Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC | ₹29.0 L Quoted ₹30.4 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹34.9 L+₹4.5 L (14.7%)Rejected-Finance CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | ₹34.9 L+₹4.5 L (14.7%) | L2 | Rejected-Finance Other than Lowest |
| 3 | L3₹35.0 L+₹4.6 L (15.2%)Rejected-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | ₹35.0 L+₹4.6 L (15.2%) | L3 | Rejected-Finance Other than Lowest |
| 4 | L4₹36.5 L+₹6.1 L (20.1%)Rejected-Finance C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | ₹36.5 L+₹6.1 L (20.1%) | L4 | Rejected-Finance Other than Lowest |
| 5 | L5₹40.5 L+₹10.0 L (33.0%)Rejected-Finance | ₹40.5 L+₹10.0 L (33.0%) | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Mar 2024, 6:00 pmClosed
CWE (A) Jaisalmer
HQ CWE (A) JAISALMER-345001
REPAIR AND MAINT OF INTERNAL WIRING E/M FITTINGS AND FIXTURES OF CERTAIN UNITS OF 4 (I) BDE UNDER GE(A) JAISALMER
2024_MES_641257_1
84170/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (A) Jaisalmer
₹96,000
Yes
23 Mar 2024
7 Feb 2024
6 Mar 2024
7 Feb 2024
4 Mar 2024
21 Feb 2024
7 Feb 2024 - 12 Feb 2024
Amount
Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including PVC Casing Capping/conduit, fixture and fitting such as switches, ceiling roses, pendents, regulators, sockets , light fitting etc removing materials for taking credit and making good disturbed surface of walls,floors etc complete all as specified & directed by Engineer-in-charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-charge.
Taking down the existing unserviceable MCBs/MCCBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-charge.
M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area , single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and inciuding medium grade, PVC casing caping/surface conduit and accessories on wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box thickness as per IS standard (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally. and two coats of black bituminous paint over a coat of red oxide primer externally,covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for the followigs :-
All as per Item No 4.00 here-in-before but for One light or fan point, controlled by one, one way switch 5 Amps.
All as per Item No 4.00 here-in-before but for one bell/buzzer point controlled by one push botton.
All as per Item No 4.00 here-in-before but for one socket out let 3 pin 5 Amps on the same board.
All as per Item No 4.00 here-in-before but for one light point controlled by two, 2 way switches.
All as per Item No 4.00 here-in-before but for one socket outlet of 3 pin 5 Amp on independent board.
All as per Item No 4.00 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified and directed by Engineer-in-charge
M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No. and existing PVC Concealed conduit of 20 mm bore with accessories in wall floor etc with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for the following :-
All as per Item No 6.00 here-in-before but for One light or fan point, controlled by one, one way switch 5 Amps.
All as per Item No 6.00 here-in-before but for one bell/buzzer point controlled by one push botton.
All as per Item No 6.00 here-in-before but for one socket out let 3 pin 5 Amps on the same board.
All as per Item No 6.00 here-in-before but for one socket outlet of 3 pin 5 Amp on independent board.
All as per Item No 6.00 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified and directed by Engineer-in-charge.
S&F of switch piano, flush type, 5 amps, 230 volts, single pole, one way (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F of switch piano, flush type, 15 amps, 230 volts, single pole, one way (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F of switch piano, flush type, 5 amps, 230 volts, single pole, two way (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F of sockets outlet multipurpose 2 in 1, 5 Amps flush type confirming to IS complete all as specified and directed by Engineer-in-charge.
S&F of sockets outlet multipurpose 2 in 1 pin, 5 and 15 Amps flush type confirming to IS complete all as specified and directed by Engineer-in-charge.
S&F of ceiling rose, PVC of size 65 mm x 18 mm two to three terminals (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F of bell push flush type 5 Amps complete all as specified and directed by Engineer-in-charge.
S&F of stepped type, electronic fan regulator on the existing phenolic laminated sheet etc as required complete all as specified and directed by Engineer-in-charge.
M&L Point wiring used approved colour coding as per IS (Red, Black and Green) for single phase circuits), with multi-stranded copper conductor 1.5 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLS cable 1100 volts grade, ISI 694 marked with valid CML No. and existing PVC Concealed conduit of 20 mm bore including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for condits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc PVC insulated multistanded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for the following :- Note : Modular switch and socket shall be measured and paid separately.
All as per Item No 16.00 here-in-before but for One light or fan point, controlled by one, one way switch 5 Amps.
All as per Item No 16.00 here-in-before but for one bell/buzzer point controlled by one push botton.
All as per Item No. 16.00 here-in-before but for one light point controlled by two, 2 way switches.
All as per Item No 16.00 here-in-before but for one socket out let 3 pin 5 Amps on the same board.
All as per Item No. 16.00 here-in-before but for one socket outlet of 3 pin 5 Amp on independent board.
All as per Item No 16.00 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified and directed by Engineer-in-charge.
Supply & fix flat mechanical switch motion technolgy having some position whether on or off made out of corrosion resistant heat resistant and impact resistant polycorbonate electric are encapulated modular switches complete all as specified and directed by Engineer-in-charge of following :-
All as per Item No 18.00 here-in-before but 1 way 6 Amp Switch
All as per Item No 18.00 here-in-before but 2 way 6 Amp Switch
All as per Item No 18.00 here-in-before but 1 way 16 Amp Switch,
All as per Item No 18.00 here-in-before but 6 A Bell push switch
Supply & Fix flat mechanical switch motion technolgy having same position whether on or off made out of corrosion resistant heat resistant and impact resistant polycorbonate electric are encapulated modular sockets complete all as specified and directed by Engineer-in-charge of followings :-
All as per Item No 19.00 here-in-before but 6 Amp 3 Pin socket outlet with shutter
All as per Item No 19.00 here-in-before but 6 Amp/16 Amp 3 Pin socket outlet with shutter,
All as per Item No 19.00 here-in-before but Modular Fan regulator (5 speed),
M&L in repair of lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings including taking down unserviceable lamp holder of any description complete all as specified and directed by Engineer-in-charge.
S&F in repair of bell AC single pole Ding Dong type 230 volt complete all as specified and directed by Engineer-in-charge.
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 4.0 Sq mm (FRLS) including PVC casing & capping non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 4.0 Sq mm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. NOTE:- Two runs of 4.0 sqmm cable & One run of 4.0 sqmm cable and One run of PVC casing & capping shall be paid as one unit length
M & L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 4.0 Sqmm (FRLS) existing concealed/Surface conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 4.0 Sqmm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. NOTE :- Two runs of 4.0 Sqmm cable & One run of 4.0 Sqmm cable shall be paid as one unit length
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sq mm (FRLS) in and including PVC casing & capping non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sq mm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. NOTE: Two runs of 6.0 sqmm cable & One run of 6.0 sqmm cable and One run of PVC casing & capping shall be paid as one unit length
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sqmm (FRLS) in existing concealed /surface conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sqmm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. NOTE :- Two runs of 6.0 Sqmm cable & One run of 6.0 Sqmm cable shall be paid as one unit length
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 10.0 Sq mm (FRLS) including PVC conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 10.0 Sq mm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. NOTE :- Two runs of 10.0 sqmm cable & One run of 10.0 sqmm cable and One run of PVC casing & capping shall be paid as one unit length
wall cutting channels grooves or rebates n exc 15 cm girth and trimming surface and including pvc conduit pipe isi marks nominal cross section size including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge.
Supply and fixing of LED box type Integrated Batten Wattage 20 watt having Aluminum Extruded housing in white powder coated Finish with high translucent PC Cover, Dimension of the Fixture Must not be less Then Length 1170 MM (± 5 MM ), Elegant Design, IP 20 Protection. Minimum Lumens output of the fitting shall be 2500 Lumens With Efficacy of 125 lm/W, CCT 5700 – 6500K, Surge Protector 4 KV, PF>= 0.95 , Necessary mounting arrangements. The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with Lm-79 / LM-80 / Test Report complete all as specified and directed by Engineer-in-charge.
Supply and fixing of LED box type Integrated Batten Wattage 20 Watt having Aluminum Extruded housing in white powder coated Finish with high translucent PC Cover, Dimension of the Fixture Must not be less Then Length 1130 MM (± 5 MM ),WARM WHITE Color, Elegant Design, IP 20 Protection. CCT 2700 – 3000k, Surge Protector 4 KV, PF>= 0.95 , Necessary mounting arrangements. The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM-80 / Test Report complete all as specified and directed by Engineer-in-charge.
Supply and fixing of LED box type Integrated Batten 40 watt having Aluminum Extruded housing in white powder coated Finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Dimensions of the Fitting Shall be Not less then 1200 MM ( Length) X 40 MM ( Width ) X 63 MM ( Height ). Lumens output of the fitting shall be not less then 4400 lm, CCT 5700 – 6500K, buring hours 50,000 Surge Protector 4 KV, PF>= 0.95 , Separate detachable type Electronic constant current drivers for easy replacement and maintenance, THD < 10% , Necessary mounting arrangements .The fixture shall be suitable for wall mounting /suspension mounting as per site requirement . The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM80 / Test Report complete all as specified and directed by Engineer-in-charge.
S & F for LED tube light fitting 10 Watt, 2 Feet or 591 MM in length, IP 20 Protection, wall mounted type, Slim LED Batten with extruded aluminium housing and polycarbonate diffuser, elegant design with end caps, having excellent thermally managed polycarbonate extrution, LM 80 Certified LED having Integral Electronic Constant Current Driver, IP 20 Protection, Opreating voltage 240 V , 50Hz AC Supply and Operating tempraeture 0 to 50 C, Power factor ≥ 0.9, Lumen output ≥ 1000, necessary mounting arrangements on PVC Square box 2 Nos, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified and directed by Engineer-in-charge.
Supply and fixing of recessed/ceiling mounted down lighter with CRCA housing with high bright LED,idealy suited for low ceiling areas Brilliance 36watt LED, size 2ft x 2ft The product features color tuning from CCT 5700K – 6000 k, Surge Protector 4 KV, PF>= 0.95 , necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified and directed by Engineer-in-charge.
Supply and fixing of recessed/ceiling mounted down lighter with CRCA housing with high bright LED,idealy suited for low ceiling areas Brilliance 36watt LED, size 2ft x 2ft The product features color tuning from CCT 2700 – 3000k, Surge Protector 4 KV, PF>= 0.95 , necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified and directed by Engineer-in-charge.
S & F for Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and including of LED bulb 15 watts complete all as specified and directed by Engineer-in-charge.
S & F in repair recess mounted/Surface mounted/POP mounted or as per site requirement LED down light 06 Watt round/Square in shape worm white or 2700 K- 3000 K as per user requirement Ideal for wardobes, furniture lighting, display & interior decoration of complete all as specified and directed by Engineer-in-charge.
S & F in repair for LED down lightrecess mounted/Surface mounted/POP mounted or as per site requirement, square/Round type worm white / Neutral white or 2700 K- 3000 K as per user requirement 18 watts with efficiency of 100 lumens per watt, in worm white/ neutral white as per site requirement sleek design aluminium housing polycarbonate diffuser white finish operating voltage from ceiling rose to fitting complete all as specified and directed by Engineer-in-charge.
S & F in repair for LED down lightrecess mounted/Surface mounted/POP mounted or as per site requirement, square/Round type worm white / Neutral white or 5600 K-6000K as per user requirement 18 watts with efficiency of 100 lumens per watt, in worm white/ neutral white as per site requirement sleek design aluminium housing polycarbonate diffuser white finish operating voltage from ceiling rose to fitting complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED building security light fitting 35 Watt (or above) 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with electronic driver including thermal management in multiple optics complete with IP 65/66 protection complete with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED building security light fitting 30 Watt (or above) 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with electronic driver including thermal management in multiple optics complete with IP 65/66 protection complete with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed by Engineer-in-charge.
S&F in repair of GI pipe bracket medium grade of 40 mm dia for building security light,clamps made of FI 40 mm x 6 mm Incl nuts,bolts & washers, painting complete all as specified and directed by Engineer-in-charge.
S&F Integral decorative LED bollard with polycarbonate diffuser square shaped with IP 65 protection suitable for 10 watts LED & height of light 0.6 M ,with necessary MS base box made out of MS sheet of 2 mm thick of suitable size abbended in PCC 1:2:4 base, elecrical connections with adequate size including removal of old unserviceable one complete all as specified and directed by Engineer-in-charge.
S & F for LED post top lantern/gate Light 20 watt light fitting made of die cast top housing must also be dia cast aluminium spigot housing with decarative acrylic diffuser with IP 65 protection complete with all accessories including removal of old unserviceable complete all as specified and directed by Engineer-in-charge.
S & F for LED post top lantern/gate Light 40 watt light fitting made of die cast top housing must also be dia cast aluminium spigot housing with decarative acrylic diffuser with IP 65 protection complete with all accessories including removal of old unserviceable complete all as specified and directed by Engineer-in-charge.
Supply and fix energy saving, environment friendly & robust Highbay/Mediumbay roof truss light LED for covered shed 150 W IP65 luminaire with high efficacy with fixing arrangement such as bracket,MS clamp, Nut bolts etc and connecting complete all as specified and directed by Engineer-in-charge.
S/F flame proof rotary type switch with termination box in LM6, 16A, douple pole 250V complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED light fitting 1x20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable in flexible metalic conduit with suitable size complete all as specified and directed by Engineer-in-charge.
S & F for MCCB DB VTPN 4 way 415 V double door IP 43 with provision for FP MCCB/Isolator/RCCB etc as incommer and SP/TP MCBs as out going complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply complete all as specified and directed by Engineer-in-charge.
S & F for sheet metal enclosure MCB DB TPN 4 way double door IP 43 with 200 Amps rated bus bar 415 volts double door with magnitic locking system complete all as specified and directed by Engineer-in-charge.
S & F for sheet metal enclosure MCB SPN DB 12 way with 200 Amps rated bus bar 240 volts double door IP43 with magnitic locking system complete all as specified and directed by Engineer-in-charge.
S & F for sheet metal enclosure MCB SPN DB 8 way with 200 Amps rated bus bar 240 volts double door IP 43 with magnitic locking system complete all as specified and directed by Engineer-in-charge.
S & F for sheet metal enclosure MCB SPN DB 4 way with 200 Amps rated bus bar 240 volts double door IP 43 with magnitic locking system complete all as specified and directed by Engineer-in-charge.
S&F Sheet metal and neutral enclosure single pole with two pin and earth plug and socket single pole MCB 20 Amps 240 volts fixed complete all as specified and directed by Engineer-in-charge.
S & F MCCB 4P 415 volts 16 KA suitable for fixing on VTPN DB of capacity 160 Amps with extended terminals complete all as specified and directed by Engineer-in-charge. Note :- Suitable size and frame of MCCB required as per existing DBs at site, MCCB Rating ICS=100 % ICU
S & F MCCB 4P 415 volts 16 KA suitable for fixing on VTPN DB of capacity 125 Amps with extended terminals complete all as specified and directed by Engineer-in-charge. Note :- Suitable size and frame of MCCB required as per existing DBs at site
S & F MCCB 4P 415 volts 16 KA suitable for fixing on VTPN DB of capacity 100 Amps with extended terminals complete all as specified and directed by Engineer-in-charge. Note :- Suitable size and frame of MCCB required as per existing DBs at site
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of tripple pole and neutral rated capacity TPN 63 Amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of tripple pole and neutral rated capacity TPN 100 Amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
Supply and fixing miniature circuit breaker (MCB) of single pole and neutral SPN 40 AMP to 63 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
Supply and fixing miniature circuit breaker (MCB) of single pole SP 10-32 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
Supply and laying of 1100 volts grade heavy duty service cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 2 Core including PVC conduit pipe nominal cross section in service connections complete all as specified and directed by Engineer-in-charge.
M/S PRASHANT BENIWAL
Rasam Engg Co.
SHRI HARI CONSTRUCTION
Aman Enterprises
Manisha Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .