Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹42.3 L+₹3.9 L (10.3%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹44.6 L+₹6.3 L (16.4%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹45.9 L+₹7.5 L (19.6%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹46.8 L+₹8.4 L (21.9%)Rejected-Finance AT ROAD MES TINALI PO CHABUA DISTT DIBRUGARH ASSAM 84 | CHABUA | DIBRUGARH | ASSAM | 786102 | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
20 Jun 2022, 6:00 pmClosed
MAJ JP SAHOO
GE 872 EWS, C/O 99 APO
REPAIRS AND MAINT OF EXTERNAL WATER SUPPLY, REPAIRS MAINT TO LT EXTERNAL ELECTRIFICATION AND REPAIRS MAINT SERVICING OF DG SETS, LT PANELS AND EARTHING AT RAYANG MIL STN UNDER GE 872 EWS
2022_MES_527398_1
8419/T-19/E8
Open Tender
Miscellaneous Works
Item Rate
243 days
RAYANG
All as per NIT and Tender documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹77,000
Yes
22 Jun 2022
30 May 2022
21 Jun 2022
30 May 2022
20 Jun 2022
14 Jun 2022
30 May 2022 - 6 Jun 2022
Amount
EARTH WORKS
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Water Pipe Line, Cable, Electric Post, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Mete for Electric Post, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Water Pipe Line, Cable Line with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
Removal Excavated Materials (Soil) to a distance not exc. 50 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point, complete all as specified and as directed.
REPAIRS & MAINT TO EXTERNAL WATER SUPPLY
Taking up or down Steel Tubing 20mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed.
Taking up or down Steel Tubing 25mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed.
Taking up or down Steel Tubing 40mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed.
Taking up or down Steel Tubing 50mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed.
Taking up or down Steel Tubing 80mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed.
Taking up or down Steel Tubing 100mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed.
Supply & laying Steel Water Tubing 20mm bore (dia), Galvanised, ‘medium grade’ with all Fittings, laid in Trenches or any other situation, complete as all specified and as directed.
Refixing old Steel Tubing 20mm bore (dia) and Connections (Serviceable Pipes and Connections obtained from Item No. 2.01 here-in-before) in New or Old Position (Walls, Floors, Trenches, etc.) including Cleaning both Inner and Outer Surfaces of Pipes by using Wire Brush including provision of New GI Fittings/ Connections (as required/ordered), complete all as specified and as directed.
Supply & laying Steel Water Tubing 25mm bore (dia), Galvanised, ‘medium grade’ with all Fittings, laid in Trenches or any other situation, complete as all specified and as directed.
Refixing old Steel Tubing 25mm bore (dia) and Connections (Serviceable Pipes and Connections obtained from Item No. 2.02 here-in-before) in New or Old Position (Walls, Floors, Trenches, etc.) including Cleaning both Inner and Outer Surfaces of Pipes by using Wire Brush including provision of New GI Fittings/ Connections (as required/ordered), complete all as specified and as directed.
Supply & laying Steel Water Tubing 40mm bore (dia), Galvanised, ‘medium grade’ with all Fittings, laid in Trenches or any other situation, complete as all specified and as directed.
Refixing old Steel Tubing 40mm bore (dia) and Connections (Serviceable Pipes and Connections obtained from Item No. 2.03 here-in-before) in New or Old Position (Walls, Floors, Trenches, etc.) including Cleaning both Inner and Outer Surfaces of Pipes by using Wire Brush including provision of New GI Fittings/ Connections (as required/ordered), complete all as specified and as directed.
Supply & laying Steel Water Tubing 50mm bore (dia), Galvanised, ‘medium grade’ with all Fittings, laid in Trenches or any other situation, complete as all specified and as directed.
Refixing old Steel Tubing 50mm bore (dia) and Connections (Serviceable Pipes and Connections obtained from Item No. 2.04 here-in-before) in New or Old Position (Walls, Floors, Trenches, etc.) including Cleaning both Inner and Outer Surfaces of Pipes by using Wire Brush including provision of New GI Fittings/ Connections (as required/ordered), complete all as specified and as directed.
Supply & laying Steel Water Tubing 80mm bore (dia), Galvanised, ‘medium grade’ with all Fittings, laid in Trenches or any other situation, complete as all specified and as directed.
Refixing old Steel Tubing 80mm bore (dia) and Connections (Serviceable Pipes and Connections obtained from Item No. 2.05 here-in-before) in New or Old Position (Walls, Floors, Trenches, etc.) including Cleaning both Inner and Outer Surfaces of Pipes by using Wire Brush including provision of New GI Fittings/ Connections (as required/ordered), complete all as specified and as directed.
Supply & laying Steel Water Tubing 100mm bore (dia), Galvanised, ‘medium grade’ with all Fittings, laid in Trenches or any other situation, complete as all specified and as directed.
Refixing old Steel Tubing 100mm bore (dia) and Connections (Serviceable Pipes and Connections obtained from Item No. 2.06 here-in-before) in New or Old Position (Walls, Floors, Trenches, etc.) including Cleaning both Inner and Outer Surfaces of Pipes by using Wire Brush including provision of New GI Fittings/ Connections (as required/ordered), complete all as specified and as directed.
S&F Bib Tap 15mm bore (dia), Cast Copper Alloy, screwed down, High pressure, with Crutch or Butter-fly Handle, screwed Both Ends for Unions/ Sockets including Taking down/out Unserviceable Bib Tap of any description, complete all as specified and as directed.
S&F Gun Metal Globe/ Gate Valve 20mm bore (dia) with iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unservice-able Globe/Gate Valve of any description, complete all as specified and as directed
S&F Gun Metal Globe/ Gate Valve 25mm bore (dia) with iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unservice-able Globe/Gate Valve of any description, complete all as specified and as directed
S&F Gun Metal Globe/ Gate Valve 40mm bore (dia) with iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unservice-able Globe/Gate Valve of any description, complete all as specified and as directed
S&F Gun Metal Globe/ Gate Valve 50mm bore (dia) with iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unservice-able Globe/Gate Valve of any description, complete all as specified and as directed
M&L Cast Iron Sluice Valve 80mm bore (dia), Long Body Type, Flanged and drilled both Ends, ISI Marked (IS:14846-2000 & Class PN 1.6) having Cast Iron Hand Wheel, Brass Spindle, Cheek Nuts and Sliding Gate and Body with Mild Steel Bolts & Nuts and Testing against Leakage including Taking out/ down Old Unserviceable Sluice Valve, complete all as specified and as directed.
M&L Cast Iron Sluice Valve 100mm bore (dia), Long Body Type, Flanged and drilled both Ends, ISI Marked (IS:14846-2000 & Class PN 1.6) having Cast Iron Hand Wheel, Brass Spindle, Cheek Nuts and Sliding Gate and Body with Mild Steel Bolts & Nuts and Testing against Leakage including Taking out/ down Old Unserviceable Sluice Valve, complete all as specified and as directed.
M&L Construction Brick Masonry Valve Chamber of Size 75x75x90 Cm (Internal Dimension of Chamber) with Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Foundation, One Brick thick Brick Walls in Cement Mortar 1:4, Rendering 15mm thick on Brick Walls in Cement Mortar 1:4 and all Internal Surfaces except PCC Foundation Bed, Externally upto 150mm below Normal Ground Level, providing Mild Steel Valve Chamber Cover 2.0mm thick with Hinges, Handle and Locking Arrangements with Mild Steel Angle Iron Frame 40x40x5.0mm on Top of Valve Pit, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregate) 100mm thick including applying Two Coats of Black Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer after necessary preparation to all Steel Surfaces Painting, all necessary Earth Work i.e. Excavation in any type of Soil, Returning, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre including Demolition of Damaged Valve Chamber, complete all as specified and as directed.
M&L Construction Brick Masonry Valve Chamber of Size 100x100x90 Cm (Internal Dimension of Chamber) with Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Foundation, One Brick thick Brick Walls in Cement Mortar 1:4, Rendering 15mm thick on Brick Walls in Cement Mortar 1:4 and all Internal Surfaces except PCC Foundation Bed, Externally upto 150mm below Normal Ground Level, providing Mild Steel Valve Chamber Cover 2.0mm thick with Hinges, Handle and Locking Arrangements with Mild Steel Angle Iron Frame 40x40x5.0mm on Top of Valve Pit, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregate) 100mm thick including applying Two Coats of Black Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer after necessary preparation to all Steel Surfaces Painting, all necessary Earth Work i.e. Excavation in any type of Soil, Returning, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre including Demolition of Damaged Valve Chamber, complete all as specified and as directed.
Dismantling Wrought Iron or Mild Steel Work of any description not otherwise provided for, complete all as specified and as directed.
M&L Mild Steel Work such as Bracings, Supports, Clamps and Back Plates, etc., fabricated from Structural Steel Sections including necessary Welding, Bending Cold or Hot, Drilling Holes for Bolts, in any shape or size as indicated or directed including applying Two Coats of Aluminium Paint over a Coat of Red Oxide Zinc Chrome Primer after preparation of Surfaces, complete all as specified and as directed.
M&L Mild Steel Screw Bolts (Machine made) with Hexagonal or Square Heads at One End and screwed the Other, or screwed Both Ends, Each screwed End to be fitted with Washers and One Hexagonal or Square Nut, Length of Bolt of existing Sizes, complete all as specified and as directed.
Supply only Calcium Hypo Chlorite (Altock GP/ Aquafit) 65%-70% Chlorine Content (Calcium based Granuar Disinfectant for Water Treatment (as approved by GE) for Chlorination of Water i.e. 2 PPM at Pump House and 0.2 PPM at User End, complete all as specified and as directed. NOTE : Manufacturer's Test Certificate for Each Lot alongwith Original Purchase Voucher shall be furnished by the Contractor for Payment.
Supply only Bleaching Powder for Water Treatment (as approved by GE) for Chlorination of Water i.e. 2 PPM at Pump House and 0.2 PPM at User End, complete all as specified and asdirected. NOTE : Manufacturer's Test Certificate for Each Lot alongwith Original Purchase Voucher shall be furnished by the Contractor for Payment.
Supply only Alum for Water Treatment (as approved by GE) for Chlorination of Water i.e. 2 PPM at Pump House and 0.2 PPM at User End, complete all as specified and asdirected. NOTE : Manufacturer's Test Certificate for Each Lot alongwith Original Purchase Voucher shall be furnished by the Contractor for Payment.
Supply only Lime for Water Treatment (as approved by GE), complete all as specified and asdirected. NOTE : Manufacturer's Test Certificate for Each Lot alongwith Original Purchase Voucher shall be furnished by the Contractor for Payment.
Supply only Polymer INDFLOC 238 for Water Treatment (as approved by GE), complete all as specified and asdirected. NOTE : Manufacturer's Test Certificate for Each Lot alongwith Original Purchase Voucher shall be furnished by the Contractor for Payment.
M&L Cleaning HDPE Water Tank of capacity 5000 Litre and the connected Circulating Pipes at any Position by removing sludge, mud, moss, moulds, efflorescent salts, oil spots, etc. or any other foreign materials from the bottom, cover and internal surfaces by scraping using wire brush, Draining out the water in the Tank and Washing internally by using Bleaching Powder and again Draining out the water in the Tank, Writing Letters "TANK CLEANED ON : DD.MM.YYYY" (i.e. Date of Cleaning of Tank) not exc. 75mm in Height & 15mm Width with White Paint on Black Back Ground, complete all as specified and as directed.
M&L Painting Pressed Steel Storage Water Tank 46800 Litre capacity having 3.00 Metre High Steel Stagging, Removing rust, etc. from surfaces of Storage Water Tank of Outer Walls and Steel Stagging by rubbing with Wire Brush and applying Two Coats of Aluminium Paint on Outer Area of Tank and Steel Stagging, and applying One Coat of Black Bituminous Paint to Inside Portion of Storage Water Tank and all Connected Assesories like all GI Pipes, Valves, Other Fittings, etc., complete all as specified and as directed. NOTE : Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Sump will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.
M&L Dewatering Water from Pressed Steel Storage Water Tank 46800 Litre capacity, having 12.00 Metre High Steel Stagging, Cleaning and Removing all Mosses, Algae, Dirts, etc. from the Walls and Floor of Water Tank, Removal of Dirty Water with Sludges and disposed off from the Site as diredted, Rubbing Walls, Floor, Ceilling surfaces with Gunny Bag after sprinkling of Bleaching Powder and Wash thoroughly with Fresh Water including Cleaning of Outlet Pipes, Stop Valves, Gate Valves by Taking out Pipe Lines with Stop Valves, Gate Valves, etc. and all Accessories, Re-fixing the same after Cleaning including Float Valve with Float Arm to Original Position, Writing Letters "TANK CLEANED ON : DD.MM.YYYY" (i.e. Date of Cleaning), exc. 100mm but not exc. 200mm in height and 15mm in wide with White Paint on Black Back ground on the Front/ Road Side/Face of the Tank, complete all as specified and as directed. NOTE :- (a) Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Steel Storage Water Tank will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account. (b) Cleaning of Steel Storage Water Tank will be carry out for 2 Times within the Contract Period.
REPAIRS & MAINT TO PUMPS AND MOTORS
M&L Dismantling & Removing Defective Electric Motor 3.0 HP Capacity, 3 Phase 210-250 Volt, 50 Hz to AGE E/M Store Yard at RAYANG, Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning Motor as required, Transporting defective Motor to nearest Workshop for Repairing & Rewinding, Taking out burnt Copper Windings, Cleaning of Slots of the Motor, Rewinding Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) including necessary Insulation Materials, Varnishing, Heating, complete, Reassembling the Motor and Testing for Smooth Fucntioning after Repaired & Rewinding, Transporting Motor to Worksite, Re-installed at Site and providing All Connections and Testing, complete all as specified and as directed.
M&L Dismantling & Removing Defective Electric Motor 5.0 HP Capacity, 3 Phase 210-250 Volt, 50 Hz to AGE E/M Store Yard at RAYANG, Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning Motor as required, Transporting defective Motor to nearest Workshop for Repairing & Rewinding, Taking out burnt Copper Windings, Cleaning of Slots of the Motor, Rewinding Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) including necessary Insulation Materials, Varnishing, Heating, complete, Reassembling the Motor and Testing for Smooth Fucntioning after Repaired & Rewinding, Transporting Motor to Worksite, Re-installed at Site and providing All Connections and Testing, complete all as specified and as directed.
M&L Lifting of Submersible Pump & Motor Assembly 7.5 HP capacity alongwith complete Column Pipes, Submersible Cable, Safety Rope, etc. from the existing Borewell by employing Chain Pulley Block, etc., Dismantling Column Pipes by Opening Nuts, Bolts, Pump & Motor, etc, Seggregating & Stacking of Serviceable Column Pipes & Other Materials and Keep in Safe Custody for re-use, complete all as specified and as directed.
M&L Removing Submersible Pump & Motor Assembly 7.5 HP capacity to AGE E/M Store Yard at RAYANG, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning of Cover and Parts as required, Transporting defective Submersible Pump & Motor Assembly to nearest Workshop for Repairs, Repairing & Replacing of Unserviceable Parts, Reassembling Submersible Pump Motor Assembly after repaired, Transporting repaired Submersible Pump Motor Assembly back to Work Site, complete all as specified and as directed. NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to include in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Submersible Pump & Motor Assembly Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department (c) The Cost of Minor Spares Parts/Items viz Nuts, Bolts, Washers, Gasket, etc. will deem to be include in the Quoted Unit Rate. (d) Rewinding of Submersible Motor, wherever invloves will be Measured and Paid separately under relevant Item.
M&L Dismantling Submersible Motor 7.5 HP capacity, Taking out burnt Windings, Cleaning of Slots of the Motor and Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the Same and Testing for Smooth Functioning after Rewinding, complete all as specified and as directed.
M&L Lowering down Submersible Pump & Motor Assembly 7.5 HP capacity (after Repaired & Testing of Functionability) alongwith Column Pipes of any Size and Length, Submersible Cable, Steel Wire Rope, etc. with the help of Chain Pulley Block and Tool & Plants, Testing on Completion, complete all as specified and as directed. NOTE : Serviceable Materials viz Column Pipes and Other Materials, etc. (obtained from Item No. 39 here-in-before) keet in Safe Custody will be reuse. Sumbersible Cable will be replaced with New Cable and the same will be Measured and Paid separately under appropriate Item as 'Supply only'.
M&L Lifting of Submersible Pump & Motor Assembly 12.5 HP capacity alongwith complete Column Pipes, Submersible Cable, Safety Rope, etc. from the existing Borewell by employing Chain Pulley Block, etc., Dismantling Column Pipes by Opening Nuts, Bolts, Pump & Motor, etc, Seggregating & Stacking of Serviceable Column Pipes & Other Materials and Keep in Safe Custody for re-use, complete all as specified and as directed.
M&L Removing Submersible Pump & Motor Assembly 12.5 HP capacity to AGE E/M Store Yard at RAYANG, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning of Cover and Parts as required, Transporting defective Submersible Pump & Motor Assembly to nearest Workshop for Repairs, Repairing & Replacing of Unserviceable Parts, Reassembling Submersible Pump Motor Assembly after repaired, Transporting repaired Submersible Pump Motor Assembly back to Work Site, complete all as specified and as directed. NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to include in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Submersible Pump & Motor Assembly Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department (c) The Cost of Minor Spares Parts/Items viz Nuts, Bolts, Washers, Gasket, etc. will deem to be include in the Quoted Unit Rate. (d) Rewinding of Submersible Motor, wherever invloves will be Measured and Paid separately under relevant Item.
M&L Dismantling Submersible Motor 12.5 HP capacity, Taking out burnt Windings, Cleaning of Slots of the Motor and Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the Same and Testing for Smooth Functioning after Rewinding, complete all as specified and as directed.
M&L Lowering down Submersible Pump & Motor Assembly 12.5 HP capacity (after Repaired & Testing of Functionability) alongwith Column Pipes of any Size and Length, Submersible Cable, Steel Wire Rope, etc. with the help of Chain Pulley Block and Tool & Plants, Testing on Completion, complete all as specified and as directed. NOTE : Serviceable Materials viz Column Pipes and Other Materials, etc. (obtained from Item No. 3.07 here-in-before) keet in Safe Custody will be reuse. Sumbersible Cable will be replaced with New Cable and the same will be Measured and Paid separately under appropriate Item as 'Supply only'.
Supply only Galvanised Iron Steel Pipe 65mm bore (dia), 3.0 Metre in Length as Column Pipe, ISI marked, having both Sides Painted, threaded both Ends including Socket duly screwed, complete all as specified and as directed.
Supply only PVC insulated, sheathed Stranded Copper Conductor Water Proof Cable, Flat, Cross-sectional Area 6.0 Sqmm, 3 Core, 1100 Volt grade, conforming to IS:694, suitable for making Connection to Sumbersible Pump & Motor 7.5 HP Capacity, complete all as specified and as directed.
S&F PVC Insulated, Sheathed LT Flat or Round Weather Proof Stranded Aluminium Cable, Cross-sectional Area 10 Sqmm, 4 Core, 1100 Volt grade, conforming to IS:694 for making Connection to Sumbersible Pump & Motor of any description including Taking out/down unserviceable Cable, complete all as specified and as directed.
S&F Pressure Gauge Diaphram type range 0-7 Kg/Sq Cm including Taking out/ down Unserviceable Pressure Gauge, complete all as specified and as directed.
S&F Automatic DOL Starter 7.5 HP, 415 Volt, 50 Hz with Outgoing and Incoming Cable Connections to the existing Monoblock Pump Set and Testing on Full Load including Taking out/ down Unserviceable Star Delta Starter, complete all as specified and as directed. MAKE : BCH/ HAVELLS/ L&T
S&F Automatic Star Delta Starter 12.5 HP, 415 Volt, 50 Hz with Outgoing and Incoming Cable Connections to the existing Monoblock Pump Set and Testing on Full Load including Taking out/ down Unserviceable Star Delta Starter, complete all as specified and as directed. MAKE : BCH/ HAVELLS/ L&T
REPAIRS & MAINT TO LT EXTERNAL ELECTRIFICATIONS
Dismantling Unserviceable Steel Tubular Pole of any description and any Size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed. NOTE : Unserviceable Pole will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earthwork, Demolition Cement Concrete, etc. will not be Measured and Paid separately.
Dismantling Cross Arms, Mild Steel Channel, Angle Section, Flat Iron, Mild Steel Rod, etc., complete all as specified and as directed.
Taking down Unserviceable Insulator of any Size and any description from LT Electric Poles or from any Situations, complete all as specified and as directed.
Taking down ACSR Conductor including Line Spacers of OH Electric Lines from LT Electric Poles of any Size and capacity, complete all as specified and as directed.
Taking down Unserviceable/rusted GI Earth Wire, Cradles Guards of any Size and shape at any Position from LT Electric Poles of any Size and capacity, complete all as specified and as directed.
Dismantling Stay Assembly complete of any description, complete all as specified and as directed. NOTE : Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earth Works, Demolition of Cement Concrete, etc. will not be Measured & Paid separately.
M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork, complete all as specified and as directed.
M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One Coat of Red Oxide Zinc Chrome Primer, providing 3 No. Band/Strap with Paint Black/Yellow Colour 300mm apart from Plinth Block and numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed. NOTE : Necessary Earth Work & Cement Concrete will be Measured and Paid separately under relevent Items.
M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or Size as indicated or directed and applying Two coats of Aluminium Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of Surfaces, complete all as specified and as directed.
S&F Pin type Insulator 100mm height, 65mm dia for 1100 Volt grade, Porcelain, Vitreous, White, Brown or Green including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut, complete all as specified and as directed.
S&F Insulator Shackle type, Porcelain, Vitreious, White, Brown or Green of Size 75mm High and 90mm dia including Galvanised Mild Steel Straps of Section 31x3.0mm, 12mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 1100 Volt, complete all as specified and as directed.
M&L ACSR Conductor of any Size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed. NOTE : Sizes of Conductor will be as per Site requirement as Ordered.
M&L Restretching, Tightening & Fixing of ACSR Conductor of any Size on LT Electric Poles including necessary Aluminium Binding Wire including Refixing of Connectors, PVC Sleeves for Jumper, etc. complete all as specified and as directed.
M&L Galvanised Iron Wire 4.0mm dia (8 SWG) as Continuous Earth Wire, Guards and Cradles (hexagonal/rectangular), etc. and binding with and including GI Binding Wire 1.6mm dia, complete all as specified and as directed.
M&L Stay Assembly complete with all Accessories such as Mild Steel Galvanised Flat Iron Stay Clamp, Galvanised Stay Wire 7/3.15mm stranded, One Insulator Loop type Porcelain Vitreous (white, brown or green) Overall Dimensions 65x90mm and Clearance of Hole 16mm, Stay Grips, Mild Steel Galvanised Stay Bow, Thimbles Galvanised steel 14mm dia & 400mm long, 16mm dia Mild Steel Galvanised Stay Rod 1900mm long and Mild Steel Galvanised Stay Plate of Size 300x300x6.0mm all as shown in Electrical Plate No. 1 of MES Schedule Part-I, complete all as specified and as directed. NOTE : Necessary Earth Work, Cement Concrete, etc. will be Measured and Paid separately under relevant Items.
S&F Air Breaks Gang Operating Switch 11 KV, Triple Pole with DO Mechani-cally Vertical Operated, mounted on Insulator and Steel Frame with operating mechanism worked from Ground Level for current rating up to 200 Amp includ-ing Taking down Unserviceable GOD, complete all as specified and as directed.
S&F LED Street Light Fitting 60 Watt 230 Volt AC Outdoor type with High Pressure Die Cast Aluminum Housing and Heat Resistant complete with Driver, Lamp Bracket with Impact and Corrosion Resistant including Thermal Manage-ment in Multiple Optics complete with IP-65/66 Protection complete and Electri-cally connecting with suitable Size Copper Conductor Cable including Taking out/ down Unserviceable Light Fitting, complete all as specified and as directed.
S&F Flood Light 120 Watt 230 V AC Outdoor type with Thermal manage-ment in Multiple Optics and equipped with IP-66 Protection, with Impact and Corrosion Resistant complete with Driver and Lamp and Electrically connecting with suitable size Copper Conductor Cable including Taking out/ down Unserviceable Light Fitting, complete all as specified and as directed.
S&F Pole Mounted Junction Box of Size 225x295x122mm made of Engineering Plastic One Piece Moulding having Shock Proof, Rust Proof, Fire Retradrant Non-transparent for Outdoor type, Heavy duty, with 4 No. insulated Alunminium Bus-bar of 60 Amps capacity, mounted on Unbreakable Insulators 10A MCB SP and Complete with Aluminium Lugs of suitable Size upto 50 Sqmm with 2 No. mild Steel FI 40x3mm Clamps, Nuts, Bolts Washers, etc. and duly painted on both Sides with Two Coats of Synthetic Enemel Paint over a Coat of Red Oxide zinc Chrome Primer and Connected including Taking down Unserviceable Junction Box from Pole, complete all as specified and as directed.
S&F PVC Insulated, PVC Sheathed LT Flat or Round Weather Proof Stranded Aluminium Cable, Cross-sectional area 6.0 Sqmm, 2 Core, 1100 Volt grade, Heavy Duty and provding Electrical Connections for Street Light Fittings, etc. including Taking out/down Unserviceable Service Connection Cable, complete all as specified and as directed.
M&L Painting LT Steel Tubular Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with One coat of Aluminium Paints and Numbering of Code in letter Size not less then 50mm in Black Paints and Painting of Pole with Strips 300mm high (5 Nos.) around the Pole with Two different Colour Synthetic Enamelled Paint for Pole 7.5 Metre height above Ground Level, complete all as specified and as directed.
M&L Trimming/Cutting of Tree Branches of any girth/Size and Clearing of LT OH Lines (any Nos. of ACSR Conductors, Earth Wire, etc.) upto 3.0 Metre distance, Removing Tree Branches from the Sites, complete all as specified and as directed.
S&F Fire Exinguiser of 5.0 KG Capacity, ABC type including Taking down Unserviceable Fire Exinguiser of any description from any Situations, complete all as specified and as directed.
REPAIRS & MAINT TO LT CABLES
Disconnecting & Taking down/ out Unserviceable LT Cable of any Size and any description including GI Pipes, Bricks, etc. from Trenches, Floors, Poles, Walls, complete all as specified and as directed. NOTE : Necessary Earthworks will be Measured & Paid under appropriate Items.
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 10 Sqmm, 2 Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 16 Sqmm, 4 Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 35 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 70 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 400 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply & laying Sub-class ‘B’ Bricks of Size 230x115x75 mm, Kiln burnt, for Covering to UG Cable as Protection, laid Flat, Transversally Width Equal to the Length of the Cable, complete all as specified and as directed.
Supply & Laying Unreinforced Pre-cast Concrete Cable Cover of Size 300x180x40mm thick, Class LV, Type 2, Flat, Concrete grade M-20 minimum, complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 50mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable Size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
REPAIRS & MAINT TO PANEL BOARDS, ACCESSORIES & EARTHING
S&F Ammeter 0-50 Amp, Fixing to existing Position and Connecting up including Taking down/ out Unserviceable Ammeter, complete all as specified and as directed.
S&F Voltmeter 0-500 Volt, Fixing to existing Position and Connecting up including Taking down/ out Unserviceable Voltmeter, complete all as specified and as directed.
S&F Contactor suitable for Submerissible Pump 7.5 KW/ 10 HP capacity, Fixing to existing Position and Connecting up including Taking down/ out Unserviceable Contactor, complete all as specified and as directed.
S&F Contactor 4 Pole, AC Supply suitable for Submerissible Pump 11 KW/ 15 HP capacity, Fixing to existing Position and Connecting up including Taking down/ out Unserviceable Contactor, complete all as specified and as directed.
S&F LED Indicator Lamp R-Y-B of any Size, Fixing to existing Position and Connecting up including Taking down/ out Unserviceable Indicator Lamp, complete all as specified and as directed.
S&F Changover Switch 63 Amp, Onload/ Offload (as approved), Fixing to existing Position and Connecting up including Taking down/ out Unserviceable Changover Switch, complete all as specified and as directed.
S&F MCCB 63 Amp to 100 Amp, 3 Pole, 16 kA, 415 Volt, 50 Hz with Thermal Magnetic Trip Unit including Incoming & Outgoing Cable Connections and Fixing to existing Panel Board and Connecting up including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 160 Amp, 4 Pole, 25 kA, 415 Volt, 50 Hz with Thermal Magnetic Trip Unit including Incoming & Outgoing Cable Connections and Fixing to existing Panel Board and Connecting up including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 200 Amp, 4 Pole, 25 kA, 415 Volt, 50 Hz with Thermal Magnetic Trip Unit including Incoming & Outgoing Cable Connections and Fixing to existing Panel Board and Connecting up including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
S&F Thermal Over Load Relay 7 Amp to 10 Amp (as approved), Fixing to existing Position and Connecting up including Taking down/ out Unserviceable Relay, complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of Size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of Size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing including Taking Taking down/ out Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
REPAIRS & MAINT DG SETS
M&L Repairs/Maint & Servicing of DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connection, Engine Control Wirings. (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE : All Spares and Consumable Items such as Distilled Water, Lube Oil, Grease, Filters and Other Spare Parts (Quantitites mentioned Item No. 7.02 to 7.23 here-in-after are Provisional only) are will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only CR Bearing Set (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Cylinder Liner (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Fuel Pump (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Gasket Set (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Governor Assembly (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Idel Gear and Shaft (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Main Bearing Set (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Nozzel Pipe Set (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Piston Assembly (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Piston Ring (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Radiator Assembly (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Starter Filed Coil (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 20 KVA capacity of MAKE : KIRLOSKAR, complete all as specified and as directed.
M&L Repairs/Maint & Servicing of DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connection, Engine Control Wirings. (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE : All Spares and Consumable Items such as Distilled Water, Lube Oil, Grease, Filters and Other Spare Parts (Quantitites mentioned Item No. 7.25 to 7.49 here-in-after are Provisional only) are will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only CR Bearing Set (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Crank Shaft Assembly (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Cylinder Liner (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Fuel Pump (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Gasket Set (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Governor Assembly (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Idel Gear and Shaft (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Main Bearing Set (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Nozzel Pipe Set (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Piston Assembly (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Piston Ring (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Radiator Assembly (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Relay (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Stainer Switch (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Starter Filed Coil (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 30 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
M&L Repairs/Maint & Servicing of DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connection, Engine Control Wirings. (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE : All Spares and Consumable Items such as Distilled Water, Lube Oil, Grease, Filters and Other Spare Parts (Quantitites mentioned Item No. 7.51 to 7.67 here-in-after are Provisional only) are will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Controler Model No. KG934/GC 1202 (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Cylinder Liner (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Governor Assembly (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Main Bearing Set (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Piston Assembly (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Relay (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Stainer Switch (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Starter Filed Coil (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 50 KVA capacity of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
M&L Asbestos Rope (as per existing/ as approved) including Taking down/out Unserviceable Asbestos Rope, complete all as specified and as directed.
S&F Battery 12 Volt, 120 AH Capacity (as approved) and Providing all Electrical Connection including Taking down/out Unserviceable Battery, complete all as specified and as directed. MAKE : EXIDE XPRESS/LUMINOUS/AMRON
M&L Battery Terminal of Copper/Brass (as per existing/ as approved) and connected including Taking down/out Unserviceable Battery Terminal, complete all as specified and as directed.
S&F Digital Battery Charger of 100 to 150 AH Capacity suitable for Charging Battery 12 Volt and Providing All Electrical Connections as required for Battery Charging including Taking down Unserviceable Battery Charger after disconnecting all Electrical Connections and Removing Battery Charger to MES Store Yard at RAYANG and deposited, complete all as specified and as directed.
S&F Oil Safety Control (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up including Taking down/out Unserviceable Oil Safety Control, complete all as specified and as directed.
S&F Solenoid Switch Assembly (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up including Taking down/out Unservice-able Solenoid Switch Assembly, complete all as specified and as directed.
S&F Synthetic Insulation Mat of Size 2000x1000x12mm thick (as approved), ISI marked and suitable for 1100 Volts Grade including Taking out Unserviceable Insulation Mat of any description, complete all as specified and as directed.
S&F Toggle Switch 3-way, Double Pole (as per existing/ as approved) and connected including Taking down/out unserviceable Toggle Switch, complete all as specified and as directed.
S&F Water Safety Control (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up including Taking down/out Unservice-able Water Safety Control, complete all as specified and as directed.
S&F Water Temperature Gauge (as per existing/ as approved) for DG Set of any Capacity, Make, Type and connecting up including Taking down/out Unservice-able Water Temperature Gauge, complete all as specified and as directed.
M&L Cleaning of Radiator of any capacity after Opening all Nuts, Bolts, etc. by dismounting, Re-mounting after Cleaning with Chemical and Tightening of Nuts, Bolts, etc. including Straightening of Radiator Fins with suitable Tools, complete all as specified and as directed.
M&L Repairing & Cleaning of Diesel Tank with suitable Materials after disconnecting Fuel Line, Opening of all Nuts, Bolts, etc., Re-fixing the same after satisfactory Repairing including necessary Welding (if required), etc., complete all as specified and as directed.
M&L Rewinding of Alternator Coils of any Capacity using Proper Size, Double Paper covering with Super Enamel Copper Winding Wires with Proper Guage, conforming to IS:7404 (Part-I) : 1991 (as per existing Size, Turns and Insulation Class including Providing All Insulation Materials, Gasket, etc., suitable for 415 Volt Alternator and Testing, complete all as specified and as directed.
M&L Disconnecting all Electrical Cable Connection from the Dynamo Assembly and Taking down the Dynamo Assembly for Carry out Repairs and Complete Overhauling the System including Replacing the Unserviceable Parts like Carbon Bushes, Bearings, Armature, Burnt out coils, etc., Re-assambling & Re-fixing the Dynamo Assembly to Original Position and re-connecting all Electrical Cable Connections & Testing for DG Set 20 KVA to 50 KVA Capacity of Make : Ashok Leyland/ Kirloskar, complete all as specified and as directed.
Disconnecting & Dismounting of Self Starter 12 Volts from the Engine of DG Set 20 KVA to 30 KVA, Transporting to nearest Authorised Workshop for Repairing, Replacement of Unservicable Parts, Servicing Complete, Transporting the same from Workshop to Site of Work and Re-fixing with DG Set, Testing, complete all as specified and as directed.
Supply & Filling Coolant for Radiators as approved), complete all as specified and as directed. MAKE : KIRLOSKAR or as approved by GE
Supply & Filling Engine Oil 20 W/ 40 Grade as approved), complete all as specified and as directed. MAKE : CASTROL CRB PLUS or as approved by GE
M/s Singh enterprises
Vicky Construction
NChetia and Sons Trading
M/S R G Construction
FREEZCON
M/s PRABIR ENTERPRISE
M/S P R SINGH AND SONS
M/s HALDER ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .