Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAdmitted-Finance | ₹12.3 L | L1 | Admitted-Finance |
| 2 | L2₹12.5 LAdmitted-Finance | ₹12.5 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical EMD/FDR Not Submitted |
| 4 | Rejected-Technical | - | - | Rejected-Technical EMD/FDR Not Submitted |
| 5 | Rejected-Technical | - | - | Rejected-Technical EMD/FDR Not Submitted |
| Sl No | Description | Qty | Unit | ARIHANT ENGINEERS AND TRADERS L2 | balram associates L1 |
|---|---|---|---|---|---|
| 1.00 | SITC of Ultrasonic water Level transducer IP 67 with LCD Display suitable for Underground reservoir/ sump tank with Ultrasonic sensor for observing the water depth in meters/feet. The system is operated on 12 to 28 V DC (0.1 A surge) & the ultrasonic sensors operate on 4-20 mA. Measurement Accuracy 0.25% of measuring range, temperature range -40 to + 70 Deg C, sensor material and housing in Aluminium ((ECTFE) and PP/PVDF respectively. The process Indicator / controller having 4 relay outputs, Contact rating 230 VAC, 1 amp. The system should be configurable as control outputs on separate set Points, with predefined logic with 7 segments LED, 5 digits. Supported by 4 key tack-tile keyboards. The system will have 4 relay outputs; contact rating 230 VAC, 1 amp. Configurable as control outputs on separate set points, with predefined logic, Input will be 4-20 mA Linear with resolution 4% "digit. The Supply will be 230 VAC 50 Hz & Power Output of 24 VDC 120 mA. Power supply is made available for the external transmitter supply. The controller should be capable of giving out alerts through alarms to users if the water level in any of the tanks being monitored crosses the defined threshold value. The controller should have inbuilt power backup system. Provision should also be there to connect to secondary controller for giving the same output at both the places. The controller should also give backup battery charge percentage. Suitable length of power cable and signal cable should also be provided along with canopy for Sensor and MS encl. for display.
Make:- EIP/Skope/ vega/ Siemens/ Any DJB approved.. | 2 | Sets. | 10,60,000 ₹12,50,800 | 10,40,000 ₹12,27,200 |
Tender Value
Refer Docs
EMD Value
₹24,800
Closing Date
28 Feb 2026, 3:00 pmClosed
EXECUTIVE ENGINEER (EM) M-11
GREATER KAILASH, PART-I, NEW DELHI
SITC of ultrasonic water level indicator at Siddhartha Enclave BPS and Siddhartha Extension BPS under Jangpura Constituency AC-41.
2026_DJB_287462_25
NIT No. 29/EE(EM)M-11/(25-26)
Open Tender
Electrical Work/ Equipment
30 days
EXECUTIVE ENGINEER (E/M) M-11
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹24,800
Yes
11 Mar 2026
21 Feb 2026
28 Feb 2026
21 Feb 2026
28 Feb 2026
21 Feb 2026
SITC of Ultrasonic water Level transducer IP 67 with LCD Display suitable for Underground reservoir/ sump tank with Ultrasonic sensor for observing the water depth in meters/feet. The system is operated on 12 to 28 V DC (0.1 A surge) & the ultrasonic sensors operate on 4-20 mA. Measurement Accuracy 0.25% of measuring range, temperature range -40 to + 70 Deg C, sensor material and housing in Aluminium ((ECTFE) and PP/PVDF respectively. The process Indicator / controller having 4 relay outputs, Contact rating 230 VAC, 1 amp. The system should be configurable as control outputs on separate set Points, with predefined logic with 7 segments LED, 5 digits. Supported by 4 key tack-tile keyboards. The system will have 4 relay outputs; contact rating 230 VAC, 1 amp. Configurable as control outputs on separate set points, with predefined logic, Input will be 4-20 mA Linear with resolution 4% "digit. The Supply will be 230 VAC 50 Hz & Power Output of 24 VDC 120 mA. Power supply is made available for the external transmitter supply. The controller should be capable of giving out alerts through alarms to users if the water level in any of the tanks being monitored crosses the defined threshold value. The controller should have inbuilt power backup system. Provision should also be there to connect to secondary controller for giving the same output at both the places. The controller should also give backup battery charge percentage. Suitable length of power cable and signal cable should also be provided along with canopy for Sensor and MS encl. for display. Make:- EIP/Skope/ vega/ Siemens/ Any DJB approved..
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.65 MB
BOQ_380964.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid