Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.2 CrAccepted-AOC | ₹8.2 Cr | 1 | Accepted-AOC Being L1 |
| 2 | 2₹8.4 Cr+₹15.9 L (1.93%)Rejected-Finance | ₹8.4 Cr+₹15.9 L (1.93%) | 2 | Rejected-Finance Since not L1 |
| 3 | 3₹8.5 Cr+₹23.0 L (2.79%)Rejected-Finance | ₹8.5 Cr+₹23.0 L (2.79%) | 3 | Rejected-Finance Since not L1 |
| 4 | 4₹8.8 Cr+₹55.6 L (6.76%)Rejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹8.8 Cr+₹55.6 L (6.76%) | 4 | Rejected-Finance Since not L1 |
| 5 | 5₹9.0 Cr+₹75.4 L (9.16%)Rejected-Finance | ₹9.0 Cr+₹75.4 L (9.16%) | 5 | Rejected-Finance Since not L1 |
Tender Value
₹7.5 Cr
EMD Value
₹7 L
Closing Date
21 Aug 2023, 6:00 pmClosed
Chief Engineer RnD Secunderabad
Chief Engineer RnD Picket Secunderabad 500003
UPGRADATION OF LAKSHYA HANGAR AND RENOVATION OF STRUCTURES HANGAR FOR STRUCTURAL TESTING OF AIRFRAMES AT ADE BANGALORE
2023_MES_596854_2
82629
Open Tender
Civil Works
Item Rate
365 days
ADE Bangalore
Class A
Category a i
8 documents required · 8 mandatory
₹3,000
Yes
Garrison Engineer I RnD East Bangalore
₹7 L
Yes
7 Feb 2024
3 Aug 2023
28 Aug 2023
3 Aug 2023
21 Aug 2023
14 Aug 2023
Amount
Demolition of brick work or stone boulder masonry built in cement mortar/ lime mortar complete all as specified and directed.
M&L for 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete set in CM 1:6, complete all as specified and directed.
M&L for taking down and refixing of old stainless steel railing including necessary welding and fixing hold fasts complete all as specified and directed.
Dismantling of Aluminium frame work as in partitions and like including taking out boarding / glass etc., complete all as specified and directed.
M&L for RCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in precast cement concrete in landings, cover slabs (for RCC shelf, manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete all as specified and directed.
Formwork to faces of staircase railings and similar works like walls, retaining walls, abutments, parapets including attached pillasters, buttresses, etc.; vertical or to better complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement plaster 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in two coat (first 10mm & Second 5mm thick) in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Demolition of PCC (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of PCC (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out as in hard / dense soil complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in cement concrete in foundations, filling and mass-concrete complete all as specified and directed.
M&L for RCC M-25 (design Mix) as in walls, retaining walls, basement walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed.
M&L for RCC cast in situ B0 1:2:4 (12.5mm graded aggregate) walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed.
M&L for RCC cast in situ B0 1:2:4 (12.5mm graded aggregate) slabs, supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like; complete all as specified and directed.
Hardcore of gauge exc 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled / rammed to a true surface complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 type B2 using 40 mm graded crushed stone aggregate as in hard lean concrete below proposed strong floor and epoxy floor complete all as specified and directed.
M&L for RCC M-40 ( Design Mix) as in foundations, including rafts, footings, in sub base of strong floor foundation beams; plinth beams; bases for columns etc, basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
Supply only, metal fiber (steel fiber) for mixing in RCC for strong floor complete all as specified and directed. Note: Steel fiber to be supplied by authorised manufacturer / dealer.
M&L for upto 5mm thick self levelling chemical / concrete for levelling of layer of RCC / PCC in floor complete all as specified and directed by Engineer-in-Charge or as per manufacture's instructions. Note: Levelling / evenness of floor shall be maintained within (+) (-) 1mm. Make: FOSROC or equivalent.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. with riveted, bolted or welded attachment complete all as specified and directed.
M&L for joist channel, ISMC channel, angle or tee section, fixed in strong floor independently without connection plate Fe410-W (Gde E-250) Quality B (cut to ordinary length i.e, within 20mm of the length indicated) including necessary drilling in ISMC to hold anchor bolt passing through 20mm MS plates and necessary welding of small steel bar pieces at the interface of ISMC & micro concrete and all as shown in drawings of strong floor.
S&F, rolled section as in crane gantries, rails and fastenings and heavy bracket fraing of Fe 410-W (Gde E-250) quality B (Beam tee, angle channel or flat section including distance pieces cleats etc) complete all as specified and directed. Note: Item will be provided by crane vendor depending on design of crane.
MICRO CONCRETE GROUTING BETWEEN ISMC: M&L for providing and laying ready to use cement based repair concrete (microconcrete) in thickness as per directed at site / user requirement (technically) / engineer incharge in the designated area to the prepared slurry tight shuttering with proper shear connector and bonding agent where ever necessary. The material shall be high strength and shall have non shrink properties. Microconcrete shall be ready to use and be mixed with water with water / powder ratio as specified by manufacturer to achieve the following parameters:- Compressive strength One day Strength >= 25 N/mm2 Compressive strength 28 days Strength >= 65 N/mm2 Flexture Strength 28 days 5 N/mm2 The mixed density of microconcrete shall be >= 2000 kg/m3 at 27C. Make: SikaRep microcrete 4 / Fosroc Rendroc RG / BASF Emaco S 346.
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to better complete all as specified and directed.
M&L for sand (CNS) filling at back of wall pit including watering, well ramming complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (20 mm graded stone aggregate), 100 mm thick as in hard standing top surface finished by Vaccume Dewatered Floors process (VDF) i.e top surface vibrated with poker vibrator, then screed vibrator is run over the surface, supported on channel shuttering spaced @ 4.00 meters apart, screeed vibrator is run twice to achieve optimum compaction & levelling after this system of lower mats & top mat is laid on the green concrete and this is attached to a vaccum pump which draws out excess water etc complete all as specified and directed.
M&L for plates (plain or chequered) channels square cut or notched (ordinary and counter sunk) forming holes, welding with each other in strong floor and fixing anchor bolt by making holes in plates complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in hard/dense soil complete all as specified and directed.
All as per Sl item No. 32 above, but depth exc 1.50m but not exc 3m depth.
All as per Sl item No. 32 above, but depth exc 3m but not exc 4.5m.
M&L for PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) as in cement concrete in foundations, filling and mass-concrete complete all as specified and directed.
Brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed.
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC / PCC bands in walls, horizontal or sloping and similar work all exceeding 20cm wide (where RCC / PCC band in walls, spanning and opening, the formwork soffit only shall be finished surface concrete complete all as specified and directed.
M&L for preparing new steel surface of any description, exceeding 10 cm width or girth, not other wise described over and applying two coat of synthetic enamel paint over already shop coated surfaces complete all as specified and directed.
M&L for preparing old surfaces of steel surface of any description, exceeding 10 cm width or girth, not other wise described oveand applying one coat of synthetic enamal paint, complete all as specified and directed.
M&L for preparation of plastered or unplastered of un decorated surface of walls, chajja, balcony, facia etc by brooming down or steel wire brushing, scrapping down smoke soots, moulds, moss, efflorescent salts, treading oil and greasy spots, and applying two coat of interior dust proof plastic emulsion paint over and including a coat of priming paint over 2 mm wall care putty including sand papering to obtain smooth finish complete all as specified and directed. Make: Royal in Asian or its equivalent in Berger / Johnson / Nicholson.
All as per Sl item No. 42 above, but on old surfaces after and including complete removal of existing treatment of any type and condition complete all as directed
M&L for preparing new plastered surfaces including two coat of exterior plastic emulsion paint over a coat of primer complete all as specified and directed.
M&L for preparation of old wall surfaces by complete removal of existing treatment, preparing wall surfaces and applying one coat of exterior plastic emulsion paint complete all as specified and directed.
M&L for 2mm thick epoxy resin based floor topping after priming the surface solvent base epoxy resin primer designed for maximum absorption and adhesion as per manufacture specification including preparation of floor by wire brushing or light grit blasting to remove laitance, dust and cleaning the same to achieve mechanical key between the floor and coating system and applying epoxy putty mixed with suitable fillers to cover the worn out areas complete all as specified and directed. Note: (a) Floor topping shall be Nitoflor SL 2000 of M/s FOSROC / MASTERTOP TM 1215 PLUS of BASF or equivalent in CIPY. (b) Primer shall be Nitoprime 25 of M/s FOSROC or equivalent in BASF / CIPY. (c) Epoxy putty shall be Nitoflor FC 140/150 of M/s FOSROC or equivalent in BASF / CIPY.
S&F, providing readymade cable duct with MS pre coated 2.5 mm thick 300 x 300 mm with top cover finished with paint complete all as specified and directed.
M&L for 75mm thick PCC 1:2:4 type C2 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
M&L for 30 mm thick PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in floor concrete as base for laying tiled surface complete all as specified and directed.
M&L for double charged vitrified ceramic tiles 9-10mm thick (square / rectangular) area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed in CM 1:6 complete all as specified and directed. Make: Kajaria / Somany / Johnson.
All as per Sl item No. 50 above, but on vertical surface with 10mm screed plaster in CM 1:4 as in skirting complete all as specified and directed
Non Skid Ceramic tiles 7-8mm thick (square / rectangular) area of each tile not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed in CM 1:6 complete all as specified and directed.
All as per Sl item No. 52 above, but on vertical surface as in dado including 10 mm thick screed plaster in CM 1:4 complete all as specified and directed .
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welding complete all as specified and directed.
All as per Sl item No. 54 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
S&F, high strength friction grip bolts with 8.8 grade hexagonal / round bolts, hot-dipped galvanised (Grade 8.8) upto M-20, length upto 900mm and as directed by Engineer-in-Charge or as specified in drawings.
Taking down chowkats or frames with shutters without taking off shutters from frame not exc. 1.5 sq. m each complete all as specified and directed.
Taking down Shutters of any description exc 1 and not exc 2 sqm each complete all as specified and directed.
S&F, 40 mm thick flush shutters, solid core construction, with particle board core and decorative face both sides complete all as specified and directed.
M&L for Factory made solid panel pace door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of but wood grain printed PVC sheet used instead of Plain colour PVC sheet & 5mm thick x 15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (90deg) used instead of exposed portion of PVC sheet beading complete all as specified and directed.
S&F, Solid PVC Door Frame of size 50mm x 47mm made out of 5mm but wood grain printed PVC sheet used instead of Plain colour PVC Sheet & edges will be painted to match with printed sheett reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.
S&F, 100 mm butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11 complete all as specified and directed.
S&F, 125mm brass handles, cast type, polished bright complete all as specified and directed.
S&F, 150 mm brass barrel tower bolts, extruded section barrel and rolled or cast bolts and fixed complete all as specified and directed.
S&F, 300 mm brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled of drawn brass bolts and fixed complete all as specified and directed.
S&F, vitreous china wash down water closet pan (pedestal pattern) white, (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed.
S&F in repair PVC low level flushing cistern of cap 10 ltrs including PVC flush pipe for squatting pan fixed to wall ISI marked completed with brackets and accessories and making good to disturbed portion complete matching with existing surface and making GI pipe connection low level complete all as specified and directed.
S&F, plastic water closet seat, white, closed pattern, with flat bottom and cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed.
S&F in repairs Vitreous China Urinal, half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
S&F in repairs vitreous china urinal partition white of size 310 x 700 mm complete all as specified and directed.
S&F in repairs vitreous china wash hand basin (Pedestal type) white flat back of size 550 x 400 mm including bracket, cutting for and pinning the ends of brackets or erecting stands exclusive of waste pipe but including brass chromium plated waste coupling with long screwed sank and fly nuts including cost of pedestal complete all as specified and directed.
S&F in repairs pillar tap fancy swan neck type cast copper alloy, with capstan head chromium plated, screwed down high pressure, with or without letter 'Hot' or cold with long screwed shanks and fly nut screwed for iron pipe of bore 15mm, complete all as specified and directed. (weight of pillar tap shall not be less than 665 gms)
S&F in repair 450mm long PVC connection with PTMT check nuts for 15mm bore pipes of approved quality complete all as specified and directed.
S&F, Brass chromium plated tubular towel rail, 20mm dia, D type, 60 cm long between flanges, fixed in repair complete all as specified and directed.
S&F in repair toilet paper holder chromium plated fixed to wall with chromiuim plated brass screws complete all as specified and directed.
S&F in repair angle cock fancy type chromium plated 15mm bore complete all as specified and directed. Make: Prayag / Parryware / Jaquor.
S&F, urinal spreader of PTMT any colour for fixing with 15mm dia pipe (Minimum weight 60gms) complete all as specified and directed.
S&F in repairs CP health Faucets (1m tube & Hook) Prayag Cat Part No. BEA-81 or equivalent complete all as specified and directed.
S&F, 15mm CP bib tap two way for fixing health faucet complete all as specified and directed.
S&F, Grating doom 125 mm dia with waste hole of CP heavy weight square or round complete all as specified and directed.
S&F, 40mm High Density Poythelyne (HDPE) pipes of pressure rating 6kgf/sqm complete all as specified and directed.
S&F, conclussive push button taps of cast copper alloy, screwed for iron pipe and fixed complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.
M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed.
M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering / cladding to wall, roof with curved shape fixed with self tapping screws complete all as specified and directed.
Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in complete all as specified and directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in near cement slurry in floors including 20mm thick screed in CM 1:6 complete all as specified and directed.
M&L for provision of steel rolling shutters of size 3.3 x 4.2 mtr max size, lath thickness minimum 0.8 mm thick, motorised operated as well as manual operated type (out side wall fixing) including M&L for suitable capacity of motar, panel board, cable for the same, all connected items required for operation of the shutter in finished shape upto the satisfaction of Engineer-in-Charge including painting of the same complete all as specified and directed.
S&F, toughened glass of 12 mm thick as in doors including stainless steel top and bottom hinging arrangement complete, handle(s), all connected items including itching / design / writing letters on the door complete all as specified and directed.
S&F, powder coated aluminium frame and/or shutter for doors and windows of any section and type, ventilators, partition / work station cubicles etc., with one or more rebates including joining cleat, rubber beading for fixing, star or suitable lock etc complete all as specified and directed.
S&F, heat absorbing glass of 4 mm thick of any size complete all as specified and directed.
S&F, venetian blinds, vertical type, 100 mm slot width of approved fabric and powder coated aluminium top railsetc complete all as specified, including dismantlilng old damaged one complete all as specified and directed. Note: The colour, design and shade shall be as approved by GE.
Providing & fixing in true horizontal level 600mm x 600mm false ceiling system manufactured by M/s Armstrong World Industries using hot dipped galvanised steel section, exposed surface with pre-coated capping, main tee of size 15 x 32mm having 0.27mm gauge at every 1200mm centre to centre maximum and rotary stitched cross tee of size 15 x 32mm having 0.27mm gauge at every 600mm c/c and sub cross tee of size 15 x 32mm having 0.25mm gauge at 1200mm c/c and wall angle of size 19 x 19mm having 0.35mm gauge fixed to the periphery of the wall. The above grid is suspended at every 1200mm c/c in both directions using 2.0mm thick prestraightened GI wire laying FINE FISSURED MICROLOOK edge ceiling tiles manufactured by M/s Armstrong World Industries of size 600mm x 600mm x 12mm having NRC 0.55, light reflectance of >84% (WT), thermal conductivity k = 0.052-0.057 W/m0K, humidity resistance of 99% having fire performance CLASS 0 / CLASS 1 (BS 476), surface having 3 coats of white paint with fine fissured, back of the tile duly sanded and finished with a coat of protective paint over teh formed grid complete all as specified and directed.
S&F, Aluminium extruded section door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed complete all as specified and directed.
Dismantling structural steel work including doors, gates, stairways but excluding framed truss etc., complete all as specified and directed.
S&F, Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; will ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe410-0 or Fe 310-0, complete all as specified and directed.
All as per Sl item No. 96 above, but fabrication and fixing only after made it shaped with old steel obtained from dismatling existing bracings etc.
M&L for including dismantling valley gutter made up of 1.25 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 at a height of 12 mtr as in hangar including necessary scafolding, welding / soldering complete all as specified and directed.
Cutting out concrete blocks, slabs, brickwork or stone, masonry (in alternate course), forming toothings for and bonding new work in mortar into old work, including new materials entering old wall complete all as specified and directed.
S&F, marble stone of size not exceeding 1.5 sqm each including fixed on wall (bull nosed finish) with drilling hole for and including fixing bolts / borders if required and nuts complete all as specified and directed.
S&F for Stainless steel lettering comprising of alphabets, numarics, etc., of size upto 250 mm (proportional) fixed on marble / white granite stone complete all as specified and directed. Note: Each letter / alphbet couted and paid.
S&F for Floor display panel (of size 5 ft x 6 ft each) showing each floor diagram on PVC / acrylic sheet and box case with frame complete including fixing in position complete all as directed by user / EIC.
S&F, 2000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I.
S&F, SS wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples as in exhaust fan location complete all as specified and directed with aluminium frame guide complete all as specified and directed.
S&F, cast iron 100 mm floor trap, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
S&F, 4 mm thick sheet glass, obscured or frosted quality and glazing with oil putty / aluminum beading in square n exc 0.5 sq.m in each pane complete all as specified and directed.
S&F, 15 mm galvanised steel tubes, light grade including making it concealed complete all as specified and directed.
All as per Sl item No. 108 above, but 20 mm tube.
S&F, 20mm ball brass valves, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
M&L for boring of bored for 450mm dia cast in situ piles 7m deep in any soil and getting out and disposal of spoil to a distance 50m using DMC method (Direct Mud Circulation) including using of bentonite as per IS 6186 (1986) is required and complete all as specified and directed by Engineer-in-Charge.
Carrying out initial load testing (Compression Test) on 450mm dia piles all as per IS complete all as specified and directed in the connected IS including necessary, anchoring and support / size to be casted / provided as required.
Carrying out routine load testing (Compression Test) on 450mm dia piles all as per IS complete all as specified and directed.
M&L for control concrete M-30 design mix as in bored pile by using tremie pipe and as directed by Engineer-in-Charge and as specified in drawing.
Carrying out initial load testing (Lateral Test) on 450mm dia piles all as per IS complete all as specified and directed in the connected IS including necessary, anchoring and support piles of suitable load / size to be casted / provided as required.
Carrying out routine load (Lateral Test) on 450mm dia piles all as per connected IS complete all as specified and directed.
Carrying out pile integrity testing for 450mm dia pile complete all as per connected IS and all as specified and directed.
Demolition of RCC M-30 in pile foundation (except bars) from the cut off level and complete all as directed by Engineer-in-Charge.
M&L for controlled concrete of grade M-30 design mix (using 20mm graded stone aggregate) foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc, basement slabs, under-reamed piles and mass concrete and in pile cap complete all as specified and directed.
M&L for roof trusses, bracing (framed), trussed, purlins, crane gantries, CHS, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) confirming to Fe-410W (Gde E-250) quality 'B' including distance pieces, cleats etc, complete all as specified and directed.
M&L for protection paint over steel surface to be carried out at as per IS 800 (2007) table 29(a) & 29(b) with life expectancy of about 20 years and as prescribed in drawings. Note: (i) Shop coat of primer with blast clean. (ii) Prefabrication primer 2 pack zinc-rich epoxy, 20um. (iii) Post fabrication primer 2 pack zinc-rich epoxy, 25pm. (iv) Primer shall be allowed to dry completely and 2 pack epoxy micaceous iron oxide paint protection shall be applied. (v) Top coat of high build chlorinated rubber paint shall be applied on the site after completion of erection.
Supply & lay, reinforced concrete pipes 300mm dia, class NP3, laid and jointed complete with collars as specified and directed by Engineer-in-Charge.
M&L for pebbles of guage exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15cm thick, watered and rolled / rammed to a true surface complete all as specified and directed.
M&L for charcol fitting in well / soak well / rainwater harvesting pit etc, complete all as specified and directed.
M&L for sand filling under the well or in foundations including watering and consolidation complete all as specified and directed.
M&L for gravels of guage exc 100mm but n exc 200mm deposited, spread and levelled in layers n exc complete all as specified and directed.
M&L for GI stainer wire mesh having the nominal dia of wire 3mm fixed to angles (square angles) by welding and as directed by Engineer-in-Charge.
S&F, 150mm dia (minimum 5mm thick) PVC slotted pipe of 3 layer having the holes / spot of 10mm at alternative distance of 100mm in bore wells complete all as specified and directed.
M&L for making bore in earth 300mm dia and inserting the 150mm dia GI pipe, light grade upto the depth 7m or more and as directed by Engineer-in-Charge.
S&F, repair cast iron cover, brackets, gully traps, grating etc, complete all as specified and directed.
Returning, filling in, including, spreading, leveling, watering and well ramming in layers n.exc. 25 cm in soils complete all as specified and directed.
Removing excavated material exc 1.50 km but n exc. 5 km outside of defence land completed all as specified and directed. Note: Dumping site to be decided by contractor on his conveyance.
Removing excavated material exc 5 km but n exc. 15 km and depositing where directed completed all as specified and directed.
INTERNAL ELECTRIFICATION Taking down carefully the existing aluminium point wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets, ceiling rose, regulators and light fittings any type etc, by unscrewing and taken away from site complete all as specified and directed.
M&L for Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade conforming to IS-694-2010 and as amended upto date drawn through and including non metallic rigid PVC conduit 25mm dia medium grade concealed type but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part-I, ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed / recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for one light point controlled by one 5 Amps one way switch.
All as per Sl item No. 135 here in above, but one celing / exhaust fan point controlled by one 5 Amps one-way switch.
All as per Sl item No. 135 here in above, but one 3 pin, 5Amps, switch socket outlet point on independent board.
All as per Sl item No. 135 here in above, but one 3 pin, 5Amps, switch socket outlet point on same board.
All as per item No. 135 here in above, but 2.5 sqmm copper conductor wiring with 2.5 sqmm copper conductor as earth continuity for power point of 16 Amp.
S&F, modular switch one way 6 Amp, 1 module complete all as specified and directed.
S&F, socket 6A - 2/3 pin combined 2 module complete all as specified and directed.
S&F, ceiling rose surface backelite three terminal complete all as specified and directed.
S&F, modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F, socket 6A/16A - 6 pin combined 2 module complete all as specified and directed.
S&F in replacement sheet steel metal enclosure distribution board MCB DB SPN, 12 Way, double door, 240Volts, IP-43 protection, factory made powder coated flush mounting with 200 Amps rated bus bar complete all as specified and directed.
S&F in replacement sheet steel metal enclosure distribution board MCB DB SPN, 8 Way, double door, 240Volts, IP-43 protection, factory made powder coated flush mounting with 200 Amps rated bus bar complete all as specified and directed.
S&F in replacement sheet steel metal enclosure distribution board MCB DB SPN, 4 Way, double door, 240Volts, IP-43 protection, factory made powder coated flush mounting with 200 Amps rated bus bar complete all as specified and directed.
S&F, sheet metal enclosure powder coated, distribution boards VTPN MCCB 125 A DB, double door, provision of TPN MCCB 125 Amps, 16 KA as incomer, 12 way, 415V, double door type IP 43 protection, isolated neutral bar and insulated bus bar assembly cement spill protector, door earthing, complete. Make: INDOASIAN, Modules F1 + 36 or equivalent of HAVELLS / L&T / LEGRAND.
S&F, MCB, SP, 240V, 6 to 32 Amps 'C' curve 10KA rupturing capacity complete all as specified and directed.
S&F, MCB, SPN, 240V, 40 Amps to 63Amp 'C' curve 10KA rupturing capacity complete all as specified and directed.
S&F, MCCB of capacity 125 Amp, 415V, TPN with 16 KA breaking capacity complete all as specified and directed.
S&F, metal clad industrial plug and socket 415 volt, 5 pin, 3P +N+E, 415V AC of 125 Amp ratings complete all as specified and directed.
M&L for sub main wiring with two runs of 6.0 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable, fire retardant low smoke drawn through and including PVC concealed conduit medium grade ISI marked 25 mm dia (external) but shall be increased as per actual site requirement in accordance, with wall thickness not less than 1.8 mm complete with all necessary fitting and including with conduit accessories and one run of 6.0 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable fire retardant low smoke as earth wire conductor, fixed on wall / ceiling including taking down old unserviceable sub main wiring complete all as specified and directed. Note: Two runs of 6 Sqmm and one run of earth wire of 6 Sqmm and PVC conduit will be measured as one length of sub main wiring.
M&L for sub main wiring with two runs of 4.0 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable, fire retardant low smoke drawn through and including PVC concealed conduit medium grade ISI marked 25 mm dia (external) but shall be increased as per actual site requirement in accordance, with wall thickness not less than 1.8 mm complete with all necessary fitting and including with conduit accessories and one run of 4.0 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable fire retardant low smoke as earth wire conductor, fixed on wall / ceiling including taking down old unserviceable sub main wiring complete all as specified and directed. Note: Two runs of 4 Sqmm and one run of earth wire of 4 Sqmm and PVC conduit will be measured as one length of sub main wiring.
M&L for sub main wiring with four single core PVC insulated unsheathed, 1100 Volts grade, copper cable 4 x 16.0 sq. mm stranded conductor and drawing through and including rigid PVC non metalic concealed conduit of size 25mm dia medium grade with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, 2 run of cable 16 sqmm copper conductor and connected to common earth dolly including taking down old submain wiring complete all as specified and directed. Note: One run of PVC conduit, 4 runs of cable and 2 runs of earth wire shall be measured and paid as one unit.
M&L for dismantling of old fan for servicing purpose and refixing the same after complete servicing overhauling and one coat of painting with existing colour and writing MES No. including modifying / replacing down rod as per site condition and refixing the fan as directed and making connection with PVC copper wire and making good to damaged surface of wall / ceiling to match existing finish complete all as specified and directed.
S&F of Industrial Air circulator fan type 450 mm sweep, AC, single phase 230/240 Volts on wall complete with fixing arrangement like clamps / nut & bolts accessories including connecting with suitable size of copper flexible wire complete all as specified and directed.
S&F, Pedestal Air Circulator 600 mm sweep 230 / 240 Volts with all accessories including connection and provision of flexible copper wire from ceiling rose to fan complete all as specified and directed.
S&F, exhaust fan, heavy duty with metalic body 450 mm sweep complete with louver shutter, 230 / 240 V, 1400 RPM suitable for hangar at any height including making hole in stone masonary wall and finishing the same with plastering etc including making connection with flexible copper wire from ceiling rose to exhaust fan complete all as specified and directed.
S&F, exhaust fan, heavy duty with metalic body 300 mm sweep complete with louver shutter, 230 / 240 V, 1400 RPM including making hole in stone masonary wall and finishing the same with plastering etc including making connection with of flexible copper wire from ceiling rose to fan complete all as specified and directed.
S&F, circular LED highbay light with tapered design and excellent thermal management alongwith IP-66 protection suitable for Hanger / technical building complete with fixing arrangement like hooks / bracket / suspended rod of capacity 110 watt with lumens of 110 Lumens / watt complete all as specified and directed.
S&F, LED batten with rod with aluminium housing provided for efficient heat dissipation with High quality PC Diffuser. Reliable and robust housing structure, maximize the endurance over the life time Slim Integrated design, easy to install Efficacy 1 x 20 watts fixing on wall / ceiling with lumens 125 Lumens / watt complete all as specified directed.
S&F, modular fan step regulator, 120W-2 module complete all as specified and directed.
M&L for earthing complete with 60cm x 60cm x 6 mm thick GI plate electrode buried in ground vertically not less than 2.25mtrs deep below ground level with top edge of the plate not less than 1.5mtrs below ground level with GI wire 4.0mm dia as earthing lead including necessary excavation and earth work (in any of strata) providing charcoal dust, salt mixed in continuous layers all around the earth plate, PCC (1:3:6) type C1 in chamber with CI frame with cover, 20mm dia bore light grade GI watering pipe furnel etc fixing of GI Pipe 15 mm bore protection for earthing wire from earth pit to test point complete & making connection all as specified in electrical plate No. 3 and directed by Engineer-in-Charge.
M&L for chemical earthing complete with copper earth plate electrode 90cm x 60cm x 5mm thick buried directly in ground (earth pit not less than 3 mtr deep below ground level) with top edge of the plate not less than 2.10 mtr below normal ground level, connected to and including copper earth strip of 32 x 6 mm by means of rivetting and brazing and protected by GI pipe light grade of 40mm dia upto the test point i.e. upto 7.5 mtr, including providing alternate layers up to full volume of pit by necessary chemical compound, magnesium sulphate & vegetable soil all around the plate 15 cm depth and width minimum including PCC 1:3:6 type C1 chamber with RCC cover of suitable size including testing on ground and desired earth resistance value shall be 0.5Ώ (ohms). If the desired value not achieved and same shall be re-done by the contractor without extra cost to the department complete and including excavation and earth work in any type of strata and cleaning of site all as specified in MES SSR Part-I and directed by Engineer-in-Charge.
S&F, copper earthing strip of size 20 x 3.00mm for connection from earth test point to equipment with help of complete brazing etc., complete all as specified and directed.
S&F, LED street light fittings 36 Watt, 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp GI bracket of adequate length and size with fixing clamps etc with impact corrosion resistant complete including thermal management in multiple optics with IP-65 protection with lumens 110 Lumens / Watt complete all as specified and directed.
AIR CONDITIONING Supply and install, hi wall split type Air conditioner of inverter type technology with indoor and outdoor units complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity of 1.5 TR and 220 to 250 volt 50 Hz all as specified and directed (including copper pipe upto 5mtr length and refrigerant gas as per OEM) with the following specification:- (i) Air filtering unit - Dust proof and anti bacteria filter (ii) Remote Control - Wireles with LCD display (iii) Indoor unit noise level-Indoor unit < 40 DB (iv) Air flow rate - 425 CFM or more (v) Refrgrant type - Eco friendly refrigrant and as per currently industry standard (vi) Waranaty - 1 year warranty for the whole AC and 5 years waranty on compressor (vii) Comressor - Hermitically sealed rotary type.
S&F, voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 volts with out put voltage stablized at 230 volts with accuracy of +/- 2.5% and of capacity 4 KVA complete all as specified and directed.
M&L for factory fabricated MS stand duly powder coated painting suitable for fixing outdoor unit of 1.5 TR air conditioner and fixing arrangement at suitable height complete all as specified and directed.
M&L for HDPE pipe 25 mm dia with fittings fixed to wall on roof complete all as specified and directed.
Making opening / drilling of size 65 mm dia, using heavy duty stone driller / cutter machine in the stone masonary wall for installing spilit type air conditioners and for passing suction and discharge refrigerant pipe lines, drain pipe, cable etc and making good the disturbed surface complete all as specified and directed.
FIRE ALARM M&L for sub main wiring complete with two single core 1.5 Sqmm PVC insulated heavy duty and unnsheathed cable with multistranded copper conductor FRLSH and drawing through in and including rigid PVC conduit 25mm dia heavy duty with accessories fixed on surface with suitable clamps of suitable size and connecting terminal ends including provision of 1 run of 1.5 Sqmm insulated copper cable for earth continuity conductor and connecting to earth connectivity complete all as specified and directed. Note: Three runs of 1.5 Sqmm and one run of PVC conduit shall be measured as one length for payment purpose.
S&F, addressable type multi sensor detector with heat and smoke combination complying with and type certified to EN-45 complete all as specified and directed.
S&F, sounder with strobe at 85 dB @ 3mtrs for audible and flashing for visual indication with control module and fixed on wall surface and connecting up with all accessories complete all as specified and directed.
S&F, Response indicator complete all as specified and directed.
S&F, Addressable manual call point resettable type complete all as specified and directed.
S&F, fire alarm contol panel complying with BS EN 54 single loop panel with 99 detector & 99 module upto 200 detector and module complete with all connection with the accessories like RI / Smoke detector / hooter and beam detector etc, complete all as specified and directed.
S&F, Addressable type flame detectors with UV / IR detection capacity (add up cost of module to be a complete set, the type of module shall be relay type module) complete all as specified and directed.
S&F, fault / short circuit isolator complete all as specified and directed.
S&F, UPS for 30 min backup single phase AC input 160 to 260V and out put 230 + 1% of capacity 01 KVA complete with 7AH Battery 02 Nos and complete connection with fire alarm control panel complete all as specified and directed.
CRANE Design, supply, install, testing & commissioning eletrically operated over head travelling (EOT) crane of capacity to lift 20 Ton conforming to IS-3177 & IS-807 (latest version) having span of 17.65 mtrs (However actual span dimension shall be in accordance of plan of crane arrangement shown in drawings) bottom of hook height shall be 7.5metres from floor level, travel bay length 25 mtrs suitable for operation on 415 Volts, 3 phase, 4 wire, 50 Hz supply, double girder complete including Runway Rail on both sides of suitable size and shall be fabricated by using fresh tested steel beam (ISMB) conforming to IS:2062 Grade 'A' quality and same shall be installed on the steel structure with necessary fixing arrangement with hoist speed 2 mtrs / min, cross travel speed 10 mtrs / min & long travel 15 mtrs / min with micro speed 10% as recommended by OEM. The crane inclusive of control panel, power and controlling cables, pendent push button station, radio remote control operation, motors, gear box, rope drum & rope guide, limit switches, bottom block, wire rope, end truck buffer, brakes, wheels, pendent DSL system of shrouded bus bar for LT and pendent festoon for CT including providing platform on both sides of bridge girder with non skid 5mm thick steel chequered plate along the entire length of the crane, bridge width having 0.5 mtr securely fenced with double tired guard rails having minimum height of 1.1 mtr. Access ladder on both side of bay to facilitate maintenance of crane. Both ladders shall be provided iwth guards to prevent fall and comprising of following components / accessories all as specified and directed. Make: MUKUND / JESSOP / CRANEX / TOJYM / DINESH CRANES / ANUPAM / ELECTROMECH. (a) Double girder box type construction fabricated using fresh tested steel plates conforming to IS: 2062 grade 'A' quality obtained directly from main steel producers such as SAIL, RINL, TISCO.
(b) Squirrel cage induction motor crane duty motors TEFC, 'F' class insulation suitable capacity conforming to IS: 325 & IS: 123 and as amended upto date suitable for 150 starts per hour and 40% CDF for hoist, CT & LT to work on AC 415 volts, 3 phase, 50 Hz. (c) Electromagnetic disc brakes / shoe type brakes / hydraulic thruster type brakes shall be provided in all motions with suitable sizes. (d) Wheels shall be forged made of C55 Mn 75 carbon steel and suitable hardness, double flanged straight tread type fitted with antifriction roller bearing with supported on "L" type live steel axels bearing housing assembly. (e) Wire rope with fibre core of size 16mm dia, having 08 falls conforming to IS: 2266 minimum factor of safety and tensile strength 1960N/mm2 as per ISO: 4309:1990 complete with rope drum fabricated from seamless pipe duly machined and grooved to accommodate full length of rope in one layer. The drum shall be mounted on antifriction ball / roller bearings. Make: Usha Martin. (f) Gear box of crane shall be totally enclosed in dust proof construction shall be machined from alloy steel and hardened. All gearing is enclosed in a rugged steel housing and initial filling of oil / grease splash lubricated.
(g) Control panel indoor type made out of 2mm thick CRCA dust and vermin proof sheet powder coated painting comprising of variable speed drives (VVVF type) meeting the latest crane control solution enhances crane performances without worries and smooth operation, different operating speed for each process, accurate positioning, suitable switchgears, contactors, meters, relay transformers and components, control wiring etc as per OEM. (h) Control wiring and power wiring, PVC flexible pendent festoon system supported on MS trolley for CT and DSL system of suitable rating for LT all as per OEM. (j) Limit switches for upper and lower hoisting. (k) Bottom block shall be equipped with protective guard around the opening, shank type forged hook 'C' type, swivelling on thrust bearing tested as per IS 15560. (l) Emergency stop button to shutting off the power to the main contractors shall be provided. (m) End carriages with standard rolled steel section or welded plate box section type shall be assembled to ensure alignment of bearings and axles, twin drive arrangement, main cross girders to end trucks connection are bolted to ease in assembly. Rubber buffers on all end trucks when a moving crane or trolley reaches the ends of its permitted travel. (n) Hoisting machinery / crab of heavy duty industrial type.
(o) Painting of crane with one coat of primer and two coats of synthetic enamel paint of golden yellow of 25 micron. Final touch up will be done after erection at site and writing the details of crane like capacity, date of installation, load details etc. (q) Pendent push button station shall have push buttons for each motion, bridge light, siren / bell, on and off switches, emergency stop switch and shall be hanged in the middle of girder with chrome plated steel chain duly covered with sleeve. (r) Radio remote control for all motions and shall have multispeed steps of operation complete with rechargeable batteries and battery charger. (s) 03 Nos of LED light fitting 90 watts shall be provided under the girder - 02 Nos and 01 No under CT trolley. (t) Earthing shall be carried out as per IS of quantity as suggested by OEM as per SSR Part -I (specifications) Electrical Plate No. 03. (u) Welded joint testing shall be subjected to 10% X-ray testing and X-ray films to be provided for evaluation.
Design, supply, install, testing & commissioning eletrically operated over head travelling (EOT) crane of capacity to lift 5 Ton conforming to IS-3177 & IS-807 (latest version) having span of 21.5 mtrs ( However actual available span and other dimensions shall be checked by the contractor before quoting) bottom of hook height shall be 7.5metres from floor level, travel bay length 25 mtrs suitable for operation on 415 Volts, 3 phase, 4 wire, 50 Hz supply, double girder Runway Rail on both sides of suitable size and shall be fabricated by using fresh tested steel beam (ISMB) conforming to IS:2062 Grade 'A' quality and same shall be installed on the existing RCC column brackets with necessary fixing arrangement with hoist speed 2 mtrs / min, cross travel speed 10 mtrs / min & long travel 15 mtrs / min with micro speed 10% as recommended by OEM. The crane inclusive of control panel, power and controlling cables, pendent push button station, radio remote control operation, motors, gear box, rope drum & rope guide, limit switches, bottom block, wire rope, end truck buffer, brakes, wheels, pendent DSL system of shrouded bus bar for LT and pendent festoon for CT including providing platform on both sides of bridge girder with non skid 5mm thick steel chequered plate along the entire length of the crane, bridge width having 0.5 mtr securely fenced with double tired guard rails having minimum height of 1.1 mtr. Access ladder on both side of bay to facilitate maintenance of crane. Both ladders shall be provided with guards to prevent fall and comprising of following components / accessories all as specified and directed. Make: MUKUND / JESSOP / CRANEX / TOJYM / DINESH CRANES / ANUPAM / ELECTROMECH. (a) Double girder box type construction fabricated using fresh tested steel plates conforming to IS: 2062 grade 'A' quality obtained directly from main steel producers such as SAIL, RINL, TISCO.
(b) Squirrel cage induction motor crane duty motors TEFC, 'F' class insulation suitable capacity conforming to IS: 325 & IS: 123 and as amended upto date suitable for 150 starts per hour and 40% CDF for hoist, CT & LT to work on AC 415 volts, 3 phase, 50 Hz. (c) Electromagnetic disc brakes / shoe type brakes / hydraulic thruster type brakes shall be provided in all motions with suitable sizes. (d) Wheels shall be forged made of C55 Mn 75 carbon steel and suitable hardness, double flanged straight tread type fitted with antifriction roller bearing with supported on "L" type live steel axels bearing housing assembly. (e) Wire rope with fibre core of size 12mm dia, having 04 falls conforming to IS: 2266 minimum factor of safety and tensile strength 1960N/mm2 as per ISO: 4309:1990 complete with rope drum fabricated from seamless pipe duly machined and grooved to accommodate full length of rope in one layer. The drum shall be mounted on antifriction ball / roller bearings. Make: Usha Martin. (f) Gear box of crane shall be totally enclosed in dust proof construction shall be machined from alloy steel and hardened. All gearing is enclosed in a rugged steel housing and initial filling of oil / grease splash lubricated.
(g) Control panel indoor type made out of 2mm thick CRCA dust and vermin proof sheet powder coated painting comprising of variable speed drives (VVVF type) meeting the latest crane control solution enhances crane performances without worries and smooth operation, different operating speed for each process, accurate positioning, suitable switchgears, contactors, meters, relay transformers and components, control wiring etc as per OEM. (h) Control wiring and power wiring, PVC flexible pendent festoon system supported on MS trolley for CT and DSL system of suitable rating for LT all as per OEM. (j) Limit switches for upper and lower hoisting. (k) Bottom block shall be equipped with protective guard around the opening, shank type forged hook 'C' type, swivelling on thrust bearing tested as per IS 15560. (l) Emergency stop button to shutting off the power to the main contractors shall be provided. (m) End carriages with standard rolled steel section or welded plate box section type shall be assembled to ensure alignment of bearings and axles, twin drive arrangement, main cross girders to end trucks connection are bolted to ease in assembly. Rubber buffers on all end trucks when a moving crane or trolley reaches the ends of its permitted travel. (n) Hoisting machinery / crab of heavy duty industrial type.
(o) Painting of crane with one coat of primer and two coats of synthetic enamel paint of golden yellow of 25 micron. Final touch up will be done after erection at site and writing the details of crane like capacity, date of installation, load details etc. (q) Pendent push button station shall have push buttons for each motion, bridge light, siren / bell, on and off switches, emergency stop switch and shall be hanged in the middle of girder with chrome plated steel chain duly covered with sleeve. (r) Radio remote control for all motions and shall have multispeed steps of operation complete with rechargeable batteries and battery charger. (s) 03 Nos of LED light fitting 90 watts shall be provided under the girder - 02 Nos and 01 No under CT trolley. (t) Earthing shall be carried out as per IS of quantity as suggested by OEM as per SSR Part -I (specifications) Electrical Plate No. 03. (u) Welded joint testing shall be subjected to 10% X-ray testing and X-ray films to be provided for evaluation. Note for Sl item Nos. 182 & 183: (i) However actual available span & other dimension are required to be checked by contractor before quoting (ii) Cranes shall be got executed (installed and commissioned) with the authorised representative of the manufacturer. (iii) 5 Ton EOT Crane shall be installed on the existing RCC column brackets by providing Runway Beam and Runway Rail (iv) 20 Ton EOT Crane shall be installed on the steel structure column by providing Runway Beam and Runway Rail.
Taking down, dismantling carefully without damaging to existing structure of 5 Ton Crane complete double girder, Runway beam with rail and motors, ropes, hook control panel and other components after disconnecting of electric connection carefully and hand over to AGE E/M store yard for their safe custody complete all as specified and directed. (NOTE : The quoted rate is inclusive of labour and transportation )
EXTERNAL ELECTRIC SUPPLY Supply, install testing & commissioning of CPRI approved indoor type, LT panel board suitable for 415 Volts, 3 phase, 4 wire, 50 HZ power distribution panel of suitable size, pre-wired with adequate size of single core PVC inslulated FRLS stranded copper conductor cable, control fuses, earthings terminals, lifting hooks, danger notice plate, free standing, front and back openable construction, floor mounting, dust and vermin proof of IP-52, provision for ventilation, compartimantalised design, hinged type double door with mechanical locking arrangement for each feeder, factory fabricated out of 2.0 mm thick CRCA sheet, 7 tank process powder coated painting fixed on and inlcuding MS angle iron frame of suitable size and bottom legs made of MS angle iron 50 x 50 x 6mm including necessary earth work, civil work with PCC 1:3:6 type C2 foundation and comprising of the following switch gear and accessories complete all as specified and directed:- (a) Bus bar chamber of 3 phase and neutral 4 strip, 415 volts with 600 Amps copper strip - 1 set (b) Moulded Case Circuit Breaker 4 pole 50 KA breaking capacity 400 Amps capacity (TMD) - 1 No (In coming) (c) Moulded Case Circuit Breaker 3 pole, 35 KA breaking capacity 200 Amps capacity (TMD) - 1 No (Out going) (d) Moulded Case Circuit Breaker 3 pole, 25 KA breaking capacity 160 Amps capacity with thermal magnetic trip unit (TMD) - 1 No (Out going) (e) Moulded Case Circuit Breaker 3 pole, 16 KA breaking capacity 100 Amps capacity with thermal magnetic trip unit (TMD) - 2 Nos (Out going)
(f) Moulded Case Circuit Breaker 3 pole, 16 KA breaking capacity 63 Amps capacity with thermal magnetic trip unit (TMD) - 3 Nos (Out going) (g) Three phase digital voltmeter 0-500volts - 01 No. (h) Three phase digital Ammeter 0-300 Amps - 01 No (j) LED Indicator lamp Red, Yellow, Blue - 01 Set (k) Complete internal wiring with suitable copper conductor wires - 1 Lot. (l) Provision of extra space for two more out going feeders suitable for 125 Amps MCCB. Note: All termination of existing cable should be provided with copper lugs / thimbles and suitable size of glands & rate for the same is deemed to be included in the item.
Supply, laying & testing, cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core complete all as specified and directed.
All as per Sl item No. 186 here in above, but of size 70 sqmm 3.5 core.
All as per Sl item No. 186 here in above, but of size 50 Sqmm 3.5 core.
All as per Sl item No. 186 here in above, but of size 35 sqmm 3.5 core.
All as per Sl item No. 186 here in above, but of size 25 sqmm 3.5 core.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for foundation etc for laying of cables, erection of poles, struts/stays etc not exceeding 10 sqm in hard /dense soil complete all as specified and directed.
Removing excavated soil n. exc 50 m and depositing where directed at a level n.exc. 1.5 mtr above the starting point completed all as specified and directed.
M&L for dry river sand for filling in the trenches below and around the UG cable for cushioning of cable including punning down complete all as specified and directed. Note:Punned thickness only shall be measured and paid
M&L for Un-reinforced pre cast concrete covers class LV type 250mm x 150mm x 40mm size factory made for cable protection complete all as specified and directed.
S&F, GI pipe light grade 80 mm dia for protection of UG cables under road or on wall complete all as specified and directed by Engineer-in-Charge.
M&L for cutting of black top cover of existing road upto 1 mtr depth and 60 cm wide for laying of UG cable and pipe line, refilling and making good after laying UG cable and pipe line with PCC 1:3:6 uptp 30 cm from top of the road surface comple all as directed by EIC.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply & laying, Synthetic Insulated Mats of size 2.00 Mx 1.00M x 3 mm thick suitable for electrical shock safety upto 11 KV grade complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried in ground verticallyto a depth not less than 2.25mtrs below normal ground level with top edge of the plate not less than 1.5mtrs below ground level connected to galvanised iron / steel strip of size 32 x 6mm thick by means of bolts, nuts, check nuts and washer made out of ganvanised iron or steel all as shown in electrical plate No. 03 of SSR Part-I and earth strip protected by GI pipe light grade 40mm bore and through test point including necessary earth work and excavation in any type of soil, GI light grade 20 watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 design mix cover slab 6mm dia MS bars at 100mm c/c both ways with MS hooks 6mm dia ms bars etc complete all as specified and directed and testing on completion. Note: GI Strip upto 7.5 Mtr length shall be deemed to include in this items.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit / GI pipe or fixed to poles or any other indicated situation for loop earthing etc as required of GI strip 32 x 6 mm complete all as specified and directed.
S&F, cable route indicator comprises and made out of CI anodised plate of suitable dia duly embosised with LT cable with height of two feet 10mm MS road embedded on PCC 1:3:6 concrete base complete all as specified and directed.
M&L for PCC 1:2:4, Type B2 using 40mm graded aggregate as in surface channels and drains complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred / stopped end etc. complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping, lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing complete all as specified and directed.
M&L for concrete bed 1:4:8 type D2 to 150 mm drain pipes including packing under, and hunching against the sides of pipes after they are laid and tested; in complete all as specified and directed.
M&L for 150mm slat-glazed stoneware drain pipes laid in trenches and joints complete all as specified and directed.
S&F, PVC (SWR) 150mm bore pipes double socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F, PVC (SWR) 200mm bore pipes double socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F, PVC (SWR) reducer for 150mm dia to 200mm dia pipes fixed with solvent cement and as directed by Engineer-in-Charge.
S&F, PVC (SWR) 'T' at joint for 200mm dia pipes with solvent cement and as directed by Engineer-in-Charge.
M&L for Septic tank for 30 users on site LLDPE (With UPFLOW FILTER INLCUDING MEDI) designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and directed.
M&L for Soakage well of size 1.8 M dia x 3.0 M effective depth incl excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25 / SFRC cover, interconnecting pipes of RCC / DWC complete filled with brick bats of size complete all as specified and directed.
Sri Lakshmi Constructions
SIGNATURE INFRASTRUCTURES(E DHARANI KUMAR REDDY)
Phoenix Infra
C R R CONSTRUCTIONS
M/s M Munivenkatappa and Company
TRIVENI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .