| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.9 LAccepted-AOC 194 IIND FLOOR POCKET 9 SECTOR 24 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹27.9 L Quoted ₹28.7 L | 1 | Accepted-AOC OK |
| 2 | 2₹29.4 L+₹63,560 (2.21%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | ₹29.4 L+₹63,560 (2.21%) | 2 | Rejected-Finance Not the Lowest Tenderer |
| 3 | 3₹29.4 L+₹66,930 (2.33%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | ₹29.4 L+₹66,930 (2.33%) | 3 | Rejected-Finance Not the Lowest Tenderer |
| 4 | 4₹29.4 L+₹67,295 (2.34%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹29.4 L+₹67,295 (2.34%) | 4 | Rejected-Finance Not the Lowest Tenderer |
| 5 | 5₹30.4 L+₹1.7 L (5.86%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹30.4 L+₹1.7 L (5.86%) | 5 | Rejected-Finance Not the Lowest Tenderer |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
1 Mar 2021, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
REPAIR/ REPLACEMENT OF UNSERVICEABLE POINT WIRING, FITTING/ FIXTURES, DB AND UNSERVICEABLE EARTHING AT ZONE-B, OFFICER ACCN, WARDS AND MH LINE AND OUTSOURCING OF COMPUTER OPERATORS UNDER GE (E/M) BASE HOSPITAL DELHI CANTT-10
2021_MES_416025_1
GE/BH-75/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D Category b(i)
7 documents required · 7 mandatory
₹500
Yes
GE E/M BASE HOSPITAL DELHI CANTT
₹99,000
Yes
23 Mar 2021
27 Jan 2021
3 Mar 2021
27 Jan 2021
1 Mar 2021
11 Feb 2021
Amount
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendent, regulator socket etc shall be measured and paid separately) and making good disturbed surfaces of wall floor etc complete all as specified and as directed.
M&L point wiring for modular switches with 1.5 Sqmm, PVC insulated, unsheathed, multistranded, copper conductor Cable, FRLS, 1100 Volt grade, drawn through and including concealed, rigid non-metallic PVC Conduit of minimum 25mm dia or as per site requirement with all fittings, including cadmium plated screws as per IS, including 1.5 Sqmm size, PVC insulated, unsheathed, copper earth continuity conductor, connected to earth dolly, suitable for One light/fan/bell point controlled by one No, 5 Amp, one way switch/bell push complete all as specified and as directed.
All as per item No. 2.00 here in before but for one three pin, 5 Amp, socket out let on independent board complete all as specified and as directed.
All as per item No. 2.00 here in before but for one three pin, 5 Amp, socket out let on same board complete all as specified and as directed.
All as per item No. 2.00 here in before but for one light point controlled by two Nos, two way switches complete all as specified and as directed.
All as per item No. 2.00 here in before but point wiring with 2.5 Sqmm, multistranded, copper conductor cable, for 15 Amps socket outlet on independent board with 2.5 Sqmm size earth conductor complete all as specified and as directed.
M&L point wiring for normal switches with 1.5 Sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, drawn through and including concealed, non rigid, medium grade, PVC Conduit of minimum 25mm dia as requirement of site including cadmium plated screws as per ISI, including replacement of 3 mm thick phenolic laminated sheet top covers on and including 1.2 mm thick sunk type CI/steel terminal box, concealed in wall, including 1.5 Sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light/fan/bell point controlled by one No, 5 Amp, one way switch/bell push complete all as specified and as directed.
All as per item No. 7.00 here in before but for one three pin, 5 Amp, socket out let on independent board complete all as specified and as directed.
All as per item No. 7.00 here in before but for one three pin, 5 Amp, socket out let on same board complete all as specified and as directed.
All as per item No. 7.00 here in before but point wiring with 2.5 Sqmm, multistranded, copper conductor cable, for 15 Amps socket outlet on independent board with 2.5 Sqmm size earth conductor complete all as specified and as directed.
All as per item No. 7.00 here in before but point wiring with 4 Sqmm, multistranded, copper conductor cable, for AC point on independent board with 4 Sqmm size earth conductor complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 1 or 2 module complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 3 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 4 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 6 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 8 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 12 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 16 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 1 or 2 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 3 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 4 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 6 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 8 modules complete all as specified and as directed.
S&F in replacement module metal flush box, 12 modules complete all as specified and as directed.
S&F in replacement module metal flush box, 16 modules complete all as specified and as directed.
S&F in replacement modular switch, 1 way, 6 Amp, 1 Module, complete all as specified and as directed.
S&F in replacement modular switch, 2 way, 6 Amp, 1 Module, complete all as specified and as directed.
S&F in replacement modular bell push, 6 Amp, 1 Module complete all as specified and as directed.
S&F in replacement modular Socket, 6Amp, 2/3 Pin, combined, 2 module complete all as specified and as directed.
S&F in replacement modular switch, 1 way, 16 Amp, 1 Module complete all as specified and as directed.
S&F in replacement modular Socket, 16/6 Amp, 3/5 Pin, combined, 2 module complete all as specified and as directed.
S&F in replacement modular Fan step regulator, 120W, 2 module complete all as specified and as directed.
S&F in replacement Plug Top, 5 Amps, 230 Volts, white, polycarbonate body, 3 pin type, including connecting complete all as specified and as directed.
S&F in replacement Plug Top, 15 Amps, 230 Volts, white, polycarbonate body, 3 pin type, including connecting complete all as specified and as directed.
S&F in replacement Lamp holder, white, Polycarbonate body, with back plate, suitable for batten fittings, fixed in position & connecting complete all as specified and as directed.
S&F in replacement Ceiling rose, PVC/ polycarbonate, isolated body type, three terminal, 240 volt, fixed in position & connecting complete all as specified and as directed.
S&F in replacement Bell ding dong, AC, 230 Volts, fixed in position & connecting complete all as specified and as directed.
S&F in replacement ultra slim, electronic type, ballast suitable 1 x 36 / 40 watts fluorescent tube light fitting & connecting all as specified and as directed.
S&F in replacement LED Driver suitable for 36/39 Watt, 240 Volt, 50 Hz for 2x2 LED light fitting & connecting complete all as specified and as directed.
S&F in replacement Switch Piano type, white polycarbonate body, 5 Amp, 230 V, single pole, one way, including connecting complete all as specified and as directed.
S&F in replacement Switch Piano type, white polycarbonate body, 15 Amp, 230 V, single pole, one way including connecting complete all as specified and as directed.
S&F in replacement Socket outlet 2 in 1, 3 pin, 5 and 15 Amp, 230 V, Multipurpose, flush type, including connecting complete all as specified and as directed.
S&F in replacement Socket outlet 2 in 1, 3 pin, 5 Amp, 230 V, flush type, including connecting complete all as specified and as directed.
S&F in replacement stepped type electronic fan regulator, white polycarbonate body, flush type, 230 V, including connecting complete all as specified and as directed.
S&F in replacement sub main wiring with 2 runs of 4 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 20 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 4 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note:- Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
S&F in replacement sub main wiring with 2 runs of 6 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 6 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note:- Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
S&F in replacement sub main wiring with 4 runs of 10 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 32 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 10 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note:- Four run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
S&F in repair load line, distribution board, double door type, TPN, vertical, 4 way, suitable for accommodating up to 125 Amps MCCB with incoming frame three pole, including 250 Amp copper bus bar, neutral link, blanking plates etc complete all as specified and as directed. Make : Legrand Model: 5077 45 or equivalent model of Make mentioned in PS.
S&F in repair load line, distribution board, double door type, TPN, vertical, 8 way, suitable for accommodating up to 125 Amps MCCB with incoming frame three pole, including 250 Amp copper bus bar, neutral link, blanking plates etc complete all as specified and as directed. Make : Legrand Model: 5077 47 or equivalent model of Make mentioned in PS.
S&F in repair load line, distribution board, double door type, TPN, vertical, 12 way, suitable for accommodating up to 125 Amps MCCB with incoming frame three pole, including 250 Amp copper bus bar, neutral link, blanking plates etc complete all as specified and as directed. Make : Legrand Model: 5077 48 or equivalent model of Make mentioned in PS.
S & F in repair distribution board double door type, SPN, 4 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and as directed.
S & F in repair distribution board double door type, SPN, 8 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and as directed.
S & F in repair distribution board, double door type, SPN, 12 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and as directed.
Supply, fixing and connecting in replacement recessed Type, Full window, opal Diffuser, Ultra modern, slim LED Panel 2x2, 36W, size 595X595mm (Nominal), suitable for Existing false ceiling, with CRCA powder coated White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection minimum 3KV, safety & performance test as per IS:15885 Part 2/Sec, Total system Lumen not less than 4200, in Cool day Light (5700K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours, complete with all accessories as required complete all as specified and as directed. Make : Havells Model No :- STRATO2X2PLR36WLED857MOD with LED Driver Model No LEDDRIVER36V36WS or equivalent model of Make mentioned in PS.
Supply, fixing and connecting in replacement Surface/Wall Mounted, 9 Watt, integrated LED, 2 feet Fitting with Epoxy powder coated white polycarbonate channel housing. Total system Lumen of 9W LED shall be 800 or above in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy>100 Lm/w, THD(%) < 20, Complete with all accessories as required complete all as specified and as directed. Make - Havells Cat part No -LUMILINEBS9WLED865SPCWH or equivalent model of Make mentioned in PS.
Supply, fixing and connecting in replacement Surface/Wall Mounted, 20 Watt, integrated LED, 4 feet Fitting, with polycarbonate housing & opal diffuser finish, Integral electronic driver with Output short circuit protection, Surge Voltage Protection of minimum 3 KV and Safety test as per IS15885 Part 2/ Sec 13. Total system Lumen shall be 2000 or above in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy 100 Lm/w, THD(%) < 20, LED with Average life of 50000 Burning hours. Complete with all accessories as required complete all as specified and as directed. Make - Havells Cat part No - LUMILINEBS20WLED865SPCWH or equivalent model of Make mentioned in PS.
Supply, fixing and connecting in replacement LED security light fitting, 45 Watt, cast aluminium housing, toughened glass, silicon gasket, high power LED with lens for uniform distribution, pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including 1.5 Metre long, 40 mm bore, medium grade, GI pipe bracket with clamps and bolts complete all as specified and as directed. Make - Havells Cat Part No- ENDURAPEARLNEOSL45W LED757PASYTOPC or equivalent model of Make mentioned in PS.
M&L Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Building at another end GI earth wire encased in and including 15mm bore GI light grade pipe through upper end of earth plate up to main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
Taking down ceiling fan, exhaust fan including connection cable, dismantling blades and refixing & reconnecting the same after necessary repair/rewinding/painting etc complete all as specified and as directed. Note: Servicing/Rewinding/Painting of Fan shall be measured and separately under respective item of this Schedule.
M & L for painting of ceiling fans/ exhaust fan complete, with synthetic enamel paint as per existing colour by one coat spray painting including filling cavities with filler, including cleaning all dust complete all as specified and as directed.
M&L for servicing of ceiling fans/exhaust fan/wall fan /pedestal fan of any Make and sizes, carrying out minor repair such as greasing, oiling, fitting, testing complete all as specified and as directed.
M&L rewinding ceiling fan of any make and model, 1200 /1400 mm sweep, with super enamelled copper wire of required size, duly varnishing with high quality Varnish, including greasing & servicing and testing including taking down old winding wire complete all as specified and as directed.
All as per item No. 62.00 here in before but rewinding Exhaust fan of size 200mm to 300mm complete all as specified and as directed.
All as per item No. 62.00 here in before but rewinding Exhaust fan of size 380mm complete all as specified and as directed.
All as per item No. 62.00 here in before but rewinding Exhaust fan of size 450 mm complete all as specified and as directed.
S&F in replacement bearing No 6200/6201/6203/6204 suitable for Ceiling fans/Exhaust fan of existing make and size, for proper running including testing complete all as all as specified and as directed. (Note: Testing shall be done in MES store yard at contractor's expense).
S&F in replacement bush suitable for Ceiling fans/Exhaust fan/pedestal fan/wall fan of existing make and size, for proper running including testing complete all as all as specified and as directed. (Note: Testing shall be done in MES store yard at contractor's expense).
S&F in replacement capacitor 2.5 Mfd complete all as all as specified and as directed.
S&F in replacement capacitor 3.15 Mfd complete all as all as specified and as directed.
S&F in replacement capacitor 4.0 to 8.00 Mfd complete all as all as specified and as directed.
S&F in replacement Electronic Energy Meter, with LCD display, Class 1.0, 240 V, 50 Hz, 10-60 A , AC, Single Phase, Two Wire, conforming to IS-13779 and relevant IEC standards, including transparent hinge type meter box made from engineering plastic including 6 Sqmm, copper stranded wire, PVC insulated, 1100 Volt grade, of required length including taking down old unserviceable meter complete all as specified and as directed. (Note: Old unserviceable Energy Meter shall be deposited in MES store yard.)
S&F in replacement Electronic Energy Meter, with LCD display, Class 1.0, 240 V, 50 Hz, 10-60 A , AC, Three Phase, Four Wire, conforming to IS-13779 and relevant IEC standards, including transparent hinge type meter box made from engineering plastic including 6 Sqmm, copper stranded wire, PVC insulated, 1100 Volt grade, of required length including taking down old unserviceable meter complete all as specified and as directed. (Note: Old unserviceable Energy Meter shall be deposited in MES store yard.)
S&F in repair switch socket combination, 5/15 Amp, multipurpose, with PVC gang box complete all as specified and as directed.
S&F in repair switch socket combination, 5 Amp, multipurpose, with PVC gang box complete all as specified and as directed.
S&F in repair Fan rod, 2/3 feet long, made out of 20 mm bore GI pipe, with necessary clamps & nut bolt and other accessories complete all as specified and as directed.
S&F in repair PVC casing caping, medium grade, size 25 X 16 mm, including necessary accessories (Tee, elbow etc) & clamp, screw, rowel plug etc. complete all as specified and as directed.
S&F in repair PVC casing caping, medium grade, size 32 X 16 mm, including necessary accessories (Tee, elbow etc) & clamp, screw, rowel plug etc. complete all as specified and as directed.
S&F in repair Rigid, non-metallic, PVC conduit, medium grade, 20mm bore, including all fittings such as tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed.
All as per item No 78.00 here in before but 25 mm bore complete all as specified and as directed.
S&F in repair modular blanking plate, 1 Module complete all as specified and as directed.
S&F in repair white colour, prelaminated sheet (Hylam Sheet), 8x5 inch size, 3 mm thick complete all as specified and as directed.
S&F in repair white colour, prelaminated sheet (Hylam Sheet), 5x5 inch size, 3 mm thick complete all as specified and as directed.
S&F in repair PVC Gang box, 3x3 inch, for switch socket combination 5A complete all as specified and as directed.
Cutting chases, pinning in, including making good in cement mortar 1:3 including painting to match with the existing surface as in edges of landings, steps, cills, sunshades, shelves, lintels, etc; and for concealed conduit wiring, etc, cutting not exc 10 cm girth complete all as specified and as directed.
S&F in repair sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 20 Amps, 240 Volts complete all as specified and as directed.
S & F in repair MCCB 415 V, 125 Amps, 25 KA, 4 Pole complete all as specified and as directed.
S & F in repair MCCB 415 V, 100 Amps, 35 KA, 4 Pole complete all as specified and as directed.
S & F in repair MCB TPN, 415 Volts, 63 Amps complete all as specified and directed.
S & F in repair MCB TP, 415 Volts, 40 Amps complete all as specified and directed.
S & F in repair MCB SPN, 240 Volts, 40 Amps complete all as specified and directed.
S & F in repair MCB SPN, 240 Volts, 63 Amps complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 6 Amps to 32 Amp complete all as specified and as directed.
S & F in repair MCB SP, 240 Volts, 63 Amps complete all as specified and as directed.
Supply, fixing and connecting in replacement, Surface/Wall Mounted, Inverter LED light batten with opal diffuser, IP20, 4 Hrs Backup, 20/22 Watt, 4 feet long complete all as specified and as directed.
Supply, fixing and connecting in replacement, Surface/Wall Mounted, Inverter LED light batten with opal diffuser, IP20, 4 Hrs Backup, 10/12 Watt, 2 feet long complete all as specified and as directed.
Supply, fixing and connecting in replacement, Inverter LED Bulb, B22 cap, 9 watt, with Opal diffuser, IP20, 4 Hrs backup complete all as specified and as directed.
Outsource services of Data Entry Operators (05 Persons) under GE (E/M) Base Hospital for following work on all working days excluding Sundays and Gazetted Holidays complete all as specified and as directed:- (i) Data Entry & Preparation of reports & returns (ii) Other official typing work (iii) Maintenance of office records (iv) Filing & linking of correspondences for case of reference. (v) Taking direction & Putting up drafts accordingly. (vi) Compilation & Collection of data.
Notes for item No 97.00:- (a) Contractor's quoted rates shall be for 05 Nos Data Entry Operators on Monthly bases. (b) The contractor shall install and maintain a Biometric Based Attendance Monitoring System (BBAMS) and enrol their employed staff in it. (c) All outsourcing persons shall mark their biometric attendance on daily bases for morning and evening. (d) In case biometric machine is out of order, the same shall be repaired/replaced by the contractor immediately (Not later then 24 Hours) at his cost, failing which all Data entry operators shall be treated as "Absent" and recovery shall be made @ Rs 1200.00 per person per day. (c) The Data Entry Operator(s) shall be minimum Graduates/ Ex-Serviceman with sufficient knowledge of typing on Computer. (e) Contractor shall be bond to implementation of minimum wages as per gov policy, EPF and ESIC payment and quoted rate shall deemed to include these factors. Contractors shall made payment to the staffs through RTGS/ RTS in account of individual and submit the details of proof, EPF & ESIC of each staffs before asking of any payment (RAR or Final Bill). (f) Any absence of deployed personnel shall invite a compensation of Rs 1200/- per day per person. Contractor shall provide alternate arrangement, if any person is absent continuously for 7 days. No payment shall be admissible to contractor, when person is absent from duty.
Notes for item No 97.00 (Contd...):- (g) The estimated cost of the work in respect of BOQ Srl item No 97.00 (as based on minimum wages rates issued vide Central/ State) is Rs 13,65,000.00. If the quoted amount is found less than the estimated cost of Sr item No 97.00 of BOQ and tender of lowest bidder is considered for acceptance, then the lowest bidder shall have to deposit FDR in favour of Accepting officer for the difference in estimated cost and Accepted amount in respect of BOQ Sr item No 97.0 within 30 days from date of acceptance. In case the said FDR is not submitted within 30 days the amount in question shall be recovered from contractor’s first RAR/ Final bill whichever is earlier. However the FDR/recovered amount shall be released to the contractor after satisfactory completion of work. Attention is further invited added that when the amount of said recovery mentioned herein above is less than the amount of performance security as indicated under Clause 02 on page 04 of CA and Clause 12 on page 11 of CA, no FDR is required to be submitted for quoting less rate against BOQ Srl Item No 97.00. However if the amount of performance security is less than the FDR to be submitted for less quoting rate, the difference of performance security amount and FDR amount (for less quoting rates) shall be deposited by the lowest bidder (whose tender is accepted) in the form of FDR for difference amount over and above performance security within 30 days from the date of Acceptance.
Vishal Traders
Saini Enterprises
M/S ANIL KUMAR
SANJEEV ENTERPRISES
RUCHIKA ENGG.WORKS
M/s Adhikari construction co.
M/S GEETANJALI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .