Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC NO 9A VINAYAKANILAYA KANAKA GANAPATHI STREET OM SHAKTHI LAYOUT KANAKAGIRI HORAMAVU POST BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹35.1 L+₹2.4 L (7.42%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹36.4 L+₹3.8 L (11.5%)Rejected-Finance | L3 | Rejected-Finance Not L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
13 May 2021, 6:00 pmClosed
GARRISON ENGINEER CENTRAL BANGALORE
MILITARY ENGINEER SERVICES GARRISON ENGINEER CENTRAL AGRAM POST BANGALORE 560007
ADDL ALTN TO BUILDING NO ETA78, P86 AT ASC CENTRE AND COLLEGE, SPECIAL REPAIR TO BUILDING NO P11 P15 AT VOC AND GUARD ROOM AT ASC CENTRE NORTH UNDER GE CENTRAL BANGALORE
2021_MES_417345_3
8969/E8
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER CENTRAL BANGALORE
₹60,000
Yes
21 Jun 2021
15 Apr 2021
15 May 2021
15 Apr 2021
13 May 2021
29 Apr 2021
15 Apr 2021 - 28 Apr 2021
Amount
Demolition of plain cement concrete (unreinforced) any description and in any position not otherwise specifically provided for etc complete including removing the materials out side MD land complete all as specified and directed.
Demolition of reinforced cement concrete any description and in any position not otherwise specifically provided for etc cutting reinforcement steel to facilitate demolition of concrete including removing the materials out side MD land complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc and removing debris outside MD land complete all as specified and directed.
Taking down chowkats or frames, exceeding 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
Taking down chowkats or frames, exceeding 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposing serviceable tiles to MES store and the rubbish/debrises out side MD land complete all as specified and directed.
Dismantling timber boarding, any description, fixed in any position with nails complete all as specified and directed.
Dismantling timber scantlings 40 Sq.cm and over in section (unframed work), in any position complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing debris outside MD land complete all as specified and directed
M & L for surface excavation averaging 15cm deep and n.exc 30cm deep and getting out as in soft/loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in any type soil (ie mixer of soft/loose and hard/dense soil) complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Removing excavated material to a distance exc 250 metre and not exc. 500m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M & L for moorum/sand/red bajri filling under floors or in foundations laid in layers n exc 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M & L for ATT by treating the top surface of filled earth at the rate of 5.00 litres of emulsion per square metre of surface area.
M & L for ATT by treating the soil under plinth protection at the rate of 5.00 litres of emulsion per square metre of surface area.
M & L for ATT by treating the soil along wuth external perimeter of building at the rate of 2.50 litres of emulsion per metre of the perimeter wall. Make name ATT chemical for item No 17 to 19 :- DURSBAN/LETHAL/TRISUL
M & L for Hardcore of broken/crushed stone aggregate of gauge n.exc 63 mm deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for precast cement concrete block masonry type C1, 1:3:6 (20 mm graded granite stone aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M & L for Plain cement concrete 1:3:6, type C-1, (using 20 mm graded stone aggregate) as in coping, kneelers, bed plates etc including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for 75mm thick Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base of floor, etc complete all as specified and directed.
M & L for 40mm thick DPC to horizontal or vertical surfaces using PCC 1:2:4, type B-0 mixed with integral water proofing compound (WPC) @ 3% of cement weight including necessary form work complete all as directed. Note:- Integral water proofing compound shall be measured and paid separately in respective item.
M & L for Reinforced Cement Concrete M-25 design mix (Using 20mm graded stone aggregates) as in foundation, footings foundation beams, plinth beams etc complete all as specified and directed.
M & L for Reinforced Cement Concrete M-25 design mix (Using 20 mm graded stone aggregate) as in columns, pillars, piers, post and struts etc complete all as specified and directed.
M & L for Reinforced Cement Concrete M-25 design mix (Using 20 mm graded stone aggregate) as in beams, cantilevers, lintel beam etc complete all as specified and directed.
M & L for Reinforced Cement Concrete M-25 design mix (Using 20 mm graded stone aggregate) as in slabs supported on walls, beams and column in floors, roofs, landings, balconies and in shelves and the like complete all as specified and directed.
M & L for Reinforced Cement Concrete M-25 design mix (Using 20 mm graded stone aggregate) as in chajjas etc complete all as specified and directed.
M & L for use & waste Form work to sides of concrete foundations, footings, raft beams, sides and soffits of plinth beams and the similar works for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to sides of concrete columns, pillars, piers, post and struts and the similar works for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings, balconies and in shelves and the like for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to sides of concrete chajjas and the similar works for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to soffits and sides of beams, lintel beam for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to sides/edges of concrete flats, floor and roofs, in walls, horizontal or slopeing and the similar work, 10cm to 20cm wide for rough finished surfaces of concrete complete all as specified and directed.
S & F TMT steel bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F TMT steel bars 6 to 10mm dia, cut to length, bend to shape required, including cranking, bending spirally as in tie/stirrups of columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F TMT steel bars 6 to 10mm dia, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Cutting/chipping the spalling concrete surfaces of columns, beams, facias, slab, chajjas & cantilevers etc and trimming cleaning the surfaces of any thickness all as specified and directed and Matrial & Labour for applying epoxy treatment for bonding old demolished concrete surfaces including application of one coat of notozinc primer to the exposed reinforcement and over plastering in CM 1:4 average 20mm thick finished even and smooth without using extra cement to level the surface etc including necessary scafolding as required at site and where required complete all as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, dirt etc and brushing neat cement slurry with 3 kg of cement per sqm on floor complete all as specified and directed.
S & F box type powder coated steel windows/ventilators double side shutters ie glass and wire mesh shutter, including pressed steel frames made out of CRCA sheet of 80X60X1.25mm thick double rebated, shutters box type made out of CRCA sheet of 40X20X1.0mm thick, 12mm square guard bar/grill welded to steel frame, window shutters side hung, ventilator shutters top hung, box type hinges, aluminium die cast handles for glass shutters, iron flat type handles for mesh shutters, telescopic stays etc complete all as specified in TD drawing No TD/539 dated 09.02.2004 of Chief Engineer Chennai Zone and as directed. NOTE:- (i) Qouted rate under this item shall deemed to be inclusive of steel frame, both side steel shutters, guard bars/grills, handles, stays, beading/fillets for fixing glass/wire mesh including cost elements for fixing of glass & wire mesh and mearurement/ pament shall be considered as one unit by comprising all these elements. (ii) Glass and wire mesh shall be measured and paid as supply only underseparately under respective item.
S & F Steel ventilator top hung fixed type shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples including timber bead complete all as specified and directed.
S & F solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet 5mm thick to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification and drawing and as directed.
S & F second class hard wood scantling, clean sawn timber fixed with nails etc complete all as specified and directed.
S & F well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints including treating the timber libarally brushed at least twice with oil or kerosene based solusion of chlorophyrifos 20EC 1.0 % (by weight) concentration complete all as specified and as directed.
M&L for 35 mm thick 2nd class hard wood factory made glazed/gauzed skeleton shutters for door, open rebated and prepared to receive glass, gauze etc (without sash bars), edges framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc; size of the members of shutters as specified in SSR Part- I, Section 8, clause 8.24(a) complete all as directed.
S&F 30mm thick Flush shutters, solid core construction, with block coard core & plywood face panels commercial type on both side conforming to IS 2202 (Part- I) -1999, including internal liping beading all round fixed as in Door Shutter,Cup board shutter & Kitchen rack all as specified.
S & F 20 mm thick, second class hard wood boarding, clean sawn, planed one side with butt joints and fixed with nails in any situation as in eaves board, etc complete all as specified and directed.
S & F 5.5 mm thick, sheet glass, ordinary quality and glazing with oil putty/timber beads in square exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S & F 4 mm thick, sheet glass, ordinary quality and glazing with oil putty/timber beads in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S & F 4 mm thick, sheet glass, figured/ pin headed glass and glazing with oil putty/timber beads in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed
S & F 100 mm size, butt hinges, stainless steel with cadmium coated screws complete all as specified and directed.
S & F 100 mm size, butt hinges, medium weight, cold rolled complete all as specified, and directed.
S & F 150 mm long, Aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic film complete all as specified and directed.
S & F 125 mm size, Aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and directed.
S & F aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm anodised finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and directed.
S & F aluminium anodised coloured powder coated (minimum thickness of powder coating 50 micron) frame for doors, windows and ventilators with one or more rebates including jointing cleats for fixing etc complete all as directed.
S&F aluminium anodised coloured powder coated (minimum thickness of powder coating 50 micron) fixed/sliding type window/ventilators, aluminium sections weighing not less than 0.55kg per metre, all are made of from aluminium anodised section including necessary track, jointing cleat, glazing clips, rubber packing anodised aluminium snap beading, screws of suitable size and stainless steel wire cloth, locking arrangement, etc complete all as specified and directed by the Engr-in-Charge.
S & F aluminium anodised coloured powder coated (minimum thickness of powder coating 50 micron) door shutter side hung type with style rails (Top, Bottom & lock rail) Top rail meeting style, lock rail of size 48 x 44mm, bottom rail size 108 x 44mm, all are made from anodised aluminium section including necessary jointing cleat, glazing clips, rubber packing, anodised aluminium snap beading, screws of suitable size& two numbers aluminium anodised handle of suitable size, etc complete all as specified and directed (Note : Thickness of aluminium section shall not be less than 1.5 mm).
S & F aluminium Anodised snap grid (powder coated) frame work of size 600mm x 600mm frame work for ceiling with aluminium tee section of size 28.6mm x 24.0mm x 1.4mm thick, aluminium angle section of size 19mm x 19mm x 1.4mm thick and aluminium main runner section of size 38mm x 24mm x 1.4mm thick, for false ceiling suspended by and including providing hangers 4 mm dia. G.I. wire (upto 1200mm length centre to centre) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frame including providing two coats of white wash complete all as specified and directed by the Engr-in-Charge. Make of E-Board :- Eternit Everest / lafarge/ Armstrong or equivalent as approved by GE
M & L for Plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) as in coping, kneelers, bed plates etc including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and directed.
M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in base of flooring, in roof etc and finished the surface fair to receive top layer screed bed complete all as specified and directed.
M & L for 40 mm thick, plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in floors laid in panels, finishing the surfaces even & smooth with using extra cement complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles, Grade B II(a), 7 to 8mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles, Grade B II(a), 7 to 8mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for glazed ceramic, coloured tiles, Grade B III, 7 to 8 mm thick area of each tiles not less than 0.06 sqm as in skirting/dado/vertical surfaces including 10 mm thick screed bed in cement mortar 1:3 set & jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles, Grade B II(a), 8 to 10mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.36 sqm, in floors etc, including 15 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for ceramic, coloured tiles 8 to 10 mm thick as in skirting/dado/vertical surfaces to match the length of floor tile procured under No 71 above including 10 mm thick screed bed in cement mortar 1:3 set & jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for precast chequered cement concrete tiles of size 30cm x 30cm x 20mm thick, as in floors etc, including 15 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and directed.
M & L for cutting hole in stone/brick wall built in cement mortar for insertion of hold fast including making good dismantled portion by using plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) and plastering, finishing the surfaces to match with existing etc complete including necessary form work all as specified and directed.
S & F Mild steel small articles using flat iron such as band, strap, hold fast, cleat, support, hook, hinges, base tie for door frame etc and other similar items conforming to Fe-290, Gde E-165 including retaining with tar or coat tar black paint complete all as specified and as directed.
M&L for 18/19mm thick Prelaminated particle board, exterior grade, prelaminated one sides with decorative choice lamination and other side balancing white lamination and 3mm thick teak wood beading/edging fixed with invisible screws to timber frame work, complete, as specified and directed
M & L for providing brick work in Cement Mortar 1:6 , 23 mm thick and 15cm high along external walls to fill the gap between roof sheet and existing wall top including rendering in 15mm thick using 1:6 cement mortar finished even and smooth without using extra cement and white wash complete all as directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection laid in proper slope/gradient etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
M & L for Plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in benching including finished the top surfaces even and smooth using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 10 mm thick in cement mortar 1:6 on other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two layer (10mm + 5mm thick) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with water proofing compound at top 5mm thick layer by weight of cement as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
M & L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces as in ceiling and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for preparing surfaces of wood and wood based materials, new or old of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and directed.
M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M & L for Preparation of old surfaces walls and applying two coats of white wash complete as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of primer including 1 to 2mm thick wall care putty complete all as specified and directed.
M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
"Supply only" liquid water proofing compound complete all as specified and directed. (Make : Dr FIXIT/Fosroc/choksey)
M&L for 10 mm thick rendering in Cement Mortar 1:4 finished fair and even without using extra cement using water proofing compound @ 2% by weight of cement over and Applying oil bound bitumen primer @ 0.20 kg/sqm and providing 3mm thick APP modified water proofing membrane weighting not less than 3.6 kg/sqm reinforced with non woven polyester matt weighing not less than 160 gm/sqm having softening point not less than 150mm centigrade, having tensile strength of 650 N/sqcm and 350 N/sqcm in longitudinal and transverse directions respectively of the reinforced tearing strength of 180N by torch application with minimum 10cm side overlapping and 15cm end lap, applying a coat of blown grade hot bitumen 90/15 over the mebrance @ 1.2 kg/sqm top of membrane surface shall then be finished with solar reflective bituminous aluminium paint @ 0.10 kg/sqm complete all as per manufacturer instructions and as directed by Engineer-in-Charge over roof and wall surfaces.
M & L for precast cement concrete tiles 25X25X20mm thick with grey cement and no pigment, machine pressed laid over 15mm thick screed bed in CM 1:6 set jointed and pointed in neat cement slurry in floors grouted flush in cement mortar 1:3 complete all as specified and directed.
Supply and fixing precast RCC pipe, 150mm bore, class NP-2, conforming to IS 458:2003, laid and jointed complete all as directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggragate) as in bed to drain pipes including packing under and against the sides of pipes after they are laid and tested complete for 150 mm bore RCC drain pipes complete all as specified and directed.
Cutting into existing manholes for inserting new drain pipe, 150mm bore and making good to pipe and rendering, cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B1 finished to match with existing complete all as directed.
Dismantling of rotational moulded polyethylene water tank of capacity exceeding 500 Litres but not exceeding 1000 Ltrs.
S&F rotational moulded polyethylene water storage tanks 1000 litre capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia brass ball/float valve high pressure with polythene float and flynut, 20 mm water tank nipple suitable for HDPE water tank, 20mm bore gun metal gate/globe valve with iron wheel head complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks 500 litre capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia brass ball/float valve high pressure with polythene float and flynut, 20 mm water tank nipple suitable for HDPE water tank, 20mm bore gun metal gate/globe valve with iron wheel head complete all as specified and directed.
Taking up or down 20mm bore, Steel tubing and connections.
Supplying and laying of 20mm dia CPVC pipes (ISI marked) SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supplying and laying of 25mm dia CPVC pipes (ISI marked) SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
M & L for taking branch connection from existing distribution GI pipe line of bore 25mm including cutting, threading, inserting GI fittings ie socket, nipple, union and unequal size Tee to take branch connection of 25/20 mm bore all as directed by the Eng-in-charge.
Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixtures complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
Supply, laying, connection and testing, 20mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixtures complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
Supply, laying, connection and testing, 20mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixtures complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
S&F Vitreous China Squatting Pan"Orissa pattern" size 580 mmx440 mm white with integral foot rest S or P trap etc. including 10 ltr capacity low level PVC Flushing cistern, PVC connection pipe, 15 mm dia, 600 mm long and 32mm dia flush pipe, S or P Trap & Provision of concrete bedding and making good to floor all as specified & directed by Engineer-in-charge.
S & F Vitreous China urinal, half stall type, white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe & waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and directed. (Make: PRAYAG Cat No. 4998 or equivelant of make Hindware/Cera/Parryware)
S&F Vitreous China Wash hand basin , white flat back size 550x400 mm including a pair of mild steel angle iron brackets duly painted, erected/embeded in wall, 32 mm waste coupling brass chromium plated suitable for wash hand basins & 32 mm dia LDPE PVC waste pipe, PVC connection 15 mm size 450 mm long including cutting hole and pinning in ends making good disturbed portion using cement mortar 1:3 complete all as specified & directed by Engineer-in-charge.
S&F in repair Vitreous China Wash hand basin , white flat back size 550x400 mm including a pair of mild steel angle iron brackets duly painted, erected/embeded in wall, 32 mm waste coupling brass chromium plated suitable for wash hand basins & 32 mm dia LDPE PVC waste pipe, PVC connection 15 mm size 450 mm long including cutting hole and pinning in ends making good disturbed portion using cement mortar 1:3 complete all as specified & directed by Engineer-in-charge.
S & F in repairs, vitreous China wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe with white PVC seat and cover closed pattern with recessed bottom complete but excluding flushing cistern & flush pipe including making good damaged/disturbed surfaces complete all as specified and directed.
S & F in repairs, 10 litre capacity, PVC valve less syphonic action type, 32mm dia flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle brackets complete all as specified and directed. Make CERA Cat No B1010109 or equivelent of PRAYAG/HINDWARE/Parryware
S & F in repairs PVC connection pipe with PTMT nuts, 450mm long. Make: CERA/Hindware/Parryware/PRAYAG
S&F pillar taps, brass, with capston heads, fancy type, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed in repair, complete all as specified and directed. Make PRAYAG Cat No 7202 or equivelent of CERA/PARRYWARE/HINDWARE as approved by GE.
S&F in repair pillar taps, brass, with capston heads, fancy type, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed in repair, complete all as specified and directed. Make PRAYAG Cat No 7202 or equivelent of CERA/PARRYWARE/HINDWARE as approved by GE.
S&F in repair 20 mm Gun metal globe or gate valves,with iron wheel head,screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 25 mm Gun metal globe or gate valves,with iron wheel head,screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F 15 mm bore, bib taps, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. Make PRAYAG Cat No 7306 or equivalent as approved by GE
S & F 15 mm bore, concealed stop valves, fancy type with flange and shank, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. Make PRAYAG Cat No 6518/6718 or equivalent as approved by GE
S & F 15 mm bore, stop valves/angle valve, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. Make PRAYAG Cat No 7310/7328 or equivalent as approved by GE
S&F 125 mm size Brass chromium plated shower roses with swivel joints, including fixing to steel pipe or union complete, fixed in repair,all as specified and directed. Make CERA Cat No F7020302CH or equivelent of PRAYAG/PARRYWARE/HINDWARE as approved by GE
S & F towel rail, 600 mm long of PTMT fixed with and including chromium plated brass screws in wooden/plastic cleat or rawl plug complete all as directed. (Minimum weight 190 gms). Make PRAYAG Cat No 200 or equivalent as approved by GE.
S & F in repairs brass chromium plated tubular towel rail, 20mm dia 'D' type, 600mm long between flanges complete all as specified and directed.
S & F in repairs health faucet brass chromium plated with 1 metre long flexible steel pipe with PVC lining suitable for 15mm bore pipe complete all as specified and directed. Make CERA Cat No F8030106AB or eqivalent as approved by GE.
S & F brass chromium plated soap dish, fixed with chromium plated brass screws complete as specified and directed. (Make: Cera Cat No F5003106 or eqivelent of Parryware /Hindware as approved by GE)
S&F in repair 110 mm dia UPVC (SWR) pipes, Type 'B', single socketed,in any length with rubber ring joints,laid in trenches or in floors complete all as specified and directed.
S&F in repair 75 mm dia UPVC (SWR) pipes, Type 'B', single socketed,in any length with rubber ring joints,laid in trenches or in floors complete all as specified and directed.
S & F 110 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length without ears, with solvent cement joints fixed to wall using MS holder bat, etc complete all as specified and directed.
S & F 75 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length without ears, with solvent cement joints fixed to wall, using MS holder bat etc complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) bends of any radius with acess door complete all as specified and directed.
S & F 75 mm bore, PVC (SWR) bends of any radius with acess door complete all as specified and directed.
S&F UPVC (SWR) junction single,(single T) 110 mm with access door complete all as specified and directed.
S&F UPVC (SWR) junction single,(single T) 75 mm with access door complete all as specified and directed.
S&F UPVC (SWR) branch piece, single,(single Y) 110 mm with access door complete all as specified and directed.
S&F UPVC (SWR) branch piece, single,(single Y) 75 mm with access door complete all as specified and directed.
S & F 75 mm dia outlet , PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S & F in repair 75 mm dia outlet , PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M & L for Point wiring surface type, with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including providing PVC casing caping/conduit 'medium grade' with all fittings and accessories (like Tee, bend etc.) complete in walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point and earth dolly including MS/PVC terminal box with 3mm thick masonite laminated sheet top cover fixed on wall with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed.
All as per item No 142 above but for one 3 pin socket outlet, 5 Amps on Independent board complete all as specified and directed.
All as per item No 142 above but for one 5 Amps, 3/5 pin socket outlet on the same board with other switches complete all as specified and directed.
All as per item No. 142 here in before but wiring with cables of size 2.50 sqmm for wiring & cables of size 2.50 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 6 pin Switch/Socket outlet on Independent board complete all as specified and directed.
S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed.
S & F Switch socket combination, 2 in 1, 5 Amps (bearing ISI marked), flush type, 240 volts complete all as specified and directed.
S & F Switch socket combination, 5 in 1, 5/15 Amps (bearing ISI marked), 240 volts, flush type complete all as specified and directed.
S & F bell push button, flush type, single pole, 240 volts, one way complete all as specified and directed.
S & F buzzer/calling bell, Ding Dong type, AC 230 volts, single pole complete all as directed.
S & F Ceiling rose, 3 phase/PVC/polycarbonate (bearing ISI marked), isolated body including providing PVC square/round block complete all as specified and directed.
S & F Factory made distribution board (DB), in sheet steel enclosure without bus bar, 2 way, 240 Volts IP-43, IK -09, suitable for housing MCB's complete all as specified and directed.
S & F MCB, SPN, 240 Volts, 6 Amps, 'C' Series, 10KA breaking capacity complete all as specified and directed.
Supply and fix LED tube light fitting of 10/09 watts, 230 volts, with long lasting aluminium body with slim & sleek looks all per-wired fixed on walls with all fixing acessories such as 02 Nos of PVC square/round block/boxes, screws etc and connecting up with three core flexible copper conductor cable of size 24/.20 sqmm complete all as specified and directed. Make : Havells Cat No LUMILINEBS9WLED865SPCWH or equivelent of Philips/Crompton Greaves/Bajaj
S&F LED tube light fitting of 20 watts 6000K , 230 volt, basic all purpose surface and wall mounted type with polycarbonate housing & integrated electronic driver complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and providing & connecting up with twin core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Havells Cat No LUMILINEBS20WLED830SPCWH or equivelent of Philips/Crompton Greaves/Bajaj
S&F energy saving environmental friendly long life, with high power LED building security light 1x 25 Watt LED pressure die-cast aluminium, heat resistant, toughened glass diffuser, IP65/66 and wired with all accessories and including bracket made out of 40 mm bore GI pipe 'Light grade', 1.50 M long made to required shape, fixed to wall and connection up with 3 core flexible copper conductor cable 4/20 mm size, 1.5m long and testing on installation all as specified and directed. Make: Havell's Cat No. ENDURAPEARLSL25WLED757SASYTOPC or equivelant of make
M & L Earthing complete with Galvanised steel earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete inclduing taking down old one as specified and as directed.
Supply and Fixing exhaust fan, 300mm sweep metal body, AC single phase 230/240 Volt including bird free louver shutter cut to fit with hole for exhaust fan including providing holes grouting bolts and 3 core flexible copper conductor cable of size 24/0.20 sqmm connecting up from ceiling rose to exhaust fan terminal complete all as directed. Make Havells/Crompton/Orient/Bajaj
Supply and Fixing water heater/gyeser, storage vertical type, any colour, 25 Litre capacity, BEE 5 star rated including suitable high pressure heavy duty braided PVC connection pipes 15mm dia 600mm long for hot and cold water making neccessary electrical connection & testing on completion complete all as directed. Make : HAVELLS, model No: MONZA EC or equivelent of make Bajaj/CG/VENUS
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI wire armoured cable for working voltage 1100 volts, 4 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, working voltage upto 1100 Volts, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply and laying well kiln burnt bricks, locally available best quality bricks laid breath wise across the length of cable over sand cushioning in trenches for protection of UG cables complete all as specified and directed.
M & L for Sand cushioning and covering with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment. Consolidated thickness shall not be less than 18cm)
Supply, laying, 40mm bore, Steel water tubing, galvanised, light grade with all fittings and fixtures for cable protection on road/drain/floor or for hangging ceiling fan etc including providing MS clamp, bolt, nuts complete all as specified and directed.
SHREE BANASHANKARI ASSOCIATES
Srisrinivasaenterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .