GEMC-511687714096638
Awarded to MEDI WAVES INC
₹2.1 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Syringe Infusion Pump | HK 400 | - | 10 NOS | ₹21,500 | 215,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.1 LQualified Make: NA
Model: HK 400 B 68 G T KARNAL ROAD INDUSTRIAL AREA DELHI DELHI DELHI 110033 | NORTH DELHI | DELHI | 110033 | Make: NA
Model: HK 400 | L1 | Qualified | |
| 2 | L2₹2.2 L+₹8,700 (4.05%)Qualified Make: Plenumtech
Model: PLENUMTECH, Model: ZION PLUS I P EXTENSION DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: Plenumtech
Model: PLENUMTECH, Model: ZION PLUS | L2 | Qualified | |
| 3 | Disqualified Make: KellyMed
Model: Kelley med KL602 A 38 1ST FLOOR NARAINA INDUSTRIAL AREA PHASE 1 NARAINA INDUSTRIAL AREA PHASE 1 SOUTH WEST DELHI DELHI 110028 | NEW DELHI | DELHI | 110028 | Make: KellyMed
Model: Kelley med KL602 | - | Disqualified | |
| 4 | Disqualified Make: Fresenius Kabi
Model: JYM JZB-1800C 203 HAIDAR MEDICAL 2ND FLOOR NEAR NEW MASJID FAIQ ENCLAVE BAREILLY UTTAR PRADESH 243006 | BAREILLY | UTTAR PRADESH | 243006 | Make: Fresenius Kabi
Model: JYM JZB-1800C | - | Disqualified | |
| 5 | Disqualified Make: NA
Model: MAESTROS MODEL MIP100 EL 66 EL 66 INDUSTRIAL AREA ELECTRONICS ZONE MAHAPE NAVI MUMBAI ELECTRONIC ZONE THANE MAHARASHTRA 400710 | THANE | MAHARASHTRA | 400710 | Make: NA
Model: MAESTROS MODEL MIP100 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
30 Jun 2018, 6:00 pmClosed
Infusion Pump Volumetric/Syringe Based Infusion Pump Volumetric/Syringe Based ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values Standards Availability of any of Certification such as ISO/European-CE US-FDA/CE YES YES Details of the Certifications such as type of certification
nu mber
date and validity - - Conformity to Standards YES - Performance Parameters Type of Infusion Pump Syringe Infusion Pump Volumetric Infusion Pump
Syringe Infusion Pump Technology (of operation) Programmable Mode Programmable Mode
Continous Mode Flow rate Range with increment in ml/hr 0.1 to 240 ml/hr(10 ml syringe) 0.1-99.9 ml/hr(0.1 ml/hr increment) for Volumetric Infusion Pump Only
1-1200 ml/hr(1 ml/hr increment) for Volumetric Infusion Pump Only
0.1 to 240 ml/hr(10 ml syringe)
1.1 to 400 ml/hr(20 ml 1/6 syringe)
1.1 to 600 ml/hr(30 ml syringe)
1.1 to 840 ml/hr(50 ml syringe)
1.1 to 999 ml/hr(100 ml/hr syringe) Infused Volume Range in ml 0.1-999(0.1 ml/hr increment) 0.1-999(0.1 ml/hr increment)
1-9999(1 ml/hr increment) Flow rate & volume flow rate & volume to be infused should be configured to limit the maximum allowable range - KVO (Keep Vein Open) Rate in ml/hr 0.1 Accuracy in % 95 Bolus Type Bolus without volume pre-selection Bolus with volume pre- selection
Bolus without volume pre- selection
Interval Bolus
Purge Bolus ( For Syringe based)
Auto Bolus (For Syringe based) Bolus Rate Range in ml/hr 200 ml/hr for 10 ml syringe 1-600 ml/hr ( for Volumetric type infusion set)
200 ml/hr for 10 ml syringe
360 ml/hr for 20 ml syringe
560 ml/hr for 30 ml syringe
800 ml/hr for 50 ml syringe
999 ml/hr for 100 ml syringe Bolus Volume in ml 0.1 ml to 5 ml in 0.1 ml increments(auto bolus) 0.1-99.9/500 ml
0.1 ml to 5 ml in 0.1 ml increments(auto bolus)
NA for Purge bolus Display Type LCD - Size of Display (length x width) (mm x mm) - - Contents of Display - - Alphanumeric Programming Key Board YES - Operating and Transportation Temperature range - - 2/6 Humidity Conditions (operating and transport & storage) (15 to 90%) YES - Pressure Conditions(operating and transport & storage) (50 to 106 kpa) YES - Power sources Battery operated - Battery Type Reachareable lithium polymer - Battery Rating - - Battery run time at normal delivery rate in hours 5 - Battery run time at highest delivery rate in hours 2-3 hrs - Battery recharge time (full charge) in hours 2 - Power Supply 220-240 V AC
50 Hz) (3 wire grounded system) YES - Eectrical Protection (Class I
Type CF) YES - Fuse Type 220V 2A*2
12V 2A*2 - Maximum Power Consumption in watt 5 - Fitting of device on the IV bottle and bag false - IR Sensor to detect the abnormality in IV Bag or bottle false - Audible and Visual alarm facility Should have an audible and visual alarm wtth automatic pump stop function for the following : pressure drop
air standby
volume infused
door open
battery Pre- alarm
recall
invalid rate
empty etc - Availability of Infusion mode setting(rate mode
drip mode
wait mode
time mode) true - 3/6 Protection against fluid ingress - IP*1 - Protected against vertically falling drops of water YES - Capability of Motioning of empty Intravenous bags or bottles false - Warranty in Years 1 1
2
3
4 Dimensional & Material Parameters Dimension (Excluding power cables)(mm x mm x mm) - - Weight(with clamp base)in kg 2.3 - Material (Outer Shell) ABS PLASTIC - Additional Parameters Pole clamp Multi- function mounting clamp YES - Quick titration of rate or dose with volume timing programming YES - Compatible with any standard (PVC) infusion sets available in local indian market YES - Features : compatible with all standard syringes (b) excellent injection function and operation
even small volume injection is accurate (c) dual cpu monitoring function (d)accurate and sensitive pressure sensor detects occlusion pressure accurately (e) smart pulsation compensation function - No of infusion sets supplied with the single unit 0 - Packing (Individual) YES - Reports Type tests reports from a Central Govt lab OR International Laboratory Accreditation Cooperation (ILAC)or their worldwide affiliated/recognized No - 4/6 labs OR NABL approved lab Test Report No - - Test Report Date - - Name and complete address of the Lab - - Copy of certificates to be provided to buyer on demand after placement of order (Applicable if availability of test report indicated as YES
otherwise put NA) NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Shanti Ram 160012
Store Officer Central Stores Nehru Hospital POST GRADUATE INSTITUTE OF MEDICAL EDUCATION AND RESEARCH
sector 12 CHANDIGARH 10 15 EMD Required No ePBG Required No
220301
GEM/2018/B/31351
GeM Contract
Infusion Pump Volumetric/ Syringe Based
GeM Contract
15 days
Chandigarh; Chandigarh
PRODUCT
Awarded to MEDI WAVES INC
₹2.1 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Syringe Infusion Pump | HK 400 | - | 10 NOS | ₹21,500 | 215,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Infusion Pump Volumetric/Syringe Based Infusion Pump Volumetric/Syringe Based ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values Standards Availability of any of Certification such as ISO/European-CE US-FDA/CE YES YES Details of the Certifications such as type of certification | - | - | - |
| nu mber | - | - | - |
| date and validity - - Conformity to Standards YES - Performance Parameters Type of Infusion Pump Syringe Infusion Pump Volumetric Infusion Pump | - | - | - |
| Syringe Infusion Pump Technology (of operation) Programmable Mode Programmable Mode | - | - | - |
| Continous Mode Flow rate Range with increment in ml/hr 0.1 to 240 ml/hr(10 ml syringe) 0.1-99.9 ml/hr(0.1 ml/hr increment) for Volumetric Infusion Pump Only | - | - | - |
| 1-1200 ml/hr(1 ml/hr increment) for Volumetric Infusion Pump Only | - | - | - |
| 0.1 to 240 ml/hr(10 ml syringe) | - | - | - |
| 1.1 to 400 ml/hr(20 ml 1/6 syringe) | - | - | - |
| 1.1 to 600 ml/hr(30 ml syringe) | - | - | - |
| 1.1 to 840 ml/hr(50 ml syringe) | - | - | - |
| 1.1 to 999 ml/hr(100 ml/hr syringe) Infused Volume Range in ml 0.1-999(0.1 ml/hr increment) 0.1-999(0.1 ml/hr increment) | - | - | - |
| 1-9999(1 ml/hr increment) Flow rate & volume flow rate & volume to be infused should be configured to limit the maximum allowable range - KVO (Keep Vein Open) Rate in ml/hr 0.1 Accuracy in % 95 Bolus Type Bolus without volume pre-selection Bolus with volume pre- selection | - | - | - |
| Bolus without volume pre- selection | - | - | - |
| Interval Bolus | - | - | - |
| Purge Bolus ( For Syringe based) | - | - | - |
| Auto Bolus (For Syringe based) Bolus Rate Range in ml/hr 200 ml/hr for 10 ml syringe 1-600 ml/hr ( for Volumetric type infusion set) | - | - | - |
| 200 ml/hr for 10 ml syringe | - | - | - |
| 360 ml/hr for 20 ml syringe | - | - | - |
| 560 ml/hr for 30 ml syringe | - | - | - |
| 800 ml/hr for 50 ml syringe | - | - | - |
| 999 ml/hr for 100 ml syringe Bolus Volume in ml 0.1 ml to 5 ml in 0.1 ml increments(auto bolus) 0.1-99.9/500 ml | - | - | - |
| 0.1 ml to 5 ml in 0.1 ml increments(auto bolus) | - | - | - |
| NA for Purge bolus Display Type LCD - Size of Display (length x width) (mm x mm) - - Contents of Display - - Alphanumeric Programming Key Board YES - Operating and Transportation Temperature range - - 2/6 Humidity Conditions (operating and transport & storage) (15 to 90%) YES - Pressure Conditions(operating and transport & storage) (50 to 106 kpa) YES - Power sources Battery operated - Battery Type Reachareable lithium polymer - Battery Rating - - Battery run time at normal delivery rate in hours 5 - Battery run time at highest delivery rate in hours 2-3 hrs - Battery recharge time (full charge) in hours 2 - Power Supply 220-240 V AC | - | - | - |
| 50 Hz) (3 wire grounded system) YES - Eectrical Protection (Class I | - | - | - |
| Type CF) YES - Fuse Type 220V 2A*2 | - | - | - |
| 12V 2A*2 - Maximum Power Consumption in watt 5 - Fitting of device on the IV bottle and bag false - IR Sensor to detect the abnormality in IV Bag or bottle false - Audible and Visual alarm facility Should have an audible and visual alarm wtth automatic pump stop function for the following : pressure drop | - | - | - |
| air standby | - | - | - |
| volume infused | - | - | - |
| door open | - | - | - |
| battery Pre- alarm | - | - | - |
| recall | - | - | - |
| invalid rate | - | - | - |
| empty etc - Availability of Infusion mode setting(rate mode | - | - | - |
| drip mode | - | - | - |
| wait mode | - | - | - |
| time mode) true - 3/6 Protection against fluid ingress - IP*1 - Protected against vertically falling drops of water YES - Capability of Motioning of empty Intravenous bags or bottles false - Warranty in Years 1 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 Dimensional & Material Parameters Dimension (Excluding power cables)(mm x mm x mm) - - Weight(with clamp base)in kg 2.3 - Material (Outer Shell) ABS PLASTIC - Additional Parameters Pole clamp Multi- function mounting clamp YES - Quick titration of rate or dose with volume timing programming YES - Compatible with any standard (PVC) infusion sets available in local indian market YES - Features : compatible with all standard syringes (b) excellent injection function and operation | - | - | - |
| even small volume injection is accurate (c) dual cpu monitoring function (d)accurate and sensitive pressure sensor detects occlusion pressure accurately (e) smart pulsation compensation function - No of infusion sets supplied with the single unit 0 - Packing (Individual) YES - Reports Type tests reports from a Central Govt lab OR International Laboratory Accreditation Cooperation (ILAC)or their worldwide affiliated/recognized No - 4/6 labs OR NABL approved lab Test Report No - - Test Report Date - - Name and complete address of the Lab - - Copy of certificates to be provided to buyer on demand after placement of order (Applicable if availability of test report indicated as YES | - | - | - |
| otherwise put NA) NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Shanti Ram 160012 | - | - | - |
| Store Officer Central Stores Nehru Hospital POST GRADUATE INSTITUTE OF MEDICAL EDUCATION AND RESEARCH | - | - | - |
| sector 12 CHANDIGARH 10 15 EMD Required No ePBG Required No | - | - | - |
Exempted
28 Aug 2018
18 Jun 2018
contract_GEMC-511687714096638.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_220301.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .