Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.2 L+₹76,306 (8.07%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L2 | Rejected-Finance L2 | |
| 3 | L3₹10.9 L+₹1.4 L (15.1%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L3 | Rejected-Finance L3 | |
| 4 | L4₹11.9 L+₹2.4 L (25.4%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L4 | Rejected-Finance L4 | |
| 5 | L5₹12.0 L+₹2.5 L (26.9%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹15.5 L
EMD Value
₹31,000
Closing Date
3 Feb 2021, 6:00 pmClosed
GE AF FARIDABAD
Garrison Engineer AF Faridabad Dabua Colony Faridabad Haryana Pin-121005
REPAIR MAINT OF LT UG CABLE LT PANELS LT POLES DG SETS AND REPAIR MAINT TO CERTAIN BLDGS AT AF STN FARIDABAD
2021_MES_412632_1
GE (FBD)/AF-38/2020-2021
Open Tender
Civil Works
Item Rate
180 days
AF STSTION FARIDABAD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF FARIDABAD
₹31,000
Yes
26 Feb 2021
14 Jan 2021
5 Feb 2021
14 Jan 2021
3 Feb 2021
21 Jan 2021
15 Jan 2021 - 20 Jan 2021
Amount
Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed by Engr-in-Charge.
Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart Complete all as specified and directed by Engr-in-Charge.
Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Material and labor for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable complete all as specified and directed by Engr-in-Charge.
Supply of brick sub class 'B' laid dry in trenches in repairs over the cable adjoining each other width wise for cable protection complete all as specified and as directed by the Engineer-in -Charge
Supply,Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 50 Sqmm 3.5core .Complete all as Specified and Directed by Engr-In-Charge.
All as above item No 6 But Size 35 sqmm 4 core complete.All as specified and directed by Engr-In-Charge.
All as above item No 6 But Size 25 sqmm 4 core complete.All as specified and directed by Engr-In-Charge.
All as item No 6 above But Size 16 sqmm 4 core complete.All as specified and directed by Engr-In-Charge.
All as item No 6 above But Size 10 sqmm 4 core complete.All as specified and directed by Engr-In-Charge.
Laying only cable 120 Sqmm 3.5 Core complete all as specified and directed by Engr-in-Charge.
Laying only cable 95 Sqmm 3.5 Core complete all as specified and directed by Engr-in-Charge.
Laying only cable 70 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
(Note : Cable of size 120Sqmm,95 Sqmm and 70 Sqmm will be issued as Sch B free for fixing and only materal for excavation, earth work, sand and bricks will be paid for the same)
Supply and Fix cable jointing kit,heat shrink type for 1100 volts grade,XLPE insulated armoured heavy duty electric cable with aluminium conductor,cross sectional area 6-16 Sqmm 4 core complete with jointing material and accessories including testing all as specified ans as directed by Engr In charge.
All as above item No 15 But Size 25-35 sqmm 4 core complete all as specified and directed by Engr-in-Charge.
All as above item No 15 But Size 50-95 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
All as above item No 15 But Size 120 - 185 qmm 3.5 core complete all as specified and directed by Engr-in-Charge.
S & F in repairs Earth test box made of powder coated, 3.15 mm thick, CRCA sheet,20 cm x 20 cm x 10 cm size conforming to CPRI approved and IP-65 protection class,right hinge openable type including mounting arrangement such as making hole in wall,providing MS clamp,nut,bolt etc complete manufactured through approved manufacturers complete all as specified and directed by Engr-in-Charge. Make: SMS/Universal/L&T
S&F in repairs GI strip 25 mm x 4 mm Earth continuity conductor fixed to wall/roof/trenches etc., and inculding base insulators fixed on walls,roof etc.Complete all as specified and Directed by Engr-In-Charge.
S&F in repairs MCCB 3 pole 415 volts fixed type 160 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed by Engr-in-Charge. ,Havells/L&T/C&S
S&F MCCB 3 pole 415 volts in repairs,fixed type 25 Amps to100 Amps with braking capacity 16 KA after taking out old U/S one complete all as specified and directed by Engr-in-Charge.Make: Havells/L&T/C&S
S&F in repairs MCCB 3 pole 415 volts fixed type 200 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed by Engr-in-Charge. ,Havells/L&T/C&S
S&F in repairs MCCB 3 pole 415 volts fixed type 250 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed by Engr-in-Charge. ,Havells/L&T/C&S
S&F in Repairs Contactor, (4 Pole AC & DC Control) operational current AC1,160 Amps,poles composition- 4NO,DC control ref-LP1D80004 of TC complete all as specified and as directed by Engr In Charge.
S&F in Repairs Contactor, (4 Pole AC & DC Control) operational current AC1,125 Amps,poles composition- 4NO,DC control ref-LC1DT125A of TC complete all as specified and as directed by Engr In Charge.
S&F in repairs,3 pole contractor,40 Amps,2 No+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1 , including after taking out old unserviceable one, complete all as specified and as directed by Engr In Charge. Make:- CAT Part No-SS90701 of L&T or equivallent model and make in C&S / CE.
S&F in repairs digital volt meter ,415 volts,including after taking out old unserviceable one all as specified ans as directed by Engr-In-Charge.Make: AE/C&S/ABB
S&F in repairs digital Ammeter,415 volts grade,100 Amps rating,including and after taking out old unserviceable one all as specified and as directed by Engr-In-Charge.AE/C&S/ABB
S&F in repairs indoor cast ring type low tension current transformers of current ratio 100/5A including and after taking out old unserviceable one complete all as specified and as directed by Engr-In-Charge.
All as mentioned in item No 30 here in above but ratio 200/5 A complete all as specified and as directed by Engr In Charge.
All as mentioned in item No 30 here in above but ratio 300/5A complete all as specified and as directed by Engr In Charge.
M & L replacement of cable PVC insulated unarmored for connection 2.5 sqmm x 3 core Copper conductor duly drawn MS conduit 20 mm dia from junction box to street light fittings on pole including PVC flexible pipe of suitable sizebfrom top of steel conduit to light fitting complete all as specified and directed by Engineer-In -Charge.
M & L for High quality powder coating on electric panels (Cubicle) installed at different places with synthetic enamel paint of suitable colour including and after scrubbing all body surface to get all foreign particles removed off,applying one coat of metal primer by disconnecting,removal of all accessories like bas bar, CTs,MCCBs and all wirings,equipments and refix with new Gun metal nut,bolt and washer complete with new copper lead wiring all as specified and directed by Engineer-in Charge.
Repair/maint of Diesel engine sets 160 KVA capacity ,Checking and servicing of engine for smooth running, its unusual sound and color of smoke from exhaust and set it right in case of deviations, Checking and repairing the leakage of fuel, lubricating oil and coolant,Setting of Valves tappets whenever required.Checking and repairing of Accessories drive, Turbo Charger and crankshaft endplay,Checking alignment of Engine and Alternator,Checking of throttle control & its setting,Checking of instrument on instrument panel,Checking of rotating diodes assembly in brushless alternator,Checking of wiring system and repairing if required,Repair and Maintenance of Relays including contactors in control panel. Checking and cleaning of battery terminal and de-sulphation. Diagnosis of faults in engine and Alternator and its rectification. Checking Self Starter and accessories all as specified and as directed by Engr-In-Charge. Note: Cost of unserviceable items will be measured and paid seperately as supply only under relevant items nemtioend here in after.
All as mentioned item No 35 here in above but capacity of DG set 100 KVA complete all as specified and as directed by Engr In Charge.
All as mentioned item No 35 here in above but capacity of DG set 82.5 KVA complete all as specified and as directed by Engr In Charge.
All as mentioned item No 35 here in above but capacity of DG set 62.5 KVA complete all as specified and as directed by Engr In Charge.
All as mentioned item No 35 here in above but capacity of DG set 50 KVA complete all as specified and as directed by Engr In Charge.
All as mentioned item No 35 here in above but capacity of DG set 30 to 40 KVA complete all as specified and as directed by Engr In Charge.
Supply only of following parts during B Check Diesel engine generator Service suitable for Generator set mentioned in item No 35 to 40 complete all as specified and as directed by Engr In Charge. (i) Fuel Filter for capacity of DG set 160 KVA
(ii) Fuel Filter for capacity of DG set 100 KVA
(iii) Fuel Filter for capacity of DG set 82.5 KVA
(iv) Fuel Filter for capacity of DG set 62.5 KVA
(v) Fuel Filter for capacity of DG set 50 KVA
(vi) Fuel Filter for capacity of DG set 30 to 40 KVA
(i) Lubricating Oil Filter for capacity of DG set 160 KVA
(ii) Lubricating Oil Filter for capacity of DG set 100 KVA
(iii) Lubricating Oil Filter for capacity of DG set 82.5 KVA
(iv) Lubricating Oil Filter for capacity of DG set 62.5 KVA
(v) Lubricating Oil Filter for capacity of DG set 50 KVA
(vi) Lubricating Oil Filter for capacity of DG set 30 to 40 KVA
(i) By pass Filter for capacity of DG set 160 KVA
(ii) By pass Filter for capacity of DG set 100 KVA
(iii) By pass Filter for capacity of DG set 82.5 KVA
(iv) By pass Filter for capacity of DG set 62.5 KVA
(v) By pass Filter for capacity of DG set 50 KVA
(vi) By pass Filter for capacity of DG set 30 to 40 KVA
(i) Air Filter for capacity of DG set 160 KVA
(ii) Air Filter for capacity of DG set 100 KVA
(iii) Air Filter for capacity of DG set 82.5 KVA
(iv) Air Filter for capacity of DG set 62.5 KVA
(v) Air Filter for capacity of DG set 50 KVA
(vi) Air Filter for capacity of DG set 30 to 40 KVA
Coolant
Lubricating Oil
Supply and fixing in repair IOPS Module digital display unit Model No 47534753 suitable for exisitng KOEL engine DG Set complete all as specified and as directed by Engr In Charge.
Dismantling of concrete poles/Struts, any size alongwith GI bracket and fittings of any size and junction boxes complete all as specified and as directed by Engr In Charge.
M&L for painting of steel tubular swaged pole 9 meter long on pole surface with two coat of synthatic enamelled paint on pole surface complete all as specified and directedby Engr-In-Charge.
Boring of Holes under road, Pavement, hard Standing by trenchless technology using ultra Sound technique and necessary machine with HDPE Pipe, PN 10,100 mm dia all as specified and as directed by Engr-In-Charge. (To be measured only when cable rerouted).
M&L for earthing complete for pole with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected by using galvanised iron strip 25 X 4mm as earthing lead size by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 40mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified & as directed by Engr-in-Charge.
All as mentioned in item No 46 here in above but work to be carried out replacement of existing U/S earting with using earthing lead of galvanised iron strip of 32 X 6 mm size complete all as specified and as directed by Engr In Charge.
Supply and fixing in repairs lightning arrestor expulsion type complete with all fitting ,transmission class,discharge capacity up to 65 Kilo Amps HT 11 KV ,10 KA station class.Shall comply with the requirements of routine test as specified in the relevant IEC:99-4 & IS:3070 (Part - III) complete all as specified and as directed by Engr In Charge.
M&L for replacement of U/S earting strip of size 32x6 mm complete all as specified and as directed by Engr In Charge.
M&L for replacement of U/S earting strip of size 25x4 mm complete all as specified and as directed by Engr In Charge.
Supply, laying and fixing in position in repairs galvanized iron pipe 80 mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches duly painted with two coat of black metallic paint after a primer coat of red oxide complete all as Specified and Directed by Engr-In-Charge.Make : Jindal/Tata/Prakash Surya
All as per item No 51 here in above but 50 mm dia complete all as specified and directed by Engr-In-Charge.
All as per item No 51 here in above but 40 mm dia complete all as specified and directed by Engr-In-Charge.
Taking Down carefully Copper/aluminium Point Wiring (light, fan,socket or Power) complete,(fittings such as switches, ceiling roses, pendents, regulators sockets etc, to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc. complete all as specified and directed by Engr-In-Charge.
Taking down carefully aluminum two core sub main wiring of sizes 6 Sqmm /4 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed by Engr-In-Charge.
M&L point wiring with 1.5 Sqmm (Nominal area) PVC insulated and unsheathed single core cable 1100 Volts grade with stranded copper concuctor in and including PVC concealed conduit and conduit accessories along with continuous earth wire 1.5 Sqmm PVC insulated, unsheathed stranded copper conductor cable and connected to common earth dolly, with and including modular pressed steel sunk box suitable sizes for fixing of modular switches fan regulators complete with all accessories for one light point/bell point /Fan point controlled by one ,one way switch complete all as specified and directed by Engr-In-Charge.
All as per Item No 58 mentioned here-in- before but one three pin 5 Amps socket out let on the same board with other switches with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete all as specified and directed by Engr-In-Charge.
All as per item No 58 mentioned here-in- before but one three pin 5 Amps socket out let on independant board with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete all as specified and directed by Engr-In-Charge.
All as per item No 58 mentioned here-in- before but 15 Amps 3 pin socket outlet on independent board with 2.5 sq mm PVC insulated and sheathed copper conductor with 2.5 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engr-In-Charge.
S&F modular switches 1 way, 6 Amp, 1 module complete all as specified and directed by Engr-In-Charge.
S&F socket modular 6A-2/3 pin combined with 2 module complete all as specified and directed by Engr-In-Charge.
S&F switch modular 1 way, 16 Amp, 1 module complete all as specified and directed by Engr-In-Charge.
S&F socket modular 16A-2/3 pin combined with 2 module complete all as specified and directed by Engr-In-Charge.
S&F modular fan regulator, stepped type 120W, 2 module complete all as specified and directed by Engr-In-Charge.
S&F in repairs,sheet metal enclosure for MCCB DB's TPN 4 Way, 415 volts with neutral bus bar 200 Amp rated double door including MCCB 63 Amp, 10 KA, incomming, and suitable for MCB SPN/SP outgoing complete all as specified and directed. all as Specified and Directed by Engr-In-Charge.Make- .Make: Havells/Standrad/Anchor
S&F in repairs,MCB SP 5-32 Amps,"C" series 240 Volts complete all as specified and directed by Engr-In-Charge..Make: Havells/Standrad/Anchor
S & F in repairs,MCB SPN 40 Amps,"C" series 240 Volts complete all as specified and directed by Engr-In-Charge. Make: Havells/Standrad/Anchor
S & F Sheet metal Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 V complete all as specified and directed by Engr-In-Charge.
S&F in repairs,ceiling rose surface backlight, 65 x 50 mm three terminals complete all as specified and directed by Engr-In-Charge. .Make Anchor/Plaza/ Standard.
M&L in repairs,two single core PVC insulated cable with copper conductor multi stranded 6 Sqmm in and incl. duly drawn through and including concealed PVC conduit suitable size as sub main with continuous earth wire 6 Sqmm size and connecting to common earth dolly all complete all as specified and directed by Engr-in-charge.(Flexible Copper Wire Used In FRLS)
All as per item No 72 mentioned here-in- before but 4.0 sq mm PVC insulated and sheathed copper conductor with 4 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engr-In-Charge.
S&F in repairs LED light fitting,18 Watt,6000K (4 ft.),Wall mounted,diffused batten type, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver,life of 30000 burning hours,No UV and IR radiations connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size for connecting with ceiling rose all as specified and directed by Engr-in-charge,
S&F recessed mounting edgelit slim LED panel light 40W 2x2" powder coated PDC aluminium body and high quality LGP & PMMA diffuser with seperate driver mounted square fixture in white finish with and separate electronic driver,life of 30000 burning hours,No UV and IR radiations suitable for low depth ceiling complete with all accessories, internally pre-wired including three core twisted flexible copper conductor of suitable size for connecting with ceiling rose all as specified and directed by Engr-in-charge
S&F in repair energy efficient LED building secruity lights 1x30W with lens, PDC aluminium body and clear glass LED lens for wide beams distributions efficay >100 Lm/W, CCT 5700K, IP-65 complete with bracket nut bolts and washers suitable for fitted in building complete all as specified and directed by Engr-In-Charge.
S&F exhaust fan 300mm sweep, metal body heavy duty with louvers complete with making suitable hole and fixing accessories complete all as specified and directed by Engr-In-Charge.
M & L for earthing complete with galvanised steel earth plate electode 600 x 600 x 6.0 mm thick burried directly in ground earth pit not less than 2.25 mtr deep below ground level connected to & including galvanised steel wire 4.0 mm dia size means of nuts and bolt check nuts and washers of galvanised rion sheet all as shown in electrical plate Nos 5 of SSR Part - I and connected to earthing test point complete including testing filling of adquate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil upto 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made out of 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed by Engr-In-Charge.
Saini Enterprises
Singh Associates
M/S Anand Enterprises
laxmi enterprises
Parveen Builders
H.B. Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .