| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-Finance | ₹10.1 L | L1 | Accepted-Finance OK |
| 2 | L2₹12.4 LAccepted-Finance | ₹12.4 L | L2 | Accepted-Finance OK |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA UDYAM UP 56 0002873 09AARFP4205H1Z1 R M | MEERUT | UTTAR PRADESH | 250103 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Raj Engineering Co. L1 | Avon Electricals L2 |
|---|---|---|---|---|---|
| 1.00 | Disconnection of the console panel form main supply to isolate the system for the repairing/ renovation of console Panel of filter bed no- 01 to 20 at filter house (South) HPWW – II. | 20 | Jobs | 30,000 ₹35,400 | 70,760 ₹83,496.8 |
| 2.00 | Removing the out lived, burnt and overheated control wiring from the system of the panels carefully and isolating the panel. | 20 | Jobs | 30,000 ₹35,400 | 50,760 ₹59,896.8 |
| 3.00 | Removing/dismantling all defective switch gears such as switch disconnectors, control relays, push buttons and indicating lamps etc. as per the site requirement. | 20 | Jobs | 50,000 ₹59,000 | 30,500 ₹35,990 |
| 4.00 | SITC of the following switch gears and accessories in the existing panel. A. Switch Dis-connector 32 Amps. Make - L&T/DJB Approved. | 14 | Nos | 46,200 ₹54,516 | 45,556 ₹53,756.08 |
| 5.00 | B) Power contactor4 Pole with standard coil voltage,110 VOLTS 50 h/z as per the existing model MN-12. Make - L&T/DJB Approved. | 32 | Nos | 92,800 ₹1,09,504 | 1,69,216 ₹1,99,674.88 |
| 6.00 | C) Bimetallic over load relay suitable for the above with blocks Make - L&T/DJB Approved. | 36 | Nos | 97,200 ₹1,14,696 | 67,716 ₹79,904.88 |
| 7.00 | D) Shrouded push button actuator (2 Position) complete (Red, Yellow, Green and Black). Make - DJB Approved. | 286 | Nos | 1,60,160 ₹1,88,988.8 | 1,01,816 ₹1,20,142.88 |
| 8.00 | E) Shrouded indicator light with element, screw & bulb 110 Volts
complete as required (Red, Green, Yellow, Black and Blue). Make – DJB Approved | 276 | Nos | 1,54,560 ₹1,82,380.8 | 78,660 ₹92,818.8 |
| 9.00 | F) Fabrication/ fixing of name plates for indicator lamps & Push Buttons. | 408 | Nos | 38,760 ₹45,736.8 | 35,088 ₹41,403.84 |
| 10.00 | Thorough cleaning of Step-Down transformer by using CTC/MTO and checking the connection and inter-connections and finally Varnishing with Dr. Beck F-Class insulation varnish and baking the same. Testing of the Transformers. | 20 | Jobs | 30,000 ₹35,400 | 34,580 ₹40,804.4 |
Tender Value
Refer Docs
EMD Value
₹27,500
Closing Date
30 Jan 2026, 2:30 pmClosed
Executive Engineer (EnM)HP II
OFFICE OF THE EXECUTIVE ENGINEER (EnM) HP-II DELHI JAL BOARD GOVT OF NCT OF DELHI HAIDER PUR WATER WORKS, DELHI 110085
Repairing/Renovation of console panels for filter beds no.- 01 to 20 with allied works at Filter House (South) at HPWW-II.
2026_DJB_285586_5
NIT 11 (2025-26) / EE(EnM)HP-II
Open Tender
Miscellaneous Works
60 days
EE(EnM)HP-II
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJB
₹27,500
10 Feb 2026
24 Jan 2026
30 Jan 2026
24 Jan 2026
30 Jan 2026
24 Jan 2026
Disconnection of the console panel form main supply to isolate the system for the repairing/ renovation of console Panel of filter bed no- 01 to 20 at filter house (South) HPWW – II.
Removing the out lived, burnt and overheated control wiring from the system of the panels carefully and isolating the panel.
Removing/dismantling all defective switch gears such as switch disconnectors, control relays, push buttons and indicating lamps etc. as per the site requirement.
SITC of the following switch gears and accessories in the existing panel. A. Switch Dis-connector 32 Amps. Make - L&T/DJB Approved.
B) Power contactor4 Pole with standard coil voltage,110 VOLTS 50 h/z as per the existing model MN-12. Make - L&T/DJB Approved.
C) Bimetallic over load relay suitable for the above with blocks Make - L&T/DJB Approved.
D) Shrouded push button actuator (2 Position) complete (Red, Yellow, Green and Black). Make - DJB Approved.
E) Shrouded indicator light with element, screw & bulb 110 Volts complete as required (Red, Green, Yellow, Black and Blue). Make – DJB Approved
F) Fabrication/ fixing of name plates for indicator lamps & Push Buttons.
Thorough cleaning of Step-Down transformer by using CTC/MTO and checking the connection and inter-connections and finally Varnishing with Dr. Beck F-Class insulation varnish and baking the same. Testing of the Transformers.
Rewiring of the panel with suitable sized copper conductor wire, with thimble and lugs.
Making arrangement for the operation of the installed actuators by checking the existing wiring connections including replacing any defected wirings a per site requirement.
Testing and commissioning of the panel on no load and on full load after completion of the above works as per site requirement.
Painting of the console panel with two or more coat of synthetic enameled paint over a coat of steel primer after cleaning the surface and preparing the base as required.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
BOQ_377900.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid