Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹34.3 L+₹9.5 L (38.1%)Rejected-Finance | L2 | Rejected-Finance BIDDER NOT LOWEST |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
19 Sept 2022, 6:00 pmClosed
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
REPAIR REPLACEMENT OF DI/GI PIPE LINE AND CLEANING OF UG SUMP WATER TREATMENT CHEMICAL AND CONNECTED FITTING FIXTURES AT SALARIA OFFICERS ENCLAVE AT DWARKA UNDER GE WEST DELHI CANTT 10
2022_MES_520782_1
GE/DW-60/2022-23
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹96,000
27 Oct 2022
23 Aug 2022
21 Sept 2022
24 Aug 2022
19 Sept 2022
6 Sept 2022
Amount
M & L for Taking out old filter media of pressure filter from reverse osmosis RO system, cleaning of Mild steel vessel washing down the filter media with approved chemical as directed, completely from inside, removing of all dust, sludge and greasy particles from cylinderical vessel of pressure filter and Size : 2 Mtr Height X 2.86 Mtr circumfrance and replacing the filter media with new gravels with activated carbon media of fine quality as approved etc, as per existing thickness and removing to a distence not exc 50 mtr in layer exc 30 cm thick as directed Writing number and maintenance date on outer steel surface with synthetic enamel paint complete all as specified and directed. Note: replaced Parts will be measured and paid seperately.
M&L Pressure Sand Filter for existing RO system complete all as specified and directed.
M&L Activate Carbon Filter for existing RO system complete all as specified and directed.
M&L Pre Filter 20 X 20 Micron PP Filter for existing RO system complete all as specified and directed.
M&L Grundfos Pump for existing RO system complete all as specified and directed.
M&L Feed Pump for existing RO system complete all as specified and directed.
M&L Membrain 80x40 for existing RO system complete all as specified and directed.
M&L Pressure Meter for existing RO system complete all as specified and directed.
M&L Automatic on & off System for existing RO system complete all as specified and directed.
M&L for preperation of old steel surfaces and applying two coat of synthetic enamal paint on RO system complete all as specified and directed.
M & L for Detecting leakage of water supply pipe lines of Galvanised iron/PPR of size 150 mm bore from any location, any depth and repairing by providing jointing material,"D" joints, union, clamps, nuts, washers & bolts and including any GI fittings etc. complete all as directed and specified including earth work etc.
All as per Srl item No.11 here -in - before but 80 to 100 mm bore
All as per Srl item No.11 here -in - before but 40/ 50 mm bore
All as per Srl item No.11 here -in - before but 20/ 25 mm bore
Taking up/down ductile iron water mains pipe (including all fittings),with spigot and socket ends, tyton Joints for the following sizes of pipes :-
100 mm dia bore
150 mm dia bore
Supply & Laying, joint, testing and commissioning DI pipes with tyton joints Centrifugally cast , internal cement mortar lining ,external zinc coating with finishing layer of bitumen , pressure pipe socket and spigot end confirming to IS 8329-2000, with ISI marked suitable for K-9 in stranded length of the following size including necessary rubber gasket / tyton jointing material complete all as specified and directed:-
150 mm bore
100 mm bore
Taking up/down PVC/UPVC/GI pipes any grade for water mains (including all fittings),including solvant/ solution for joints as in socket/Tees/Elbows etc. complete all as specified and directed for the following sizes of pipes :-
100/110 mm dia bore
50/63 mm dia bore
25 mm dia bore
Supplying,laying and testing complete 3 layer PP-R (Polypropylene Random Copolymer) concealed pipes conforming to IS:15801 SDR 7.4 (PN-16) UV stabilised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random including all fittings are (PN-25) such as elbow,tees,bends,shaddles laid in trenches or fixed on wall etc incl taking and connecting branch connections from existing PVC or GI mains pipe line complete all as specified and directed for following outer dia of pipes:- Make : SFMC,Supreme,Ajay Note : The contractor shall submit PPR pipes approved by Central Building Research of India (CBRI) certifications,three years Warranty,testing reports and Original purchase voucher which shall be returned to the contractor duly defaced.
110 mm dia bore
63mm dia bore
25 mm dia bore
Taking up or down GI tubing and connections in trenches or surface of wall including removal to store for sch of credit complete all as specified and directed for following size :-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
80 mm bore
100 mm bore
Supply and laying GI tubing medium grade with necessary fittings such as bend, tee,elbow etc in trenches/fixed on wall complete all as specified and directed for the following sizes.
15 mm bore/dia
20 mm bore/dia
25 mm bore/dia
40 mm bore/dia
80 mm bore/dia
100 mm bore/dia
M&L in replacemment PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed for following sizes:-
25 mm dia bore
20 mm dia bore
Supply and fix in replacemment gun metal gate valve with iron wheel head screwed both end for iron pipe complete all as specified and directed for following sizes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
M&L for construction of brick masonnary with full brick wall chamber size of 900x900x900mm internal dimension with earth work in any type of soil , PCC M-10 (Nominal Mix ) type C-2 as in foundation , brick work in CM1:4, 15mm thick plaster in CM1:4 internally and externally , flush pointed in same mortar as work proceeds , 75mm thick PCC coping all around M-15 (Nominal Mix ) with 20mm stone aggregate , flooring shall 40mm thick PCC M-15 (Nominal Mix ) laid over 75mm thick hard core. Top cover shall be made out of MS sheet 3mm thick fixed in angle iron frame made out of angle iron size 40x40x6mm with two numbers of hinges on one side and locking arrangement at other side complete including painting with two coats of synthetic enamel paint over a coat of red oxide primer including dismentaling/ taking out old chamber complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (20 mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (40 mm graded stone aggregate) as in foundation Complete all as specified and directed.
S&F in repairs of CI butterfly valve with CI ring, flanged and drilled 150 mm bore, class PN-1.6, long body type, with SS spindle specified as per IS: 14846 with joint connecting materials complete all as specified and directed.
All as per Item 55 above but 100 mm bore.
Supply and fixing in repairs CI sluice valve cast iron body, flanged and drilled, 80 mm bore , confirming to IS - 14846, Class PN -1.6, long body type etc with jointing materials complete all as specified and directed.
All as per Item 57 above but 100 mm bore.
M&L for taking out submersible pump set of capacities 5HP of any make, type,size from underground sump / well , transport to workshop for repairs , and re-assembling after carrying out repair and lowering/ installing the same at its original location connecting to the existing pipe lines electrically and mechanically , making proper alignment , testing and commissioning to the entire satisfaction of Engineer-in- Charge. NOTE:- Winding & Spare Parts shall be measured & paid seperatly under respective items here-in-after.
M&L for Cutting out the burnt winding of all the three phases of stator of motor of capacities 5HP , taking out burnt copper wire from the slots cleaning the slots properly, rewinding the three phases with original gauge, super enameled copper winding wire including insulating materials i.e., varnish, cotton tape, insulating paper, sleeves drying the windings to require temperature, reassembling the rotor and stator after cleaning and dusting of rotor to remove the settled dust particles complete all as specified and directed.
Excavating in trenches, in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removal of surface soil to a distance n.exc 50 m and deposited where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed.
M&L for disconnecting GI tubing and float valve assembly from the PVC OH tank of Capacity 300 ltrs to 1000 ltrs ,decanting water and removing all scales,dirt with nylon/coconut fiber brush from the tank and washing with bleaching powder to the entire satisfaction of Engineer-in-Charge.After cleaning, tank shall be refixed at existing location and recoonecting with all existing GI tubing and float valve assembly with new washers complete all as specified and directed.
M&L in repairs 300 ltrs capacity , ISI marked Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete complete all as specified and directed.
M&L in repairs top cover suitable for 300 to 500 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) fixed in position including locking arrangement complete all as specified and directed.
M&L for dismantling of impeller of centrifugal pump Cap -30 HP and replacement of the same with bronze impeller closed vane type suitable for centrifugal pump as recommended by manufacturer complete all as specified and directed. Make : Kirloskar or equivalent as approved
All as per item No: 67 but Cap -10 HP
M&L in repairs GI pipe 50 mm bore, heavy grade flanged on both sides fixed with new nuts & bolts, washers, gasket packings, etc. and testing complete including taking down existing GI pipe complete all as specified and directed.
S&F in repair foot valve flanged of size 100 mm fixed with new nuts & bolts, washers, gasket packings, etc. complete all as specified and directed.
M&L Taking down of 30 HP motor, removing to the work shop for dismantling and taking down of winding of motor 30 HP capacity rewinding with appropriate size of super enamelled copper winding wire as per existing no of wires insulated with insulation varnish including all sleeves, insulation paper etc and brought back to the plant,refixing at the site with new nut,bolts,washers,etc and testing complete all as specified and directed.
All as per item No: 71 but Cap - 10 HP
S&F in replacement fully automatic star delta starter suitable for motor of capacity 30 HP including contactors and wiring with suitable size of copper wire complet all as specified and directed.
S&F in replacement fully automatic star delta starter suitable for motor of capacity 10 HP including contactors and wiring with suitable size of copper wire complet all as specified and directed.
S&F in replacement fully automatic star delta starter suitable for motor of capacity 5 HP including contactors and wiring with suitable size of copper wire complet all as specified and directed.
M&L in replacement Submersible copper cable 3 core 16 sqmm including connectors complete all as specified and directed.
M&L for earthing complete with GI earth plate electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 Mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 Mtrs below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using GI strip 32 x 6 mm by means of bolts, nuts, chuck nuts, and washers made of galvanized iron and protected by medium grade 50 mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 type B-1 including necessary form work,excavation and earth work, disposal of surplus soil two a distance not exc. 50 Mtrs complete all as specified and shown on plate No 3 of SSR – Part I 2009.
S&F in replacement Ball PVC valves, with polythene float and flynut complete, screwed for iron pipe ferrule and fixed, 20/25 mm size complete all as specified and directed.
S&F CI water meter size of 100 mm dia confirming to IS-2373 Bulk enclosed Dry dial Type immideadte running capacity 100000L/Hr and Nominal Capacity at 200000 L/Hr duly tested by authorised Dilhi Jal Board agency
Supply only hypo solution, sodium hypochlorite solution of chlorine concentration not less than 10% V/V in chlorine dozer at the predetermined rate so as to get chlorine ppm level of 1 ppm at the pumping station and not less than 0.3 ppm at the farthest consumer complete all as specified .
Supply only PH correction chemicals (Soda Ash) for smooth functioning of RO plant complete all as specified .
Supply only Crystal Alum complete all as specified .
Supply only TDS meter complete all as specified .
Supply only Chlorine testing meter with liquid OTO (orthotolidine) solution for daily testing complete all as specified .
Supply only PH testing Meter complete all as specified .
Supply only stable Bleaching powder granules/high strength Calcium hypochlorite, dry free flowing and free from lumps,should not induce substances beyond acceptable limit as given in IS 10500 (2012) in treated and disinfected water,shoul be packing in drums 40-45 Kg, available chlorine % by mass Min 65,water insoluble matter max % 6,calcium Hydroxide max % 4,sodium chloride max % 15 complete all as specified and directed.
Supply only consumable anti scalant chemical for preventing scaling of membrane of RO plant complete all as specified.
S&F in replacement of 5 micron cartridge filter operating flow rate 15.0 Cum/ Hr operating pressure 2.5 Kg / Sq Cm, micron rate 5 micron, type of cartridge poly propylene (PP) wound, housing (MOC) polycarbonate complete all as specified .
Supply only consumable grade PH booster chemical (Human consumption grade superior quality) complete all as specified .
S&F in replacement RO membrane (80/40) suitable for RO plant of capacity 7000 LPH capable to deliver 1000 LPH of portable water etc complete all as specified.
S&F in replacement of PVC coupler 40 mm, of pressure not less than 10 Kg/Cm² complete all as specified .
S&F in replacement of ball valve threaded 40mm of pressure not less than 10 Kg/Cm² complete all as specified .
S&F in replacement of PVC pipe 90 mm dia, socketed end, pressure rating not less than10 kg/Cm² complete all as specified .
S&F in replacement of PVC tee 50 mm , of pressure not less than 10 Kg/Cm² complete all as specified .
S&F in replacement of PVC elbow, 50 mm , of pressure not less than 10 Kg/Cm² complete all as specified .
S&F in replacement nylon rope of size 15 mm dia as per existing rope complete all as directed.
S&F in replacement Rota Meter 30-130 LPM complete all as specified .
S&F in replacement Digital PH meter capcity of plant 7000 ltr/Hr complete all as specified .
S&F in replacement Suction 'Y' Type CI Strainer suitable for 100 mm dia complete all as specified .
Deduct Credit: for demolished/dismantled material of (-) Rs 148405.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum.
M/s S.G. BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .