Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.1 LAccepted-AOC 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹51.5 L+₹2.5 L (5.01%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹52.2 L+₹3.1 L (6.35%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹52.9 L+₹3.8 L (7.69%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹53.3 L+₹4.2 L (8.62%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
17 Jun 2024, 6:00 pmClosed
GE (AF) HASIMARA
GE (AF) HASIMARA PO-HASIMARA DIST- ALIPURDUAR PIN-735215
REPAIRS/MAINT OF SANITARY FITTINGS, PLUMBING AND FLOORS OF WASHROOM AND ALLIED WORK, REPAIRS/ MAINT OF BLDG ROOFS INCLUDING CLEANING OF ROOF TREATMENT AT KV ARE, REPAIR / REPLACEMENT OF DETERIORATED/ DAMAGED CI / DI NETWORK OF MAIN WATER SUPPLY LINE
2024_MES_655965_1
C/8763/2024-25/E8
Open Tender
Civil Works
Item Rate
210 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹97,000
Yes
22 Jul 2024
25 May 2024
24 Jun 2024
25 May 2024
17 Jun 2024
10 Jun 2024
Amount
Taking down 15mm bore steel water tubing and connection from wall /ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed.
S&F steel water tubing and connection, medium grade, 15mm bore with all fitting fixed to wall or in ceiling complete all as specified and as directed.
Re-fixing old steel tubing and connection, 15mm bore, in new or old position with new fittings, complete on wall, ceiling or laid in floors etc, complete all as specified and directed. (Note : Serviceable steel tube obtained from taking down shall be re-used)
Taking down 20mm bore steel water tubing and connection from wall /ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed.
S&F steel water tubing and connection, medium grade, 20mm bore with all fitting fixed to wall or in ceiling, complete all as specified and directed.
Re-fixing old steel tubing and connection 20mm bore in new or old position with new fittings, complete on wall, ceiling or laid in floors etc, complete all as specified and directed. (Note : Serviceable steel tube obtained from taking down shall be re-used)
S&F in repair 15mm bore, fancy type, chromium plated, stop valves,concealed type, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or union, complete all as specified and directed.
S&F in repair 15mm bore angular stop cock, chromium plated, cast copper alloy, screwed down, high presure with crutch or butterfly handle screwed both ends for iron pipe or union, complete all as specified and directed.
S&F in repair 15mm bore bib taps, cast copper alloy, chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule, compelete all as specified and directed.
S&F in repair for 125mm size, brass chromium plated shower roses, compelete all as specified and directed.
S&F vitreous china wash hand basin white flat back of size 550x 400mm including PVC waste pipe 32mm dia, waste coupling including cutting for and pinning in ends of brackets etc including dismantling the existing basin, complete all as specified and directed.
S&F in repair CP pillar tap, 15mm bore, capstan head, screwed down high pressure with or without lettered “hot’ or “ cold” with long screwed shanks and fly nuts screwed for iron pipe, complete all as specified and directed.
S&F in repair of 32mm size PVC solid waste pipe, 800mm long for wash hand basin and sink, complete all as specified and directed.
S&F in repair vitreous china squatting pan ,"Orissa pattern" white, size 580x 440mm with integral foot rest, 'P' or 'S' trap, including connection to trap, and to flushing pipe, CI anti -syphonage pipe, complete all as specified and directed.
S & F in repair vitreous china wash down water closet (pedestal), white (EWC) including plastic seat of same colour of WC, closed patttern with flat bottom, and cover and Mild steel chromium plated hinging device, complete all as specified and directed.
S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm bore, complete all as specified and directed.
S&F in repairs for 15mm dia pipe, health faucet (ABS Body) mild steel chromium plated suitable with 1.25 metre long flexible tube and ABS wall hook including makeing connection and fixed in position, complete all as specified and directed.
S&F in repair 10 ltrs capacity low level valve less PVC syphonic action type flushing cistern white with in let, ball valve, float and handle, complete all as specified and directed.
S & F in repairs 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends, complete all as specified and directed.
S&F in repair sinks made of stainless steel with draining board 1mm thick with plugs and wastes including in cement mortar onto dwart wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm including waste pipe & coupling 32mm, complete all as specified and directed.
S&F in repair sinks made of stainless steel 1mm thick with plugs and wastes including in cement mortar onto dwart wall or including fixing cantilever brackets and connecting union to pipe overall size 495mmx410mm bowl size 410mmx330mmx160mm including waste pipe & coupling 32mm, complete all as specified and directed.
S&F in repair stainless steel plate rack of size 0.75 x 0.78m standard quality, weight not less than 6 kg, fixed with brass screws, complete all as specified and directed.
S&F in repair towel rail, 60cm long PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms), complete all as specified and directed
Dismantling of floor, hearth or wall tiles including cement mortar bedding ( but not backing) and remvoing rubbish off the premishes, complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement of match the surfaces over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
M&L glazed ceramic coloured tiles in vertical surface 350x 250x 7mm/450x 350x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering back coat in CM (1:4), complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks, triple layered, (cylindrical vertical with closed top) ISI marked, confirming to IS 12701-1989, hoisted and fixed in position all as specified in SSR Part I (500 ltr capacity) including 20mm Nipple suitable for HDPE water tank and ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed to 20mm bore pipe inculding dismantling of old water tank, complete all as specified and directed.
S & F in repair, 20mm bore, ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms), complete all as specified and directed.
S&F in repair of PVC/plastic lid/cover for 500/1000/2000 Ltrs capacity rotational moulded polyethylene water storage tanks, complete all as specified and directed.
S&F in repair of 32mm waste coupling of PTMT suitable for WHB (half full threaded) (minimum wt 45 gms), complete all as specified and directed.
S&F in repair of 40mm waste coupling of PTMT suitable for WHB (half full threaded) (minimum wt 60 gms), complete all as specified and directed.
Taking out old damaged tarfelt or membran of any description including screed bed or bedding layer and removing of debris to a distance exc. 100m and n. exc. 250m and cleaning roof surfaces to remove all loose dust etc., roughening surfaces of old concrete roof by picking, sweeping clean and washing down with water using wire brush, brooming down and applying the following treatment all as directed in order of precedence as stated: (a) Brushing neat cement slury with 3.0 kg of cement per Sqm. (b) 15mm thick screed bed or bedding layer in CM (1:4) mixed with water proofing compound as per manufacturer instruction on existing roof surface true to level. (c) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm confirming to IS-3384. (d) Supply and laying 3mm thick APP based polymeric membrane of approved manufactured with weight not less than 3.50 Kgs per Sqm reinforced with non-woven polyester fabric weighing not less than 160gms per Sqm having softening point not less than 15°C, having tensile strength of 650 N/Sqcm and 350 N/Sqcm in longitudinal and transverse directions respectively of the reinforced tearing strength of 180 N by torch application. Polymeric membrane shall be taken to a height of 30cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (e) Applying one coat of aluminium paint @ 0.11 Kg/Sgm over APP membrane surface. Note:- (i) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (ii) A minimum overlap of 150mm and 100mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction. (iii) APP based polymeric membrane shall be of any one of the approved makes as specified here-in-after and shall conform to specifications given in IS 16540-2017/1S 16532 2017. (iv) Contractor shall produce necessary test certificate of the manufacturer to the Engr-in-Charge before incorporation in the work. (v) Necessary independent tests shall also be carried out by the contractor without any extra cost to the Deptt as per relevant IS specifications and membranes with satisfactory test results shall only be incorporated in the work. (vi) The work shall be executed through authorised applicators of original manufacturer only. (viI) WPC shall be measured and paid separately as supply only.
Removal of vegetation/grass etc including cutting holes into or through brick walls/concrete and removal of small trees/woods etc and making good distrubed surfaces with cement with PCC (1:2:4) type B-0 (using using 12.5mm graded crushed stone aggregate), surface area n. exc. 0.5 Sqm, complete all as specified and directed.
Cleaning/Uprooting of vegetation/small trees, muds, garbages, waste etc growth on inaccessible RCC roof, AC sheet roof, below wind tie, cleaning of AC sheet/CGI sheet, valley gutter and shaft portion of wall surfaces, back side of toilet portion, complete all as specified and directed.
Demolition of reinforced cement concrete(reinforcement cut as required to facilate demolition) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan exc 6 mtr mean radius built in CM (1:4), complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repair, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified and directed. (Note : Cleaning, repairing, etc. shall be measured and paid separately)
S&F in repairs 20mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe, complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces incl racking out joints hacking for key scrubbing down with water etc, complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:6) other than fair faces of brick work or concrete surfaces, rendering finished even and smooth (without using extra cement) as in ceiling, complete all as specified and directed.
M & L for rendering 15mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces of wall in CM (1:4), mixed with integral water proofing compound top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement, complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item as supply only.)
M&L for rendering 5mm thick in CM (1:3) on fair faces of brick work or concrete surfaces, rendering finished even and smooth (without using extra cement) as in ceiling, complete all as specified and directed.
Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification, complete all as directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistance primer, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed.
S&F pre painted galvalume aluminium zinc coating, GI based corrugated steel sheet 0.50mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws including dismantling of old CGI sheet of any thickness complete all as specified and directed.
S&F pre painted galvalume aluminium zinc coating, GI based plain steel sheet 0.50mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws including dismantling of old PGI sheet of any thickness , complete all as specified and directed.
M&L for 4mm thick pre-painted E-fibre board, designer/decorative, fixed or laid/inserted to GI snap grid frame size 610mm x 610mm work for false ceiling hangers with 4mm to 6mm dia. G.I. (length as required) adjusting level, fixed to roof slabs/truss by means of ceilling cleats made out of G.I. flat 40 x 3mm size 60mm long and expansion hold fasteners, 12.5mm dia, 40mm long including necessary dismentaling of existing unserviceable ceiling boards of any thickness including cover fillets, complete all as specified and directed.
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m in deep for foundation etc. or for shaft, wells, cesspits, manhole, pair house etc. n. exc. 10 Sqm on plan and getting out in soft/loose of soil, complete all as specified and directed.
Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed.
Horizontal boring under the road (with manual method) below 1m from the road surface and dia of hole exc. 100mm but not exc.250mm, with out damaging the existing road, getting out and disposal of soil to a distance not exceeding 50m from the site of work, complete all as specified and directed.
M & L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) for making good to disturbed surface of road etc., complete all as specified and directed.
M & L for 100mm bore, ductile iron pipe (K-7), socket and spigot end with internal cement mortar linning and external bitumen coating for potable water supply with rubber ring joints including cost of rubber rings and commissioning as per technical specification etc laid in trenches including taking out/down old unserviceable pipe any type, complete all as specified and directed. (Note : Excavation and earth work shall be measured and paid separately under respective items ).
All as per itme No 57.00 here-in-before but 150mm bore, complete all as specified and directed.
Attending pipeline breakdown of CI/DI/GI pipe of 80/100/150/200mm dia by making lead joint with lead and spun yarn and moulding clay including takin up/down pipe using chain pulley or rope and excavation in any type of soil including returning filling and removal of soil and testing of pipe line, complete all as specified and directed. Note : Lead joint /titon joint/material/fitting/pipeline shall be measured and paid seperately.
M & L for Jointing DI pipe of 80mm bore by making rubber tyton joint with rubber seal gasket joint for DI pipe line, complete all as specified and directed. Note : Cost of Materials like tyton ruber, gasket ,grease etc shall deemed to be included in the unit quoted rate.
All as per itme No 60.00 here-in-before but 100mm bore, complete all as specified and directed.
All as per itme No 60.00 here-in-before but 150mm bore, complete all as specified and directed.
S&F GI flange for 80mm bore pipe, heavy duty with suitable size nuts and bolts and double washers including 6 mm thick rubber gasket including taking out unserviceable one, complete all as specified and directed.
S&F 150mm bore cast iron sluice valve class PN 1.6 conformig to IS - 14846 clockwise dosing with flanged ends and iron wheel including necessary joints by means of bolts, nuts washers and rubber gaskets including taking down old unserviceable sluice valve of any size from existing position, complete all as specified and directed.
All as per itme No 64.00 here-in-before but 100mm dia, complete all as specified and directed.
M & L for run lead joints in position for cast iron spigot and socket ends for size 150mm bore, complete all as specified and directed.
All as per itme No 66.00 here-in-before but 100mm bore, complete all as specified and directed.
All as per itme No 66.00 here-in-before but 80mm bore, complete all as specified and directed.
All as per itme No 66.00 here-in-before but 200mm bore, complete all as specified and directed.
M & L DI fitting (K-12) for bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch. "Y" junction, double branch, cross (flange sockets or socket and spigot) collars, caps and plugs size up to 200mm bore, complete all as specified and directed.
M & L CI fitting for bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch. "Y" junction, double branch, cross (flange sockets or socket and spigot) collars, caps and plugs size up to 200mm bore, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 Sqmm 3.5 core including taking down old unserviceable UG cable of any description, complete all as specified and directed.
All as per itme No 72.00 here-in-before but 120 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 72.00 here-in-before but 70 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 72.00 here-in-before but 50 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 72.00 here-in-before but 35 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 72.00 here-in-before but 25 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 72.00 here-in-before but 16 Sqmm 4 core, complete all as specified and directed.
M&L for lifting, and relaying the existing PVC/XLPE insulated, armoured, heavy duty electric cable with aluminimum conductor, 1100 Volts grade, in trenches/fixed on wall for cross- sectional area of cable of size from 300 Sqmm to 400 Sqmm 3.5 core, complete all as specified and directed. Note: (i) Necessary earth work shall be measured and paid separately. (ii) Unit quoted rate shall deemed to be include the cost of lugs of suitable size and cable gland irespective of length of cable etc .
All as per itme No 79.00 here-in-before but 185 Sqmm to 240 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 79.00 here-in-before but 70 Sqmm to 120 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 79.00 here-in-before but 35 Sqmm to 50 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 79.00 here-in-before but 16 Sqmm to 25 Sqmm 3.5/4 core, complete all as specified and directed.
All as per itme No 79.00 here-in-before but 10 Sqmm to 16 Sqmm 2 core, complete all as specified and directed.
Supply and laying in trenches/fixed on wall 80mm bore GI tubing, light grade, with necessary fittings such as bend, tee, elbow etc for protection of LT UG cable, complete all as specified and directed.
Supply and laying in trenches/fixed on wall 50mm bore GI tubing, light grade, with necessary fittings such as bend, tee, elbow etc complete for protection of LT UG cable, complete all as specified and directed.
Supply and laying in trenches/fixed on wall 40mm bore GI tubing, light grade, with necessary fittings such as bend, tee, elbow etc complete for protection of LT UG cable, complete all as specified and directed.
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm dia conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed.
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 50mm dia conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed.
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 75mm dia conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed.
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 120mm dia conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed.
Supply and laying well burnt sub class 'B' bricks, old size, laid in trenches perpendicular to UG cable above sand cushioning for cable protection, complete all as specified and directed.
Laying only old bricks sub class 'B' above sand cushioning (width of brick along the length of cable) for cable protection, complete all as specified and as directed. (Note : Old serviceable bricks obtained during taking out of old UG cable shall be re-used)
Supply, filling in trenches, spreading, leveling sand cushioning 8cm below cable and 15cm above the cable punned down to 18cm for under ground cable, complete all as specified and directed. (Note : Punned thickness shall be measured for payment)
S&F water proof junction box made from SMC sheet ready made of size 350 x 270 x 210mm with aluminium bus bar of 150 Amp capacity for RYB and neutral fixed inside the junction box with necessary supporting insulators fixed on hylem sheet/insulating sheet, MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete, entire assembly fixed to pole/wall with MS clamp 25 x 5mm and nuts & bolts and connecting cables from junction box to fittings including dismantling of old junction box of any size, complete all as specified and directed.
All as per itme No 95.00 here-in-before but 400 x 300 x 190mm and bus bar capacity 200 Amps, complete all as specified and directed.
Horizontal boring under the road (with manual method) below 1mtr from the road surface and dia of hole not exc 100mm, with out damaging the existing road, getting out and disposal of soil to a distance not exceeding 50m from the site of work, complete all as specified and directed.
Supplying, installing, testing and commissioning of outdoor type LT feeder piller box made out of 3.0mm thick CRCA sheet out door type, CPRI approved ,totally enclosed weather dust and vermin proof as per IS with front and rear 400 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary made out of 50 x 50 x 6mm angle iron grouted at floor above 30cm from ground level including PCC, (1:3:6) in foundation comprising the following including taking down old unserviceble LT feeder piller box , complete all as specified and directed. Note: Cost includes necessary internal wiring for meters, indication lamps etc and rigid bus bar connections from bus bar to MCCB terminals connection bus to MCCB/MCB connections. BUS BAR CHAMBER:- (a) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid aluminium bus bars, rated 400 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification. INCOMER (a) MCCB of 4 pole of capacity 250 amps with breaking capacity of 25 KA-01 No. INDICATING DEVICES (a) LED Indicating lamps for Main Supply indicating R', Y' B' OUTGOING FEEDERS (a) MCCB of 4 pole of capacity amps with breaking capacity of 16 KA -06 Nos
M&L straight through joints (epoxy) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium conductor nominal cross sectional area 16 to 35 Sqmm 3.5/4.0 core and testing, complete all as specefied and directed.
All as per itme No 99.00 here-in-before but cross sectional area 50 to 70 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 99.00 here-in-before but cross sectional area 95 to 120 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 99.00 here-in-before but cross sectional area 240 to 300 Sqmm 3.5 core, complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized strip of size 25 x 4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Part - I, including necessary excavation and earth work, PCC (1:3:6) type C-I with 50mm thick Pre-cast RCC (1:2:4) type B-I cover slab (reinforced with 8mm dia deformed bar @ 15cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the earth electrode, with funnel and 20mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including taking down old unserviceable earthing of any description, complete all as specified and directed. Note : Proper earthing pit should be provided with pit cover.
S&F in repair MCCB 415 V of capacity 63 Amps 4 pole 16 KA with thermal magnetic protection unit, complete all as specified and directed.
All as per itme No 104.00 here-in-before but capacity 100 Amps 4 pole 16 KA with thermal magnetic protection unit, complete all as specified and directed.
All as per itme No 104.00 here-in-before but capacity 125 Amps 4 pole 16 KA with thermal magnetic protection unit, complete all as specified and directed.
All as per itme No 104.00 here-in-before but capacity 160 Amps 4 pole 25 KA with thermal magnetic protection unit, complete all as specified and directed.
All as per itme No 104.00 here-in-before but capacity 200 Amps 4 pole 25 KA with thermal magnetic protection unit, complete all as specified and directed.
All as per itme No 104.00 here-in-before but capacity 250 Amps 4 pole 36 KA with thermal magnetic protection unit, complete all as specified and directed.
All as per itme No 104.00 here-in-before but capacity 320/350 Amps 4 pole 36 KA with thermal magnetic protection unit, complete all as specified and directed.
All as per itme No 104.00 here-in-before but capacity 400 Amps 4 pole 36 KA with thermal magnetic protection unit, complete all as specified and directed.
Note: An amount of Rs.90,444.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S SARDAR MAL NAHATA
M/S BISHAL ENTERPRISES
M/S. NARENDRA KUMAR GARG
B L SHARMA
M/S BIJAY KUMAR SHIVA
SHRI D P AGARWAL
Shri T P ANIL KUMAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .