| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.4 L+₹4.1 L (11.9%)Rejected-Finance | L2 | Rejected-Finance Bid Ok | |
| 3 | L3₹39.0 L+₹4.7 L (13.8%)Rejected-Finance | L3 | Rejected-Finance Bid Ok | |
| 4 | L4₹40.2 L+₹5.9 L (17.2%)Rejected-Finance A 46 ARYA NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L4 | Rejected-Finance Bid Ok |
Tender Value
₹38.7 L
EMD Value
₹77,500
Closing Date
22 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Alwar
GE Alwar
SPL REPAIR TO BLDG NO T2 T3 UNDER AGE BRII
2023_MES_634069_1
8207/E8
Open Tender
Civil Works
Item Rate
180 days
GE ALWAR
As per NIT
3 documents required · 3 mandatory
₹500
GE Alwar
₹77,500
Yes
23 Feb 2024
22 Dec 2023
24 Jan 2024
22 Dec 2023
22 Jan 2024
7 Jan 2024
22 Dec 2023 - 6 Jan 2024
Amount
Demolition cement concrete(unreinfored) as in ground floor and paving not exceeding 15cm thick below or above the ground level complete all as specified & directed.
Demolition of brick/Stone masonry work built in cement mortar or cement lime mortar including all quion arches complete all as specified & directed.
Taking down chowkhat with shutter without taking off shutter from the frame exc 1.5 Sqm and not exc 4 Sqm each complete all as specified & directed.
Taking down chowkats or frames with shutters (without taking off shutters frome the frames) n exc 1.5 but each complete all as specified & directed.
Dismantling of concrete post as in Roof truss/puline etc any section in any description and making good in disturbed portion complete all as specified & directed.
Dismantling AC/CGI/Fibre sheet (Corrugated,Semi corrugated etc) as in rooof etc complete as as specified
Excavation in post holes (soft/loose soil) each n.exc.0.5 cum, getting out, RFR in and ramming earth or broken rubble mixed wth earth around in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc. 50m complete all as specified & directed.
M&L PCC (1:3:6) type C-2, using 40 mm graded stone aggregate in foundation filling /mass concrete as in post hole complete all as specified & directed.
S&F for structural steel as in Trusses , pulines,rafter made of Hollow /square/rectangle/round section including necessary tee, angle, cleats including necessary cutting welding notching complete all as specified and directed
S&F for structural steel as in as in vertical member made of Hallow /square/rectangle/round section including necessary tee, angle, cleats including necessary cutting welding notching complete all as specified and directed
S&F plates (Plain or chequered ) Chanels square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified & directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet ready made ridge suitable for corrugated sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa with self tapping screws as specified and directed.
M&L for cutting holes in stone walls built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3, exc half brick & not nec one brick (Depth of embedded portion of hold fasts or lungs measured from the face of the jamb into the wall) complete all as specified & directed.
M&L PCC 1:2:4 type B1 (using 20mm graded aggregate ) to fill the gap between roof sheet and wall, both outer side and inner side complete all as specified and directed.
Dismantling wall and any type of ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness fixed to any type of frame including cover fillets complete all as specified.
M&L for suspended false ceiling system using 4 mm thick 'E' Board ceiling tiles classic/ designer as approved by GE of size 595 x 595mm (as approved by GE) fixed with and including galvanized iron powder coated GI Grid system suspended from ceiling with provision of galvanized wire 4 mm dia with butterfly clips and wall taping screw i, hold down clips for fixing the board to frame complete all as per manufacturer’s instructions, complete, all as directed and specified. (a) Size of grid - 600 x 600 mm. (b) Size of main Tee – 39 x 24 (c) Size of cross Tee – 29X34 (d) Size of wall angle – 22.20 x 22.20
S&F Granite (of any type ) work 18-20mm thick (table rubbed and polished) in steps, jambs, pillars ,window cills,cooking platforms and like (including cutting for fixing of WHB, Sink etc) in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl dismantling of old stone slab complete all as specified and directed.
M&L vitrified tiles (light shade) 8-10mm thick of size 600mmx600mm as in floor set and jointed in neat cement slurry and pointed in white./ colour cement to match the shed over and including 15mm thick screed bed in CM 1:6 incl dismantling old tiles complete all as specified and directed
All as per ser item No 19.00 but in skirting and dado including 10mm thick rendering cement mortar 1:4.
M&L non skid ceramic colour tiles 7 to 8mm thick area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 sqm set and jointed in neat cement slurry in floor and pointed in colour cement to match the sade of tiles including screed bed or bedding layer 15 mm thick in CM 1:6 including dismantling old tiles complete all as specified and as directed
All as per ser item No 21.00 but as in skirting includinf CM 1:4 10m thick
M&L walling of random rubble, uncoursed , well bonded bedded and solidly hearted, built in CM 1:4 compleete all as specified and directed
All as per ser item No 23.00 but except stone (old stone to be re used in this items)
Racking out joint from random rubble masonry brought up to uncourse complete all as specified & directed.
Taking down cement plaster in any description including racking out joints and hacking for key scrubbing down with water complete all as specified and directed
M&L15mm thick rendering in cement mortar 1:4 on other than fair faces of Brick/stone masonry surace rendering is to be even and smooth with out using extra cenent complete all as specified and directed
M&L15mm thick rendering in cement mortar 1:6 on fair faces of brick work surace rendering is to be even and smooth with out using extra cement complete all as specified and directed
M&L for Rough cast plaster on exterior walls applying the under coat of cement and sand morrtar 1:3 not less than 10mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (size between 6 to 12mm ) mixed with coarse sand and cement in the raio of 1:1:1 shall be applied and finished even. The mix of cement and sand shall made slightly wetter than normal for rendering to ensure that larger aggregate are thoroughly covered complete all as specified and directed by Engineer in Charge
M&L 75mm thick cement concrete 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in plinth protection/path laid in panel surface finished even and fair with out using extra cement including filling the 6mm wide joints shall be laid between panels and junction of wall. The joints shall be filled with Bitumenous masic (1:3) 1 part of cement and 3 part of sand complete all as specified and as directed
M&L chequered cement concrete (coloured) tiles 30cmx30cm x25mm thick with (Lacquer/glossy finish) set and jointed in neat cement slurry in floor and pointed with grey cement and pigment including cement mortar screed bed 1:4, 20mm thick complete all as specified and directed
M&L preparation of newly plasterd surface of wall and applying two coats oil bound distemper over and including 1mm thick JK Birla putty complete all as specified and directed
M&L preparation of newly plasterd surface of wall and applying two coats cement base paint over a coat of primer complete all as specified and dircted
M&L complete removal of old existing surface by washing rubbing of wall and applying one coat cement base paint over a coat of primer complete all as specified and dircted
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efforsecent salt, trading oil grees spots etc using grinding machine on wall surfaces and preparation of old plastered wall surfaces and applying two coats of oil emulsion distemper ( OBD) of approved shed/tint over and including a coat of white wall care putty 1 mm thick complete.over a coat of primer .
S&F powder coated aluinium door anodised of approved colour( size of frame : 63.5mx38.10mmx2mm thick & size of shutter : door vertical (style ) with gasket of size 46.3mmx45.00mmx 1.50mm thick, top rail of size 47.00mmx45.00mmx1.30mm lock rail/middle rail 83.00mmx44.50mmx1.65mm thick bottom rail 114.3mmx45.00mmx1.50mm thick including S&F of 4.8 mm thick sheet glass with glazing clip, pvc track gasket ,EPDM rubber gasket on glass of weather tightening alongwith recessed type handle, hingees, mortic lock, door closer complete all as specified as per TD -2004/61R sheet No 1/1
S&F powder coated aluinium window having three track section 92mmx31.75m shutter section 40mmx18mm mounted on bearing to slide on track plain anodised of approved colour including S&F of 5 mm thick frosted/plain glass and wire mesh with glazing clip, pvc track gasket ,EPDM rubber gasket on glass of weather tightening alongwith recessed type handle and lock including sealing gap with marble /granite surface with silicon sealent aking it water proof in all manner including aluminium grill complete all as specified and directed by Engineer in Charge .
S&F decorative ultra slim liner LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient suitable for 16 Watt to 20 Watt with LED tube of model E-LITE LED Pride Plus and connecting up with and including three core, PVC insulated, sheathed copper conductore cable of required size and length from ceiling rose to fitting complete all as specified & directed. Make :- Havells Cat Part No LHEXBHP71NW018 or equivalent of Philips/ Crompton Greaves /Bajaj/Wipro.
Excavation in trenches n.exc 1.5M wide and n.exc 1.5M in depth for foundation and getting out in soft/loose soil all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Returning filling in, including spreading, levelling, watering and well ramming in layers n.exc. 25cm deep as in soft/loose soil copletete all as specified.
S&F PVC white cover plate with frame 1 Module
S&F PVC white cover plate with frame 2 Module
S&F PVC white cover plate with frame 3 Module
S&F PVC white cover plate with frame 4 Module
S&F PVC white cover plate with frame 6 Module
S&F PVC white cover plate with frame 8 Module
S&F modular metal flush box 1 Module
S&F modular metal flush box 2 Module
S&F modular metal flush box 3 Module
S&F modular metal flush box 4 Module
S&F modular metal flush box 6 Module
S&F modular metal flush box 8 Module
Taking down carefully copper/aluminium point wiring for one light/socket/power point and taking down of teak wood batten/ PVC casing caping and making good disturbed surfaces of walls/ ceiling/ floors etc including dismentling of fittings.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS and including wooden boxes fixed on wall with and including 3mm thick phenolic laminated sheet top cover for mounting switches, sockets, fan regulators etc complete all as specified.
All as per serial item No 55.00 here-in-before but for one fan/ceiling fan point controlled by one switch and regulator.
All as per serial item No 55.00 here-in-before but for one bell buzzer point controlled by one switch and regulator.
All as per serial item No 55.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board.
All as per serial item No 55.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
All as per serial item No 55.00 here-in-before but for one light point controlled by two, two way switches.
All as per serial item No 55.00 here-in-before but for one 3 pin socket outlet 15/16 Amps controlledby one 15/16 Amps switch on independent board with 2.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour.
All as per serial item No 55.00 here-in-before but for one 3 pin socket outlet 15/16 Amps controlledby one 15/16 Amps switch on independent board with 4.00 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour.
S&F switch piano flush type, single pole, one way, 5/6 Amp, 250 Volts module type complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 15 Amp, 250 Volts module type complete all as specified and directed.
Supply and fixing sheet metal enclosures single door type suitable for fixing MCB's, SPN with 200 Amps rated bus bar,2 way, 240 Volts.
S&F AC box signle plie and neutral elcolsure with a two pin and socket complete with one single pole MCB 240 volts, 32 Amps
S&F switch piano flush type, single pole, two way, 5 Amp, 230 Volts module type complete all as specified and directed.
S&F socket outlet for 3 pin (with 2 pin outlet also), 5/6 Amp, flush type 240 Volt module type complete all as specified and directed.
S&F socket outlet for 2 in 1, 3 pin 5 & 15 Amp, flush type 240 Volt module type complete all as specified and directed.
S&F modular bell push , 5 Amp 240 Volts complete all as specified and directed.
S&F bell/buzzer AC 230 Volts single pole complete all as specified and directed.
S&F ceiling rose surface Bakelite 65x50mm two or three terminals complete all as specified and directed.
S&F LED 16 Watt ultra slim edge 2x2 feet lit panel in aluminium casing recess mounted square fixture in white finsh suitable for low ceiling height, 3 in 1 , 3K, 4K, 6K with & including LED previred and connecting up dismantling of old unsv recessed mounted light. Make : Havells Cat Part No LHEXBHP71NW018 or equivalent of Philips/ Crompton Greaves/Bajaj/Wipro.
S&F in repair adore LED lamp 9/10 watt complete all as specified and directed. Make : Havell's/Crompton/ Syska.
Supply and fixing Adore LED lamp of 9/10 watt including taking down old u/s CFL lamp complete all as specified & directed. Make :- Havells cat part No. LHLDERHEML8X010 or equivalent of Philips / Crompton Greaves / Wipro/Bajaj
S&F stepped type electronic fan regulator, module type and connecting up ISI marked 240 volts complete all as specified & directed.
S&F sheet metal enclosures, double door type, suitable for fixing MCB SPN with 200 Amps rated bus bar, 8 way, 240 volts complete all as specified and directed.
Supply and fixing sheet metal enclosures single door type suitable for fixing MCB's, SPN with 200 Amps rated bus bar,4 way, 240 Volts.
S&F MCB 63 Amps, single pole & neutral, 240 Volts complete all as specified and directed. Make : Legrand/Havells/ABB
S&F MCB 32 Amps, single pole & neutral, 240 Volts complete all as specified and directed. Make : Legrand/Havells/ABB
S&F MCB 6-32 Amps, single pole, 240 Volts 'C' curve, 10KA, ISI marked as per IS/IEC 60898-1 2002 complete all as specified and directed. Make : Legrand /Havells /ABB
S&F sub main wiring on including passing throuh PVC conduit pipe 1100 volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 Sqmm and continuous earth with PVC flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm of green colour confirming to IS 694/1990 including taking down existing unserviceable sub main wiring. (Note : Two runs of cable with one run of earth wire and one run of PVC casing caping should measured as one length).
Supply, laying, jointing and testing XLPE insulated, armoured, heavy duty LT underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 50 sqmm 3.5 core laid in trenches, along poles through pipes etc complete all as specified & as directed. Note : (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately including taking down old unserviceable XLPE cable. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M&L for brick work with fly ash bricks {As per IS-13757 (1993) burnt clay fly ash building bricks}, (Old size bricks) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection complete all as specified & directed.
M&L dry sand (Tibba sand) and punning for cushioning to under ground cable all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/ Test point /panel / equipment and testing on including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed.
Taking down & Refixing of ceiling fan complete of any sweep 240V, AC and connecting up with necessary wiring of 3 core flexble copper wire, complete all as specified and directed.
Boring of holes under road, payment hard standing by trench less technology unsing ultra sound technique and necessary amchine including supply and fixing HPDE pipe of 80mm bore suitable for 0.4 mpa working pressure all as specified and directed
S&F LED type street DRACO SERIES light luminaire 20 watt 230 V 50 Hz including all necessary fitting accessories and LED complete all directed. Make :- C&S Cat Part No LTESS WLED or equvalent Crompton Freaves /Wipro
S&F cubical metallic box of size 1.0 Mtr X 0.9 Mtr X 0.30 M depth made out of 2 mm thick mild steel sheet, fron openable double door type with locking arrangment with and including 3 mm tgick plain sheet clear glass of suitable size fixed to facilite meter reading, all internal and external steel surfaces painted wityh two costs of synthetic enamel paint over a coat of red oxide primer, internal wiring with PVC insulated single core multistranded copper conductor FRLS cable IS-694 marked of adequate size but not less than 6 Sq mm with proper ferrule and cable gland, box shall be fixed on wall with 'Anchor' type/fastner type bolts & nuts (Set of 6 bolts of 12 mm dia 200mm long with nuts and washer) frouted into the wall properly to hold the box, writing MES/Qtr No for each energy meter with thick whit synthetic enamel paint, neoprene rubber gasket shall be provided for proper sealing, including bos shall have arrangement for fixing electric energy meter- 04 Nos, MCB DB SPN 2 way -04 Nos, MCB DB SPN 4 way -01 Nos complete all as dirtected. Note :- (a) Existing Electric meter -04 Nos will be taking doen carefully and refixing the same inside the new meter box carefully incl necessary electric connections and sealing the elcectric meter, and MCB DB SPN 4 Way and MCB DB SPN 2 Way shall be measured and paid for separately under relevent items of this dchedule. (b) The cubical box shall be fix inside (concelled) the existing wall by necessary cutting/frouting the wall and make good the distrubed surfaces be applying cement.
RAMJI LAL & SONS
M/S GAURI CONSTRUCTION
M/s ASK Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .