| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹57.3 L+₹5.4 L (10.4%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category i.e. b(i) as work pertains to external electrification |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
22 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS REPLACEMENT OF EXTERNAL ELECTRIC SUPPLY DISTRIBUTION SYTEMS AND CONNECTED ALLIED WORKS AT OLD BT III NEW TB III FMME TOC POC ASSAYE LINES MEG OFFRS MESS AREA AND MEG CENTRE UNDER GE NORTH BANGALORE
2021_MES_465641_2
8243
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE North Bangalore
Class D category b(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹90,000
Yes
8 Nov 2021
8 Sept 2021
29 Sept 2021
8 Sept 2021
22 Sept 2021
10 Sept 2021
8 Sept 2021 - 9 Sept 2021
90 days
Amount
Excavation in trenches in hard/dense soil not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in deep and not exc. 3.00 mtr deep for cable and getting in hard/dense soil complete all as specified and as directed.
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard / dense soil etc complete as specified as directed.
Removing the excavated material to a distance not exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complee all as specifeid and as directed.
Sand cushioning in layers for cables in trenches / ducts for cable using dry river sand including consolidation complete all as specified and directed. NOTE: Punned thickness will be measured for payment purpose.
Bricks, sub class 'B' of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq.mm 2 core connected with suitable lugs, gasket including taking out the existing unserviceable cable all as specified and as directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq.mm 4 core connected with suitable lugs, gasket including taking out the existing unserviceable cable all as specified and as directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq.mm 2 core connected with suitable lugs, gasket including taking out the existing unserviceable cable all as specified and as directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq.mm 4 core connected with suitable lugs, gasket including taking out the existing unserviceable cable all as specified and as directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq.mm 3.5 core connected with suitable lugs, gasket including taking out the existing unserviceable cable all as specified and as directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq.mm 3.5 core connected with suitable lugs, gasket including taking out the existing unserviceable cable all as specified and as directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq.mm 3.5 core connected with suitable lugs, gasket including taking out the existing unserviceable cable all as specified and as directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq.mm 3.5 core connected with suitable lugs, gasket including taking out the existing unserviceable cable all as specified and as directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq.mm 3.5 core connected with suitable lugs, gasket including taking out the existing unserviceable cable all as specified and as directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq.mm 3.5 core connected with suitable lugs, gasket including taking out the existing unserviceable cable all as specified and as directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq.mm 3.5 core connected with suitable lugs, gasket including taking out the existing unserviceable cable all as specified and as directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq.mm 3.5 core connected with suitable lugs, gasket including taking out the existing unserviceable cable all as specified and as directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq.mm 3.5 core connected with suitable lugs, gasket including taking out the existing unserviceable cable all as specified and as directed.
Rollled mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections of mild steel channel / angle iron / flat iron / round section of any size including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including dismantling the existing and inclusive of one red oxide primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and as directed
Pin type porcelain, vitreous white or brown insulator including one galvanized mild steel spindle, two galvanized iron washer and galvanized iron nut, size of insulator 100 mm height and 65mm dia suitable for 1100 volts grade supply including dismantling the existing complete all as specified and as directed.
Shackle type porcelain, vitreous white or brown insulator including one galvanized mild steel spindle, two galvanized iron washer and galvanized iron nut, size of insulator 75 mm height and 90mm dia suitable for 1100 volts grade supply including dismantling the existing complete all as specified and as directed.
Stay assembly complete with all accessories as shown in electrical plate No 1 of SSR Part-I consisting of stay rod 20mm dia, 1.80 mtr long stay plate 230 x 230 x 6 mm with nuts, bolts, insulator stay clamps etc.,complete all as shown on drawing and as directed. NOTE:-Excavation, stay wire, loop type insulator, stay clamps, excavation and concrete shall be measured separately.
Galvanised stay strand, 7/4mm complete all as specified and direccted.
Loop type insulator, vitreous porcelain, white, brown or green with overall dimensions 65 x 90mm, clearance of hole 16mm all specified and as directed.
Galvinised iron tubing, light grade, 50mm bore with all accessories for cable protection fixed on poles/buildings or laid in trenches including necessary MS clamps, bolts and nuts etc., including taking down the existing complete all as specified and as directed.
Galvinised iron tubing, light grade, 80mm bore with all accessories for cable protection fixed on poles/buildings or laid in trenches including necessary MS clamps, bolts and nuts etc., including taking down the existing complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr, connected to galvanized strip 25 x 4 mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No. 3 of SSR Part-I 2010 and as specified or indicated including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast RCC slab 40mm thick in Reinforced Cement Concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe wire mesh and lugs, including test point and testing on completion complete all as specified and as directed.
Replacemet of un serviceable existing /suitable size MCCBs 4 pole 415 Volts 50Hz including complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape as under:- (a) MCCB 63 to 100 Amps 16 KA with fixed thermal and magnetic settings.
(b) MCCB 160 Amps, 16 KA with fixed thermal and magnetic setting
(b) MCCB 200 Amps 25 KA with fixed thermal and magnetic setting
(c) MCCB 250 Amps 36 KA adjustable type with thermal and magnetic setting
(d) MCCB 400 Amps, 36 KA adjustable type with thermal and magnetic setting
(e) MCCB 125 Amps 25 KA, TP fixed type with thermal and magnetic setting
(f) MCCB 160 Amps 25 KA, TP fixed type with thermal and magnetic setting
(g) MCCB 200 Amps 36 KA, TP fixed type with thermal and magnetic setting
(h) MCCB 250 Amps , 36 KA, TPN adjustable type with thermal and magnetic setting
LT 2 line separator, 230 volts, 50 Hz including dismantling the existing complete all as specified as directed
LT 4 line separator, 415 volts, 50 Hz including dismantling the existing complete all as specified as directed
Cable jointing kit suitable for 1.1KV grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core / 4core XLPE armoured aluminium conductor cable including taking down the existing for following sizes:- (a) 3.5 core x 25 to 35 sq.mm.
(b) 3.5 core x 50 sq.mm.
(c) 3.5 core x 70 sq.mm.
(d) 3.5 core x 95 sq.mm.
(e) 3.5 core x 120 to 240 sq.mm.
Painting of steel tubular poles of any height and type, including security light mounting brackets with one coat of aluminium paint with painting black and white strip or as ordered by Engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering with writing letters or figures(Block), height not exc. 30 cm & letters or figures n.exc. 10 Nos complete all specified and as directed.
Painting of PCC poles of any height and type with two coat of cement based paint with painting black and white strip or as ordered by Engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering with writing letters or figures(Block), height not exc. 30 cm & letters or figures n.exc. 10 Nos complete all specified and as directed.
Boring of holes under road, pavement, hard standing by trenchless technic and nessary machine including inserting of HDPE pipe of bore 100mm dia, suitable for 0.40 Mpa working pressure including excavation at ends complete all as specified and as directed.
GI pipe bracket made of 25mm bore light grade GI pipe1.0 mtr long suitably bent to shape and fixed on wall/ pole for fixing street light fitting with 2 Nos suitable MS clamps of size 25 x 3 mm size incluiding bolts, nuts, washers all as specified and as directed.
GI pipe bracket made of 40mm bore light grade GI pipe1.0 mtr long suitably bent to shape and fixed on wall/ pole for fixing street light fitting with 2 Nos suitable MS clamps of size 25 x 3 mm size incluiding bolts, nuts, washers all as specified and as directed.
Dismantling of ACSR (Aluminium conductor steel reinforced) conductors all as specified and as directed.
ACSR (Aluminium conductor steel reinforced) conductor of any size on poles including binding wire of appropriate size complete including clearing of path and branch cutting of trees etc., all as specified and as directed
Refixing /Restringing of existing ACSR conductor connected with new existing wire tightening to insulator including line clearance by pruning of tree branch approx 1 m apart from conductor and tightening the sides complete all as specified and as directed.
Dismantling the unserviceble / damaged PCC/RCC / steel tubular poles of any size uncluding dismantling the foundation concrete and with proper finishing of the site all as specified and as directed.
Steel tubular poles complete with cast iron plate, finial tapper plug, bolts nuts & screws as per type 410 SP -31, 9 mtr long complete all as specified and as directed.
FRP moulded junction box with IP 65 protection of size 300x200x80mm with 32 Amps 4 way heavy duty terminal block with 6 Amps MCB SP and two number of cable entry gland of standard size with suitable MSclamps to fix with pole complete including taking down the existing complete all as specified and as directed.
LED street light fitting 1x60 Watt with prssure die cast housing along with prismatic polycarbonate modular secondary lens , IP- 66 degree of protection, high power LED 6000 K CCT etc suitable for primary roads all as per Bajaj Cat No: ENXT P 60 L WW CRPC SD or techno commercially equivalent make in Havells/ Wipro including taking down the existing complete all as specified and as directed.
LED street light fittings 1x90 Watt with prssure die cast housing along with prismatic polycarbonate modular secondary lens, IP- 66 degree of protection, high power LED 6000 K CCT etc suitable for primary roads all as per Bajaj Cat No: BRTFG 90 W LED CR or techno commercially equivalent make in Havells/ Wipro including taking down the existing complete all as specified and as directed.
Replacement of driver for LED street light of the following capacity including taking down the street light fittings, dismantling, re assembling and refixing to the pole with nuts and bolts etc all as specifed and directed for:- (a) Capacity of 90 Watt.
(b) Capacity of 60 Watt.
(c) Capacity of 40/45 Watt.
(d) Capacity of 30/25 Watt.
Plain Cement Concrete, (1:3:6), type C1 using 20mm graded stone aggregate in copping of poles/filling road cutting, stays, including necessary form work all as specified and as directed.
Plain Cement Concrete, (1:4:8), type D2 using 40mm graded stone aggregate as in pole foundation, stay assembly ,including necessary form work all as specified and as directed.
Repairs to APFC panels by opening of the panel, disconnecting all electric supply, replacing of the damaged wiring, including rewiring replacement of unserviceable parts etc all as specified and directed.
Replacement of power capacitor heavy duty can type, 440 Volts, various type of the following capacities all as specified and as directed :- (a) 5 KVAR Capacity.
(b) 7.5 KVAR caapcity
(c) 10 KVAR Capacity.
(d) 15 KVAR capacity.
(e ) 20 KVAR Capacity.
Power contactor, three phase, 18 Amps with 2 NO + 2 NC integrated aux contacts 3 phase including taking down the existing complete all as specified and as directed.
Power contactor three phase, 32 Amps with 2 NO + 2 NC integrated aux contacts, 3 phase including taking down the existing complete all as specified and as directed.
Power contactor, three phase, 50 Amps with 2 NO + 2 NC integrated aux contacts 3 phase including taking down the existing complete all as specified and as directed.
APFC unit for Auto Power Factor correction Digital type 8/6 stage 440 Volts Make Siemens/L&T/ Ducati including taking down the existing complete all as specified and as directed.
NO/NC contact/Add on block of various capacities all as specified and as directed.
Replacement CT 200A/5 all as specified and as directed
Replacement analog type ammeter range 0 - 200 A as specified and as directed.
Replacement analog type volt meter range 0 -500 Volts all specified and as directed.
Replacement Indicator lamp RYB/RRR-set of 03 -01 No all as specified and as directed.
PVC insulated Sheahed copper cable of size 2 core 2.5 sq.mm all as specified and as directed
LED lamps suitable for batten / pendent holder of luminous efficeincy 90/100 lm /watt, CRI ≥ 80, power factor above 0.95 suitable for indoor and out door application of capacity 40 watt all as specified and as directed.
LED flood light luminaries of 150 watt made of pressure die cast alluminium housing with toughned glass , high pressure LEDs and secondary lenses with IP-66 protection, 4 kV in built and 10 kV external surge protection etc all as per Model : BJFL 150 W LED off BAJAJ / LFLN-150CDL /60M of Crompton or equivaletn in Havells complete all as specified and as diretcted.
Repairs to high mast light of any capacity and height by operating the control gear, repair / replacement of unserviceable flood lights, rising the flood lights to the original position, testing and commissioning etc complete all as specified and directed. NOTE:- (i) Flood lights replaced will be measured and paid separately. (ii) Tools and equipment's required for the repair of high mast lights shall be provided by the contractor and the cost of the same shall be included in the quoted rate.
Off load change over switch of 100 Amps capacity three phase 415 Volts, 50 Hz all as per Indo Asian Model 0FFP0100 or techno commercially equivalent make in Standard / Havells including taking down the existing complete all as specified and as directed.
Busbar chamber out door type, with channel iron pedestal frame of 1.5 mtr height made out of 2.00 mm thick CRCA sheet steel, compartment type , dust proof, free standing, suitable for working on 440 Volts, 3 phase 50 Hz, AC supply, front and rear opening , hinged door, powder coated, IP 65 protection, cable alley, cable entry hole at bottom, earth strip 25 x4mm powder coated MS angle base frame of 45 x45 x40 mm of suitable length and height, for four Nos of outgoing cables and accomadationg four Nos of 200 Amps rated aluminium busbar, mounted inside the chamber with porecelain blocks, supports, provison of nuts , bolts etc for outgoing cable connection including 160 Amps 4 pole 25 KA MCCB as incomer including taking down the existing complete all as specified and as directed.
Repair to the existing LT Panels of any size and type by disconnecting all the electrical connections form the MCCBs / busbar, replace the damaged door with thickness and size of the existing type, fixed with hinges, replace the damagaed internal wirings , repaacement of the mounting frame / PCC paltform etc inluding painting the complete panel with two coats of the ivory colour paint using spary painting method complete with all as speciifed and as directed. NOTE:- Replacement of the items like MCCB / Change over switch etc will be measured under relevant items.
Timeline distribution board consisting of digital time switch of 230 Volts, 32 Amps, 3 pole contactor and MCB TPN 40 Amps etc internally pre wired with suitable size of wires and connectors fitted on the pole with GI clamps of size 20 x5 mm fitted with, nut and bolts including connection of IN and OUT all as per Model No: TL032080 of Indo Asian or techno commercially equivalent makes in Havells / Legrand all as specified and as directed.
LED Bollard landscape luminaries, cylindrical shape with opal acrylic diffuser and IP -66 protection of capacity 9 watt all as per Bajaj Cat No. BGBOL 605 9 Watt LED or techno commercially equivalent makes specified here in after including taking down old unserviceable light fittings complete all as specified and as directed.
New generation 25 Watt post top light fittings including lamp, energy saving IP-65 enviornmental friendly long life with symmetrically light distribution, spun aluminium with high power LED all as per Havells Cat No. CORAL PT 25W LED 757 PSYMTOPC or or techno commercially equivalent makes specified in PS all as specified and directed.
Vertical DB, VTPN with MCCB as incomer, 4 ways, double door with provision for TP MCCB 125 Amps, 16 KA as incomer, IP 43 protection, conforming to IS-13032, universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides all as per INDOASIAN OPTIPRO Cat No.811888 or techno commercially equivalent makes in Standard / Legrand / L&T all as specified and directed.
Supply, installation, testing and commissioning of LT feeder pillar box of suitable size , CPRI approved, outdoor type, floor mounted with channel iron pedastal frame mounting made out of 3.15 mm thick CRCA sheet steel and MS Angle Section 40 X 40 X 6 mm base frame, compartmental type, dust proof, free standing, suitable for working on 440 Volts, 3 phase 50 Hz, AC supply, vermin proof, front and rear opening, hinged doors etc powder coated as per seven tank process, and IP 65 protection, cable alley, cable entry hole at the bottom, earth strip 25 X 4 mm, 3 phase and neutral copper bus bar of 300 Amps with non adhesive colour coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts, bolts and washers, PCC works complete with copper strips of suitable size for connecting MCCB complete comprising of including supply and fixing of the following all as specified and directed:- Contd...1.092
Contd...1.091 INCOMER: (a) MCCB 4 Pole, 400 Amps with ultimate breaking capacity, Icu-36 KA at 415 Volts and adjustable thermal magenetic release - 01 No OUTGOING: (a) MCCB 4 Pole, 200 Amps with ultimate breaking capacity, Icu-36 KA at 415 Volts and adjustable thermal magenetic release- 04 No (b) Digital Ammeter 0 to 100 Amps and 3 CT's Class 1.0, 10 VA - 1 Set (c) Digital Voltmeter 0-500 V with 7 position and 2A HRC fuses/MCB's - 1 Set (d) LED phase indication lamps R,Y,B for incomer and outgoing switches
Two runs of PVC insulated 2.5 sqmm single core multistranded copper conductor cable and one run of 2.5 sqmm copper wire as earth continuity conductor all as specified and as directed. NOTE:- Two runs of cable and one run of earth wire shall be measured as one length.
Supply, installation, testing and commissioning of LT feeder pillar box of suitable size, CPRI approved, outdoor type, floor mounted with channel iron pedastal frame mounting made out of 3.15 mm thick CRCA sheet steel and MS angle section 40 X 40 X 6 mm base frame compartmental type, dust proof, free standing, suitable for working on 440 volts 3 phase 50 Hz AC supply, vermin proof, front and rear opening, hinged doors etc powder coated as per seven tank process, and IP 65 protection, cable alley, cable entry hole at the bottom, earth strip 25 X 4 mm, 3 phase and neutral copper bus bar of 300 Amps with non adhesive colour coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts, bolts and washers, PCC works complete with copper strips of suitable size for connecting MCCB complete comprising of including supply and fixing of the following all as specified and directed:- Contd...1.095
Contd...1.094 INCOMER: (a) MCCB 4 Pole, 250 Amps with ultimate breaking capacity, Icu-36 kA at 415 Volts and adjustable thermal magenetic release - 01 No OUTGOING: (a) MCCB 4 Pole, 125 Amps with ultimate breaking capacity, Icu-36 kA at 415 Volts and adjustable thermal magenetic release- 02 Nos (b) Digital Ammeter 0 to 300 Amps and 3 CT's Class 1.0, 10 VA - 1 Set (c) Digital Voltmeter 0-500 V, with control MCBs - 1 Set (d) LED phase indication lamps R,Y,B for incomer and outgoing switches
Supply, installation, testing and commissioning of LT feeder pillar box, CPRI approved, outdoor type, floor mounted with channel iron pedastal frame mounting made out of 3.15 mm thick CRCA sheet steel and MS Angle Section 40 X 40 X 6 mm base frame, compartmental type, dust proof, free standing, suitable for working on 440 volts 3 phase 50 Hz AC supply, vermin proof, front and rear opening, hinged doors, powder coated as per seven tank process, IP 65 protection, cable alley, cable entry hole at the bottom, earth strip 25 x 4 mm, 3 phase and neutral copper bus bar of 300 Amps with non adhesive colour coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts bolts and washers, PCC works complete with copper strips of suitable size for connecting MCCBs complete comprising of including supply and fixing of the following all as specified and as directed:- Contd...1.097
Contd...1.096 INCOMER: (a) MCCB 4 Pole, 160 Amps with ultimate breaking capacity, Icu-25 kA at 415 Volts and adjustable thermal magenetic release - 01 No OUTGOING: (a) MCCB 4 Pole, 1+E6300 Amps with ultimate breaking capacity, Icu-36 kA at 415 Volts and adjustable thermal magenetic release- 02 Nos (b) Digital Ammeter 0 to 200 Amps and 3 CT's Class 1.0, 10 VA - 1 Set (c) Digital Voltmeter 0-500 V with suitable control MCB's - 1 Set (d) LED phase indication lamps R,Y,B for incomer and outgoing switches. NOTE FOR Sl ITEM NO. 1.091,1.093 AND 1.094 :- serviciable MCCBs are deposited to MES store for purpose of reuse.
Fixing only MCCBs reterived from SL Item No 1.090, 1.092 and 1.093 above on existing LT panels complete all as specified and as directed.
Sheet metal enclosure / junction box of size 800x800x300 mm, out door type, double door with aluminium bus bar of 250 Amps for 3 phase & neutral, MCCB 4 pole, 415 Volts, 125 Amps, 36 KA including removing old unserviceable junction box complete all as specified and as directed.
Sheet metal enclosure / junction box of size 800x800x300 mm, out door type, double door with aluminium bus bar of 250 Amps for 3 phase & neutral, MCCB 4 pole, 415 Volts, 100 Amps, 25 KA including removing old unserviceable junction box complete all as specified and as directed.
Sheet metal enclosure / junction box of size 800x800x300 mm, out door type, double door with aluminium bus bar of 160 Amps for 3 phase & neutral, MCCB 4 pole, 415 Volts, 100 Amps, 16 KA including removing old unserviceable junction box complete all as specified and as directed.
Timeline distribution board 16 Amps, 3 pole / 230 Volts, analog time switch including complete accessories relay contactor, timer etc, all as per Indo Asian Cat No. TL016AB0 or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Cable fault finding in LT cables any sizes complete all as specified and as directed
On load Change over switch four pole in sheet metal enclosure, compact design of rating100 Amps suitable for isolation and prevent leakage current / flush over between phases, handle lock feature in off position with three padlocks all as per INDOASIAN Cat No. ITAS0100 or techno commercially equivalent makes specified in PS complete all as specified and as directed.
On load Change over switch 4 pole in sheet metal enclosure, compact design of rating 250 Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks all as per INDOASIAN Cat No.ICAS0250 or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Dismanling and taking down old unserviceable CFL type street light fittings from Pole, removing the unserviceable CFL and replacement of new LED bulb 40 watt and refixing the same in existing/new location all as specified and as directed.
K T ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .