Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹15.2 L+₹2.4 L (18.4%)Rejected-Finance | L2 | Rejected-Finance Other than lowest |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
24 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
REPAIR / MAINT OF HT LINES, HT CABLES, HT POLES, TRANSFORMERS AND OTHER CONNECTED WORKS AT VARIOUS LOCATIONS UNDER BHALRA MIL STN UNDER GE (I) 873 EWS.
2022_MES_541423_1
NIT-23 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹500
GE (I) 873 EWS
₹36,000
Yes
22 Sept 2022
27 Jul 2022
27 Aug 2022
27 Jul 2022
24 Aug 2022
10 Aug 2022
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cutting of existing road / hard standing for laying of GI protection pipe for cables, depth of trench not exceeding 0.75mtr, width of trench not exceeding 1.0mtr and making good by returning filling in (by well ramming and watering of soil in layers not exceeding 25cms), provision of 150mm thick sub base, 150mm thick WBM and thereafter 150mm thick PCC 1:2:4 type B-1 (using 20mm graded aggregate) including removal of surplus spoil to a distance not exceeding 50mtrs complete all as specified and as directed.
Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete for poles, complete all as specified and directed.
Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete for stays, complete all as specified and directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable Pole all as specified and as directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer including dismantling / taking down old unserviceable structural steel all as specified and as directed.
Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm), Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm) as in replacement complete all as specified and as directed.
Pin type porcelain, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Disc type insulator, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised 145 mm height 255 mm dia for 11000 Volts grade including taking up of old unserviceable insulator complete all as specified and directed.
Shackle type insulator porcelain vitreous white, brown or green including galvanised M.S. straps 31 x 5mm size, 150mm height, 150mm dia including galvanised mild steel straps, nut, bolts washers complete for 11000 volts grade insulator complete including taking up of old unserviceable Shackle type complete all as specified and directed.
Pin type insulator 70KN, porcelain, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut for 33000 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Disc type insulator 70KN, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle for 33000 volt, including taking up of old unserviceable insulator complete all as specified and directed.
Shackle type insulator 70KN, porcelain vitreous white, brown or green including galvanised M.S. straps , nut, bolts washers complete for 33000 volts grade insulator complete including taking up of old unserviceable Shackle type complete all as specified and directed.
Stay Assembly using stay rod of 16 dia complete accessories as shown in Electrical Plate No 1 of SSR 2009 Part-I such as loop type insulator, porcelain, vitreous white/ brown or green, large size with overall dimensions 90 x 140mm clearance of hole 16mm, stay wire of size 7/4mm etc., complete all as specified and directed. Note: Excavation and concrete shall be measured and paid separately.
Switch Air break, gang operated (GOD) with 09 No insulators in replacement, outdoor type, Three Pole mechanically operated, suitable for vertical installation, Single break, provided with locking arrangements consisting of MS channel, HT Post type insulator copper alloy, high Pressure, Assembly operating rod 25 mm dia GI pipe medium grade for operating from 1.2 metre above Ground Level with locking arrangement complete confirming to IS-1318 of 1972 rated voltage 11 KV and for current rating 200 Amps complete all as specified and directed.
Switch Air break, gang operated (GOD) with 09 Nos insulators in replacement, outdoor type, Three Pole mechanically operated, suitable for vertical installation, Single break, provided with locking arrangements consisting of MS channel, HT Post type insulator copper alloy, high Pressure, Assembly operating rod 25 mm dia GI pipe medium grade for operating from 1.2 metre above Ground Level with locking arrangement complete confirming to IS-1318 of 1972 rated voltage 11 KV and for current rating 400 Amps complete all as specified and directed.
Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed. Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. 2. The cutting / trimming of tree branches shall be done to at least 2.00 metre radius of OH line. 3. The unit of measurement is 'SPAN' i.e. distance covered between two poles.
Painting of steel tubular pole 11/12m any type with cross arms with one coat of aluminium paint after preparation of surfaces of pole / cross arms by scrapping of old paint, cleaning of all rusted surface and painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface of pole and cross arms structure over one coat of primer and marking of MES No complete all as specified and as directed.
Painting of steel structure at main receiving station at Bhalra and Dandi, preparation of old steel surfaces of any description exc 10cm in width or girth not otherwise described and applying two coats of aluminium paint, complete all as specified and as directed by Engr-in-charge. Note: Tenderers are requested to visit the site before quoting his rates to access the quantum of work to be painted. No claim whatsoever on this account shall be entertained at later stage.
Cradles, hexagonal/rectangular, fabricated with galvanized steel wire 3.15mm or 4mm dia including taking down old, complete all as specified.
Danger notice plate of size 25cm x 20cm x 1.5mm thick mild steel sheet, vitreous enamelled, white with letters, figures and conventional Skull & Bones in signal red colour and fixed with MS clamps, bolts and nuts of appropriate size, all as specified and as directed.
MCCB 400 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) in replacement complete all as specified and as directed.
MCCB 350 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) in replacement complete all as specified and as directed.
MCCB 250 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) in replacement complete all as specified and as directed.
MCCB 200 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) in replacement complete all as specified and as directed.
MCCB 160 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) in replacement complete all as specified and as directed.
MCCB 160 Amps, breaking capacity 16 KA, TP, 415V (adjustable thermal and magnetic release) in replacement complete all as specified and as directed.
MCCB 125 Amps, breaking capacity 16 KA, TP, 415V (adjustable thermal and magnetic release) in replacement complete all as specified and as directed.
MCCB 100 Amps, breaking capacity 16 KA, TP, 415V (adjustable thermal and magnetic release) in replacement complete all as specified and as directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with aluminium conductor suitable for rated voltage of 11000 Volt grade earthed system, 3 Core x 95 Sqmm and manufactured by triple extrusion using single (common) cross-head extrusion technique and dry cure inert gas cured cross linking process and conforming to IS and laid in trenches / ducts / pipe or on poles including taking down old unservicable cable complete all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with aluminium conductor suitable for rated voltage of 11000 Volt grade earthed system, 3 Core x 120 Sqmm and manufactured by triple extrusion using single (common) cross-head extrusion technique and dry cure inert gas cured cross linking process and conforming to IS and laid in trenches / ducts / pipe or on poles including taking down old unservicable cable complete all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with aluminium conductor suitable for rated voltage of 11000 Volt grade earthed system, 3 Core x 150 Sqmm and manufactured by triple extrusion using single (common) cross-head extrusion technique and dry cure inert gas cured cross linking process and conforming to IS and laid in trenches / ducts / pipe or on poles including taking down old unservicable cable complete all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with aluminium conductor suitable for rated voltage of 11000 Volt grade earthed system, 3 Core x 185 Sqmm and manufactured by triple extrusion using single (common) cross-head extrusion technique and dry cure inert gas cured cross linking process and conforming to IS and laid in trenches / ducts / pipe or on poles including taking down old unservicable cable complete all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with aluminium conductor suitable for rated voltage of 11000 Volt grade earthed system, 3 Core x 240 Sqmm and manufactured by triple extrusion using single (common) cross-head extrusion technique and dry cure inert gas cured cross linking process and conforming to IS and laid in trenches / ducts / pipe or on poles including taking down old unservicable cable complete all as specified and directed.
Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 25 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 35 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 50 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 70 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 95 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 120 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 150 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Aluminium cable lugs (connectors) for fixing / tightening of electric cable 185 Sqmm alongwith nuts and bolts for tightening complete all as specified and as directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed., all as specified and as directed.
Material and labour for disconnecting LT / HT electrical connection removing the defective indoor / outdoor transformer of capacity 63 KVA to 315 KVA Three Phase, Four Wire, 50Hz vector group Dyn 11 transformer loading and transporting to authorised workshop from site and vice-versa including disconnecting and rewinding with paper insulated copper winding wire / strip as per original data on HV (delta connection) and LV (Star Connection) 7 tapping brought on HV side for tap charger to change + 2.5%, 5%, 7.5% by means of manually operated Off-Load tap changing gear complete rewinding of HV on three limbs providing insulation material like spares, wooden blocks, cotton tape etc. and re-conditioning three limbs complete opening, replacement of cock sheet packing, vent diaphragm replacement of LT terminal plate, breather, filling of new transformer oil for top up with existing oil after proper filtration upto level of 50 KV dielectric strength and testing of transformer at factory and site after connecting all electrical connection in full load all as directed.
Notes :- 1. Spares required will be measured and paid separately under appropriate item. 2. The Quoted Rate shall be deemed to include transportation, electrical connections, Testing & Commissioning. 3. Necessary test certificate from authorised workshop after repair shall be submitted by the contractor to the Engr-in-Charge.
Supply only following Items / Spares required for transformers :-
(a) HT coil/ LT coil of suitable gauge of paper insulated copper winding wire for any capacity of transformer
(b) LT Bush with rod of brass complete cork washer with nuts, bolts and washers of brass of requisite size suitale for 63 to 315 KVA
(c) HT Bush with rod of brass complete cork washer with nuts, bolts and washers of brass of requisite size suitale for 63 to 315 KVA
(d) Gasket for Transformer
(e) LT terminal plate for outgoing connections.
(f) Breather for transformer of capacity 63 KVA to 315 KVA
Supply, filling and top up with new Transformer Oil of dielectric strength more than 50 KV at 2.5mm gap confirming to IS : 335-1993 complete all as specified and as directed. Make : APAR Oils / Savita
Spray Painting of complete Transformer with one coat of weather proof grey synthetic enamel paint after cleaning / removing dust, rust or carbon etc. including writing MES No / SM No complete all as specified and as directed.
Synthetic Insulation Mat in replacement, chequered type up to 11 KV rating as per ISI specification of size 2.0m x 1.0m x 25mm thick suitable for LT Panels, Transformers or DG Sets, complete all as directed by Engr-in-Charge.
Rectangular LED flood light 100 watt with innovative thermal management and equipped with IP66 protection complete including taking down old u/s light, complete all as directed. Make: Crompton Cat Part No. LFLN-100-CDL/60
Disconnecting electric supply from both ends of defective Voltage Stabilizer of capacity 320 KVA after disconnecting electric supply from both ends and transporting the same from Jai Ghati Pump house to Workshop at Jammu, opening top cover, taking out transformer oil, checking for faults and replacing the defective parts, checking / testing the stabilizer, refilling and topping up the transformer oil and transporting back to Jai Ghati Pump house and refixing in original position, making connections complete all as specified and directed by Engineer-in-Charge.
Disconnecting electric supply from both ends of defective Voltage Stabilizer of capacity 100 KVA after disconnecting electric supply from both ends and transporting the same from BTC II and BN II Pump house to Workshop at Jammu, opening top cover, taking out transformer oil, checking for faults and replacing the defective parts, checking / testing the stabilizer, refilling and topping up the transformer oil and transporting back to BTC II and BN II Pump house and refixing in original position, making connections complete all as specified and directed by Engineer-in-Charge.
Notes :- 1. Spares required will be measured and paid separately under appropriate item. 2. The Quoted Rate shall be deemed to include transportation, electrical connections, Testing & Commissioning.
Supply only following Items / Spares required for Stabilizers :-
(a) Reversible motor low speed instant Start / Stop High Torque having speed 960 RPM and of capacity 0.08HP.
(b) Servo Circuit Card.
(c) RC Network.
(d) Dimmer for 320 / 100 KVA Voltage Stabilizer.
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 32 x 6 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specified and as directed.
SWASTIK TRADERS
Bidder Name
SWASTIK TRADERS
SHARMA TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .