| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance C 577B IST FLOOR RIGHT SIDE MAHAVIR ENCLAVAR PART III C 577B IST FLOOR RIGHT SIDE MAHAVIR ENCLAVAR PART III STREET NO 46 UTTAM NAGAR WEST DELHI DELHI 110059 UTTAM NAGAR DELHI DELHI 110059 UDYAM DL 10 0020241 07AIIPJ6248B1ZF B B R B | WEST DELHI | DELHI | 110059 | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical Incomplete Documents |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Jan 2023, 11:30 amClosed
Principal Hansraj College
Hansraj College, University of Delhi
As per tender
2022_DU_731632_1
HRC/Pur/Tender/2022-23/02
Open Tender
Plant Protection Input/Equipment Works
Works
30 days
Hansraj College
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Principal Hansraj College
₹60,000
31 May 2023
28 Dec 2022
20 Jan 2023
28 Dec 2022
19 Jan 2023
28 Dec 2022
Amount
Real Time PCR (Details can be checked through tender document)
Refrigerated Microcentrifuge: (Details can be checked through tender document)
Microplate Centrifuge (Details can be checked through tender document)
1. System should have Brushless DC motor for maintenance free long life. 2. System must have the capacity of 2 microplates :96 & 384 well (PCR/ Deep well) & compatible with all types of PCR plates. 3. System must have Microprocessor controlled centrifuge with variable speed and time setting 1-999 min & infinity mode along with last run memory function & we can save and run upto 99 defined programs (protocols) 4. System must have minimum Precise RPM setting from 500 to 2200 RPM or above with an accuracy of ±10 RPM 5. System dimensions should not more than LXWXH (mm) 415 x 355 x 173 6. System must have automatic imbalance detection for safe operation 7. System must have features of Lid lock safety (Automatic lid release after run completion) 8. System must have digital display. 9. Compact design with low loading height for ease of operation 10. System must have minimum one year warranty. 11. System must have one touch short spin operation & change over from RPM to RCF
Minus 20 Deg C (Details can be checked through tender document)
1. Temperature Range should be -17 to -24 degree C. 2. Capacity should be 140-150 Ltr 3. System dimensions should not more than WXDXH(INCH)21 X 22 X 45 4. System must have an option of manual defrost and rated load should be 120-130W 5. System should have 5 pull out drawers. 6. System should have solid door 7. REFRIGERENT should be R134a 8. System should have visual & Acoustic Alarm 9. System should be CE certified 10. System should have Super-Freeze Function & reversible door. 11. system should have an option for good lightning and transparent drawers and flaps maximise the visibility the product 12. Warranty should be standard as per principal norms. 13. Must be supplied with compatible stablizer for better performance of the instrument.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .