Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹18.2 L+₹88,660 (5.14%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹19.7 L+₹2.4 L (14.1%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹20.5 L+₹3.2 L (18.7%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹24.1 L+₹6.8 L (39.6%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
13 Sept 2022, 6:00 pmClosed
GE MH and RH KIRKEE
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Kirkee Pune 411003
REPAIR RENEWAL MAINTANANCE OF INTERNAL ELECTRIC WIRING AND CERTAIN CONNECTED WORKS INCLUDING OT LIGHTS AT PHASE I OF MH KIRKEE UNDER GE MH RH KIRKEE
2022_MES_541832_2
8321/E8
Open Tender
Civil Works
Item Rate
300 days
GE MH and RH KIRKEE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH and RH KIRKEE
₹50,000
18 Nov 2022
24 Aug 2022
15 Sept 2022
24 Aug 2022
13 Sept 2022
1 Sept 2022
24 Aug 2022 - 6 Sept 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items shall be made as per conditions laid down under schedule of credit separately) and making good disturbed surfaces of walls, floors, all as specified.
Taking down old unserviceable submain wiring of any type any size complete all as specified and directed with casing capping / surface conduit
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified.
M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and inciuding medium grade, PVC concealed/surface conduit on wall/roof/floor etc, ISI marked with suitable accessories , mild steel/pressed steel sunken box of 1.2 mm thick and 60 mm deep (with earth dolly) duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally,covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for the following:-
One light point controlled by one switch complete.
One Fan point controlled by one switch complete.
One 5 pin 6 Amps socket outlet on independent board.
One 5 pin 6 Amps socket outlet on same board.
One bell /buzzer point controlled by one push button on the same board with other switches or indipendent.
One light point controlled by two way switch complete.
All as per item No 4.00 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 v grade PVC insulated but unsheheted copper conductor FRLS cable 1100 volts grade and 2.5 sqmm PVC insulated but unsheathed FRLS cable as earthwire for 16 Amps power point on independent board complete all as specified and directed by Engr-in-charge.
S & F switch piano type, one way, 6 Amp all as specified
S & F switch piano type 16 Amps all as specified
S&F Bell push, flush type 6 Amp all as specified
S & F switch piano type two way 6 Amps all as specified
S&F Bell push, Modular type 6 Amp all as specified
S & F socket outlet 2 in1,3 pin 5 Amps all as specified
S & F socket outlet 2 in 1, 3 pin, 6 and 16 Amps flush type in all as specified
S & F switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type in all as specified
S & F switch socket combination 2 in 1, 3 pin, 5 Amps flush type all as specified
S & F switch socket combination 2 in 1, 3 pin, 5 Amps flush type with fuse & neon lamp indicator in all as specified
S & F switch socket combination 2 in 1, 3 pin, 5 and 15 Amps Box type in all as specified
S & F switch socket combination 2 in 1, 3 pin, 5 Amps Box type all as specified and directed by Engr-in-Charge all as specified
S & F PVC ceiling rose surface type three terminals type in replacement/ repair all as specified
S & F Buzzer / ding dong AC 230 volts, 6 Amp single Phase in white /Ivory colour finish inreplacement/ repair all as specified
S &F in replacement lamp holder, Insulated body with back plate for batten fitting
S & F in repairs surface wall mounted Regal Batten with and including T8 tube rod energy efficient 20 W LED (four feet) complete in all respect including taking down old conventional type tube light fitting. Make : Havells cat part No. (REGALBATTENT8UPTO2X22WSSB SWH) or equivalent in Havells/ Wipro/ Philips)
S & F in repairs surface and wall mounted LED T5 integrated batten Batten with integrated electronic driver energy efficient 10W LED (Two feet) decorative complete in all respect including taking down old conventional type tube light fitting. Make : Havells / Wipro / Philips
S&F in repairs Recess mounting LED ultra mordern design Light fitting 36 watt ,600 mm x 600mm size with efficient LEDs all as specified and directed. Make : Havells / Philips / Wipro
S&F in repairs recess mounting LED clean room Light fitting 36 watt, 600 mm x 600mm size with efficient LEDs all as specified and directed. Make : Havells / Philips / Wipro
S & F in repairs 20W ultra bright glass LED Tube Rod of size 4 ft all as specified and directed. Make : Havells / Philips / Wipro
S & F in repairs new genration energy saving environment friendly long life 25 Watt LED Bldg security light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seprate driver compartment with IP66 Protection and impact resistance of IK07 Building security lights.
Supply and fix in repair high quality LED base 18 watt, 4 pin PL Lamp. Make : Havells Cat part No PHOTONULTRAPLL4 19TL18W LED865SPC or Crompton / Wipro/HPL/Syska
Supply and fix in repair of LED Driver suitable for recess mounting LED Light fitting 32W to 42W watt of (any Make) 600 mm x 600mm size. Make : Crompton / bajaj/ Havells/HPL/Syska
Supply & fix PIR Motion sensor of detection range 360 , detectction distance more than 6 mtr,installation height 2.5 to 4 m and detection movement speed .06-1.5 m/s including necessary wiring with 2.5 sqmm three core multi stranded copper condcutor 1100 v grade from light/ main board to sensor all as specified and directed. Make Crabtree: Product code ACSBA005 equivalent approved make.
Supply & fix PIR surface mounted Motion sensor of detection range 360, detectction distance more than 20 mtr,installation height 2.5 to 6 m and detection movement speed .06-1.5 m/s including wiring with 2.5 sqmm three core multi stranded copper condcutor 1100 v grade from light/ main board to sensor all as specified and directed. Make Crabtree: Product code ACSBA003 equivalent approved make.
S & F for MCB DB TPN 4 way with provision for FP MCB/ Isolator/ RCCB etc as incommer and SP/TP MCBs as out going double door IP 43 complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply complete all as specified and as directed
S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system complete all as specified and as directed.
S & F for sheet metal enclosure MCB SPN DB way with 200 Amps rated bus bar 240 volts double door with magnitic locking system complete all as specified and as directed of following Size.
SPN DB 8 way
SPN DB 4 way
SPN DB 2 way
M&L for sub main wiring two single core multistranded PVC insulated copper conductor FRLS Cable of size 1.5 sqmm 1100 volt grade drawn into PVC conduit of size 25mm dia including 1.5 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note :- Two run of 1.5 Sqmm, one run of 1.5 sqmm earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for sub main wiring two single core multistranded PVC insulated copper conductor FRLS Cable of size 2.5 sqmm 1100 volt grade drawn into PVC conduit of size 25 mm dia including 2.5 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note :- Two run of 2.5 Sqmm, one run of 2.5 sqmm earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for sub main wiring two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC conduit of size 25 mm dia including 4 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note :- Two run of 4 Sqmm, one run of 4 sqmm earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for sub main wiring two single core multistranded PVC insulated copper conductor FRLS Cable of size 6 sqmm 1100 volt grade drawn into PVC conduit of sutaible size including 6 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note :- Two run of 6 Sqmm, one run of 6 sqmm earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for sub main wiring with four single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC conduit of suitable size including 4 sqmm PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note :- Four run of 4 Sqmm, one run of 4 sqmm earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for sub main wiring with four single core multistranded PVC insulated copper conductor FRLS Cable of size 6 sqmm 1100 volt grade drawn into PVC conduit of suitable size including 6 sqmm PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note :- Four run of 6 Sqmm, one run of 6 sqmm earth wire and one run of PVC conduit shall be measured as one unit length.
S & F in repairs MCB TPN rated capacity 40 / 63 Amps, 415 volts breaking capacity 16 KA complete all as specified and as directed.
S & F in repairs MCB TPN rated capacity 100 Amps 415 Volts 16 kA complete all as specified and as directed.
S & F in repairs MCB TP rated capacity 25 to 100 Amps, 415 volts breaking capacity 16 KA complete all as specified and as directed.
S & F in repairs MCB Single pole and neutral (SPN) rated capacity 6 to 32 A, 240 volts breaking capacity 10 KA complete all as specified and as directed.
S & F in repairs MCB Single pole (SP) rated capacity 6 to 32 A, 240 volts breaking capacity 10 KA complete all as specified and as directed.
Taking down carefully electric geysers of any make, type and capacity after disconnecting of electric and water connections, opening of bottom cover, checking of all parts and taking out copper / tank, checking of its leakage and removing the dust, brazing the leakage and painting of geysers with two coats of synthetic enamel painting replacement of worn out spares and resassembling complete geysers and refixing back its position all as directed. Note : Spares shall be measured and paid sperately under relevant item of this BOQ as supply only.
Supply only thermostats ISI maked as required at site for geyser of capacity 25/35/50 ltr of any make all as directed by Engr-in-Charge.
Supply only of safety valve/high pressure valve ISI marked as per site requirement or all as per directed by Engineer-in-Charge.
Supply only heating element of rating 1/1.5 KW as required at site including rubber washers all as specified and directed by Engr-in-charge.
Supply only heating element of rating 2 KW as required at site including rubber washers all as specified and directed by Engr-in-charge.
S & F in repairs of PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 cm long for cold water connection all as specified and directed by Engineer-in-charge.
S & F in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 CM long for hot water connection all as specified and directed by Engineer-in-charge.
S & F in repairs, non return valve 15 mm dia of brass, ISI marked all as specified and directed by Engineer-in-charge.
M & L for refixing of geysers of any capacity to walls by grouting with new nut,bolts and refiixng the geysers at a location directed by Engr-in-charge complete with all necessary pipe connections, testing.
S&F plug top 16 Amps flush type complete.
M & L for stop valve , cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm bore
Attending the complaints of non functional ceiling / exhaust / wall mounted fans of any sweep, repairing testing ceiling / exhaust / wall mounted fan without taking down by replacing fan conductor, regulator and connecting wire etc and making fan serviceable all as directed by Engineer-in-Charge. Note : Spare shall be measured and paid seperately as supply only under relevant item of this BOQ.
Taking down unserviceable ceiling fans of any make and type servicing, over hauling, oiling greasing the requisit parts and rectifying the defects including replacement of unserviceable parts and testing and reinstalling at same or any other location as directed at site by Engineer-in-charge. Notes: - (i). The unit rate is deemed to include the cost of taking down carefully fans from existing position after disconnecting electric connections, sealing cable ends, bringing to MES store yard and refixing in same as different locations after repair etc complete all as directed by Engineer-in-charge. (ii) Cost of major items such as wonding, ball bearing, gun metal bush, capacitors, canopy, blades and repair/ rewinding /painting etc shall be measured and paid separately under relevant item of this schedule as supply only. (iii) Minor items or works like tightening loose connections in switch, binding insulation tape to the naked wires, replacement of unserviceable clamps, nuts and bolts, split pins, rubber reel,greasing, washers, including flexible twin core copper wire of suitable size from existing ceiling rose to fan etc complete shall be provided without any extra cost and cost of these minor items or works shall be deemed to be included in the unit rate quoted rates against this item and nothing extra shall be paid on this account.
Supply only ball bearing(DE/NDE) to match the existing make suitable for 1200/1400 mm sweep ceiling fan complete all as specified and directed by Engr-in-charge. Make : SKF/NBC or equivalent
Supply only capacitor 2.5 mfd for ceiling fan all as specified and as directed by Engr-in-charge.
Supply only fan regulator suitable for 1200/1400 mm ceiling fans (electronics step type)
All as per item No 53 above but Exhaust Fan of sweep 275-450 mm
Supply only ball bearing to match the existing make suitable for 275-450 mm exhaust fan. Make : SKF/NBC or equivalent
Supply only capacitor 4 mfd for exhaust fan all as specified and as directed.
Supply & fix in repairs copper strip 20 mm x 3 mm complete with saddles and fixing screws for fitting the strip all as specified and directed by Engr In Charge.
Supply & fix in repair Aluminium strip 25 mm x 3 mm complete with saddles and fixing screws for fitting the strip all as specified and directed by Engr In Charge.
Supply & fix in repair Copper strip 32 mm x 6 mm complete with saddles and fixing screws for fitting the strip all as specified and directed by Engr In Charge.
Fixing only aluminium strip 25 mm x 3mm complete with saddles and screws for fitting the strip.
S&F in repair copper strip 20 mm x 3 mm complete with saddles and screws for fitting the strip.
S&F in repair GI strip 32 mm x 6 mm complete with saddles and screws for fitting the strip.
M&L for Air terminations single pointed Aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangements on roof including taking down old all as directed.
Supply & fix four pointed ( centre tip 150mm and side spike 75mm) copper spike lighting arrester heavy duty copper rod opf size 15 mm dia both end screwed for easy fitment and 1.5mtr long and heavy duty copper base plate duly drilled on four corners of size 75mm x 75mm ,with necessary fixing arrangement on Top/side of pole complete including taking down old all as spcified and directed by Engineer-in-charge.
Supply and fix test point terminal block made out of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex. head screw including taking down old all as spcified and directed by Engineer-in-charge.
Material & labour for fixing of 50mm bore GI Pipe medium grade galvanised 1.5 mrt. long fixed on wall with proper fixing and clamping of strip & 1.5 mtr to 300mm long copper/Aluminium lightening arrester rod with all fitting and fixed complete to wall or roof top of bldg. Note: Joints shall be made with welding to get proper conductivity
Material and labour for Earthing complete with GI earth plate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 2.25 metres below normal ground level connected to galvanised iron earth strip of size 32X6 mm by means of bolts check nuts and washers of brass/ bronge all as shown in electrical plate No 3 connecting to earthing test point all as specified and indicated and testing on completion including excavation earth work drilling holes for electrode, PCC pit in PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete. Note:- Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length. All the joints shall be made with welding to get proper conductivity. Rate required deemed to be including excavation by compressor machine or breaker for soft /disintegrated rock to required depth and results of earthing should be below 1 Ohm.
M & L for maintenenace/servicing including attending fault on call basis and repairs philiux / Meditech major with standard /LED OT light of capacity (140000Lux or as per exisiting) Make Phililux / Technomed, as prescribed in repairs and maintenance manual, including fixing/replacement of spare parts (if required). The maintenance schedule shall be under each OT (i) Dismantling the complete OT light fittings (ii) Checking and servicing/repair and maintenance of OT Lights (iii) After repairing/servicing/Maintenence, reinstallation, realignment of OT fittings Note:-(i) Spares requried for above maintenece will be measured and paid separeataly under relevant items of this BOQ as supply only. (ii) Servicing of the above item shall be carried out by the authorized service providers specially for OT light. (iii) Any break down during the contract period should be attended by contractor with in a day.
Supply only LED Panel with 19 LED bulb yellow and white combination with Teflon coated wire suitable for Modle HOSPI CT 5+5 HEX
Supply only Controller touch Panel suitable for Modle HOSPI CT 5+5 HEX
Supply only SMPS input 220 V AC output 24 V 5 amp DC suitable for Modle HOSPI CT 5+5 HEX
Hydraulic arm set with base plate suitable for Modle HOSPI CT 5+5 HEX
Supply only 30 Minute battery backup system unit suitable for Modle HOSPI CT 5+5 HEX
M & L maintenance /servicing including attending fault on call basis and repairs, Phililux Mobile OT light capacity Make: Phililux, as per prescribed in repqirs and maintenance manual, including fixing / repalcement of spare parts (if required). The maintenance schedule shall be under each OT (i) Dismantling the complete OT light fittings (ii) Checking and servicing/repair and maintenance of OT Lights (iii) After the repairing/servicing/Maintenence, reinstlltion realignment of OT fittings Note:-(i) Spares requried for above maintenece will be measured and paid separeataly under relevant items of this BOQ as supply only. (ii) Servicing of the above item shall be carried out by the authorized service providers specially for OT light of Philips make. (iii) Any break down during the contract period should be attended by contractor with in a day.
Supply only diffusers for for Phililux major with standard OT light Make: Philips or recommended by manufacturer or service provider.
Supply only Reflector for Phililum major with standard OT lights Make: Philips or recommended by manufacturer or service provider.
Supply only Bulb Holder for Phililum major with standard OT light Make: Philips or recommended by manufacturer or service provider.
Supply only Halogen Bulb 12 V 50 Watts for Philium major with standard OT light Make: Philipsor recommended by manufacturer or service provider.
Supply only filter glass for Phililum major with standard OT light. Make: Philipsor recommended by manufacturer or service provider.
Supply only Rotary Switch CL 05 for Phililux major with Standard OT light Make: Philipsor recommended by manufacturer or service provider.
Supply obly Rotary Switch CL 06 for Phililux major with Standard OT light Make: Philipsor recommended by manufacturer or service provider.
Supply only Condensor CL 01 for Phililux major with standar OT light Make: Philipsor recommended by manufacturer or service provider.
Supply only fuse holder and base for major with standerd OT light light Make: Philips or recommended by manufacturer or service provider.
Supply only Condensor CL 02 for Phililux major with standard OT lights Make: Philips or recommended by manufacturer or service provider.
Repair to CVT 12V 250 by replaceing following burnt items:- (i) Internal wiring as per existing size. (ii) Burnt MCB of existing capacity (iii) Replacment of multi tap, stepdown transformer of existing capacity, (iv) Trial and testing completely directed by Engineer in charge
Repair to CVT 12V 500 by replaceing following burnt items:- (i) Internal wiring as per existing size. (ii) Burnt MCB of existing capacity (iii) Replacment of multi tap, stepdown transformer of existing capacity, (iv) Trial and testing completely directed by Engineer in charge
Rewinding of ceiling fan motor of any type and make with approved quality of super enamelled copper wire as per original gauge and size including varnishing heating etc complete.
All as per item above but exhaust fan upto 450 mm sweep.
ONKAR ELECTRIC AND GENERAL STORE
metro electrical services
Sunhari Electricals
SHREE VAIBHAV ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .