or power bell complete with fitting such as switches, sockets, ceiling roses, pendants batten holders regulators socket, call bells and making good to the disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed by Engineer in Charge.
M & L for point wiring complete concealed with PVC insulated and unsheathed, flame retardant (FRLS) flame retardent low smoke 1100 volt grade electric cable of 1.5sqmm (nominal area) with multi stranded copper conductor single core in and including rigid PVC concealed conduit not less than 19mm dia, clip with suitable MS terminal boxes (not less than 1.0mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint including earth dolly with 3mm thick plastic laminated sheet top cover of approved colours including 1.50 sqmm green solid copper conductor as continous earth wire with all acessories including lugs required for One light/fan point controlled by one switch complete all as specified and directed by Engineer in Charge.
All as per item No 32 here in before but One 3/5 pin, 5 Amp socket outlet point controlled by one switch on independent board complete all as specified and directed by Engineer in Charge.
All as per item No 32 here in before but One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board complete all as specified and directed by Engineer in Charge.
All as per item No 32 here in before but using 2.5 Sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant Low smoke (FRLS) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 2.5 sqmm green sold copper conductor as continous earth wire with lugs complete all as specified and directed by Engineer in Charge.
S&F ceiling fan regulator 0-4 steps 450W hum free including 6 A socket frame and including connections complete all as specified and directed by Engineer in Charge. Cat Part No. F-911 for regulator and F-920 for socket frame of Make SSK or equivelant in Legrand/ Hager
S&F switch 6 Amps 250 V AC one way with ISI mark including 6 A Scoket frame complete all as specified and directed by Engineer in Charge. Cat Part No. F-900 for switch and F-919 for switch frame of Make SSK or equivelant in Legrand/ Hager
S&F 5 Pin shuttered 6 Amps 250 V AC with ISI mark including 6 A Scoket frame complete all as specified and directed by Engineer in Charge. Cat Part No. F-904 for socket and F-920 for socket frame of Make SSK or equivelant in Legrand/ Hager
S&F switch single pole mini with porcelain base 16A 250 V AC with ISI mark including switch frame complete all as specified and directed by Engineer in Charge. Cat Part No. F-954 for switch and F-919 for switch frame of Make SSK or equivelant in Legrand/ Hager
S&F 5 Pin shuttered 6 / 16 Amps 250 V AC 2 in 1 with ISI mark including 16 A Scoket frame complete all as specified and directed by Engineer in Charge. Cat Part No. F-951 for socket and F-920 for socket frame of Make SSK or equivelant in Legrand/ Hager
S&F of submain wiring with 2x4 sqmm nominal area of PVC insulated unsheathed stranded copper conductor cable in and including ERW rigid conduit stove enamelled concealed conduit including FP junction box, FB bend, FP reducer including 2 run of copper wire as specified above for earth wire to common earth and connected to earth dolly complete all as specified and directed by Engineer-in-Charge.
S&F of submain wiring with 2x2.5 sqmm nominal area of PVC insulated unsheathed stranded copper conductor cable in and including ERW rigid conduit stove enamelled concealed conduit including FP junction box, FB bend, FP reducer including 2 run of copper wire as specified above for earth wire to common earth and connected to earth dolly complete all as specified and directed by Engineer-in-Charge.
M &L Bulkhead fitting flame proof luminaries die cast anodized aluminium body epoxy white powder coated heat resistant prismatic glass cover with specially designed gasket including LED 1x10 watt 230 volts and connection complete all as specified and directed by Engineer in Charge.
S & F flame proof distribution board made of die cast of aluminium alloy (LM-6) GAS group 11A, 11B certified by CMRI Dhanbad suitable MCB SPN 8 way 230 volts suitable and including for incoming isolator SPN - 01 Number and outgoing for MCB SP-06 Nos. and conforming to IS-2148/2004 of 13346/2004 complete all as specified and directed by Engineer in Charge. Note : Cost of MCB will be included in unit rate.
S & F flame proof distribution board made of die cast of aluminium alloy (LM-6) GAS group 11A, 11B certified by CMRI Dhanbad suitable MCB SPN 12 way 230 volts suitable and including for incoming isolator SPN 40 Amp - 01 Number and outgoing for MCB SP-06 to 32 Amp 10 Nos. and conforming to IS-2148/2004 of 13346/2004 complete all as specified and directed by Engineer in Charge. Note : Cost of MCB will be included in unit rate.
M & L for distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyster or with powder coating surface mounting SPN 8 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCBs and isolators etc complete all as specified and directed by Engineer in Charge.
All as per srl item No. 46 here-in-before but TPN 4 way 415 Volts complete all as specified and directed by Engineer in Charge.
S & F MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA as specified and 40 Amps complete all as specified and directed by Engineer in Charge. Note : Make of the MCB shall be the same as that of DB.
S&F Isolator suitable for 415 volts AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10KA as specified and 63 Amps complete all as specified and directed by Engineer in Charge. Note : Make of the MCB / Isolator shall be the same as that of DB.
Excavating in trenches in soft/loose soil n exc 1.5 m deep and and n exc 1.5 m wide; for taking out of unserviceable / defective LT underground cable complete all as specified and directed by Engineer in Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer in Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer in Charge.
M & L for sand cushioning with river washed and screened dry fine sand to under ground cable 23cm thick, 15 cm below the cable and 8 cm after laying the cable complete all as specified and directed by Engineer-in-Charge. NOTE;- Thickness after punning shall be considered for payment.
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable complete all as specified and directed by Engineer in Charge.
Supplying laying and fixing of XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with standard aluminium conductor 1100 volts grade confirming to IS-1554 cross sectional area 16 Sqmm 4 core including thimbles/lugs complete with and including passing through pipes or laid under floor or through walls etc all as specified and directed. (Note : Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately)
S & F Pole mounted PVC/FRP looping box of size 225 x 200 x 75mm including loop out bus bar 100 Amp capacity and railing for fixing MCB, cable terminals necessary fixing arrangement with poles suitable for single phase connection with locking arrangement including necessary nuts, bolts & clamps of flat iron 25 x 3mm complete 2FI clamp & nuts, bolts & washers etc including MCB SP 6-30 Amp capacity complete all as specified and directed by Engineer in Charge.
S&F of pipe galvanised iron light grade 20mm dia ISI marked complete for cable protection laid in trenches, floors, fixed to walls, pole with suitable FI clamps complete all as specified and directed by Engineer in Charge.
S&F of PVC conduit 15mm dia ISI marked complete for cable protection fixed to walls, pole with suitable FI clamps complete all as specified and directed by Engineer in Charge. Note :- A Sum of Rs. 11,560.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 23 (Schedule of credit) of Tender Documents.
M/S RAJESH KUMAR and CO.
V R TRADERS
M/s Balvinder Singh Engineer and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .