| 1 | L1₹10.6 LAccepted-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L1 | Accepted-AOC Accept | |
| 2 | L2₹13.5 L+₹2.5 L (23.2%)Rejected-AOC | L2 | Rejected-AOC Reject |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
12 Oct 2021, 6:00 pmClosed
GE Bharatpur
Kanjoli line Bharatpur
Repair to security light, street light and connected items at RMS Dholpur under GE Bharatpur.
2021_MES_474343_1
8068/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
GE Bharatpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹19,000
Yes
17 Dec 2021
10 Sept 2021
14 Oct 2021
10 Sept 2021
12 Oct 2021
30 Sept 2021
11 Sept 2021 - 14 Sept 2021
Amount
Attending day to day complaints of street lights, replacing burnt out wires, reconnection of loose terminals, securing the clamps, jumpers etc complete all as specified and as directed. Note: Contractor shall provide suitable electrician and helper for complince including all kind of climbing and safety materials along with tools. Rates including taking down, repairing and reconnecting as per existing position. Complete all as specified and directed
Attending day to day complaints of street lights replacing LED drivers, surge arresters, replacing 2 core aluminium cables, replacing connector of street lights, repairing LED driver and surge arrester circuits etc all as specified and complete all as specified and as directed. . Rates including taking down, repairing and reconnecting as per existing position. Complete all as specified and directed Note 1- LED Driver, surge arrester, 2 core/4core aluminium cable & connector shall be measured and paid separately.
S&F in replacement of street light GI bracket of 1.5 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of flat iron 40 x 6mm including nuts, bolts & washers complete necessary fixing arrangements on pole complete all as specified and directed.
Supplied and fixed in repair Pin type , porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for working pressure 1100volts grade, complete all as specified and directed.
S&F in replacement for shackle type , porcelain, vitreous, white, brown or green insulator including galvanised mild steel Strips, washers, insulators bolts, washers and nuts for working pressure 1100Volts , 100mm height 115mm dia, galvanised steel fitting strips of size 21 x 5mm, 14mm dia bolts complete all as specified and directed.
S&F in repairs 1100 volts grade line composite phase separators moulded and bolted type as per IS-1445-1997 (make - max well or Dension) suitable for 3 lines complete all as specified and as directed.
S&F in replacement of MCCB 04 pole 100 Amp, DPX3 160 Thermal magnetic breaking capacity not less than 25KA, 415 volts complete all as specified and directed. (Cat Part No IHLGHF0100 of Havells or equivalent makes mentioned in Appx B)
S&F in replacement of MCCB 04 pole 63 Amp, DPX3 160 Thermal magnetic breaking capacity not less than 16KA, 415 volts complete all as specified and directed. (Cat Part No 420053 in Legrand or equivalent makes mentioned in Appex B)
Supply & Fix in repairs of LED based Street light , housing made up of pressure die cast aluminium Alloy with effective thermal management, sturdiness. The fixture should have a minimum system efficiency more than 80 lumen/Watt and a minimum system lumen output of not less than 7200 lumens and maximum system wattage 70Watts. The fixture shall have correlated colour temperature of atleast 5000K and a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance. Ingress protection of IP 66 (lamp and gear Compartment and mechanical impact resistance rating ofIK >= 05. The fixture driver should have an operating voltage range 140-270 V, surge protection not less than 4KV, PF > 0.95 and THD < 15%. The fixture should comply to IEC 61000-3-2 ed 3.2 per harmonics IEC 61347-2-3 2006 in configuration with IEC 61347-1 ed 2.0, 2007 for electrical safety LM 79 and LM 80 test report needs to be submitted from NABL. The driver should have double phase protection. LED Light fitting should be suitable for ambient temperature from (-) 10 deg C to (+) 50 deg C as per IS 10322 and for EMI and LM 79 test reports , including making modification to existing street light bracket for fixing LED light if required , with suitable size clamp, nut bolts and washers as per site requirement complete all as specified and directed. (Note:- The manufacture of LED fitting shall give Guarantee for 2 Years from the date of installation). make - Havells cat pt No ENDURACITYLINERNEOSL70WLED757PASYBOTG or equivalent in Phillips, CG, Wipro and Syska.
S&F in replacement of LED Flood light fittings 200 watts complete all accessories and fittings duly prewired and pressure die cast aluminium housing , heat resistant tough glass with frame , IP 65/66 protection and better optic for uniforms distribution complete all as specified and directed. Make - Havells cat Part no JETAVALOURFL200WLED757PINTWBLTG or equivalent in Phillips/Bajaj/CG
Supply only electronic surge arresters in replacement of old UNSV one while repairing the street light/ flood lights, of model No SRPS-HP-5K-440 or SRPS-HP-5K-320 Complete all as specified and directedof make Crompton greaves or equivalent make in Phillips/Bajaj .
Supply only electronic LED drivers in replacement of old UNSV one while repairing the street light/ flood lights of capacity 60Watt to 75Watt, voltage range 1-10Vdc, Current range 0.7Adc, Temp range -20 degree to +55 degree celcius, made in india, Make Phillips or equivalent in Crompton Greaves/Bajaj Complete all as specified and directed
Supply only electronic LED drivers in replacement of old UNSV one while repairing the street light/ flood lights of capacity 90Watt to 200Watt, voltage range 1-10Vdc, Current range 0.7Adc, Temp range -20 degree to +55 degree celcius, made in india, Make Phillips or equivalent in Crompton Greaves/Bajaj Complete all as specified and directed. Note:- for item No 12 to 14:- The rate for fixing is included in quoted rate of item No 2
M&L for Ceaning of street light housing and protection glass, removing dead fly with dry clean cloth after dismantling the fitting from the bracket, removing all electrical connections from the OH line with the help of one trained electrician and two helpers for holding ladders etc. refitting it after cleaning the street light fittings, checking of all internal wirings and connecting the wires to existing point of OH line etc Complete all as specified and directed Note: Contractor shall provide adequate safety equipments, safety belts, helmets, bamboo ladders etc by his own arrangements. No transportation and conveyance shall be provided by the MES for repair/maint of street lights and OH lines.
M&L for Re-stringing ACSR conductor of street light feeder (1ph and neutral) any type size stringing properly on insulator and binding with aluminium tape/connectors, jumpers etc drawing as OH/LT line including dismantling/taking down old u/s ACSR conductor from poles including jumper and cable connection etcComplete all as specified and directed.
M & L for Clearing of LT street light feeder over head line from tree branches by trimming the tree branches etc and clearing the site by disposing the trimmed branches without any disturbance to eco system by burrying under the ground or disposing by waste management vehicle etc (conductor length between two poles shall be measured in Running Metre as one length) and cleaning the area by JCB when required to cut unwanted tree and to level the field as required Complete all as specified and directed.
Supply and fixing in repair Auxiliary contactor 22Amp, AC 3ph, suitable for timer switch complete all as specified and directed. Make L&T MNX22 or euivalent in Havells/Schneider
Supply and fixing in repair MCB TP 25Amp, 10KA complete all as specified and directed.
S&F in replacement timer switch 24Hrs Analog dial type suitable for street lights and high mast lights with complete assembly 63Amps capacity, comprising one contactor of 40Amp and one MCB TPN of 40Amp, outdoor type with enclosure and clamping arrangements including taking out the old UNSV one any size and type Complete all as specified and directed.. Make- Havells or equivalent in L&T/Schneider
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying HT/LT UG cable, Fibre Optic Cable etc and getting out in hard disintegrated rock Complete all as specified and directed.
Excavation in trenches not exc 1.5 m but not exc 3.0m in depth and not exc 1.5 wide for fixing of boles etc and getting out in hard disintegrated rock complete all as specified and directed.
Removing excavation soil at a distance not exc 50 m and deposited where directed Complete all as specified and directed.
Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm Complete all as specified and directed.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 5 Nos of 30cm wide circular bands alternate with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Supply & laying unburnt locally available bricks class B for Cable protection suitable for LT UG cable of standard size Complete all as specified and directed..
M &L local river sand for bedding sand cushioning of all LT UG cable Complete all as specified and directed. Note:- Punned thickness shall be measured and paid.
M&L for PCC (1:2:4) type B2 with using 40mm graded aggregate as in foundation and mass filling concrete including well finishing by using cement plastering 1:4 for LT poles coping complete all as specified and directed.
M&L for PCC (1:3:6) type C2 with using 40mm graded aggregate as in foundation and mass filling concrete for LT poles foundation and complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 1100Volts grade of size 16 Sqmm 4core complete all as specified and directed. Note 1 : Rates incl taking out of old UNSV cable from trench/ground where ever directed. Note 2 :- Earth work and excavation shall be measured and paid separately.
Labour only for Repairing of chain and motor of high mast light including rewinding of motor, greasing of gears and chain, replacing chain housing and associated works Complete all as specified and directed.
Supply and install feeder pillar box suitable for high mast light, factory made, cubicle type, out door type double door, locking arrangements, made up of MS sheet of min 3mm thickness, CRCA FRP proof, zinc coated, 7 tank wahsed, including spraying light smoke grey weather proof mettalic paint with RYB indicators, 100Amp capacity Aluminium bus bar, 01 x TPN MCB 63 Amp, suitable cable jointing arrangements etc mounting channels made up of MS angle, Complete all as specified and directed.. Drawing and make shall be approved by GE before installtion at site.
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 1100Volts grade of size 50 Sqmm 3.5core complete all as specified and directed. Note 1 : Rates incl taking out of old UNSV cable from trench/ground where ever directed. Note 2 :- Earth work and excavation if required shall be measured and paid separately.
M/S RAJESH MISHRA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .