The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees. N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The balance sheet and all other financial documents attested/certified by CAs to substantiate fulfilment of Financial Eligibility Criteria should be with UDIN, failing which the offer is likely to be rejected without any further reference.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Supply, installation, testing and commissioning of HT panels/LT panels, cable laying, wiring/rewiring of any building/office in central government or state government or public sector undertakings (also called Public sector Undertakings (also called public sector enterprise)
Substantially Completed Work means an ongoing work in which payment equal to or more than 90% of the present contract value (excluding the payment made for adjustment of Price variation (PVC), if any) has been made to the contractor in that ongoing contract and no proceedings of termination of contract on Contractor's default has been initiated. The credential certificate in this regard should have been issued not prior to 60 days of date of invitation of present tender.
Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
33 conditions · 6 needing a document upload
Mandate form should be uploaded as per attached format in document tab
GST: Tenderer has to fulfills GST Compliance as per Govt. norms
Tenderer may upload GST registration number and certificate.
Performance Guarantee: As per Indian Railways Standard General Condition of Contract 2022. 16.(4) Performance Guarantee The procedure for obtaining Performance Guarantee is outlined below: (a) The successful bidder shall have to submit a Performance Guarantee (PG) within 21 (Twenty one) days from the date of issue of Letter of Acceptance (LOA). Extension of time for submission of PG beyond 21 (Twenty one) days and upto 60 days from the date of issue of LOA may be given by the Authority who is competent to sign the contract agreement. However, a penal interest of 12% per annum shall be charged for the delay beyond 21(Twenty one) days, i.e. from 22ndday after the date of issue of LOA. Further, if the 60thday happens to be a declared holiday in the concerned office of the Railway, submission of PG can be accepted on the next working day. In all other cases, if the Contractor fails to submit the requisite PG even after 60 days from the date of issue of LOA, the contract is liable to be terminated. In case contract is terminated railway shall be entitled to forfeit Bid Security and other dues payable to the contractor against that particular contract, subject to maximum of PG amount. In case a tenderer has not submitted Bid Security on the strength of their registration as a Startup recognized by Department of Industrial Policy and Promotion (DIPP) under Ministry of Commerce and Industry, DIPP shall be informed to this effect. The failed Contractor shall be debarred from participating in re-tender for that work. (b) The successful bidder shall submit the Performance Guarantee (PG) in any of the following forms, amounting to 5% of the original contract value:- (i) A deposit of Cash; (ii) Irrevocable Bank Guarantee; (iii) Government Securities including State Loan Bonds at 5% below the market value; (iv) Pay Orders and Demand Drafts tendered by any Scheduled Commercial Bank of India; (v) Guarantee Bonds executed or Deposits Receipts tendered by any Scheduled Commercial Bank of India; (vi) Deposit in the Post Office Saving Bank; (vii) Deposit in the National Savings Certificates; (viii) Twelve years National Defence Certificates; (ix) Ten years Defence Deposits; (x) National Defence Bonds and (xi) Unit Trust Certificates at 5% below market value or at the face value whichever is less. Also, FDR in favour of FA&CAO (free from any encumbrance) may be accepted.
(c) The Performance Guarantee shall be submitted by the successful bidder after the Letter of Acceptance (LOA) has been issued, but before signing of the contract agreement. This P.G. shall be initially valid upto the stipulated date of completion plus 60 days beyond that. In case, the time for completion of work gets extended, the Contractor shall get the validity of P.G. extended to cover such extended time for completion of work plus 60 days. (d) The value of PG to be submitted by the Contractor is based on original contract value and shall not change due to subsequent variation(s) in the original contract value. (e) The Performance Guarantee (PG) shall be released after physical completion of the work based on 'Completion Certificate' issued by the competent authority stating that the Contractor has completed the work in all respects satisfactorily. (f) Whenever the contract is rescinded, the Performance Guarantee already submitted for the contract shall be encashed. (g) The Engineer shall not make a claim under the Performance Guarantee except for amounts to which the President of India is entitled under the contract (not withstanding and/or without prejudice to any other provisions in the contract agreement) in the event of: (i) Failure by the Contractor to extend the validity of the Performance Guarantee as described herein above, in which event the Engineer may claim the full amount of the Performance Guarantee. (ii) Failure by the Contractor to pay President of India any amount due, either as agreed by the Contractor or determined under any of the Clauses/Conditions of the Agreement, within 30 days of the service of notice to this effect by Engineer. (iii) The Contract being determined or rescinded under clause 62 of these conditions.
Security Deposit: As per Indian Railways Standard General Condition of Contract 2022. 16.(1) Security Deposit: The Security Deposit shall be 5% of the contract value. The Bid Security submitted by the Contractor with his tender will be retained/encashed by the Railways as part of security for the due and faithful fulfillment of the contract by the Contractor. Provided further that, if Contractor submits the Cash or Term Deposit Receipt issued from a Scheduled commercial bank of India or irrevocable Bank Guarantee Bond from a Scheduled commercial bank of India, either towards the Full Security Depositor the Part Security Deposit equal to or more than Bid Security, the Railway shall return the Bid Security, to the Contractor. Balance of Security Deposit may be deposited by the Contractor in cash or Term Deposit Receipt issued from Scheduled commercial bank of India or irrevocable Bank Guarantee bond issued from Scheduled commercial bank of India, or may be recovered at the rate of 6% of the bill amount till the full Security Deposit is recovered. Provided also that in case of defaulting Contractor, the Railway may retain any amount due for payment to the Contractor on the pending "on account bills" so that the amounts so retained (including amount guaranteed through Performance Guarantee) may not exceed 10% of the total value of the contract. The Irrevocable Bank Guarantee submitted towards Security deposit shall be initially valid up to the stipulated date of Maintenance period plus 60 days and shall be extended from time to time, depending upon extension of contract granted in terms of Clause 17A and 17B of the Standard General Conditions of Contract. Note: Security Deposit deposited in cash by the Contractor or recovered from the running bills of a Contractor or submitted by contractor as Term Deposit Receipt(s) can be refunded/returned to the contractor, in lieu of irrevocable Bank Guarantee bond issued from scheduled commercial bank of India, to be submitted by him, for an amount equal to or more than the already available Security Deposit, provided however that, in a contract of value less than Rs. 50 Crore, such refund/ return of the already available Security Deposit is permitted up to two times and in a contract of value equal to or more than Rs. 50 Crore, such refund / return of the already available Security Deposit is permitted up to three times.
16.(2) (i) Refund of Security Deposit: Security Deposit mentioned in sub clause (1) above shall be returned to the Contractor along with or after, the following: (a) Final Payment of the Contract as per clause 51.(1) and (b) Execution of Final Supplementary Agreement or Certification by Engineer that Railway has No Claim on Contractor and (c) Maintenance Certificate issued, on expiry of the maintenance period as per clause 50.(1), in case applicable. 16. (2) (ii) Forfeiture of Security Deposit: Whenever the contract is rescinded as a whole under clause 62 (1) of these conditions, the Security Deposit already with railways under the contract shall be forfeited. However, in case the contract is rescinded in part or parts under clause 62 (1) of these conditions, the Security Deposit shall not be forfeited. 16.(3) No interest shall be payable upon the Bid Security and Security Deposit or amounts payable to the Contractor under the Contract, but Government Securities deposited in terms of Sub- Clause 16.(4) (b) of this clause will be payable with interest accrued thereon
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Guarantee/Warrantee: The installation will be handed over to the Department after necessary testing and commissioning. The installation will be guaranteed against any defective design/ workman-ship. Similarly, the materials supplied by the contractor will be guaranteed against any manufacturing defect, inferior quality. The complete luminaire/LED bulb shall have replacement guarantee for satisfactory performance and manufacturing defects for a period of 60 months from the date of commissioning or 72 months from the date of supply whichever is earlier. For switch gear components and panels, warrantee should be 1year after date of installation , For all other items, the warrantee period will be for a period of 12 months from the date of handing over to the Department. Installation/ equipment or components thereof shall be rectified/repaired to the satisfaction of the Engineer-in-charge.
Shramikkalyan portal:- (i) Contractor is to abide by the provisions of various labour laws in terms of above clause 54,55, 55-A and 55-B of Indian Railways Standard General Conditions of Contract. In order to ensure the same, an application has been developed and hosted on website 'www.shramikkalyan.indianrailways.gov.in'. Contractor shall register his firm/company etc. and upload requisite details of labour and their payment inthis portal. These details shallbe available in public domain. The registration /updation in Portal shall be done as under: (a)Contractor shall apply for one time registration of his company/firm etc. in the Shramikkalyan portal with requisite details subsequent to issue of Letter of Acceptance. Engineer shall approve the contractor's registration in the portal within 7 days of receipt of such request. (b)Contractor once approved by any Engineer, can create password with login ID (PAN No.) for subsequent use of portal for all Letter of Acceptances (LoAs)issued in his favour. (c)The contractor once registered on the portal, shall provide details of his Letter of Acceptances (LoAs)/ Contract Agreements on shramikkalyan portal within 15 days of issue of any LoA for approval of concerned Engineer. Engineer shall update (if required) and approve the details of LoA filled by contractor within 7 days of receipt of such request. (d)After approval of LoA by Engineer, contractor shall fill the salient details of contract labours engaged in the contract and ensure updating ofeach wage payment to them on shramikkalyan portal on monthly basis. (e)It shall be mandatory upon the contractor to ensure correct and prompt uploading of all salient details of engaged contractual labour & payments made thereof after each wage period. (ii)While processing payment of any'On Account Bill' or 'Final Bill' or release of 'Advances' or 'Performance Guarantee / Security deposit', contractor shall submit a certificate to the Engineer or Engineer's representatives that "I have uploaded the correct details of contract labours engaged in connection with this contract and payments made to them during the wage period in Railway's Shramikkalyan portal at 'www.shramikkalyan.indianrailways.gov.in' till____Month,____Year.
Please read the Explanatory note for detail description of work, their make etc and all other attached documents before submission of Tender.
Any other reputed make/ brand other than as mentioned in the explanatory note may be included during the execution of the works on an urgent basis/as per direction when needed with approval of competent authority.
Electrical Work for extension of platform cover shed on extended portion & other amenities at ADL station & Provision for extension of platform cover shed on extended portion & other amenities at BVA station
ELECT-CHG-25-26-PLATEXT45~SER
ELECT-CHG-25-26-PLATEXT45
Open
Works - General
12 Months
Howrah, West Bengal
₹0
₹5.0 L
14 Apr 2026
20 Mar 2026
31 Mar 2026
210 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,11,66,951.62 | ||
| — | 100.00 | — | — | ||
| Point Wiring by PVC conduit /PVC Casing & Capping : -- Internal wiring for light, fan , plug points and night lamp points by 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked. Earthing the point with 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR- LSH), PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. or PVC Casing & capping, ISI marked, white color, double locking, Resistant to Flame Propagation to grade UL-94 V0, as per IS:14927 Part 2 : 2001 (Reaffirmed Year : 2017 ) or latest, Standard Length: 2 meter, Size: 25x16mm. including Modular Electrical Switch, 6 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark., including supply of all required materials like lamp holder,Aluminium, batten type, with shade carrier ring,ISI marked, Base: B-22 suitable for use at 250V, Conforming to IS: 1258(Rev.-3)-2005)with amdt-3. With BACK plate of 53 MM. Dia & 45 MM PCD.., ceiling rose, Modular type Socket outlet suitable for 3 pin plug, 6A, 230V, 2 Module, Shuttered (Operation of Shutter should be independant of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark ,suitable PVC moduler JB box ,switch Board, Spacers, Saddles,Bends, Tees to be provided as and where required as per direction of consignee,. Provision of moduler fan regulator should be kept on switch board .The plate should include 2 blank space for further installation of switches.including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete job. ( Two 5-ampere socket point treated as one point). | — | — | — | 71,455 | |
| — | 1500.00 | — | — | ||
| "Circuit/Sub-circuit wiring by PVC conduit/PVC casing capping wiring by 2.5 sq. mm, Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694-2010(reaffirmed 2020), ISI marked.Continuous Earthing with 2.5 sq. mm, Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694-2010(reaffirmed 2020), ISI marked through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. or PVC Casing & capping, ISI marked, white color, double locking, Resistant to Flame Propagation to grade UL-94 V0, as per IS:14927 Part 2 : 2001 (Reaffirmed Year : 2017 ) or latest, Standard Length: 2 meter, Size: 25x16mm. to be provided as and where required as per direction of consignee including PVC Circular Box and Ceiling rose if required with connection from running circuit as per direction of Consignee,stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 2.5 sq mm for phase & neutal and 1mtr of 2.5 Sq.mm PVC Cu. cable for earthing as per direction of Consignee. | — | — | — | 2,62,500 | |
| — | 1000.00 | — | — | ||
| "Circuit/Sub-circuit wiring by PVC conduit/PVC casing capping wiring by 4 sq. mm, Single Core, Multistrand (56/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked.Continuous Earthing with 4 sq. mm, Single Core, Multistrand (56/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked Cable through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. or PVC Casing & capping, ISI marked, white color, double locking, Resistant to Flame Propagation to grade UL-94 V0, as per IS:14927 Part 2 : 2001 (Reaffirmed Year : 2017 ) or latest, Standard Length: 2 meter, Size: 25x16mm. to be provided as and where required as per direction of consignee including PVC Circular Box and Ceiling rose if required with connection from running circuit as per direction of Consignee,stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 4 sq mm for phase & neutal and 1mtr of 4 Sq.mm PVC Cu. cable for earthing as per direction of Consignee. | — | — | — | 2,31,000 | |
| — | 30.00 | — | — | ||
| Concealed Wiring of light and fan point by 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR- LSH), PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked. Earthing the point with 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, FR-LSH, PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked,through PVC Conduit Pipe of Nominal Size 20mm/25mm(as per site requirement) and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. Modular Electrical Switch, 6 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark. including supply of all required materials like lamp holder,Aluminium, batten type, with shade carrier ring,ISI marked, Base: B-22 suitable for use at 250V, Conforming to IS: 1258(Rev.-3)-2005)with amdt-3. With BACK plate of 53 MM. Dia & 45 MM PCD.., ceiling rose, Modular type Socket outlet suitable for 3 pin plug, 6A, 230V, 2 Module, Shuttered (Operation of Shutter should be independant of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark ,suitable moduler stainless steel JB box with moduler PVC cover , stainless steel switch Board with moduler PVC cover,PVC Spacers, PVC Saddles,PVC Bends, PVC Tees to be provided as and where required as per direction of consignee,. Provision of moduler fan regulator should be kept on switch board . The plate should include 2 blank space for further installation of switches.including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.Covers or cover parts or parts of them, which are intended to ensure protection against electric shock, shall be held in place at two or more points by effective fixings..The cost includes supply of all materials to complete job. ( Two 5-ampere socket point treated as one point). | — | — | — | 26,940 | |
| — | 100.00 | — | — | ||
| "Concealed Sub circuit wiring by 2.5 sq. mm, Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694- 2010(reaffirmed 2020), ISI marked. with 2.5Sq mm earthing wire of Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR- LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694-2010(reaffirmed 2020), ISI marked. through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark with Supply & fixing of PVC Circular Box and Ceiling rose if required with connection from running circuit as per direction of Consignee. including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete the job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 2.5 sq mm for phase & neutal and 1mtr of 2.5 Sq.mm PVC Cu. cable as earthing with Supply of PVC Circular Box and Ceiling rose as per direction of Consignee." | — | — | — | 18,258 | |
| — | 50.00 | — | — | ||
| "Concealed Sub circuit wiring by 4 sq. mm, Single Core, Multistrand (56/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked with 4 Sq mm earthing wire of Single Core, Multistrand (56/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete the job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 4 sq mm for phase & neutal and 1mtr of 4 Sq.mm PVC Cu. cable as earthing." | — | — | — | 11,014 | |
| — | 35.00 | — | — | ||
| "Supply of modular PC Board consisting of 03 nos. switches with inbuilt LED indication, 03 nos. sockets and modular SP MCB 10A, 10kA, Type B- 01 No. with Stainless Steel 12M Box and all other accessories to complete job. Specs: Modular Electrical Switch, 6 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark and Modular type Socket outlet suitable for 3 pin plug, 6A, 230V, 2 Module, Shuttered (Operation of Shutter should be independant of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark. with modular SP MCB 10A, 10kA, Type B- 01 No. ISI marked, rated voltage: 240V AC, conforming to IS/IEC 60898-1:2015 (Reaffirmed Year:2024) or latest, with rated short circuit current capacity 10KA, fixed unadjustable time current characteristics suitable for use in protection of industrial, commercial and domestic electrical installations. along with 12M stainless steel Box, moduler cover plate and Stainless Steel boxes and all other accessories including stainless steel fastener, Pin Type Terminal End Lugs to complete job as per specification attached or with latest amendment or specification issued from HQ/GRC if any time to time. | — | — | — | 59,471.65 | |
| — | 35.00 | — | — | ||
| Fixing and commissioning of modular PC Board consisting of 03 nos. switches with inbuilt LED indication, 03 nos. sockets and modular SP MCB 10A, 10kA, Type B- 01 No. with Stainless Steel 12M Box, moduler cover plate including all other accessories to complete job with latest amendment or specification issued from HQ/GRC if any time to time, including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. (Wiring will be covered under Shedule item No. as per site requirement). | — | — | — | 916.3 | |
| — | 1000.00 | — | — | ||
| Shelter wiring by 2.5 sq.mm PVC cu wire through PVC conduit 25 mm dia. (1 Mtr. length means 8 nos. 2.5 sq.mm. PVC Cu wire and 1 no. 1sq.mm. Cu wire for earthing and 2 nos PVC conduit pipe) | — | — | — | 5,48,630 | |
| — | 1100.00 | — | — | ||
| Laying of cable / cables in under ground along the road through cable trench etc . as per standard drawing including necessary termination , connection and testing.Trenching and laying of U/G cables in any kind of soil trench of size minimum 0.40 mtr wide and 1 mtr deep covered with necessary bricks for protection of the cables including filling of space between brick and cable/cables with sand and refilling the trench with excavated soil, leveling up, and restoring the surface duly rammed. | — | — | — | 1,41,559 | |
| — | 100.00 | — | — | ||
| Laying of cable / cables across the road, track, drain etc through RCC/GI pipe confirming to IS standard of size 100mm or 150mm (or any suitable size as per field requirement based on the actual size of the cable) as per relevant specification and as per standard drawing with necessary termination, connections and testing .Cost also includes collection of cable/cables from Railway store if required.GI pipe will be supplied by contractor. | — | — | — | 29,459 | |
| — | 300.00 | — | — | ||
| Laying of cable/ cables on wall / structure through PVC casing pipe of size 4inches or 3inches with accessories or as per site requirement with suitable clamp / saddle/ fixtures etc with necessary termination, connection and testing as per standard drawing.Cost also includes collection of cable/cables from Railway store if required. | — | — | — | 26,550 | |
| — | 3.00 | — | — | ||
| Transportation of cables in rolls with or without wooden drums from the store of concerned SSEE. | — | — | — | 3,036.24 | |
| — | 300.00 | — | — | ||
| Cutting platform surface at an average depth & width of 300mmX300mm or as per site requirement in concreate floor/ pavement on platform and re-concreting after completion of works. | — | — | — | 1,44,000 | |
| — | 300.00 | — | — | ||
| "Supply of HDPE pipe of size 4 inch or more i.e 110 mm Diameter PE 100 to complete jOB. | — | — | — | 79,500 | |
| — | 300.00 | — | — | ||
| Erection and commissioning of HDPE pipe with all accessories to complete job. | — | — | — | 12,297 | |
| — | 15.00 | — | — | ||
| Supply of heavy duty Wall Mounted Fan WITH 5 STAR and above RATING 600 mm size , suitable for 230V, 50Hz, AC supply as per site requirement. | — | — | — | 1,65,750 | |
| — | 15.00 | — | — | ||
| Fixing and Commissioning of Wall Mounted Fan WITH 5 STAR and above RATING 600mm size with all accessories , as per site requirement . | — | — | — | 8,280 | |
| — | 160.00 | — | — | ||
| "Supply of 20W or higher wattage LED tube light with Batten ( integrated electronic driver).As per CEGE approved Specification for LED tube light-high power, 2100 Lumen output,220V, 50Hz AC with constant current driver with short circuit and overload protection etc. | — | — | — | 63,840 | |
| — | 160.00 | — | — | ||
| Fixing and Commisioning of any kind of Batten with 18W or higher wattage LED tube light with 02 nos. of stainless steel mounting clamp and screws for surface mounting of batten. | — | — | — | 6,163.2 | |
| — | 40.00 | — | — | ||
| "Supply of Inverter Based Back-up Emergency Batten with 20 W LED tube light (with constant current driver having short circuit and overload protection) with Length of LED Batten (Nominal)- 1150 mm (±5%), Operating Voltage range 140-270V, Rated Voltage 220-240 V, Input Frequency- 50Hz, Lamp efficacy 110 lm/Watt, LED chip efficacy 130 lm/Watt, Color temperature- 6500K (Cool White), Housing & Diffuser material made of polycarbonate with Inbuilt Driver having efficiency 85%, Color Rendering Index (CRI) 80, confirming ingress protection level of IP20, SMD based LED chip, Lumen Maintenance should be 80% after 6000 burning Hrs. as per LM 80, Power factor0.9, Surge voltage withstand capacity- 2.5KV, Life of LED should be minimum 50000 Hrs., Warranty for free replacement- 5yrs and 02 nos. of stainless steel mounting clamp and screws for surface mounting of batten with following certification on demand: 1) Availabilty of BIS CRS compliance as per IS 10322(Part 5 sec1 2012: latest. 2) Availability of Photo Biological Safety of LED as per IS:16108 /2012/IEC:62471:2006 3) ISO certification :9001:2015 4) LM79/80 report | — | — | — | 31,840 | |
| — | 40.00 | — | — | ||
| Fixing and Commisioning of any kind of Batten with 18W or higher wattage LED tube light with 02 nos. of stainless steel mounting clamp and screws for surface mounting of batten. | — | — | — | 1,540.8 | |
| — | 15.00 | — | — | ||
| "Supply of street light LED 60 watt or higher wattage street light as per Specification No. CEE/S/185/ LED/12/21/Rev-0, 2021 dated 22/12/2021 suitable for fixing in 42.4mm arm, including system lumen efficiency 110 lm/Watt (±5%), Power factor of luminary shall be0.90 at full load, The normal voltage of luminary shaIl be 230Volt AC ±5%V, 50HZ, The input oparating voltage of luminary shall be 140-270 Volt AC, Working temprature voltage should be -10 deq. C to 55 deg. C , The complete unit cubicle together with its mounting arrangement shall be subjected to shock testing as per latest iEC 61373, LED life expactency 50000 burning hrs,Colour temprature range 5500-6500 K, CRI 70 with driver featuring (Constant current driver with open & short circuit protaction, THD<10%, efficiency >85% (Minimum ), SPD for External surge protection-of minimum 10KV to be separately installed with the each fixture (As per ANSI C 136'2- 2014), Lamp shall be Distortion free, clear, heat resistance toughened glass of thickness 4.00 mm, polycarbonated lens Fire retardant FR grade,suitable for existing pole/universal with dedicated mounting kit /bracket, mounting of adjusted type, IP-66, The housing shall be single housing, side entry high pressure aluminium die casr/extruded aluminium, grey colour corrision-resistant polysterpowder coated with sepage optical and control gear compartments, high conductivity (LM/6/ADC12/LM24) with integral heat sink and heat proof silicon rubber, silicon gasket between housing & cover, impact resistance- IK-7, SMPS power supply. Cover to be fixed to the housing by mean of stainless steel screws and stainless steel fastener with supply of Pin Type Terminal End Lugs as per specification letter no. No: eFile Computer No: 255925 & 98667, dtd. 13/09/24 as per site requirement. 1) Unit shall with stand 300 volt AC for 1 minutes and cut off. It will automatically ON when voltage comes in oparating voltage range.Warranty for free replacement for 03 years. 2) Shall be oparated with reverse polarity for 3 minutes at maximum value of voltage range between supply terminal and body off the unit. 3) Shall be tested at 1500 volt AC for 1 minutes between supply terminals and body of the unit . | — | — | — | 50,994.9 | |
| — | 15.00 | — | — | ||
| Fixing and commissioning of LED 60 watt or higher wattage street light including wiring of light from loop box with proper termination by Pin Type Terminal End Lugs including fixing to the arm by mean of stainless steel screws and stainless steel fastener as per site requirenment, to complete the job. | — | — | — | 3,448.8 | |
| — | 60.00 | — | — | ||
| Fixing and commissioning of Brushless DC (BLDC) Motor Ceiling Fan, ISI marked, Sweep size: 1400 mm, suitable for 230V, 50Hz, AC supply confirming to Class:I of IS: 374/latest. Fixing of the fan shall be done with suitable clamp, hook, nut/bolts etc. and connection with flexible twin twisted multistrand Copper wire and removing of the existing old fan (if any) and handing over of the same to Railway Store with clear acknowledgement, as per site requirement. FAN will be supplied by Railway. | — | — | — | 7,608 | |
| — | 6.00 | — | — | ||
| "Supply of Propeller type AC Ventilating Fan (Exhaust Fan) of size 300mm, Capacitor type, Rated Voltage-240V, Frequency 50±2 Hz, Insulation material Class B, Motor Enclosure-Totally Enclosed Type, along with Guard and other Accessories such as Frame, Legs Set, Rubber Clamps & Other Hardware etc, Conforming to IS 2312- 1967 with all amendments (Reaffirmed 2020) and ISI mark .Cost includes Suitable size of Stainless steel fastener, screw, nuts, bolts ,washer etc as per site requirenment. | — | — | — | 13,872 | |
| — | 6.00 | — | — | ||
| Fixing and commissioning of Heavy Duty Exhaust Fans with Stainless steel fastener, screw, nuts, bolts, washer etc. as per site requirenment. | — | — | — | 930.84 | |
| — | 8.00 | — | — | ||
| "Supply of SP&N 12-way DB (SD) Thermoplastic Circuit breaker boxes IP 65 (with metric knockouts for cable entry)consisting with DP 32A 10kA MCB-1 no as incoming and SP 20 A,10kA MCB - 4 nos, SP 16 A,10kA MCB - 4 nos, as outgoing with Neutral links and Earth bar etc., | — | — | — | 93,825.6 | |
| — | 8.00 | — | — | ||
| Fixing and Commisioning of SP&N 12-way DB (SD) Thermoplastic Circuit breaker boxes IP 65 (with metric knockouts for cable entry)consisting with DP 32A 10kA MCB-1 no as incoming and SP 20 A,10kA MCB - 4 nos, SP 16 A,10kA MCB - 4 nos, as outgoing with Neutral links and Earth bar etc., | — | — | — | 3,412.24 | |
| — | 10.00 | — | — | ||
| "Supply of TP&N 6-way DB (DD) consisting with FP 63A 10kA MCB-1 no as incoming and 20A 10kA SP MCB-8 Nos, 16A 10kA SP MCB-8 Nos as outgoingwith Cu.bus-bar, Neutral links , Spreader Link, Earth bar and DinRail etc.,(ALL MCB will be C series.Thickness of material (in mm) 1.6 mm (MSsheet) | — | — | — | 86,090 | |
| — | 10.00 | — | — | ||
| Fixing and Commisioning of TP&N 6-way DB (DD) consisting with FP 63A 10kA MCB-1 no as incoming and 20A 10kA SP MCB-8 Nos, 16A 10kA SP MCB-8 Nos as outgoingwith Cu.bus-bar, Neutral links , Spreader Link, Earth bar and DinRail etc., with complete wiring and accessories to complete job. | — | — | — | 5,752.9 | |
| — | 20.00 | — | — | ||
| Supply of solar street light(30 watt) with pole height 6 m .Type of LED (Light source) 30 Watt White LED type LED chip Efficacy (Lumen/watt) 135, Luminaire System Efficacy - Lumen output - (Lumen/watt) 120, The color temperature of white LEDs used in the system 5500 degree K - 6500 degree K. The temperature of heat sink 20 degree centigrade above ambient temperature during operation CRI > 70 %, Lighting quality Free from glare, flickering and UV. Type of Battery Lithium Ferro Phosphate battery (LiFePo4). Operating from dusk to dawn first four hour full brightness, rest of the time at lower level, with motion sensor Battery capacity 12.8 V (nominal), 30 Ah at STC (1 day autonomy), IP 65 or more, Pole height 6 m . Nominal bore size of tube / Thickness of tube 65 mm / 3.6 mm or more, Conformity of the specification for Steel tube for street light pole as per IS:1161:2014 latest. Test certificate from MNRE/ NABL accredited labs to be provided. Make: Eveready, Philips, any IS approved | — | — | — | 8,26,000 | |
| — | 20.00 | — | — | ||
| Supply of 4M HDG(Hot Dip Galvanized) Octagonal Pole with single arm brackets and 01 quantity LED street light 45watt, IP67 and IK 07 with isi mark, top dia 70mm,bottom dia 130mm,sheet thickness 3mm,base plate dimensions(L X B X T)-200x200x12mmwith foundation bolts and single arm 1000mm long special brackets. The door opening of the pole should be reinforced, water proofed & with locking arrangement & arrangement of in build junction box with DP MCBs 16 A-1 No , to be placed on a din channel of Pole and supply and fixing of Terminal connector, connection of terminals with lugs, earthing at the suitable location of the pole. | — | — | — | 2,31,972.8 | |
| — | 10.00 | — | — | ||
| Erection, Fixing and Commisioning of 4M HDG(Hot Dip Galvanized) Octagonal Pole ,top dia 70mm,bottom dia 130mm,sheet thickness 3mm,base plate dimensions(L X B X T)- 200mmX200mm X12mm or higher with foundation bolts and single/double arm, 1000mm long special brackets, junction box and with concretting the foundation / plith including sand, ballast, cement & metalic tuisted rod etc.of size 750mmx750mm at bottom and 500mmX500mm at top or as per site rquirement with height 1500mm in the ratio 1:3:6 ( the rate shall be inclusive of all materials ) with necessary cable arrangement for lighting fixture with single arm brackets including transportation of pole to site location. | — | — | — | 49,675.5 | |
| — | 4.00 | — | — | ||
| Supply, of LED High Bay light fittings 200W LED, LED chip Efficacy (Lumen/watt) 130, Luminaire System Efficacy - Lumen output - (Lumen/watt) 120, 6000 K IP-65, IK 07. Accessories for each luminaire: Metallic adjustable Brackets (Stainless steel),SS Eye Bolts (as per IS:4190:1984 latest),Set of Bolt,Nut, Washers (SS),Die cast aluminium brackets etc. ISI Marked 3 Core cable for input power ( min Length:250 mm ).Test report from NABL lab to be submittedWarranty period (in Months) 36 or more. | — | — | — | 1,24,000 | |
| — | 4.00 | — | — | ||
| Fixing and commissioning of 180/200 W LED Flood light energy efficient enviornment friendly including wiring of light and suitable accessories for fixing. | — | — | — | 1,360.44 | |
| — | 2.00 | — | — | ||
| " Supply, testing of LT Panel consist of 1 No. 125 Amp 36 kA FP MCCB as a incoming , 02 Nos 63 Amp FP MCCB as a outgoing and 32A DP MCB -7 Nos. as a outgoing with cable termination." | — | — | — | 66,068.2 | |
| — | 2.00 | — | — | ||
| Fixing and Commissioning of LT Panel with all required accessories. | — | — | — | 7,100.76 | |
| — | 20.00 | — | — | ||
| Supply of Cable loop Box(Of fiber body) for 3 phase incoming & outgoing connection consists of 3 phase &neutral terminal &15 A K-fuse as per relevant ISS, with suitable bridge arrangement of size 240mm x 140 mmx 100mm, fitting shall be made with necessary arrangement as per site requirement, cables are to be terminated withproper socking arrangement to complete job. | — | — | — | 19,019.8 | |
| — | 20.00 | — | — | ||
| "Fixing and commissioning of POLYCARBONATE make fire retardent Cable loop box ( of fibre body), IP 66 Fixing shall be made with necessary arrangements as per site requirement, cables are to be terminated with proper socketing arrangement to complete job. | — | — | — | 1,902 | |
| — | 10.00 | — | — | ||
| Supply of Earthing arrangement with supply of Hot Dip Galvanized (HDG) earth cone and all other requisite materials as per CEE/GRC's Drg. No.CEE/G/A3/P-150, Alt.1 including sump box with salt and charcoal, metalic cover etc. as per site supervisor's instruction. Cost includes supply of all materials mentioned in the Drawing including 02 mtrs 25x5mm GI strip for connection from earth electrod pipe to light pole /Rail pole etc.Make: Any IS standard Indian make. | — | — | — | 43,366.5 | |
| — | 10.00 | — | — | ||
| Erection of Earthing arrangement with erection of Hot Dip Galvanized (HDG) earth cone and all other requisite materials as per CEE/GRC's Drg. No.CEE/G/A3/P-150, Alt.1 including sump box with salt and charcoal, metalic cover etc. as per site supervisor's instruction. Cost includes erection of all materials mentioned in the Drawing including 02 mtrs 25x5mm GI strip for connection from earth electrod pipe to light pole /Rail pole etc. | — | — | — | 10,462.1 | |
| — | 250.00 | — | — | ||
| Supply o f Hot dipped Galvanized wire mesh cable trays size: 54mm/200mm with coupling kit and other accessories. It shall be manufactured with a longitudinal 'T- welded' safety edge All Accessories including couplers , mounting accessories (Mechanically tested & supplied by cable tray manufacturer must be used) are required of same finish as per site requirement. Trays should comply Standard EN ISO 14 61: at least 550 h of SST. The deflection of cable tray must be no more than 1/200th of the distance between two supports and tested in accordance with the standard IEC 61537. Wire-mesh cable trays must be designed with an optimum span of 1.5 m, considering the maximum carrying capacity authorized by the manufacturer. Assemblies with specific fire resistant properties must have an E30-E90 certificate. Rod-dia must be from 3.9mm to5.9mm for different sizes. | — | — | — | 3,77,600 | |
| — | 250.00 | — | — | ||
| Fixing and commissioning of Hot dipped Galvanized wire mesh cable trays size: 54mm/200mm with coupling kit and other accessories. | — | — | — | 14,195 | |
| — | 6.00 | — | — | ||
| Supply of LED Board with sequential timer to lit the name in 3 languages i.e English, Hindi and Local of size 2' X2' made out of 1.8mm thick Aluminium Sheet with through hole LED having IP 66 protection along with power supply for fixing on structure(3 dimentional letter made of Acrylic sheet of letter size as per site requirement and direction of consignee) . As per specification No. RDSO/PE/SPEC/PS/0123(Rev. 0)2009. | — | — | — | 38,767.26 | |
| — | 6.00 | — | — | ||
| Fixing and Commissioning of LED Board with sequential timer to lit the name in 3 languages i.e English, Hindi and Local of size 2' X2' made out of 1.8mm thick Aluminium Sheet with through hole LED having IP 66 protection along with power supply for fixing on structure(3 dimentional letter made of Acrylic sheet of letter size as per site requirement and direction of consignee) . As per specification No. RDSO/PE/SPEC/PS/0123(Rev. 0)2009. | — | — | — | 2,103.48 | |
| — | 6.00 | — | — | ||
| Supply of Sign Board written either in Hindi or English or local language with 24" letter height back lit by LEDs with minimum life of 80000 burning hours to give visibility in day time as well as night time fixed on board size 6'X2 1/2'.The 3 dimensional letter of depth 2inches and size as per site requirement and direction of consignee is made of 2mm, White Acrylic and is pasted on the blue Colour ACP Sheet of 20SWG along with power supply for fixing on structure. As per specification No. RDSO/PE/SPEC/PS/0123(Rev. 0)2009.having IP 66 protection.Extra fittings as per site requirement. | — | — | — | 1,44,906.3 | |
| — | 6.00 | — | — | ||
| Fixing and Commissioning of written either in Hindi or English or local language with 24" letter height back lit by LEDs with minimum life of 80000 burning hours to give visibility in day time as well as night time fixed on board size 6'X2 1/2'. | — | — | — | 8,160 | |
| — | 10.00 | — | — | ||
| " Supply and installation/ provision of mobile charging unit made of MS sheet CRCA 1.2mm thickness, IP 20protection, 10 tank powder coating process 360(H) 260 (W) 100 (D) with 4 nos charging socket and 2 nos USB 1 module controling 6A optipro MCBs cat ref 811122 switch for every charging point and 6A including suitable curved mobile holding tray of size 250 x 150mm and 4 nos mobile holding pocket with fixing arrangements and required stickers and logo pasted. MCB PROTECTION AND USB PORT TO BE PROVIDED. | — | — | — | 65,962 | |
| — | 560.00 | — | — | ||
| Supply of Trunking batten light, length- 3.6 mtr Trunk (12ft) with 03 fitting, 34 watt or more, 5000 lumen,( 4ft x3) Extruded Aluminum IP54 Trunking with 50k hours Life class & 160 lm/w system efficacy in 6500k, CRI>=80, SDCM<5,min , comprises of Extruded aluminium housing with engg. Plastic end caps.Diffuser: Extruded PC Opal diffuser fixed to the housing and supported by end caps. Trunking compartment: Extruded aluminium housing with egg.Plastic end caps.LEDs mounted on FR4 PCB and connected in series and parallel combination.Driver: Flicker free, Constant current LED driver.Mounting Type: Surface /suspended mounting. Standard: IEC 62384,IEC 61347-2- 13,iec 61547, Type test report from NABL accredited Lab to be provided. LM 79, LM 80 test report to be submitted. | — | — | — | 1,52,32,000 | |
| — | 560.00 | — | — | ||
| Fixing and Commisioning of Trunking batten light with all required accessories and wiring as per site requirement. (length- 3.6 mtr Trunk (12ftwith 03 fitting,) , 34 watt or more,5000 lumen,( 4ft x3) Extruded Aluminum IP54 Trunking with 50k hours Life class & 160 lm/w system efficacy in 6500k, CRI>=80, SDCM<5,min , comprises of Extruded aluminium housing with engg. Plastic end caps.Diffuser: Extruded PC Opal diffuser fixed to the housing and supported by end caps. Trunking compartment: Extruded aluminium housing with egg.Plastic end caps.LEDs mounted on FR4 PCB and connected in series and parallel combination.Driver: Flicker free, Constant current LED driver.Mounting Type: Surface /suspended mounting. Standard: IEC 62384,IEC 61347-2-13,IEC 61547, Type test report from NABL accredited Lab to be provided. LM 79, LM 80 test report to be submitted | — | — | — | 21,571.2 | |
| — | 160.00 | — | — | ||
| Supply of Trunking batten light with channels and required accessories, length- 1.2mtr Trunk (4ft x 1)with 01 fitting, , 34 watt or more,5000 lumen, 4ft Extruded Aluminum IP54 Trunking with 50k hours Life class & 160 lm/w system efficacy in 6500k, CRI>=80, SDCM<5,min , comprises of Extruded aluminium housing with engg. Plastic end caps.Diffuser: Extruded PC Opal diffuser fixed to the housing and supported by end caps. Trunking compartment: Extruded aluminium housing with egg.Plastic end caps.LEDs mounted on FR4 PCB and connected in series and parallel combination.Driver: Flicker free, Constant current LED driver.Mounting Type: Surface /suspended mounting. Standard: IEC 62384,IEC 61347-2-13,iec 61547, Type test report from NABL accredited Lab to be provided. LM 79, LM 80 test report to be submitted. | — | — | — | 15,20,000 | |
| — | 160.00 | — | — | ||
| Fixing and Commisioning of Trunking batten light with all required accessoriesand wiring as per site requirement. 1.2mtr Trunk (4ft x 1with 01 fitting), 34 watt or more,5000 lumen, 4ft Extruded Aluminum IP54 Trunking with 50k hours Life class & 160 lm/w system efficacy in 6500k, CRI>=80, SDCM<5,min , comprises of Extruded aluminium housing with engg. Plastic end caps.Diffuser: Extruded PC Opal diffuser fixed to the housing and supported by end caps. Trunking compartment: Extruded aluminium housing with egg.Plastic end caps.LEDs mounted on FR4 PCB and connected in series and parallel combination.Driver: Flicker free, Constant current LED driver.Mounting Type: Surface /suspended mounting. Standard: IEC 62384,IEC 61347-2-13,IEC 61547, Type test report from NABL accredited Lab to be provided. LM 79, LM 80 test report to be submitted | — | — | — | 6,163.2 | |
| — | 50.00 | — | — | ||
| Design, manufacture, display of wall /hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceilingmounting, pole mounting or floor mounting and as per site requirement.The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. | — | — | — | 82,046.68 | |
| — | 50.00 | — | — | ||
| Erection and installation of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement.The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. | — | — | — | 8,204.53 | |
| — | 20.00 | — | — | ||
| Dismantlling / Shifting of Rail Pole/SST pole/GI/MS Structure/Location box/Control Panels etc with gas cutting or any other means without appreciable damage. | — | — | — | 4,408.4 | |
| — | 2.00 | — | — | ||
| "Supply of LADDERS Aluminium Platform step ladder of total extended height of 15 feet, Fully extended Height (in feet) -15, Retracted form Height (in feet) -3 Platform Size (Length x Width) 300 mm x 250 mm .Material -Aluminium,Minimum Load Capacity (in kg.)- 140,Feature -Anti skid rubber feet,Weather resistant,Anti skid step" | — | — | — | 50,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
1.0-explantorynoteadlbva30-03-2026mod.pdf
CORRIGENDUM
1.0-explantorynoteadlbva20-03-2026.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .