Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC | ₹1.0 Cr | L1 | Accepted-AOC The lowest e-tenderer |
| 2 | L2₹1.1 Cr+₹4.0 L (3.77%)Rejected-Finance 302 SIDDHIVINAYAK APPT A WING MUMBAI K K MARG JACOB CIRCLE MUMBAI CITY MAHARASHTRA 400 011 | MUMBAI | MAHARASHTRA | 400011 | ₹1.1 Cr+₹4.0 L (3.77%) | L2 | Rejected-Finance Not the lowest e-tenderer |
| 3 | L3₹1.1 Cr+₹6.0 L (5.76%)Rejected-Finance | ₹1.1 Cr+₹6.0 L (5.76%) | L3 | Rejected-Finance Not the lowest e-tenderer |
| 4 | L4₹1.2 Cr+₹11.6 L (11.1%)Rejected-Finance | ₹1.2 Cr+₹11.6 L (11.1%) | L4 | Rejected-Finance Not the lowest e-tenderer |
| 5 | L5₹1.3 Cr+₹21.3 L (20.3%)Rejected-Finance S NO 41 4K JAIHIND SOCIETY GANESH NAGAR NEAR ANAND PARK VADGAON SHERI PUNE 411 014 | PUNE | PUNE | MAHARASHTRA | 411014 | ₹1.3 Cr+₹21.3 L (20.3%) | L5 | Rejected-Finance Not the lowest e-tenderer |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
28 May 2021, 6:00 pmClosed
Col Santosh Pandey CWE (A) Mumbai
Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
ADDITION / ALTERATION TO BUILDING NO P- 2, 3, 4, 5, 6, 11, 14, 16 AND 17 AT ALTINHO (GOA)
2021_MES_439605_1
84032/P/E8
Open Tender
Civil Works
Item Rate
270 days
GE PANAJI GOA
Please Refer The Tender Documents
7 documents required · 7 mandatory
₹1,000
GE PANAJI GOA
₹2.1 L
12 Jul 2021
30 Apr 2021
29 May 2021
30 Apr 2021
28 May 2021
16 May 2021
30 Apr 2021 - 21 May 2021
Amount
Dismantling asbestos cement (Corrugated or semicorrugated) sheets in roof coverings.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated sheet sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. Make : (i) TATA (ii) JSW (iii) ESSAR (iv) HINDALCO (v) INDALCO (iv) ASSOCIATED PROFILES AND ALUMINIUM LT
S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. Make : (i) TATA (ii) JSW (iii) ESSAR (iv) HINDALCO (v) INDALCO (iv) ASSOCIATED PROFILES AND ALIMINIUM LT
Dismantling of wrought iron or mild steel work of any description not otherwise provided as specified and directed.
S&F for rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates of Fe 410-W (Gde E-250) quality A complete all as specified and directed.
M&L for Preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer on surface of any description over 10cm width or girth complete all as specified and directed.
M&L for Preparation of old steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer on surface of any description over 10cm width or girth complete all as specified and directed. Make for item No 06 & 07 : (a) LUXOL (Berger paint) (b) BROLAC (Jhonson & Nicholson) (c) SUPERLAC (Shalimar paints) (d) NEROLAC (Goodlass Nerolac) (e) APCOLITE (Asian Paints).
Demolition of wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified.
Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200mm/600mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. The Main Runners to be placed @ 1200mm, The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600mm x 600mm. Grid of module size 600mm x 600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit complete as specified & directed by Engineer-in-charge. Make : (a) Everest (b) Armstrong
S & F 6 mm thick calcium silicate board made with calcareous & siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sqcm, bending strength 100 kg/sqcm, tapered edge, fixing to ceiling section and perimeter channel using dry wall screws of size 3.5 mm X 25 mm at 230 mm c/c including jointing and finishing to a flush finish of tapered edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint complete all as specified and as directed. Make : (a) Everest (b) Armstrong (c) Supra (d) Hilux (e) RAMCO (f) Deckelite India
Demolition of brick/stone masonry walls built in cement mortar including all quoins, arches, pillars, retaining walls etc. complete all as specified and directed by Engineer in charge.
Material and labour for bricks work with sub class ' B ' bricks, straight or curved on plan, exceeding 6m means radius with old size bricks built in cement mortar 1:4 complete all as specified and directed by Engineer in charge.
Taking down cement or cement lime plaster in any description including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed by Engineer in charge.
M & L rendering 15mm thick on stone masonry surface or surface other than fair face of brickwork or on one side of lathing in CM 1:6 without using extra cement.
M & L rendering 15mm thick on stone masonry surface or surface other than fair face of brickwork or on one side of lathing in CM 1:4 without using extra cement using water proofing compound. Note : water proofing compound will be measured seperatly.
Supply only integral water proofing compound Make - (a) Pidilite Industries Ltd Taloja (b) FOSROC (c) Dr Fixit
M&L for Preparation of new plastered surfaces of any description and applying two coats of cement base paint over a coat of alkali resistant primer on walls complete all as specified and directed. Make : (a)Super Snowcem (b) Duracem (c) Aquacem (d) Shalimar 5 Berger
M & L for two coat of oil bound distemper over a coat of wall care puty on plastered surfaces of walls including preparation of new surface. Make- (a) Nerolac (b) Berger Paints (c) ICI India (d) Asian Paints(Tractor Brand)
S & F Galvanished mild steel wire cloth, in repair 0.63mm nominal dia of wire and average width of aperature 1.40mm and fixed with tinned tacks, or galvanished wire staples all as specified
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings etc and removing unserviceable materials from site of work after credit for the same is recovered by the dept and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed by Engineer-in- Charge
Taking down carefully UNSV main switch and DB's including MCB's of any size, make, type and capacity and desposting at site as directed.
Taking down carefully UNSV submain wiring and DB's including MCB's of any size, make, type and capacity and desposting at site as directed.
M & L for Point wiring with 1.5 sq mm, PVC insulated unsheathed (FRLSH), 1100 volts grade,congorming IS-694 1.5 Sqmm(nominal area) multi-stranded copper conductor, in and including rigid non-metallic PVC heavy duty conduit (ISI mark), 19/ 20 mm dia or higher size as required at site including cutting chases for conduits, sinking for boxes for concealed conduit wiring or on surfaces of trusses by means of saddles & clips etc with all fittings and accessories with 16 SWG factory made pressed steel sunken box, totally concealed in wall with 3mm thick industrial laminated sheet top cover, fixed flush with wall surfaces by means of brass screws and sunk/ cup weashers for mounting of switches, sockets, fan regulators etc including unsheathed (FRLSH) single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to mettalic bodies of luminaries/fan etc at one end to common earth dolly at other end and making good to the disturbed surfaces to match the existing surfaces complete (fill up cement in gaps, finishing with putti and apply two coats of paint, match with existing colour in disturbed surface area), as per IS specification and as specified in SSR Part-I complete all as specified and directed by Engineer-in- Charge for : (a) One light point / Fan point, bell point controlled by one , one-way switch.
All as above item No-23 but, One switch socket outlet 3 pin 5amps, on same board.
All as above item No-23 but, One switch socket outlet 2/3 pin 5 Amps , on independent board.
All as per item no 23 above but with 2.50 Sqmm PVC insuklated FRLS, multistranded copper conductor cable 1100 V grade for one 3 pin , 5/15 Amps sw3itch socket outlet on independent board complete all as specified and directed. Make for Item No. 23 to 26: Cable -(i) Havells (ii) Finolex (iii) Nicco (iv) Plaza (v) Anchor (vi) Polycab (vii) RPG (viii) GLOSTER (ix) RR Kabel(x) KEI PVC Conduit : (i) Anchor (ii) Modi (iii) Presfit (iv) Precision (v) Astral
S & F modular Switch 1 way 6 Amp, module.
S & F modular Switch 1 way 16 Amp, module.
S & F modular Socket 6A-2/3 pin combined 2 module.
S & F modular Switch 6A/16A -2/3 pin combined 2 module.
S & F modular fan regulator 120 W - 2 module.
S & F white cover Plate with frame 3 module.
S & F white cover Plate with frame 6 module.
S & F Metal Flush Box 3 module.
S & F Metal Flush Box 6 module.
S &F ceiling rose surface bakelite 65 x 50 mm, two to three terminals complete all as specified and directed.
S & F bell switch including bell ding dong one way, 240 Volts AC ISI marked.
M & L for lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings Makes for item No 27 to 38 : (i) Anchor (ii) Crabtree (iii) Leader (iv) Legrand (v) Havells (vi) C & S Electric Ltd.
M & L for Submain wiring complete with and including 2 runs of 6 sqmm single core FRLSH PVC insulated and unsheathed multistranded copper conductor cable single core 1100 Volts grade and multistranded copper conductor cable of 6 sqmm drawn through and including heavy grade PVC casing caping of suitable size, fixed to of dia 19/ 20 mm dia or higher size as required at site totally concealed in walls/floors/ceiling or on surfaces of trusses by means of saddles & clips etc including all acessories / fitting / junction box / inspection covers etc of heavy grade, ISI marked with one run of 4.0 Sqmm PVC insulated FRLS, unshethed multistranded copper conductor cables as a continuous earth wire complete all as specified. Note : 2 runs of 6 sqmm single core copper cable and one run of 6.0 Sqmm of Earth conductor cable with casing capping will be measured and paid as one .
M & L for Submain wiring complete with and including 2 runs of 4 sqmm single core FRLSH PVC insulated and unsheathed multistranded copper conductor cable single core 1100 Volts grade and multistranded copper conductor cable of 4 sqmm drawn through and including heavy grade PVC casing caping of suitable size, fixed to of dia 19/ 20 mm dia or higher size as required at site totally concealed in walls/floors/ceiling or on surfaces of trusses by means of saddles & clips etc includin all acessories / fitting / junction box / inspection covers etc of heavy grade, ISI marked with one run of 4.0Sqmm PVC insulated FRLS, unshethed multistranded copper conductor cables as a continuous earth wire complete all as specified. Note : 2 runs of 4 sqmm single core copper cable and one run of 4.0 Sqmm of Earth conductor cable with casing capping will be measured and paid as one .
M & L for Submain wiring complete with and including 4 runs of 10 sqmm single core FRLSH PVC insulated and unsheathed multistranded copper conductor cable single core 1100 Volts grade and multistranded copper conductor cable of 10 sqmm drawn through and including heavy grade PVC casing caping of suitable size, fixed to of dia 19/ 20 mm dia or higher size as required at site totally concealed in walls/floors/ceiling or on surfaces of trusses by means of saddles & clips etc includin all acessories / fitting / junction box / inspection covers etc of heavy grade, ISI marked with one run of 10 Sqmm PVC insulated FRLS, unshethed multistranded copper conductor cables as a continuous earth wire complete all as specified. Note - 4 runs of 10 sqmm single core copper cable and one run of 10.0 Sqmm of Earth conductor cable with casing capping will be measured and paid as one . Make for Item No.39 to 41: Cable -(i) Havells (ii) Finolex (iii) Nicco (iv) Plaza (v) Anchor (vi) Polycab (vii) RPG (viii) GLOSTER (ix) RR Kabel(x) KEI PVC Conduit : (i) Precision (ii) Modi (iii) Presto Plast (iv) Supreme (v) Polycab (vi) Plaza (vii) Pressfit (viii) ASTRAL
S & F LED batten Tube Light , light fittings 20 Watt and fixed with wall surface with anodizes extruded aluminium housing, high transmissitivity diffuser and lumin output and connecting with 3 core flexible copper cable PVC insulated complete all as specified and directed. Bajaj Cat part No BCLSB 20 WH or equivalent. Make:- Havells Delite Plus Tube Set , Model No. LHEXBTP7IN1S022 or in equivalent model in WIPRO / Philips/ GE/ BAJAJ
S & F LED batten Tube Light , light fittings 10 Watt and fixed with wall surface with anodizes extruded aluminium housing, high transmissitivity diffuser and lumin output and connecting with 3 core flexible copper cable PVC insulated complete all as specified and directed. Bajaj Cat part No BCLSB 10 WH or equivalent. Make:- Havells Delite Plus Tube Set , Model No. LHEXBTP7IN1S022 or in equivalent model in WIPRO / Philips/ GE/ BAJAJ
S & F LED flood light luminaries 60 Watt with ultra sleek, light weight with secondary optics made up of pressure die cast housing totally enclosed IP 66 in gress protection and impact resistance of IK 07 pressure Dia Cast aluminium housing 4 KV inbuild and 10 KV external surge protection complete with all other accessories, all as specified and directed. Bajaj Cat No BJLF 60 Watt LED 1 or equivalent.. Make:- Havells Delite Plus Tube Set , Model No. LHEXBTP7IN1S022 or in equivalent model in WIPRO / Philips/ GE/ BAJAJ
Refixing of existing old tube light fitting comppletely including making connection with copper flexible wire 2 core 23/0.0076 from ceiling rose to fitting complete (old tube light fitting shall be re-use).
S & F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps
S & F IP-42 protection distribution board, SPN 8 ways, 240 Zvolts, sheet steel, powder coated, double door system , fitted with two cover suitable for use on 240 volts, 50HZ with 200 Amps rated bus bar, neutral link each bar and din rail complete all as specified and directed.
S & F IP-42 protection distribution board, TPN 4 ways, 240 Zvolts, sheet steel, powder coated, double door system , fitted with two cover suitable for use on 240 volts, 50HZ with 200 Amps rated bus bar, neutral link each bar and din rail complete all as specified and directed.
Supply and Fixing Isolator TPN 415 Volts 63 Amps.
Supply and Fixing Isolator SPN 6 to 40 Amps 240 Volts.
Supply and Fixing MCB SP 6 to 32 Amps 240 Volts, 15 Hz, 10 KA suitable for lightening load capacity 6 to 32 Amps.
Supply and Fixing load line DB double door including MCCB 100 Amps including dismantaling of existing panel of wall and fixing new load line box doing the existing connection in new load line with SP , SPN , TPN , (SP,SPN,TPN measured and paid seperatly ) plaster with necessary bricks and cement required at site and matching the existing surface with colour including in unit rate. NOTE for Item no. 46 to 52 Make: (i) Larsen & Tubro (ii) Siemens (iii) Schneider (iv) ABB (v) Havells (vi) Legrand (vii) Indo ASIAN (viii) C & S Electric
M & L in repairs for earthing complete with galvanized steel plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 deep below ground level with top edge of the plate not less than 1.50 m below ground level, surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt , filling in alternate layer and electrode connections by using to galvanised earth lead wire 4mm dia (upto 7.5mt), by means of bolts, nuts check nuts and washers of galvanised iron or steel and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC (1:2:4) type C-2 including excavation and earth work , disposal of surplus soil to a distance not exc 50 mtr all as specified and shown on electrical plate No 3 of SSR Part-I (1991) all as specified and RCC pit cover shall be precast of RCC 1:2:4 type B-1 80 mm thick reinforced with XPM weighting not less than 4kg/sqm in lieu of cast iron cover.
Dismantaling existing fan from site and refixing of ceiling fan / exhaust fan suitable for 1200 / 1400 mm of sweep of approved size suitable for hanging as directed by Engr-in-Charge
the bhimani group of companies
SLB Enterprises
M/S. ADARSH ENTERPRISES
OM INFRA
pk janardhanan
OM SAI ASSOCIATES
M/S KVG CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .