| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC N S T COLONY CIRCULAR ROAD HOUSE NO 04 DMC DIMAPUR 797 112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹11.1 L+₹1.1 L (10.5%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹11.4 L+₹1.3 L (12.5%)Rejected-Finance | L3 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹19,200
Closing Date
5 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Zakhama
AGE (I) Zakhama C/o 792 FPO PIN-900792 C/O 99 APO
SPECIAL REPAIRS TO BLDG NO T- 151 (OR LIVING) AND PROVN OF TILING IN BLDG NO T- 431 (MAIN OFFICE COMPLEX) AT ZAKHAMA MILITARY STATION
2020_MES_383805_1
8894 20 21
Open Tender
Civil Works
Item Rate
180 days
ZAKHAMA
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
AGE I Zakhama
₹19,200
Yes
22 Dec 2020
6 Oct 2020
7 Nov 2020
6 Oct 2020
5 Nov 2020
21 Oct 2020
60 days
Amount
Demolition of cement concrete in ground floor / paving not exceeding 15Cm thick below or above GL unreinforced.
Dismantling timber scantling 40 Sqcm and over in section, unframed work in any position
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including similar pattern roof covering.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets.
Taking down shutters of any description exc 1 sq.m and n exc 2 sq.m each
Taking down shutters of any description notexceeding 1 Sqm each.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 mixed with WPC @ 3 % by the weight of cement used and finishing even and smooth without using extra cement.
M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 6 and finishing even and smooth without using extra cement.
Supply only water proofing compound
M&L 25mm thk PCC 1:2:4 type B-0 using12.5mm graded agg as in flooring for level course 25mm thick.
M&L for 15mm thick screed bed or bedding layer of cement mortar 1:4 for laying floor finishes
M&L for joint free Non skid ceramic tiles 7 to 8 mm thick (square/rectangular ) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles.
All as above hereinbefore but in skirting including necessary cutting of tiles and 10 mm thick plaster in 1:4 as in backing coat.
M&L for second class hardwood as in scantlings clean sawn timber framed and fixed.
M&L for 4mm thick plywood, grade BWR,type BB, fixed with nails to timber frame work
M&L Galvanized, corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with L-type of J-typer or cranked hook bolts and washers, in roofs, etc with grade of zinc coating 275 complete
All as per item above but except sheeting.
S&F 0.63mm thick plain galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zince coating 275 complete
S&F 0.63mm thick plain galvanised, mild steel sheeting, in stepped flashing (measured as the minimum rectangle from which the pieces can be cut) etc and fixed with nail complete.
All as per item No 20 above but except sheeting.
M&L for non asbestos fiber cement board 4mm thick fixed to GI frame work complete all as specified and as directed
M&L GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylone sleeves and screws at 450mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasterners with and including ceiling section ( not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete all as specified and directed.
M&L Hangers 6 mm dia G I (upto 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasterners 12.5 mm dia 40 mm long complete all as specified.
M&L two coats of oil emulsion distemper to new wood / ceiling surface including preparation complete all as specified and directed.
M&L 2nd class HW weathering boarding, wrought both sides and edges shot and chamfered ( on exposed edges) , thickness 20mm to 25mm and rebated on thick edge to give 20mm laps.
S&F mild wind tie bar for roof including securing nuts bolts and washers conforming to Fe.290 Gde- E-165.
S & F 30mm thich Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides
S &F 2nd class hardwood 35mm thick glazed and skeleton shutters open rebated and prepared to receive glass gauze etc divided into squares, with plain, chamfered or rounded mitred and framing plain, chamfered or rounded, fitted with cut and metered beads for securing glass etc size of members of shutters as specified in SSR Part I Sec 8 clause 8.24 (a)
All as above as in windows shutters 30mm thick divided into squares, with plain, chamfered or rounded , mitred or rebated sash bars with stiles and rails as specified in SSR part I section 8 clause 8.24 (b) .
Supply and fixing as in replacement mild steel galvanized iron wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 and fixed with tinned tacks or staples complete all as specified and as directed.
Hacking out old broken glass ( any thickness,size,quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads.
M&L 3mm sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm each pane.
M&L Butt hinges med weight cold rolled mild steel and fixed 100mm size.
M&L Butt hinges med weight cold rolled mild steel and fixed 75mm size
S&F Aluminium anodised barrel tower bolt of extruded section and fixed 150 mm long
S&F Aluminium anodised barrel tower bolt of extruded section and fixed 100 mm long
M&L extruded aluminium alloy handles, fabricated type, anodised 150mm size.
M&L extruded aluminium alloy handles, fabricated type, anodised 100mm size
M&L 300mm long Aluminium alloy, anodised, sliding door bolt with hasp staple (Bolt type) and fixing clips of sheet, cast or extruded section or cast aluminium alloy and fixed.
S&F 300mm mild steel, ordinary rat tail rod pattern springs including roller and roller plate in repairs complete.
M&L floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring fixed in floor 140mm size.
S&F 2nd class hardwood small fittings such as brackets of anay type, latch and hinge blocks, shaped door and window stops and the like, including all neacessary' labours ; articles nexc 200 cu.cm each.
M&L Prelaminated Particle Board 18/19 mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancig white lamination, fixed with nails for pelmet boxes in repairs.
Supply and fixing as in replacement 19/20mm dia mild steel chromium plated curtain rods with and including fixing socket complete all as specified and as directed.
M&L including preparation and treating one coat of synthetic enamel paint on old painted wood and wooden surface exceeding 10cm width or girth
M&L including preparation and treating two coats of synthetic enamel paint over a coat of pink primer to new wood and wooden surface exceeding 10cm width or girth
M&L for preparation of new painted surfaces of steel and iron work of any description over 10 cmwidth or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of redoxide and washing with mordant solution on new surfaces in any tint complete all as specified.
All as above hereinbefore but applying one coat on old surfaces
M&L for preparation of newly plastered wall surface with two coats of oil emulsion distemper over acoat of primer.
M&L including preparation and treating two coats of cement base paint over a coat of primer to newly plastered wall surface .
M & L for cement concrete 1:3:6 type C-2, 75 mm thick using 40mm graded stone aggregates as in sub base
M & L for cement concrete 1:3:6 type C-2, 75 mm thick using 40mm graded stone aggregates as in plinth protection finished fair and even with ou using extra cement
M&L for screed bed or bedding layer or mortar 15 mm thick for laying floor finishes in CM 1:6
M&L chequered cement concrete tile 25CM x 25CM x 19 to 20 mm thick with grey cement and no pigment set, jointed and pointed in neat cement slurry.
M& L for provinding cement concreter type C1(1:3:6) using 20mm stone aggregate as in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing
Extra for forming fair finished drain or channel 20 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc including brushing neat cement slurry with 3.0 kg of cement per sq. Metre
Taking down carefully point wiring copper/aluminum (light, fan, socket complete) including unserviceable battens or from existing casing capping/conceal conduit including earth continuity wire and fittings such as switches, socket, ceiling roses,lamp holder etc and making good disturbed surfaces of wall/ceiling etc complete all as directed by Engr-in-charge.
M&L for point wiring with single core PVC insulated unsheathed multistranded copper conductor FRLS cable of size 1.5 Sqmm nominal area 1100 volt grade drawn through and including PVC casing-capping/conduit of suitable size with all fittings and accessories including PVC board with cover of suitable size for housing/mounting the switches/socket etc including 1.5 Sqmm PVC insulated unsheathed single core copper conductor as earth continuty wire connected to common earth dolly for one light/exhaust fan point control by one switch.one way compleate all as specified and directed.
All as per item No 60 above but for 15 amp socket by using 2.5 sqmm copper cable with 2.5sqmm copper conductor as earth continuity.
All as per item No 60 above but for 3 pin, 5 Amp Socket on the same board.
All as per item No 60 above but for 3 pin,5 Amp Socket on independent board
S&F switch piano flush button single pole one way 5 Amp.
S&F switch socket combination 2 in 1, 3 pin 05 Amp flush type universal
S&F switch socket combination 5 Pin, 16 Amp flush type.
S&F LED bulk head luminaires 10 W 6000k Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head Back-lit LED luminaire comprising of high brightness LEDs. complete all as directed. Make-Havells Cat No.HEXAFT10WLED857SSYMBOPC or eqvt make.
S&F ceiling rose surface back light 65 x 25mm, two to three terminal.
M&L Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer in Charge.
S&F LED lamps 10W, LM 80 tested LED technology,Wide voltage range 150-300VAC complete as directed by Engr in Charge. Make -Wipro or eqvt make of philips, bajaj, Havells
Taking down old unserviceable light fitting of any type any rating complete all as directed by Engr-in-Charge.
S&F LED T/L 20 W, Fixture size (1150x25x40) mm (for 20 W), complete with batten and luminaries Make - Havells , Model No. LUMILINEPLUSBS20WLED865SPCSS or equivalent ad as per the technical spevifications given below . Note: LED used shall conform to IS- 16103: 2012 &IS-16101:2012 should be of SMD type only. ii. LED efficiency shall be greater than 100 lumens per Watt/ max latest efficacy available. iii. Colour rendering index (CRI: Greater than or equal to 70). iv. Min efficiency of driver: 85%. v. Power factor of complete fitting: Greater than 0.95. vi. Input Operating Voltage: 140 V to 277V AC. vii. In-built high and low voltage cut-offs: 140 V Low and 277 (high). viii. Short circuit, Over load protection. ix. Housing of luminaries: Pressure die-cast aluminum LM6/ADC 12/LM 24housing
Taking down old unserviceable DB/Main switchs incl MCBs wooden block of any size and type and removing all as directed by Engr-in-Charge.
S&F PVC rectangular block of size 250x200x50mm depth asll as directed.
S&F PVC rectangular block of size 100x100x50mm depth asll as directed.
S&F sheet metal enclosure for DB when MCB to be used 8 way 200 amp rated bus bar, SPN 240V, double door complete all as specified and directed..
S&F sheet metal enclosure for DB when MCB to be used 2 way, SPN 240V single door without bus bar complete all as specified and directed..
S&F Isoltor DP, 32 amps, 240 V complete all as directed.
S&F MCB Single pole and neutral 240 Volts, 6-32. Amps, 10 A,C-series,Make -havells, cat No.DHMGCSNF006-032 or same as equivalent.
S&F MCB Single pole 240 Volts, 6-32. Amps, 10 A,C-series,Make -havells, cat DHMGCSPF006-032 or same as equivalent.
Dismantling/taking down old burnt out u/s UG cable/sub main wiring of any size complete from locations where directed.
S&F 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor surved with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire, one twin core cable flat or rouind or 16 sq mm cable.
S&F submain wiring 2x6 sqmm alongwith earth wire 1x6 sqmm FRLS PVC insulated copper conductor, single core in surface/recesssed drawn in and including casing capping with fixtures.
Dismantling house service brackets, any type
S&F House service bracket (Hook type) compleate with 3.0 meter long GI pipe 40 mm dia Med grade, two Nos 90 degree bends, MS hooks and stay or guy.
M&L Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00mm dia by means of nuts, bolts, check nuts & washers made of galvanized iron or steel and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 30cmx30cmx10cm with one handle for lifting made out of 8mm dia MS bar, watering pipe 20mm bore galvanized iron pipe (medium grade) with MS funnel for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soil complete all other accessories as shown on electrical plate No 3 of MES Sch Pt-I including taking down the existing,all as specified and directed.
Rameshwar Prasad
KAILASH KUMAR LADHA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .