Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹17.0 L+₹3.7 L (27.5%)Rejected-AOC | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹18.7 L+₹5.4 L (40.6%)Rejected-AOC | L3 | Rejected-AOC L3 Bidder | |
| 4 | L4₹19.4 L+₹6.1 L (45.5%)Rejected-AOC 32 H I G AWAS VIKAS COLONY SECTOR 3 BODLA AGRA UP 282007 | AGRA | AGRA | UP | 282007 | L4 | Rejected-AOC L4 Bidder | |
| 5 | L5₹20.4 L+₹7.1 L (53.6%)Rejected-AOC D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-AOC L5 Bidder |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
9 Aug 2021, 6:00 pmClosed
GE I RND Delhi
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINTENANCE TO INTERNAL ELECTRIFICATION INCLUDING FITTING AND FIXTURE AND SUMMER APPLIANCES AND OTHER CONNECTED WORKS AT ADRDE AGRA UNDER GE I RND DELHI
2021_MES_458447_1
GE/RND-41/AGR/2021-2022
Open Tender
Civil Works
Item Rate
270 days
Agra
Class- D, cat b(i)
2 documents required · 2 mandatory
₹500
GE I RND Delhi
₹60,000
Yes
13 Sept 2021
9 Jul 2021
11 Aug 2021
9 Jul 2021
9 Aug 2021
28 Jul 2021
Amount
Taking down ceiling fan/exhaust/air circulating fan of any size or make by disconnecting electric connection and removing from site for rewinding,servicing, painting of fans and refixing in the same position after repair work complete all as specified & directed.
M&L for cleaning, washing, greasing, oiling and varnishing of ceiling fan of any size and make complete all as specified and as directed.
M&L for rewinding of ceiling fan with super enamelled copper winding wire of same gauge & size of ceiling fan 1400 mm sweep complete all as specified and directed.
All as per ser item No.3.00 above but for 1200 mm sweep.
All as per ser item No.3.00 above but for exhaust fan of size 300 mm sweep.
All as per ser item No.3.00 above but for aircirculating fan of size 450 mm sweep.
S&F in repair of defective ball bearing for ceilling fan of 1200 mm sweep as per existing size complete all as specified & directed
All as per ser item No. 7.00 above but for ceiling fan of size 1400 mm as per existing size
S&F in repair of defective capacitor of size 2.5 mfd for any type of fans suitable for 230 V including making connection complete all as specified and directed.
All as per ser item No 9.00 above but 4.0 mfd.
M&L for painting of ceiling fan any make or size upto 1400 mm sweep at site with one coat of superior quality synthetic enameled paint of approved make by spraying, filling cavities with filler after preparation of surface and wirting letter as per existing such as (MES AC12345) with black systhetic enameled paint 1" high on both sides of fans complete all as specified and directed.
S&F in repair PVC body ventilating Fan 250 mm sweep complete all as specified & directed. Note : Old fan shall be depositd to E/M store yard.
M&L for removing the desert cooler from the site and re-fixing after cleaning the desert cooler body from inside and outside using sand paper to make the smooth surface and painting one coat of synthetic enamelled paint over a coat of red oxide primer as per exiting colour outside and inside the cooler, including oiling and greasing of fan kit, water pump motor complete all as specified and as directed.
S&F new wooden wool pad, set of three Nos,covered by GI wire mesh suitable for desert cooler including taking out the old unserviceable exiting pad complete all as specified and as directed.
S&F in repair water pumping kit of desert cooler (ISI marked) single phase, 220 AC, 15 to 18 Watt suitable for desert cooler specified and as directed.
S&F in repair of copper wound desert cooler motor 220 Volts single phase as per exiting sample/ size and fixing in same position by providing new nut , bolts,washer,MS frame/side arms and rubber pads etc including testing complete all as specified & directed.
S&F in repair switch piano, flush type single pole,one way, 5 Amp 230 V AC ISI Marked to be mounted on desert cooler complete all as specified and as directed.
S&F in repair of 3 pin plug top 5 Amp 230 V AC for connection lead of desert cooler complete all as specified and directed.
S&F in repair of 3 pin plug top 15 Amp 230 V AC for connection lead of desert cooler complete all as specified and directed.
S&F in repair steel multi wing fan blade set, best quality as per exiting type and size suitable for desert cooler complete all as specified and as directed.
S&F in repair of desert cooler body size 30"x30"x35" made of PGI sheet 1 mm thick complete with both side panels,front panel,side arms,tank,frontgrill made of PGI sheet etc including fixing the existing fan kit & Pump motor received from old unserviceable desert cooler including all electrical connections,testing and commisioning complete all as specified and as directed .
Supply and fix in repair voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation betweeen 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ±2.5% and of capacity 3.0 KVA complete all as specified & directed
S&F in repair voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation betweeen 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ±2.5% and of capacity 4.0 KVA.
Taking down Window Type AC 1.5 TR Capacity to carry out General Servicing such as removing dust,cleaning all Accessories like Compressor, Cooling coil,etc replace-ment of thermal Clip of Compressor Terminal,Electrical Wiring,Cleaning of fan Blade,etc and return to MES yard and testing, complete all as specified and as directed.
Taking down defective Window type AC 2.0 TR capacity including transportation from MES store/site to workshop to carry out General Servicing such as removing dust,cleaning all Accessories like Compressor, Cooling coil,etc replace-ment of thermal Clip of Compressor Terminal,Electrical Wiring, Cleaning of fan Blade,etc and return back to MES yard and Testing, complete all as specified and as directed
Taking down defective Split type AC 1.5 TR capacity including transportation from MES store/site to workshop to carry out General Servicing such as removing dust,cleaning all Accessories like Compressor, Cooling coil,etc replace-ment of thermal Clip of Compressor Terminal,Electrical Wiring,Cleaning of fan Blade,etc and return back to MES yard and Testing, complete all as specified and as directed
Taking down defective Split Type AC 2.0 TR Capacity including transportation from MES store/site to workshop to carry out General Servicing such as removing dust, cleaning all Accessories like Compressor, Cooling coil,etc replace-ment of thermal Clip of Compressor Terminal,Electrical Wiring,Cleaning of fan Blade,etc and return to MES yard and testing, complete all as specified and as directed
M&L for taking down/up defective brunt compressor and sealed unit of Window type AC 1.5 TR capacity and providing new reciprocating Compressor of same capacity from Authorised Dealer of OEM including flushing of condensor and charging with required gas, re-connection of electric connections complete in all as specified and as directed.
All as per ser item No 28.00 here-in-before but AC 2.0 TR
M&L for taking down/up defective brunt compressor and sealed unit of Split type AC 1.5 TR capacity and providing new reciprocating Compressor of same capacity from Authorised Dealer of OEM including flushing of condensor and charging with required gas, re-connection of electric connections complete in all as specified and as directed.
All as per ser item No 30.00 above but AC 2.0 TR Capacity (Split Type).
S&F in repair fan motor of AC (Split Type) 1.5 TR capacity of approved Make and required size to suit exiting AC including removal of the unserviceable fan motor complete all as specified and as directed
All as per ser item No 32.00 here-in-before but AC 2.0 TR Capacity (Split Type).
S&F in repair PVC blower of AC Split Type 1.5 TR Capacity of approved Make and required Size to suit existing AC complete all as specified & directed.
S&F in repair PVC blower of AC Split Type 2.0 TR Capacity of approved Make and required Size to suit existing AC complete all as specified and as directed
S&F in repair Fan motor blades (PVC) AC (Window/split Type) 1.5 TR capacity complete all as specified and as directed
S&F in repair Air filter suitable of AC (Window Type) 1.5 TR/2.0 Capacity complete all as specified and as directed.
S&F in repair Air Filter suitable of AC (Split Type) 1.5 TR Capacity complete all as specified and as directed.
S&F in repair Air Filler suitable of AC (Split Type) 2.0 TR Capacity complete all as specified and as directed.
M&L for rewinding fan motor of AC 1.5/2.0 TR Capacity.(Window type) of any make with Super Enameled copper wire of appropriate gauge and Quantity including taking out burnt wiring complete all as specified and as directed
Ass as per item srl No 40.00 above buty split AC (out door unit)
S&F in repair capacitor running 36 mfd for AC (Window/Split Type) 1.5 TR/2.0 TR capacity complete all as specified and as directed.
S&F in repair capacitor running 50 mfd for AC (Window/Split Type) 1.5 TR/2.0 TR capacity complete all as specified and as directed.
S&F in repair copper tube ISI marked 10mm dia of existing length as approved for AC (Split Type) complete all as specified and as directed.
S&F in repair Front Plastic Grill of AC (Window type) 1.5 TR capacity of existing make complete all as specified and as directed.
S&F in repair Front Plastic Grill of AC (Window type) 2.0 TR capacity of existing make complete all as specified and as directed.
S&F in repair Starting relay of AC (Window Type) 1.5 TR/2.0 TR capacity complete all as specified and as directed.
S&F in repair Thermostat switch of AC (Window type) 1.5 TR capacity complete all as specified and as directed.
S&F in repair Thermostat sensor of AC (Split type) 1.5 TR capacity complete all as specified and as directed.
S&F in repair Thermostat sensor of AC (Split type) 2.0 TR capacity complete all as specified and as directed.
Supply and charging (top up) compressor of existing water cooler and AC any type and capacity charging with required quantity of appropriate Refrigerant Gas R 22 complete all as specified and as directed.
S&F in repair compressor of water cooler 40/80 Litre capacity of the same make and capacity, transportation from MES store yard/Site to workshop and back including refixing /reinstalling, connecting and testing the same from authorised dealer of the OEM including flushing of condenser Refrigerant Gas, complete all as specified and as directed
All as per ser item No. 52.00 above but for water cooler 120/150 Litre capacity.
S&F in repair stop valve for 15mm bore of pipe, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both end for iron pipe or unions etc.complete all as specified and as directed
Taking out old unserviceable push Tap and S&F new Push tap 15 mm, any colour high pressure of PTMT screwed for iron pipe and fixed, (Minimum weight 15mm-47gms suitable for water cooler complete all as specified and as directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed.
M&L for taking down and strip opening for the Geyser of 25 Ltrs capacity complete geyser of any make/ shape, inspecting the serviceability state of all parts and carry out complete descaling of all serviceable parts such as inner tank, outer cover, geyser assembly, thermostat, heating element, rubber gasket and rubber ring etc with cleaning rod, brush or cleaning solution (chemicals) or any other suitable method and reassemble the geyser and re-fixing in the same position complete all as specified and as directed . Note :- Replacement of any defective parts required for making the geyser serviceable shall be measured and paid separately under respective item here-in-after as supply only.
Supply only copper inner tank of 25 ltr capacity with any numbers of holes all as specified and directed
Supply only cover outer complete including top and bottom suitable for 25 Ltr capacity gyser of any make, shape and size as per existing but gauge of sheet not less than 22 SWG all as specified and directed
Supply only bottom base plate geyser assembly of copper 6/9 holes type suitable for 25 Ltr capacity geyser all as specified and directed
Supply only heating element 1500 watts capacity in round/ triangular shape bottom(Cup shape ) with rubber gasket complete all as specified and directed.
Supply and fix in repair thermostate suitable for adjust the temperature from 0 degree centigrade to 80 degree centigrade complete all as specified and directed
Supply and fix in repair neon indicator lamp of any shape / size/colour complete all as specified and directed
Supply only brass geyser assembly suitable for 25 Ltr capacity gyser including nuts, washers, check nuts and all connected items, complete all as specified and directed
Taking down carefully unserviceable copper/aluminium point wiring (light,fan and power socket etc.) complete including fittings such as switches , ceiling roses,pandent ,regulators, sockets (excluding light fitting)etc and making good of distrubed surface complete all as specified and as directed
M&L for point wiring with colour coding multistranded copper conductor cable, PVC insulated (FRLS) and unsheathed of size 1.5 sqmm with PVC casing and caping with fixing accessories, to be fixed on wooden gutties or plastic rawal plug , for one light/ fan/bell point controlled by one switch with pressed steel concealed terminal boxes covered with 3mm thick laminated sheet/modular plate including contineous earth wire of PVC insulated unsheathed multi stranded copper conductor cable of size 1.5 Sqmm for earth wire connected to common earth dolly, Including making good all disturbed surfaces to match the existing colour complete all as specified and directed
All as per ser item No 66.00 above but One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size.
All as per ser item No 66.00 above but One 3 pin socket outlet, 15 Amps, independent, with cables 4.00 sq. mm size.
S&F switch socket combination 2 in 1, 3 pin ,5 Amp flush type universal complete all as specified and directed
S&F switch socket combination 2 in 1, 3 pin 5 and 15 Amp flush type universal complete all as specified and directed
S&F switch piano flush type, 5 Amps, single pole one way complete all as specified and as directed.
S&F in repair Buzzer, Ding Dong AC. 230 volts,single pole complete all as specified and directed
S&F bell push , 5/6 Amps, single pole complete all as specified and directed
S&F stepped type electronic fan regulator 60/100 watt flush type on the existing laminated sheet etc as required complete all as specified and directed
S&F ceiling rose, polycarbonate , isolated body surface type bakelite 65 x 50 mm three terminal (ISI marked)complete all as specified and directed.
S&F in repair LED lamp 20 Watt, suitable for fix in lamp holder complete all as specified and directed.
S&F lamp holder (ISI marked), PVC/ Polycarbonate type and back plate suitable for batten fitting complete all as specified and directed.
S&F in repair 36/40 watt domestic use electronic ballast suitable for FTL lamp in ABS housing with lead in wires for easy connection complete all as specified and directed.
S&F in repair universal starter 230/240 Volts, suitable for FTL 36/40 watt , complete all as specified and directed.
S&F in repair T8/T12 FTL, 1X36 watt decorative strip type light fitting with domestic electronic ballast and engineering plastic end cap paltes including necessary connection to the ceiling rose complete all as specified and directed.
S&F in repair Tube rod T8 MAXOLINE 1X36 Watt, 6000K, suitable for T8/T/12 1X36 Watt light fitting complete all as specified and directed.
S&F in repair Fan Capacitor 2.5 MFD suitable for ceiling fan 1200 mm/ 1400 mm sweep and connecting with connecting clip of ceiling fan complete all as specified and directed.
S & F in repairs, crystal glass 20W LED tube with double side connection,with high efficiency complete all as specified and directed
S & F in repair basic all purpose surface and wall mounted 20 watt LED batten with polycarbonate housing & integrated electronic driver suitable for 20W LED tube complete all as specified and directed.
S&F in repair MCB DBs double door flush mounted 8 way SPN with 200 Amps rated copper bus bar 240 V.
S&F in repair MCB DBs double door flush mounted 4 way SPN with 200 Amps rated copper bus bar 240 V.
S&F in repair MCB, SPN 40 Amps, 240 V AC complete all as specified and as directed.
S&F in repair MCB SP 6 to 32 Amps, 240 V, 50 Hz,10 kA Suitable for lighting and other domestic loads complete all as specified and as directed.
S&F in repair trim LED round, aesthetically designed recessed mounted panel in a light weight plastic body light fitting 15 Watt 3000 K complete all as specified and directed.
S&F in repair Octane LED panel square fitting, slim, compact, aluminium die cast edge recess mounted square fixture with opal diffuser and separate electronic driver 24 Watt 3000 K.Complete all as specified and directed.
S&F in repair E-LITE LED 9 Watt, 6000K, decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly energy efficient ready to use .Complete all as specified and directed.
Note for ser item No. 1 to 91 :- 1. The contractor shall provide and deploy sufficient technicians with helpers(as directedd by GE / Engineer-in-charge). Contractor's site supevisor/site engineer shall report at 0900 hrs daily excluding Sunday & holiday to collect the complaints job card & complete the same complaint detailed by JE E/M/Engineer-in-charge with in 48 hrs. 2. The complaints shall be attended with in 48 hrs. If the complaints is/are not attended /not completed on same day (except repair/ replacement of major items like replacement of compressor, cooling coil, condensing coil and fan motor etc.) recovery will be done as follows:- (a) After 48 Hrs, Rs.250/- Per complaint per day. The decesion of GE on recovery against penalty shall be final and binding and No representation whatsoever shall be entertained. 3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at ADRDE area. 4. The contractor has to produce machine number job card duly signed by user duly satisfactory completion of job & JE E/M to Engineer-in-charge before claiming payment. In absence of this panelty @ Rs. 100/- for per complaint shall be recovered from thier dues.
GAURAV ASSOCIATES
LUCKY SALES CORPORATION
m/s shanti consruction co
Shiva Enterprises
PD GUPTA AND COMPANY
SOMA BUILDERS
M/S OM Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .