Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC H O PRABHAT KUMAR SINHA RAGHUNATH TOLA ANISABAD PATNA 800002 | PATNA | PATNA | BIHAR | 800002 | ₹11.5 L Quoted ₹11.8 L | L1 | Accepted-AOC QUOTED RATES ARE REASONABLE AND ACCEPTED |
| 2 | L2₹12.5 L+₹64,747 (5.47%)Rejected-Finance | ₹12.5 L+₹64,747 (5.47%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹14.4 L+₹2.6 L (21.6%)Rejected-Finance RANGIYA DIST KAMRUP ASSAM 781365 | BAKSA | ASSAM | 781365 | ₹14.4 L+₹2.6 L (21.6%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | MUKTI ENTERPRISES L2 | M/S NARAYAN ENTERPRISE L3 | SHIV SHAKTI TRADERS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n. exc 1.5 m wide for foundations, laying cables/ pipes etc. not exceeding 1.5 m deep and getting out in SOFT/LOOSE soil complete, all as specified. | 251.1 | Cubic Metre | 220 ₹55,242 | 160 ₹40,176 Lowest | 270 ₹67,797 |
| 2.00 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified. | 159.6 | Cubic Metre | 120 ₹19,152 | 110 ₹17,556 | 72 ₹11,491.2 Lowest |
| 3.00 | Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified. | 91.5 | Cubic Metre | 300 ₹27,450 | 165 ₹15,097.5 | 90 ₹8,235 Lowest |
| 4.00 | Cutting the existing road straight by manual, depth and width not less than 1 metre below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 using 20mm graded aggregate stone complete all as specified. | 18 | Running Metre | 600 ₹10,800 | 280 ₹5,040 Lowest | 495 ₹8,910 |
| 4.10NOTES APPLICABLE TO SERIAL ITEM 1 TO 4: (a) Excavation work shall be carried out manually only. (b) LT/HT cable, /telephone lines, if any, get damaged during excavation & earthwork, demolition of PCC shall be repaired by the contractor immediately as per existing specifications to the entire satisfaction of Engineer-in-Charge. | ||||||
| 5.00 | Brick protection with pulverized fuel ash lime bricks laid flat across the route of underground cable all as specified. | 8.09 | Per 1000 Nos | 6,000 ₹48,540 Lowest | 11,000 ₹88,990 | 8,730 ₹70,625.7 |
| 6.00 | Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified.
NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment. | 75.33 | Cubic Metre | 800 ₹60,264 | 580 ₹43,691.4 Lowest | 1,170 ₹88,136.1 |
| 7.00GI pipe light grade with all fittings fixed as termination postal ,fixed to poles/ walls/ under floors/ under road etc complete all as specified of following size: - | ||||||
| 7.01 | 40 mm bore | 12 | Running Metre | 600 ₹7,200 | 390 ₹4,680 Lowest | 405 ₹4,860 |
| 7.02 | 50 mm bore | 6 | Running Metre | 700 ₹4,200 | 480 ₹2,880 | 450 ₹2,700 Lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
11 Nov 2025, 6:00 pmClosed
GARRISON ENGINEER AIR FORCE BIHTA
Military Engineer Services AF stn Bihta 801103
REPAIR / MAINT OF LT UG CABLE, LT PANELS, MCCBs, SOLAR LIGHTS AND CONNECTED AT AF STN DARBHANGA UNDER GE AF BIHTA
2025_MES_736495_1
GE/AF/BHT-44/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DARBHANGA UNDER GE AF BIHTA
Ref NIT and Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE AF BIHTA
₹30,000
Yes
16 Jan 2026
23 Oct 2025
12 Nov 2025
23 Oct 2025
11 Nov 2025
6 Nov 2025
23 Oct 2025 - 5 Nov 2025
Amount
Excavation in trenches n. exc 1.5 m wide for foundations, laying cables/ pipes etc. not exceeding 1.5 m deep and getting out in SOFT/LOOSE soil complete, all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified.
Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified.
Cutting the existing road straight by manual, depth and width not less than 1 metre below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 using 20mm graded aggregate stone complete all as specified.
NOTES APPLICABLE TO SERIAL ITEM 1 TO 4: (a) Excavation work shall be carried out manually only. (b) LT/HT cable, /telephone lines, if any, get damaged during excavation & earthwork, demolition of PCC shall be repaired by the contractor immediately as per existing specifications to the entire satisfaction of Engineer-in-Charge.
Brick protection with pulverized fuel ash lime bricks laid flat across the route of underground cable all as specified.
Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified. NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment.
GI pipe light grade with all fittings fixed as termination postal ,fixed to poles/ walls/ under floors/ under road etc complete all as specified of following size: -
40 mm bore
50 mm bore
Supply, laying, jointing & testing of LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing including takind down existing cable complete all as specified of sectional area: -
6 Sq.mm,2 core
10 Sq.mm,2 core
16 Sq.mm,4core
35 Sq.mm,3.5 core
50 Sq.mm,3.5 core
70 Sq.mm,3.5 core
95 Sq.mm,3.5 core
PVC insulated unsheathed / sheathed cable with standard aluminium conductor 1100 Volts grade flat twin core service cable of size 2.5 sqmm confirming to IS:694/1990 with latest amendement ISI including disconnecting / taking out existing unsv/damaged old service cable completed all as specified and directed.
MCCB with adjustable thermal magnetic release, ICS=ICU=100%, 4 Pole, 415 volts, AC, with over load and short circuit protection, 400 Amp, rupturing capacity 36 kA. and rupturing capacity , IN REPLACEMENT complete all as specified. Make : L&K/ Legrand/ABB
Cutting and trimming trees branch any girth and any size touching to overhead lines and cleaning the distance 2.0 mtrs length both sids of OH line with a span of 50 mtrs (approx) each disposing the same clearing the site upto the satisfaction level and all as directed by Engr-in-charge. Note : All tools, plants and machinary equipment and manning required are quoted in the rates.
Hot press moulded SMC junction box / Terminal Box insulated and made out of environment friendly, recyclable, UV resistant , halogen & silicon free, polycarbonate with glass fiber reinforced of intenal size 300 x 200 x 1055 mm having protection IP-66/67 including MCB single pole 6-32 amp and all fixing acessories as required IN REPLACEMENT complete. MAKE: Hensel / RITTAL or equivalent make mentioned in Appendix 'B'.
All in 1 Solar LED street light 27.5 watt,with high lumen output minimum 140 lumen/watt compl with solar plate of LifiePO4 battery outdoor type , IP 66 protection, IN REPLACEMENT, and making connections, complete.
Garden bollard light 12Watt of height 1.5/2.0 feet for outdoor garden waterproof (cool white ) , IP 65/66 protection alongwith unbreakable garden lamps for Outdoor, Rustproof with protection , with impact and corrosion resistant having base plate for connection to PCC 1:2:4 foundation complete with drive and lamps complete all as specfied. Note : The cost of PCC foundation , Coping , etc shall be included in the Quoted rate.
LED Driver for street/ flood light 100 watt operates efficiently with a wide input rangr of 100-300V AC and frequency of 50-60 Hz ensuring adapatability to various electrical environments with over and under Voltage protection (OVP) , surge protection, IN REPLACEMENT ,complete all as specified and directed.
LT panel board shall be factory (CPRI approved) fabricated, suitable for 415 volt, 3 phase, 4 wire 50 Hz AC supply, cubical type, dust & vermin proof (Kiosk type), made out of CRCA sheet 3.15 mm thick except inner sheath. Frame and legs shall be made of 50 x 50 x 5 mm size angle. Vertical height of legs shall be not less than 45 cm from top of PCC floor finish. Legs shall be grouted in PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate). The dimensions/size of the LT Panel shall be as on required basis for incorporating the electrical accessories/ components as specified below and these particular specifications. The front and back side of the LT Panel shall be provided with hinged double doors with locking arrangement. The locks shall be built in flush type of superior quality as directed by Engineer in Charge. The hinged shall be of such construction that the door can swung open by not less than 150 degree. The fixing of the doors shall be such that the doors should automatically come to closed position if not kept open with effort. The panel shall be designed in such a way so as to have independent compartments/cabins for housing MCCB’s, cable gallery, bus bar chamber, switch and other accessories. Bus bar, MCCB, cable incoming, cable outgoing, time switch chambers will be manufactured of not less from 2mm thick MS Sheet. Panel shall be painted with anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) all s specified in relevant IS. including installation, commissioning & testing, comprising the following components/acessories:- INCOMMING:- a) Copper stri busbar of current carrying 800 Amps wrapped with PVC sleeves with maintained the colour code and provision of making holes with copper nuts, bolts & washers for cable connections including hydrographic insulators with nuts & bolts at both ends = 4 Nos.
Notes: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline.
MUKTI ENTERPRISES (BID ID -3471579)
M/S NARAYAN ENTERPRISE (BID ID -3476683)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
TENDER442526.pdf
Tender Documents • 0.96 MB
BOQ_824654.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .