Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹5.1 Cr
EMD Value
₹5.8 L
Closing Date
7 Mar 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ Chief Engineer Jabalpur Zone
HQ Chief Engineer Jabalpur Zone Ridge Road Jabalpur Cantt 482001
PROVN OF HRDC BLDG AT INF SCHOOL MHOW
2024_MES_688696_1
752955A PROVN OF HRDC BLDG AT INF SCHOOL MHOW
Open Tender
Civil Works
Lump-sum
580 days
MHOW
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE MIS Mhow
₹5.8 L
Yes
30 Jan 2025
30 Jan 2025
14 Mar 2026
17 Dec 2025
7 Mar 2026
16 Feb 2026
SCHEDULE "A" PART-I (Building Work) Lump sum price worked out by the contractor for 'Building Work' as listed in Schedule 'A' Part-I against the lump sum price inserted by the MES.
Item No 28: S& F occupancy sensor suspended type to detect the presence of a person for include automatic adjustment of lights systems in response to the quantity of people present for switch off/on the light in a circuit as per user reqmt (for use at parking area, verandah or any other space where power saving
Construction of HRDC building (G+2) including class room, examination hall, office and parking shed complete all specified and shown on drg.
(c) 25 mm (1”) dia
Sch 'A' Part-IV (Internal Electrification) Lump sum price worked out by the contractor for 'External Water supply' as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES.
Lump sum
Sch 'A' Part-II (B/R works including internal services) Lump sum price worked out by the contractor forB/R works including internal services as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES.
Sch 'A' Part-III (External Water Supply) Lump sum price worked out by the contractor for 'External Water Supply' as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES.
Sch 'A' Part-XI (Road, Path & Hard standing) Lump sum price worked out by the contractor for 'Road, Path & Hard standing', excavation & earth works' as listed in Schedule 'A' Part-XI against the lump sum price inserted by the MES.
Sch 'A' Part-VI (Fire detector system) Lump sum price worked out by the contractor for 'Fire detector system/ Alarm System' as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES.
Sch 'A' Part-VII (Water Cooler) Lump sum price worked out by the contractor for 'Water Cooler ' as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES.
Sch 'A' Part-V (External Electrical Supply) Lump sum price worked out by the contractor for'External Electrific Supply' as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES.
Sch 'A' Part-XIV (SITE CLEARANCE) Lump sum price worked out by the contractor for 'Site clearance, excavation & earth works' as listed in Schedule 'A' Part-XI against the lump sum price inserted by the MES.
Item No 01 : S&F factory made SFRC MH cover with frame confirming to IS 12592:2002 HD 20 grade, of size 600mm circular or square, sorrounded with steel strip 70 x 1.5 mm reinforced shall be as per relevant IS and laid over man hole brick work or concrete in CM 1:4, incl reinforcement, complete all as specified and as directed. Notes: - (i) Contractor shall provide PV alongwith manufacturer test certificate of SFRC cover.
Fire detector system/ Alarm System
Item No 03 : S & F for Detector Complying with & type cetified to EN-45 Addressable type Multisensor detector with heat and smoke combination /Optica with base with self built intelligence as per IS: 11360.
Item No 04: S & F testing & Commission of MICRO processer with Digital Display fire control Panel with Single Panel of capacity for 99 Detector & 99 Module upto 200 detector & modules fitting with autoatic battery charger including Maint free battery , including lamp with all connected accessories 1 Zone.
Item No 05 : S & F including Testing, Commmessioning of Manual call point resettable type complete all as specified..
Item No 06 : S & F for fire Alarm Sounders/ sirens Electronic type horizontal two stage continous normal operation for atlast 50 minutes with sound level 65 DB to 120 DB measured at 105m with sound out put variation of + 5 DB upto 500 mtr range complete all as specified..
Supply, laying and testing ISI Marked 2 core x 1.5 mm2, Multistrand Copper FRLS Armoured cable (red in Colour), laid on surface with GI saddle-spacers every 0.3 meters. Complete with Gl Junction Box, lugs, cable compression glands, cable tags and Ferruling.
Item No 07 : Remote Indicator/ Response indicator (LED TYPE) complete all as specified.
Item No 10 : Supply and fix Air cushioning tank (Air vessel) 250mm dia x 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia. Brass air valve (ball type), 20mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories complete.
Item No 13 : Supply & Fixing Exist sign board or information board duly fabricated with flexo sheet or high grade quality and writing/ printing of information/picture/drawing/layout pln over flexo sheet duly structure framed with square iron bar of suitable size and fixed with suitable screws complete all as specified and as directed.
Supply and Installation of Water cooler partially stainless steel working with non CFC refrigerant rating suitable for operation on 230 Volts 50 Hz AC supply having approx storage and nominal cooling capacity 40/80 Ltrs. incl connecting the Items complete with and including making of PCC plateform of suitable size for fixing of water cooler and connecting of water cooler with Heavy duty PVC flexible pipe, Connections,complete all as specified and as directed by Engr-In-Charge.
Supply, install, testing and commissioning of inverter Split AC unit having one indoor and one outdoor unit of capacity 1.5 TR, 5-star rated with rotary compressor, environment friendly non-CFC refrigerant including necessary copper tubing, steel wall bracket, cordless remote, electric wiring connection etc complete all as specified and directed by Engineer-in-charge.
Item No 15 : Supply, laying and testing of centrifugally cast (Spun) ductile iron pressure pipe Class K-9 with spigot and socket ends in and including rubber gaskets of suitable size for connecting the tyton joints, pipes duly applied with zinc coating with finishing layer of bitumen on external surfaces and cement mortar lining with bituminous seal coat on internal surfaces complete conforming to IS -8329 (2000), complete of following sizes all as specified and directed by the Engineer-in Charge at site.
(a) 100 mm (4’’) dia
Item No 15 : Supply, laying and testing of centrifugally cast (Spun) ductile iron pressure pipe Class K-9 with spigot and socket ends in and including rubber gaskets of suitable size for connecting the tyton joints, pipes duly applied with zinc coating with finishing layer of bitumen on external surfaces and cement mortar lining with bituminous seal coat on internal surfaces complete conforming to IS -8329 (2000), complete of following sizes all as specified and directed by the Engineer-in Charge at site.
(a) 100 mm (4’’) dia
Item No 17 : M&L for Construction of brink masonry valves pits, of following internal dimension complete with 3.5 mm thick MS sheet cover angle iron frame duly painted with locking arrangement including all necessary excavation and earth work PCC work complete
(a) 900 mm x 900 mm x 900 mm
Item No 11 : BLANK
Item No 09 : S & F for Terrace Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz, 30m head, 450 LPM discharge, including suitable starter complete all as specified and as directed
al sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories and also including removing old exisisting one complete all as specified and as directed.
INCOMING
OUTGOING
Refrigeration & Air Conditioning
Water Cooler
(d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board
Description all as per item No 1 here in before but using 4.0 sq mm single core copper conductor two nos FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 4.0 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly.
Item No 23: S & F modular type TV Socket out let complete all as specified and as directed.
M & L for earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 3 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC (1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC (1:2:4) type B-1 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia Gl pipe medium grade as watering pipe and 15 mm dia GI pipe for protection of Gl wire up to 7.5 mtr connected to earthing point complete all as specified and as directed.
S & F for MCB Single pole rated capacity 6-32Amps, 240 Volts breaking capacity 10 KA, 'C' curve B complete all as specified and as directed.
Each Set
S&F Vitreous China soap tray chromium plated, fancy type embedded in the wall complete all as required at site and as directed by Engineer in Charge
S&F in repairs Brass Chromium plated tubular towel rail, 20 mm dia. , D Type, 60 cm long between flanges including taking down the existing towel rail
Internal Water supply
Item No 29: S& F Self-closing pillar taps 15 mm dia,fancy type, chromium plated, cast copper alloy, chromium plated, screwed for iron pipe and fi
Schedule 'A' Part-I
(Building works)
Item No 27: S & F modular MCB protected socket comprising of 24A MCB C curve, and 16/20 A Socket for AC/Geyser, modular switch 16A complete with Sheet metal Enclosure for 230 volt 50 Hz AC including all acessories as one complete set all as specified and as directed.
Total Amount
Signature of Contactor
Sch 'A' Part-XIII (Area Drainage) Lump sum price worked out by the contractor for 'Area Drainage', excavation & earth works' as listed in Schedule 'A' Part-XII against the lump sum price inserted by the MES.
Sch 'A' Part-XII (Sewage Disposal) Lump sum price worked out by the contractor for 'Sewage Disposal', excavation & earth works' as listed in Schedule 'A' Part-XII against the lump sum price inserted by the MES.
(iii) 20 mm outer diameter
Note for Srl No 2 to 16 The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 16 by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule
(Internal Water Supply)
Schedule 'A' Part II
(ii) 25 mm outer diameter
S&F dual type PVC lopw level flushing cistern of capacity 5/10 litres complete with syphon handle lever float valve and PVC blend including connecting to ITWC/ETEC and fixing on wall bracket complete all as specified and directed by Engr-in-charge
Suplly and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floor complete all as specified and as directed of following size
S&F for angle stop valves,15 mm cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handie, screwed both ends for iron pipe or for unions and fixed complete.
S&F fort Bib taps, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, 15 mm fixed complete
S&F 25mm CPVC or ball valves, with CPVC wheel head, screwed both ends for CPVC pipe and fixed design complete all as required at site and as directed by Engineer in Charge
S & Fof Maie brass threaded adoptor/ female brass threaded adopter 20 x 16 mm size
S&F 40 mm CPVC or ball valves, with iron wheel head, screwed both ends for iron pipe and fixed design complete all as required at site and as directed by Engineer in Charge
Total carried over to BOQ Rs.
SIGNATURE OF CONTRACTOR
DATED _________
Schedule 'A' Part III
(Lan Conduit)
tem No 14 (a) : S&F fire extinguisher DCP (ABC) type 5 kg capacity conforming to IS-15683: 2006 complete all as specified and directed
M&L for fixing gun metal gate valve with iron wheel head, screwed both ends for iron pipe with necessary GI fittings and testing complete all as specified and directed of following sizes
(a) 50 mm (2”) dia
(b) 40 mm (1.5”) dia
S & F for Energy saving new gener
Schedule 'A' Part-XIV
M&L for fixing gun metal gate valve with iron wheel head, screwed both ends for iron pipe with necessary GI fittings and testing complete all as specified and directed of following sizes
(a) 50 mm (2”) dia
(b) 40 mm (1.5”) dia
S & F for Energy saving new gener
Total carried over to BOQ Rs.
SIGNATURE OF CONTRACTOR
DATED _________
Schedule 'A' Part IV
(Internal Electrification)
Item No 21: Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts with output voltage stablized at 230 volts with accuracy of ± 2.5 % and capacity 5 kVA suitable for A/C complete all as specified
Item No 22: Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts with output voltage stablized at 230 volts with accuracy of ± 2.5 % and capacity 2 kVA suitable for above water cooler
(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
(c) One light point controlled by one, two way switch 5 Amps
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade IS1-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour Including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI Sunken box1.2mm thick, duly covered with modular white colour plate with frame and other necessary accessories Including PVC Insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following:-
(e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
M&L for Laying and compacting 150 mm thick (compacted thickness) Granular Sub Base Course (GSB) grading as per Grade III as specified Table 400-1 of MoRTH specifications for Road and Bridge works, 2013, in a single layer over compacted subgrade with natura sand, crushed gravel, crushed stone, crushed slag or combination thereof as per the grading required .The materials are mechanically mixed, spread and leveling on the subgrade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 80-1 00 KN static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density. Consolidating to required gradient and camber complete all as specified and directed with finished surface tolerances as per Table 900-1 of MoRTH specifications for Road and Bridge works, 2013 complete all as specified and directed.
(a) One light point controlled by one, one way switch 5 Amps
S & F ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete.
S & F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified.
S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified.
S & F modular switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified.
S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F for sheet metal enclosure MCB DB HTPN 4 way Horizontal type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
M& L for Laying and compacting 225 mm thick (compacted thickness) in 3 Layer of 75mm thick each Wet Mix Macadam (WMM) grading as per table 400-13 of MoRTH specifications for Road and Bridge works 2013 manufactured in WMM plant material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-1 OOKN static weight and consolidating to required gradien and camber complete all as specified and directed The finished surface tolerances to be as per Table 900-1 of MoRTH specifications for Road and Bridge works 2013 complete all as specified and directed.
Item No 24: S & F modular type LAN Socket RJ 45 with complete box
Item No 25: S & F modular type Telephone socket RJ 11/12 with complete box
S & F for sheet metal enclosure MCB DB HTPN 6 way Horizontal type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of size 10 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 10.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Four runs of 10 sqmm cable, one run of 10 sqmm cable and one run of PVC conduit will be measured as one unit
S & F for sheet metal enclosure MCCB DB VTPN 6 way Vertical type with 250 Amps rated bus bar 415 E volts for incomming MCCB 4 pole -01 Nos and out going MCCB 4pole -04 Nos with double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCCB four pole rated capacity 80 Amps, 415 Volts breaking capacity 16 KA, complete all as specified and as directed.
S & F for MCCB four pole rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB DP rated capacity 32 A Amps, (nearest standard size) 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 20-32 Amps, 240 Vo
ation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts, luminous efficacy not less than 110 lumen/watt, with warranty option 2 years, life span 20000 Hrs to 25000 Hrs with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer-in-charge.
M&L for PCC 1:3:6 Type C1 (20mm graded aggregate) as in surface channel and drains
M&L for applying evenly a prime coat of cationic bitumen emulsion SS-1 confirming to IS: 8887 at a rate of application of 0. 7-1 kg/sqm on surface o WMM/WBM as specified in Table 500-3 of MoRTH specification for road and bridge works 2013, using mechanical sprayer complete all as specified and directed .
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
S & F for LED 10 watts batten aluminium extruded with decorative end caps luminous efficacy not less than 120 lumen/watt complete all as specified and as directed Note: LED Chip, Driver & Housing shall be of same make and Contractor has to fixed Screen print self adhesive sticker contains the information CA No., Name of Contractor and Date of intallation without any extra cost.
Description all as per item No.1 here in before but using 2.5 sq mm single core copper conductor two nos cables of multistranded FRLSH PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
lts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air-DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. NOTE: Marking of MES No, Date of installation and CA No on Fan shall be done without any extra cost.
Total carried over to BOQ Rs.
SIGNATURE OF CONTRACTOR
DATED _________
Schedule 'A' Part V
(External Water Supply)
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in
layers not exceeding 25cm each complete.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
Sand cushioning with fine dry unwashed sand in trenches for protection of cables complete.
Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part VI
S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 25 mm dia for LAN, telephone and TV connections for concealed complete all as specified and directed.
S & F surface/recess mounted ceiling light of capacity 36 watt, approx size of 2x2 ft, 230 volts with CRCA housing luminous efficacy not less than 120 lumen/W with and intregrated electronic driver connector block etc with warranty option of 2 years, life span 20000 Hrs to 25000 Hrs from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor with flexible conduit of suitable size complete all as specified and as directed. Note: LED Chip, Driver & Housing shall be of same make and Contractor has to fixed Screen print self adhesive sticker contains the information CA No., Name of Contractor and Date of intallation without any extra cost.
S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, luminous efficacy not less than 120 lumen/watt 230 volts and intregrated electronic driver connector block etc with warranty option of 2 years, life span 20000 Hrs to 25000 Hrs from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor and flexible conduit of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Note: LED Chip, Driver & Housing shall be of same make and Contractor has to fixed Screen print self adhesive sticker contains the information CA No., Name of Contractor and Date of intallation without any extra cost.
Supply and fix yard hydrant post / stand post made of MS pipe of size 80mm dia flanged type of 1.5m height complete all as specified.
S&F for LED 10 watt fitting, luminious efficacy not less than 120 lumen/watt, natural white, power factor greater than 0.95, IP 20, Color Temp 6500K (Cool White), CRI 80, warranty option 02 yrs, life span 20000 to 25000 hours, LED chip, Driver & Housing shall be of same make in-built surge protection of 3kVa complete all as specified and as directed. Note: Contractor has to fixed Screen print self adhesive sticker contains the information CA No., Name of Contractor and Date of intallation without any extra cost.
(d) 20 mm (3/4”) dia
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator modular type and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CMM with service value 6.0 BEE. Five star rated with brushless direct current motor (BLDC) with remote control complete all as specified and as directed. NOTE: Marking of MES No, Date of installation and CA No on Fan shall be done without any extra cost.
Supply & Fix Gun metal one way fire hydrant landing valve of size 63 mm dia complete with instantaneous coupling complete.
Suppling, fix, and jointing heavy grade MS pipe, class 'C' ERW grade conforming to IS: 1239 in trenches/wall/floor including all inclding all fittings, such as coupling, bends, elbow, and tee etc, screwed joint all as specified of 100 mm dia
Hose box made of 18 gauge MS Sheet 800mm x 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard
S & F 63 mm dia, 15 mtr long rubberised fabric reinforced rubber lined hose including gun metal male & female instataneous coupling, hose confirming to IS : 636 type ll and coupling confirming to IS 903-1975 as specified
S&F first aid fire hose reel, wall mounted swivel type fitted with 30 mtr long, 20mm dia, high pressure dunlop hose conforming to IS: 5132 with 15 mm dia outlet, gun metal nozzle with shut off valve as per IS 884- 1969.
S & F standard short size gun metal branch pipe with gunmetal nozzle 16 mm nominal bore, outlet and standard instantaneous coupling 63 mm dia complete all as specified
Item No 12 : BLANK
Supply and fix CI sluice valve with flanged ends, cast iron body flanged and drilled end non rising type, HT bronze spindle with nuts, class PN-1.6 suitable for 100 mm bore as per IS : 14826, ISI marked including all joints with rubber or fiber board, bolts and nuts, washers etc complete all as specified.
Supply and fix CI sluice valve with flanged ends, cast iron body flanged and drilled end non rising type, HT bronze spindle with nuts, class PN-1.6 suitable for 150 mm bore as per IS : 14826, ISI marked including all joints with rubber or fiber board, bolts and nuts, washers etc complete all as specified.
Supply & fixing two way fire brigade inlet/collecting breaching with 63 mm dia GM male instanteous inlet and NRV flanged outlet complete all as specified.
Supply and fix non-return sluice valve 100 mm bore complete, incl connection and testing complete all as specified.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part VII
(Fire detector system/ Alarm System)
supply, installation, commissioning and testing of DOL/Star-Delta Starter device suitable for power capacity upto size 10.0 kW (for submersible pump complete all as specified and directed by Engr-In- Charge.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part VIII
(Water Cooler)
(Refrigeration and air conditioning)
S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections for concealed complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part IX
S & F XLPE insulated and PVC armoured heavy duty electric cables with aluminum conductor, of size 10 Sqmm , 4 core , 1100 volt grade in trenches/through pipes/ducts or on poles/walls jointing to LT panels, main switch with suitable size aluminum lugs and testing complete all as specified & directed
Total carried over to BOQ Rs.
Signature of Contactor
(External Electrical Supply)
(Rain Water Harvesting)
xed of approved make and design complete all as required at site and as directed by Engineer in Charge
S&F 160mm bore PVC (SWR) rain water pipes single socket in any length with rubber ring joint fixed to walls with necessary pvc clamp.
S&F 160mm bore PVC (SWR) bend of any radius.
S&F 160mm bore PVC (SWR) branch piece, (single Y) equal or unequal.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part X
(Road, Path & Hard standing)
Rolling and consolidating formation surface in cutting with 8 to 12 tonne power roller.
M&L for PCC 1:2:4 type B0, using 12.5mm graded stone aggregate, as in coping complete all as specified and di-rected
S&F 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors completed all as specified and directed
M & L Scarifying or picking gravelled,macadam or bituminous macadam surfaces in area exc 400 sqm n ex 50 mm deep complete all as specified and directed.
M&L for PCC 1:2:4 type B2, using 40mm graded stone aggregate as in surface channels and drains complete all as specified and directed
M&L for providing and consolidating 50 mm thick premix Dense Bituminous Macadam (DBM Grading-II) using min 4.5% VG 30 grade binder by weight of total mix aggregate gradation as per Grading 2 of Table 500-1 0 of MoRTH specification for road and bridge works 2013, rolled and compacted to required camber and gradient complete all as specified and directed.
M&L for Bituminous premix asphaltic semi dense concrete 40mm consolidated thickness with 5.50% binder content by weight of total mix, rolled and compacted to required camber and gradient complete all as specified. The premix shall be prepared in hot mix plant and laid with mechanical paverall as specified. Note:- (i) The bitumen content to be incorporated in the works shall be as per Job Mix . The minium bitumen used in the work shall be shall be as specified in respective item of total weight of mix (minimum). No extra payment shall made to contractor if bitumen content works out in design mix is more than the minimum specified. (ii) Filler material for semidence asphaltic concrete shall be Cement only, (iii) The cost of Job mix charges shall be borne by contractor. The same shall be deemed to be included in the unit rates quoted.
M&L Moorum filling in pavings laid in layers 15 cm thick(spread thickness), levelled and blinded with earth and rammed including watering in berms
M & L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed. complete all as specified and as directed.(Make:- STP/ASIAN PAINTS/BERGER) NOTE:- Application shall be carried out through mechanical appliances by the approved applicator of the manufacturer of paint.
S&F Supply and fixing cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions.
Supply and fix solar cat eye aluminum alloy shall (100% water proofing design according to 65) ofsize 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/0.3 watt one NI-ed rechargeable battery (1.2V/1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed
Hardcore of guage n exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface
M/L for 75 mm thick PCC 1:4:8 type D2 using 40mm graded stone agregate as in base for sustainable concrete pavement/service road all as specified.
M&L for machine pressed precast concrete interlocking paver block 80mm thick any shape and size conforming to IS-15658-2006 M-40grade over sand cushioning
M&L 20mm thick sand cushioning including spreading and levelling complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coping etc. including necessary use and waste of form work complete all as specified and as directed.
M&L plain Cement concrete 1:4:8 D2 40mm graded aggregate in foundations, filling and mass concrete as directed by Engineer-in charge
M&L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors complete all as specified and directed.
M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built modular brick in cement mortor 1:4 all as specified and directed.
M&L for Reinforced concrete pipes 450mm bore class NP3, laid and jointed complete with collars complete all as specified and directed.
M&L for 15 mm thick plaster in CM 1:4 on brick walls or concrete surfaces and in any position including finishing the surfaces fair and even (without using extra cement), complete all as specified and directed.
M&L for preparation of surface and applying three coat of white wash on newly plasteted surface complete all as specified and directed.
M & L for factory made precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in road side edging block of size 450 mm x 300 mm x 75 mm laid with width equal to thickness of block laid on end vertically set jointed & pointed in CM 1:4 and with and including necessary form work, completed all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part XI
(Sewage Disposal)
M&L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors complete all as specified and directed.
M&L plain Cement concrete 1:4:8 D2 40mm graded aggregate in foundations, filling and mass concrete as directed by Engineer-in charge
M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built modular brick in cement mortor 1:4 all as specified and directed.
M&L fly ash brick in CM 1:4 with modular size bricks curved on plan n exc 6m means radius
M&L brick work with fly ash bricks in one brick thick honey combing walling built in CM 1:4
Reinforced cement concrete (design mix )in M-30 in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
Reinforced cement concrete (design mix )in M-30 in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses
Reinforced cement concrete (design mix )in M-30 in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L for PCC 1:2:4 type B-1 (Using 20 mm graded aggregate) as in coping, channel, benching etc laid to shape and slope and finished even and smooth using extra cement including weathering, throating and necessary form work complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Formwork to faces of walls, retaining walls, butments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide
M&L mild steel TMT bars 10mm dia & over cut to length bent to shape required, including cracking, bending spirally to proper for columns, hooking end & binding with and inch mild steel wire not less than 0.9mm dia or securing with clips quality conforming to complete all as specified and directed.
S&F TMT bar 6 to 8mm dia cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
S&F Bands, straps, supports or stays for rainwater, entilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 ®
M&L for 15 mm thick plaster in CM 1:4 on brick walls or concrete surfaces and in any position including finishing the surfaces even and smooth (without using extra cement), complete all as specified and directed.
Supply only intergral water proofing compound
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc all as specified and directed.
M & L for hardcore of broken stone or boulders guage exc n 63mm deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface
S&F 110mm PVC (SWR) pipes in any length with or without ears, with cement joints, laid in trenches or in floors
S&F 110 mm PVC (SWR) cowls with solvent joints complete.
S&F 110mm PVC (SWR) Single 'Y' junctions/T Junction with solvent joints complete.
Preparing new surfaces and applying two coats of cement base paint on wall
M&L for loose filling with broken bricks bats of gauge 80 to 150 mm in soakage pits, soakage wells
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part XII
(Area Drainage)
M & L for PCC 1:4:8 type D-2 (using 40mm graded aggregate ) in foundations, filling and mass conctrete all as specified and as directed.
M&L raised Pointing in CM 1:3 to squared rubble, coursed/uncoursed masonry, coursed or uncoursed in Cement Mortar complete all as specified and directed
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc
M&L for brick work with fly ash bricks(modular sze), straingt or curved on plan exc 6m mean radius, build in CM 1:4 complete all as per directed
M&L 15mm thick rendering in cm 1:4 on fair faces of brick work finished even and smooth(without using extra cement) conctrete all as specified and as directed.
M & L for RCC M-25 (Design Mix) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs and mass concrete complete.
M & L for RCC M-25 (Design Mix) as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings and buttresses complete.
Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete.
Use and waste formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter curved and rough finished surfaces of concrete.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes in drain grill/grating work and conforming to Fe.290.Gde-E-165 complete all as per directed
M&L two coats of synthetic enemal paint over a coat of red oxide over prepared surfaces of new steel surfaces
M&L for precast RCC type B-1 1:2:4 using 20mm graded stone aggregate as in manhole cover, set in CM 1:6 incl use and waste of formwork all complete all as specified and directed.
M&L TMT bar 10 mm dia and over, cut to length, bent to shape required ,including cranking, bending spirally for hooping for columns,hooking end and binding with and including mild steel wire and annealed not less than .9 mm dia complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part XIII
(SITE CLEARANCE)
Item No 30: S & F chromium plated health faucet 15 mm with spirochrome flex hose (1.20 mtr long), handset & bracket complete suitable for EWC/IWC of approved make and design complete all as required at site and as directed by Engineer in Charge
Item No 31: S&F two way Bib cock taps, fancy type, chromium plated, cast copper alloy with crutch or butterfly handie, screwed down, screwed for iron pipe or for brass ferrule and fixed of approved make and design complete all as required at site and as directed by Engineer in Charge
Item No 32: S&F urinal spreader fancy type, chromium plated, bowl top iniet with fixing stud for fixing with 15 mm dia pipe design compiete all as required at site and as directed by Engineer in Charge
M & L for providing rain water harvesting system for recharging ground water table guiding rain water flow of building roof to recharge pit of 2000 litre capacity as given in drawing No; 25. include the following :- (i) Excavation and earthwork upto 1.80m deep and 1.50m in dia, brick work in wall upto 0.80m height. (ii) Boulder (5 to 10mm) filling upto 0.30m in top. (iii) Coarse sand filling upto 0.50m height. (iv) Gravel (5 to 10mm ) filling upto 0.50m height. (v) Boulder ( 5 to 10mm) filling upto 0.50m in bottom. (iv) Down take pipes 100mm size - 15mtr (v) Drilling of Bore hole 200mm dia -15m (vi) PVC pipr 160 mm dia in bore hole -15m (vii) Boulder filling around the 160 mm pipe
Surface excavation n.exc 30 cm deep and averaging 15cm deep p and and getting out in any type of soil compiete all as specified and directed.
Removing excavated material exc 50 m but n.exc 250 m and depositing where directed.
Earth work in excavation in ordinary rock in ordinary rock by mechanical means (hydraulic excavator) means over area exc 30cm in depth, 1.5m in width including getting out and disposal of excavated earth load upto 50m and lift upto 1.5m, as directed by Engineer - in- charge getting out in any type of soil including soft/disintegrated rock completed all as specified and directed
Excavation in trenches, n.exc. 1.5m wide and n.exc. 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in mixture of any type of soil and soft/disintegrated rock completed all as specified and directed
Excavation in trenches, n.exc. 1.5m wide and exc 1.5m in depth but not exceeding 3.0m in depth for foundation, etc getting out in mixture of any type of soil and soft/disintegrated rock completed all as specified and directed
Excavation in trenches, n.exc. 1.5m wide and exc 3.0m in depth but not exceeding 4.5m in depth for foundation, etc getting out in mixture of any type of soil and soft/disintegrated rock completed all as specified and directed
Removing excavated material (soil) to a distance exc. 1.50 km but n exc. 5 km depositing where directed completed all as specified and directed
Returning filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 25cm thick, complete all as sspecified and directed
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick, watering, ram-ming/rolling and finishing to required Size, shape. etc. nexc. 1.5 m high from base
M&L foundation for PCC filing 1:4:8 type D2, using 40mm graded stone aggregate, as in foundation filing, mass concrete etc. complete all as specified and directed
M&L for Walling of squared rubble, coursed, well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified and directed
Total carried over to BOQ Rs.
Signature of Contactor
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
Tender.pdf
Tender Documents • 1.71 MB
BOQ_778490.xls
BOQ • 0.43 MB
C15.pdf
PDF • 0.12 MB
C14.pdf
PDF • 0.12 MB
C13.pdf
PDF • 0.12 MB
C12.pdf
PDF • 0.12 MB
C11.pdf
PDF • 0.12 MB
C10.pdf
PDF • 0.09 MB
C9.pdf
PDF • 0.18 MB
C8.pdf
PDF • 0.18 MB
C7.pdf
PDF • 0.18 MB
C6.pdf
PDF • 0.18 MB
c03.pdf
PDF • 0.09 MB
C3.pdf
PDF • 0.18 MB
C1.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .