| 1 | L1₹34.3 LAccepted-AOC AT PO DERA COLLIERY TALCHER DIST ANGUL ODISHA PIN 759103 | ANUGUL | ODISHA | 759103 | L1 | Accepted-AOC AOC Awarded | |
| 2 | L2₹34.8 L+₹50,420.70 (1.47%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹35.4 L+₹1.1 L (3.19%)Rejected-Finance A 1 DEEPMALA BUNGLOW CADILLA ROAD GODASAR AHMEDABAD CITY | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹35.5 L+₹1.2 L (3.41%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹36.0 L+₹1.6 L (4.69%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹83,000
Closing Date
15 Feb 2023, 6:55 pmClosed
GE WEST ALLAHABAD
GE WEST ALLAHABAD NEW CANTT ALLAHABAD
PROVN OF SUB AREA CANTEEN BLDG AT NEW CANTT ALLAHABAD
2023_MES_573624_3
8612/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST ALLAHABAD
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE WEST ALLAHABAD
₹83,000
Yes
1 Mar 2023
9 Feb 2023
17 Feb 2023
9 Feb 2023
15 Feb 2023
10 Feb 2023
Amount
Excavation in trenches n. exc 1.5 m width and n. exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits , manholes , pier holes etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out soft/ loose soil complete all as specified and directed.
Returning filling in , including spreading , levelling , watering and well ramming in layers n exc 25 cm in soft / loose soil complete all as specified and directed.
Spreading and levelling of excavated soil in layers n exc. 25 cm thick with well ramming including watering as required for filling under floor complete all as specified and directed.
M&L for PCC 1:4:8 type D-2, using 40mm graded stone aggregate, as in foundation filing , sub base of floor or mass concreate complete all as specified and directed.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M&L for treating the top surface of filled earth as in floor at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
M&L for bitumen blown any grade, applied hot, two coats, to concrete surfaces at the rate of 1.5kg. per sq. m per coat complete all as specified and directed.
M&L for polythene film, black, 50 micron laid in floors complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-0 damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in lintel band at any height complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in slabs supported on walls, roof beams etc and the like, complete all as specified and directed.
M&L for brickwork with fly ash bricks (old size), straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finish surface complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surface complete all as specified and directed.
M&L for formwork to sides and soffit of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc rough finished complete all as specified and as directed.
M&L for mild steel TMT bars of 10mm dia and over in reinforcement cut to length bent to shape required including cranking bending and binding with mild steel annealed wire not less than 0.90 mm dia or securing with clips and as straight in groves complete all as specified and directed.
M&L for mild steel TMT bars 5mm dia and over up to and including 10mm dia in stirrups, spaces, nibs and binders complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick or concrete surface, finished even and fair without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surface, finished even and fair without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound (ISI marked) complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper on 3 mm thick wall putty complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of cement base paint over one coat of primer over a coat of 1mm thick wall putty complete all as specified and directed.
M&L for hardcore of gauge n exc. 63 mm, of broken stone deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mt centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and directed.
M&L for providing and fixing factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories . Net Opening will be measured lor payment purpose.) (A) Area not exceeding 2.00 sqm each.
M&L for granite 20mm thick (of any type) work (table rubbed and polished) including the screed bed in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. including with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M&L rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified
S&F including fabrication of framed work such as in grills, grating, hold fast of door and window chowkat etc., with ends of bars shouldered and or riveted or forget into spikes, frames guard bars, barred iron doors, and similar work conforming to complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded aggregate as in hold fast block including necessary form work etc complete all as specified and directed.
M&L for vitrified light shade floor tiles (scratch free) 10mm thick (square/ rectangular) area of each tile not exc 0.36 sqm,in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
S&F for powder coated Anodised aluminium frame (min thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F for powder coated anodised (min thickness of powder coating 50 micron) aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and directed.
S&F for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F 5mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F 0.50 thick (including coated thickness) pre-colour, pre-profiled corrugated (Galvalume/Zinkalume) sheets of required colour and design having tensile strength of 550 Mpa as in roof, wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and directed.
S&F 0.50 thick (including coated thickness) pre-colour, plain type sheet (Galvalume/Zinkalume) any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, used as in ridge fixed with self tapping screws all as per manufacturer / profile maker instruction complete all as specified and directed.
S&F for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of grade Fe-290 (Gde E- 165) complete all as specified and directed.
S&F for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment of grade Fe-290 (Gde E- 165) complete all as specified and directed.
S&F for mild steel screw bolts (machine made) dia 20mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,but length of bolt exc 22.5cm and n exc 30cm long complete all as specified and directed.
M&L for preparation of new surface of steel surfaces painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F powder coated GI ceiling suspension system false ceiling grid of 600x 600mm size and 0.30 mm thick (MS galvanized (PPP CGS)) with main tee, cross tee and wall angle grid hanging with 4mm dia Gl wire and roof fasteners or butterfly clips etc complete all as specified and directed.
S&F 4 mm thick non asbestos fiber cement building board of 600x600 mm in size (HPSC E-classic) decorative finish fixed to aluminium /CGI frame work with hold down clips in false ceiling complete all as specified and as directed.
Grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable material and removing of unserviceable material to a distance n.exc 50 m and clearing site girth of tree exc 250 cm & n.exc 300 cm complete all as directed.
Grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable material and removing of unserviceable material to a distance n.exc 50 m and clearing site girth of tree exc 30 cm & n.exc 100 cm complete all as directed.
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and directed.
Rolling and consolidating formation surfaces by Power Roller 8 to 12 Tonne in cutting complete all as specified and directed.
M&L for 150mm soling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and directed.
Rolling on soling of broken boulders or quarried stone, not exc 15cm thickness by Power Roller 8 to 12 tonne complete all as specified and directed.
M&L 150mm in two layers (75 mm+75 mm) thick (compacted thickness) WBM, with coarse aggregates of grading 2 (63 to 40mm size) or of grading 3 (50 to 20mm size), spread, rolled and consolidated to gradient and camber required complete all as specified and directed.
Rolling on water bound macadam (except laterite, kankar and broken brick aggregates) not exc 15cm thickness by Power Roller 8 to 12 tonne complete all as specified and directed.
M&L for preparing surfaces of water bound macadam by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc, complete all as specified and directed.
M&L for applying evenly a priming /tack coat with bituminous primer by paving bitumen at 10 kg per 10 sq metre complete all as specified and directed.
M&L for Bituminous premix asphaltic dense concrete 40mm consolidated thickness with 5.5% binder content by weight of total mix, rolled and compacted to required camber and gradient complete all as specified and directed.
M&L for continuous brick edging with width, equal to the width of the brick laid dry on end vertically with old size Brick complete all as specified and directed.
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken modular type pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for following items complete all as specified and directed. Note:- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
All as per item above but for one light / fan point controlled by one, one way switch
All as per item above but for one 3 pin 5 amps socket out let point on same board
All as per item above but for one 3 pin 5 amps socket out let point on independent board
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken modular type pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note :(i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet shall be measured and paid separately.
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 4.0 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken modular type pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note :(i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet shall be measured and paid separately.
S&F modular switch single pole 1 way, 1 module, 5/6 Amp complete all as specified and directed.
S&F modular switch single pole 1 way, 2 module, 16 Amp complete all as specified and directed.
S&F modular socket out let multipurpose 6A -2/3 pin, SP 1 way 2 module complete all as specified and directed.
S&F modular socket out let multipurpose 6A/16A-2/3 pin, SP 1 way 2 module complete all as specified and directed.
S&F modular fan regulator 240 V electronic type 2 module complete all as specified and directed.
S&F ceiling rose surface bakelite, 65X50 mm three terminals complete all as specified and directed
S&F modular white cover plate with frame 3 module complete all as specified and directed.
S&F modular white cover plate with frame 6 module complete all as specified and directed.
S&F modular white cover plate with frame 8 module complete all as specified and directed.
S&F sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
S&F sheet metal enclosure for MCB's 240 volt 8 way single pole and neutral with 200 amps rated bus bar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SPN, 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
M&L for concealed sub main wiring with 2 Nos single core PVC insulated unsheathed FRLS 6.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable for earth continuity, drawn in & including non metallic rigid PVC conduit medium grade 20mm bore including accessories concealed in wall including cutting chases in wall and making good disturbed surface to match of wall/ceiling complete all as specified and directed. (length of 2 No 6.0 sqmm conductor cable, 1 No 4.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for concealed sub main wiring with 2 Nos single core PVC insulated unsheathed FRLS 10.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 6.0 sqmm stranded copper conductor cable for earth continuity, drawn in & including non metallic rigid PVC conduit medium grade 20mm bore including accessories concealed in wall including cutting chases in wall and making good disturbed surface to match of wall/ceiling complete all as specified and directed. (length of 2 No 10.0 sqmm conductor cable, 1 No 6.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
S&F 18/20 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No. ENDURA LINE ARNE OBS18/20WLED865SPCWH or equivalent in Bajaj / CG/ Phillips/ Wipro.
S&F ceiling light with environmental friendly, new generation, aesthetically designed, ultra modern recessed mounted LED light luminaries of size 595 mm x 595 mm an independent Isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage- 36/40/42 Watt, Lumen out put- 4000-4300 Lm, THD < 10%, PF > 0.9, having short circuit and surge protection suitable for Armstrong/ Grid ceiling with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make: Cat pt No: PLUTONEO2X2PLR42WLED857S of make Havells 'or' RC380B LED36S-4000 G4 L60 W60 PSD OD WH OC of make Philips 'or' LCTTLRP-36-FO-CDL of make Crompton
M&L for earthing complete with galvanized steel earth plate 60cmx60cmx6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to earth lead GI 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade, including protection pipe GI medium grade 15mm bore for earthing lead, wire mesh, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1, precast RCC cover using XPM reinforcement weighing not less 4kg/sqm in lieu of CI cover and frame all as shown in electric plate of SSR part-I (2009), including testing on completion all as directed.
Supply, installation, testing and commissioning Main LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC,50 HZ, indoor type, cubicle , floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection fabricated out of 2mm thick CRCA sheet powder coated painting , CPRI approved, separate compartment for ACB/MCCB/metering equipment/cable gallay etc, Front and rear hinged door with locking arrangement, copper bus bar duly covered with heat shrinkable sleeves colour coadded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting the outgoing MCCBs/switch gears with main bus bar by using aluminium bus links or copper conductor cable of suitable rating and connecting with terminal blocks of appropriate rating terminated by cable lugs, thimbles etc, earthing terminals, affixing danger notice plate, control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement. Angle iron of size 50mmx50mmx6mm for mounting of LT panel 40cm above floor level complete including necessary PCC foundation all as specified and directed comprising of following:- (a) 600 A rated copper bus bar with colour coded heat shrinkable sleeve (b) MCCB 4 Pole, 400 A, 415V, 35 KA with microprocessor based release - 01 No. (In coming) (c) MCCB 3 Pole, 250 A, 415V, 35 KA - 01 No. (Out going) (d) MCB SP, 6A, 230 V, 10 KA - 02 Nos. (Out going) (for Sub stn lightening) (e) Ammeter, Digital type, with suitable CTs of suitable capacity - 01 set (f) Voltmeter, Digital type of suitable capacity- 01 No. (f) R-Y-B phase indicating lamp- 01 set (g) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled.
Supply, laying and testing 95 Sqmm, 3.5 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for cable trench complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments.
S&F 50mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.
Technological Associates
A ONE ENGINEERING
M/S NAGENDRA AND BROS ENTERPRISES
JMD Enterprises
Channa Brothers and Co.
HARSH ASSOCIETES
DINESH ELECTRICALS
M/s Engineer
ARADHYA ENTERPRISES
M/S CHANDRIKA PRASAD AND SONS
Siddhi Constructionn
A R ENTERPRISES
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .