Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹15.5 L+₹1.2 L (8.44%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹15.6 L+₹1.3 L (8.87%)Rejected-Finance 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE KALIMATA MANDIR ROAD PATHANKOT PUNJAB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹16.3 L+₹2.0 L (13.8%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹17.9 L+₹3.6 L (25.2%)Rejected-Finance NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance BEING L5 |
Tender Value
Refer Docs
EMD Value
₹16,920
Closing Date
22 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF UDHAMPUR
GE AF UDHAMPUR
PROVISION OF 10 KVA INSULATION TRANSFORMER (QTY -01) AT RT CABIN, 30 KVA INSULATION TRANSFORMER SET 718 SU (QTY-01) DEHUMIDIFIER AND ALL WEATHER 1.5 TON AC (QTY-01) AND 7.5 KVA UPS (QTY-02) AT AF STN NATHATOP
2022_MES_516116_1
GE/AFU-57/2021-22
Open Tender
Civil Works
Item Rate
270 days
NATHATOP
AS PER NIT AND TENDER
8 documents required · 8 mandatory
₹500
Yes
GE AF UDHAMPUR
₹16,920
Yes
18 Aug 2022
27 May 2022
24 Jun 2022
27 May 2022
22 Jun 2022
10 Jun 2022
7 Jun 2022 - 14 Jun 2022
60 days
Amount
Supply and fixing of 10 KVA isolation transformer 230 volts single phase input single phase output, 25 Amps with copper winding all including plinth/necessary civil work as per site required complete all as specified and as directed.
Supply and fixing of 32 Amps three phase 2 pole MCB with enclosure complete all as specified and as directed
Supply and fixing of 06 Sqmm 5 core copper flexible cable including pvc conduit pipe clips nails ,clamps etc as per site requirement complete all as specified and as directed
Supply and fixing of 30 KVA isolation transformer 415 volts three phase input three phase output, 41.7 Amps with copper winding all including plinth/ necessary civil work as per site complete all as specified and as directed.
Supply and fixing of 63 Amps three phase 4 pole MCB enclosure complete all as specified and as directed
Supply and fixing of 10 Sqmm 5 core copper flexible cable including pvc conduit pipe clips nails ,clamps etc as per site requirement complete all as specified and as directed
Supply and laying of 35 Sqmm aluminium XLPE cable 3.5 core PVC Conduit heavey duty including clips ,nail clamps lugs and assesories as required after site visit (Cable thimbble, gland etc) all as specified and as directed
Supply and laying of 50 Sqmm aluminium XLPE cable 3.5 core including pvc heavey duty conduit pipe clips nail clamps lug and assesories as required after site visit (Cable thimbble, gland etc) all as specified and as directed
Supply and fixing of vertical three phase distribution board,4 Way TPN,DB VTPN DPX 160 MCCB DBs IEC 61439-3 IP 30-IK 08 507740 Suitable for flush mounting ans surface mounting with 250 A Copper Busbar for each phase with 2 Neutral bar 2 Earthbar and cable hes for improved Pan Assambaly for ease of instalation prefitted masking sheet Reversible Door for IP43 & 54 DBs with provisiong as incomer and SP/TP MCBs as Outgoing complete all fixing of wall and making good condition including brick work complete all as specified and as directed.
Supply and fixing of vertical three phase distribution board,4 Way TPN,DB VTPN DPX 160 MCCB DBs IEC 61439-3 IP 30-IK 08 507740 Suitable for flush mounting ans surface mounting with 250 A Copper Busbar for each phase with 2 Neutral bar 2 Earthbar and cable hes for improved Pan Assambaly for ease of instalation prefitted masking sheet Reversible Door for IP43 & 54 DBs with provisiong as incomer and SP/TP MCBs as Outgoing complete all fixing of wall and making good condition including brick work complete all as specified and as directed.
Supply and fix chemical temp dehumidifier continuous operating complete, with heaters, ducting, electrical connection for 360 Cfm capacity Compliying EN ICO 12100-1-2003 EN ISO-12100-2-2003, EN 60204-1: 2006+A1 2009 9001: 2000 and ISO-14001 certified dehumidifuer and plastics drying and auxiliaries manufacturing company in the world of following technical details :- (i) Model FFB 600 having capacity of 360 CFM (ii) Diffrent air pressure switch for providing react air flow. (iii) High temprature safety thermostat cutout. (iv) Reactivation cool down safety device.(vii) (v) Electrical interlocking of fan motors, heaters and rotor drive. (vi) PTFE bonded bulb seal design, miniminzed air leakage. (vii) Serval Mounting and instalation options small footprints low volume/weight per CMH (VIII) Humidity control through humidstart on /off stainless steel construction Microprocesser controller. (ix) Process and reactivation air flow sectors are insulated Note : Necesary ducting work all including material deemed to be coated rates instalation shall be done as Per Model FFB 360 bry Air Dehumidifier and Equivalent
M&L Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC conduit pipe copper conductor, single core cable in surface/recessed as required 2x4.0 Sqmm + 1x4.0 Sqmm earth wire complete all as specified and as directed.
MCB distribution board having IP-54 protection, powder coated, double door, flush mounted complete with locking arrangement suitable for 4 way SPN with 200 Amp rated bus bar 203 volt AC supply from site complete all as specified and as directed.
M&L point wiring alongwith earth wire with the following sizes of FR is PVC conduit pipe copper conductor, single core cable in surface/recessed as required 2x4.0 Sqmm + 1x4.0 Sqmm earth wire complete all as specified and as directed.
M& L of sheet metal encloser foe DBs single door SPN 2way 240 Volts complete all as specified and as direcetd.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning of capacity of 32 Amps complete all as specified and as directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning of capacity of 32 Amps complete all as specified and as directed.
Supply and fix air cooled split unit invertor type hot and cold wound all weather type air conditioner for cooling and heating electric driven, single phase of capacity of 1.5 Ton, as shown the same to the entire satisfaction of Engr-in-Charge, all as directed.
M&L Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in pvc conduit pipe including clips nail etc as per site requirement complete all as required 2x4.0 Sqmm + 1x4 Sqmm earth wire complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 03 KVA intelli micreochip based design intelli auto start silicon based transitors silver caked Relays intelli Thermal Manangement Low & High cut for protetion used for mains under volt protection over volt protetion mounting of wall complete all as specified and as directed.
Instalation charges complete 10 KVA isolation transformer as per site and connected assecories complete all as specified and as directed.
Supervision of erection & commissing charges complete 360 CFM dehumidifier as per site and connected assecories complete all as specified and as directed.
Instalation charges complete 30 KVA isolation transformer as per site and connected assecories complete all as specified and as directed.
Supply and installation of single phase UPS 7.5 KVA and other connected items as under below:- 7.5 KVA (1P/1P) online UPS sytem Finch PW model 1. True Double Online Conversion 2. Microprocessor Control optimizes reliability 3. Input power factor correction 4. Wide input voltage (110V-300V) 5. Converter Mode available 6. Generator Compatible 7.Adjutable Battery Number only available 8. Smart SNMP works well with either USB or RS 232 are optional 9. Comprehensive display allows easy monitoring and access of UPS status With SMF 12V /26AH, 20 Nos. batteries (Exide or Quanta/ HBL make for 30 Min. backup & its accessories (inter connectors, stand, Batt. to UPS cable -5 Meters each positive & negative wires) each UPS.
Supply and laying of 50 sqmm aluminium XLPE cable 3.5 core including lug and accessories as required after site visit (Cable , thimbble, gland etc. ) all as specified and as directed.
Supply and fixing of vertical three phase distribution board, TPN, 4 way 440 volts having IP-30 IK 08 MODEL NO 5077 20 protection, double door with provinsion for fixing of MCCBs as incomer and MCBs as outgoing complete after taking down existing unservicable main switch, busbar, GI box including accessories thereing & disposing from site complete all as specified and as directed.
Suply and fixing of MCCB 3 pole, 415 V, adjutable type, 25 to 100 Amps with breaking capacity 36 KA as per existing MCB suitable of size with connected accessories etc. complete all as specified and as directied.
CHIME ELECTRONICS
JCC ENGINEERS PRIVATE LIMITED
SATYA SALES AND BUILDERS
CITY TOP ELECTRICAL WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .