| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repair / maintenance of internal light fitting of any type like tube lights / wall bracket light fittings / ceiling lights / bulk head light / mirror lights etc in its position, testing all the components / parts, wiring etc, identifying and replacing the defective components like tube rod, side holders, holders, lamps etc complete all as specified and as directed.Note: (i) The rate against the above mentioned item is deemed for cost of labour only. (ii) Cost of spares like capacitor, lamp holder, connector, connection wire etc. replaced against above mentioned item will be measured & paid separately under respective items of Sch 'A' here-in-below. (iii) The contractor's representative (supervisor) will report to concerned JE E/M at 0900hrs daily to collect the list of complaints and will submit the completion report on the same day before 1700hrs to the JE E/M. (iv) The contractor shall address all the given complaints within 24 hours from the time the list of complaints is handed over to him / his rep by the concerned JE E/M. In case the complaint is not addressed for whatsoever reason within the specified time limit (48 hrs), an amount of Rs 100/- per such complaint per day will be recovered from the amount due to him through RAR / Final Bill.The contractor shall engage separate team of technicians / repairer for each at SQN AREA B Zone (04 x teams). (v) The contractor shall maintain proper record of repair / maint in a binded compliant register and complaint slip books duly signed by the user and bringing out the details of spares replaced and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings with the concerned JE E/M against the supply only items here-in-below. (vii) During the contract period, if the same complaint is repeated, it will be regarded as a single complaint, and no additional payment will be made for addressing the repeated issue. | 1,600 | Each | - | - |
| 2 | Taking down carefully old unserviceable copper/aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets,sunken type box etc.and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification complete all as specified and directed . | 645 | Point | - | - |
| 3 | Taking down copper / aluminium concealed sub main wiring complete with all fixture and fittings including cutting chasing as required and making good the disturbed surfaces including finishes to match with adjacent surfaces of walls, floors, etc. complete all as specified and as directed. | 850 | RM | - | - |
| 4 | M&L repair of point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for One light/Fan point controlled by one way switch 6 Amps 240 volts. | 250 | Point | - | - |
| 5 | M&L repair of point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for one 3 / 5 Amps socket outlet point on independent board. | 200 | Point | - | - |
| 6 | M&L repair of point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for one 3 / 5 Amps socket outlet point on same board. | 10 | Each | - | - |
| 7 | M&L repair of point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for one light point controlled by two 2 way switch | 5 | Point | - | - |
| 8 | M&L repair of point wiring with 2.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 2.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for one 15 Amps socket outlet point on independent board | 100 | Point | - | - |
| 9 | M&L repair of point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type one bell/ buzzer point controlled by one push button on the same board with other switches or independent. | 80 | Each | - | - |
| 10 | M & L for sub main wiring with 2 runs of 1.5 sqmm main wire along with 1 run of 1.5 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit/casing caping (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces and including taking down complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. | 100 | RM | - | - |