| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC | ₹35.3 L Quoted ₹36.7 L | L1 | Accepted-AOC Accepted. Being the L1 bidder. |
| 2 | L2₹40.4 LRejected-AOC | ₹40.4 L | L2 | Rejected-AOC Rejected as not being the lowest bidder. |
| 3 | L3₹41.8 LRejected-AOC | ₹41.8 L | L3 | Rejected-AOC Rejected as not being the lowest bidder. |
| 4 | L4₹44.5 LRejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | ₹44.5 L | L4 | Rejected-AOC Rejected as not being the lowest bidder. |
| 5 | L5₹48.5 LRejected-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹48.5 L | L5 | Rejected-AOC Rejected as not being the lowest bidder. |
| Sl No | Description | Qty | Unit | NOEL ENGINEERS L1 | sapana enterprises L5 | SAI SERVICE L3 | R J ENTERPRISES L4 | industrial suppliers L6 | PAUL REFRIGERATION L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully unserviiceable copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. | 415 | Per Point | 15 ₹6,225 | 5 ₹2,075 | 8 ₹3,320 | 30 ₹12,450 | 25 ₹10,375 | 1 ₹415 |
| 2.00 | Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse). | 61 | Each | 10 ₹610 | 5 ₹305 | 5 ₹305 | 50 ₹3,050 | 20 ₹1,220 | 1 ₹61 |
| 3.00 | Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit with all fittings, accessories, PVC junction boxes etc. with and including concealed GI metal boxes 1.2 mm thick,(18 Guage) 50mm deep, with earth dolly, covered with modular white cover plate & frame of suitable module for mounting switches, sockets, regulators etc and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for One light point/ exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed. | 30 | Per Point | 900 ₹27,000 | 640 ₹19,200 | 550 ₹16,500 | 810 ₹24,300 | 850 ₹25,500 | 400 ₹12,000 |
| 4.00 | All as per description of item No 3 but One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed | 30 | Per Point | 150 ₹4,500 | 200 ₹6,000 | 150 ₹4,500 | 210 ₹6,300 | 250 ₹7,500 | 150 ₹4,500 |
| 5.00 | All as per description of item No 3 but One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed | 35 | Per Point | 900 ₹31,500 | 640 ₹22,400 | 550 ₹19,250 | 810 ₹28,350 | 850 ₹29,750 | 300 ₹10,500 |
| 6.00 | All as per description of item No 3 but One two way light point controlled by two nos. two way 6A switches complete all as specified and as directed | 10 | Per Point | 1,100 ₹11,000 | 640 ₹6,400 | 550 ₹5,500 | 850 ₹8,500 | 800 ₹8,000 | 300 ₹3,000 |
| 7.00 | All as per description of item No 3 but One bell point controlled by one, one way switch 6 Amps complete all as specified and as directed | 15 | Per Point | 900 ₹13,500 | 640 ₹9,600 | 650 ₹9,750 | 810 ₹12,150 | 800 ₹12,000 | 300 ₹4,500 |
| 8.00 | All as per description of item No 3 but One ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed | 20 | Per Point | 900 ₹18,000 | 640 ₹12,800 | 650 ₹13,000 | 810 ₹16,200 | 800 ₹16,000 | 300 ₹6,000 |
| 9.00 | All as per description of item No 3 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point, 6 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed. | 20 | Per Point | 1,400 ₹28,000 | 690 ₹13,800 | 900 ₹18,000 | 950 ₹19,000 | 900 ₹18,000 | 400 ₹8,000 |
| 10.00 | All as per description of item No 3 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed. | 20 | Per Point | 2,200 ₹44,000 | 940 ₹18,800 | 1,050 ₹21,000 | 1,100 ₹22,000 | 1,000 ₹20,000 | 460 ₹9,200 |
Updated dates
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 Jan 2026, 6:00 pmClosed
GE (NW) BHANDUP
GE (NW) BHANDUP, MUMBAI
PREVENTIVE MAINT AND REPAIR INTERNAL ELECTRIC SUPPLY INTERNAL POINT WIRING OF MD ACCN, INTERNAL WORK AT NCHC POWAI UNDER GE (NW) BHANDUP
2025_MES_746768_1
8464/B
Open Tender
Civil Works
270 days
NCHC POWAI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (NW) BHANDUP
₹90,000
Yes
3 Jun 2026
1 Jan 2026
30 Jan 2026
1 Jan 2026
29 Jan 2026
15 Jan 2026
1 Jan 2026 - 10 Jan 2026
Taking down carefully unserviiceable copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse).
Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit with all fittings, accessories, PVC junction boxes etc. with and including concealed GI metal boxes 1.2 mm thick,(18 Guage) 50mm deep, with earth dolly, covered with modular white cover plate & frame of suitable module for mounting switches, sockets, regulators etc and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for One light point/ exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed.
All as per description of item No 3 but One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed
All as per description of item No 3 but One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed
All as per description of item No 3 but One two way light point controlled by two nos. two way 6A switches complete all as specified and as directed
All as per description of item No 3 but One bell point controlled by one, one way switch 6 Amps complete all as specified and as directed
All as per description of item No 3 but One ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed
All as per description of item No 3 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point, 6 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed.
All as per description of item No 3 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed.
Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC casing caping with all fittings, accessories, PVC junction boxes etc fixed to walls/ceilings with and including concealed GI metal boxes 1.2 mm thick,(18 Guage) 50mm deep, with earth dolly, covered with modular white cover plate & frame suitable for mounting switches, sockets, regulators etc and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for One light point/ exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed.
All as per description of item No 11 here-in before but One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed
All as per description of item No 11 here-in before but One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed
All as per description of item No 11 here-in before but One two way light point controlled by two nos. two way 6A switches complete all as specified and as directed
All as per description of item No 11 here-in before but One bell point controlled by one, one way switch 6 Amps complete all as specified and as directed
All as per description of item No 11 here-in before but One ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed
All as per description of item No 11 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point, 6 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed
All as per description of item No 11 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed. Note for Item Ser No 3 to 18: (i) Cutting chases for conduits and sinking's for GI metal switch boxes and making good to walls in cement mortar 1:3 to match with existing surfaces shall be carried out by the contractor without any extra cost from the department. (ii) Partially partly wiring in casing caping with all fittings accessories PVC junction boxes whereever concealed wiring is not possible on the surfaces of RCC slab / ceiling /columns / beams etc shall deemed to be included in the unit rate quoted against item. (iii) Heat shrinkable sleeves to be used at joints wherever necessary. Rates for the the item are deemed to be included in the unit rate quoted against item.
Supply and fixing Modular switch, one way 6 A, one module, 230 Volts complete all as specified and as directed.
Supply and fixing Modular Bell push 6A ,one module 230 Volts complete all as specified and as directed.
Supply and fixing Modular switch, one way 16 A, one module, 230 Volts complete all as specified and as directed.
Supply and fixing Modular socket outlet multipurpose, 6A - 2/3 pin combined 2 module, 230 Volts complete all as specified and as directed.
Supply and fixing Modular socket outlet multipurpose, 6A/16A - 2/3 pin combined 2 module, 230 Volts complete all as specified and as directed.
Supply and fixing modular stepped type electronic fan regulator flush type, 120W - 2 module suitable for 230V 50Hz AC supply complete all as specified and as directed.
Supply and fixing modular stepped type electronic fan regulator flush type, 120W - 1 module suitable for 230V 50Hz AC supply complete all as specified and as directed.
Supply and fixing Switch piano, flush type, polycarbonate, single pole, one way 6 Amp complete all as specified and as directed.
Supply and fixing Bell push, flush type, polycarbonate, 6 amp complete all as specified and as directed.
Supply and fixing Switch piano, polycarbonate, flush type single pole, one way 16 Amp complete all as specified and as directed.
Supply and fixing Socket outlet switch socket outlet, 2-in-1, 6 pin, 6 and 16 Amps, flush type complete all as specified and as directed.
Supply and fixing Socket outlet 2 in 1, 5 pin, 6A complete all as specified and as directed.
M & L Switch socket combination 2 in 1, 6 pin, 6 A flush type complete all as specified and as directed.
M & L Switch socket combination 6A/16A, 6 in 1 flush type complete all as specified and as directed.
Supply and fixing stepped type electronic fan regulator flush type, 120W - 2 module suitable for 230V 50Hz AC supply complete all as specified and as directed.
Supply and fixing electric Buzzer, Ding Dong bell suitable for operation on AC. 230 volts, single pole complete all as specified and as directed.
M & L Ceiling rose, 3 terminal /PVC/ polycarbonate, isolated body complete all as specified and as directed.
M & L Fancy Lamp holder, PVC/ Polycarbonate type with back plate of brass terminal suitable for batten fittings complete all as specified and as directed.
Supply and fixing 6 Amps Top Plug with Indicator complete all as specified and as directed.
Supply and fixing 16 Amps Top Plug with Indicator complete all as specified and as directed.
Supply and fixing in repairs Modular white cover plate with frame, to true size of the existing concealed metal box & make as per site requirement of 3 Module
All as per description of item No 39 here-in before but 4 Module
All as per description of item No 39 here-in before but 6 Module
All as per description of item No 39 here-in before but 8 Module
All as per description of item No 39 here-in before but 12/16 Module
Supply and fixing in repairs GI metal flush boxes 1.2 mm thick, (18 Guage) 50mm deep, with earth dolly, suitable for mounting modular white cover plate of size 03 Module
All as per description of item No 44 here-in before but 4 Module
All as per description of item No 44 here-in before but 6 Module
All as per description of item No 44 here-in before but 8 Module
All as per description of item No 44 here-in before but 12/16 Module
Supply and fixing in repairs Plastic Surface Box -, with earth dolly, suitable for mounting modular white cover plate of size 3 Module
All as per description of item No 49 here-in before but 4 Module
All as per description of item No 49 here-in before but 6 Module
All as per description of item No 49 here-in before but 8 Module
All as per description of item No 49 here-in before but 12/16 Module
Supply and fixing 3mm thick white (Hylam) sheet for electrical application to incorporate switches, sockets etc including Cutting, drilling, shaping of material to site requirement and fixing with brass cadmium screws of adequate size and length complete all as specified and as directed. Note for Item Ser No 19 & 54 : (i) Item will also be exercised in repairs means Labour component involved in taking out existing unserviceable from its place and fixing new in position is deemed to be included in the unit rate quoted. (ii) Making good disturbed wall in cement mortar 1:3 , & with wall puti for concealing meatl box and painting wall surface as per existing finish shall be carried out by the contractor without any extra cost from the department.
S&F LED indoor decorative aluminum housing LED batten integrated type tube light fitting, suitable and including wattage 20W, rated input voltage 140V AC – 270V AC, driver efficiency 88%, Lumens efficiency 100 lm/W, starting voltage 90V, THD<=20, color rendering index (CRI).80, Color temperature 6500K, No harmful radiations, inbuilt surge protection 2.5 kV, isolation 3.75kV, Zero mercury content , complete with all accessories internally pre wired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes all as specified and directed.
S&F LED indoor decorative polycarbonate housing LED batten integrated type tube light fitting, suitable and including wattage 10W, rated input voltage 140V AC – 270V AC, driver efficiency 88%, Lumens efficiency 100 lm/W, starting voltage 90V, THD<=20, color rendering index (CRI).80, Color temperature 6500K, No harmful radiations, inbuilt surge protection 2.5 kV, isolation 3.75kV, Zero mercury content , complete with all accessories internally pre wired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes all as specified and directed. Note for Item Ser No 55 & 56 : (i) Item will also be exercised in repairs means Labour component involved in taking out existing unserviceable from its place and fixing new in position is deemed to be included in the unit rate quoted.
Supply and fixing amp rating 240V, 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of SP 6-32 Amp in the MCB DB complete with connection testing and commissioning.
Supply and fixing amp rating 240V, 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of SPN 32 Amp in the MCB DB complete with connection testing and commissioning.
Supply and fixing amp rating 240V, 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of SPN 40-63 Amp in the MCB DB complete with connection testing and commissioning.
Supply and fixing 415V 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of TPN 40-100 Amp capacity in the DB complete with connection testing and commissioning.
S & F sheet metal enclosure MCB SPN 4 Way suitable for Flush Mounting and Surface Mounting, MCB DB with Fully shrouded Neutral bars, Earthbar and Cable ties for Cable management, 240 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed.
S & F sheet metal enclosure MCB SPN 8 Way suitable for Flush Mounting and Surface Mounting, MCB DB with Fully shrouded Neutral bars, Earthbar and Cable ties for Cable management, 240 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed.
S & F sheet metal enclosure MCB SPN 12 Way suitable for Flush Mounting and Surface Mounting, MCB DB with Fully shrouded Neutral bars, Earthbar and Cable ties for Cable management, 240 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed.
Supplied and fixed Flush Mounting and Surface Mounting single pole and neutral sheet metal enclosure suitable for 240 V with neutral link, two pin, earth plug and socket plug top complete all as specified and as directed with One single pole MCB upto 20 Amps Note for Item Ser No 61 & 64 : (i) Item will also be exercised in repairs means Labour component involved in taking out existing unserviceable from its place and fixing new in position is deemed to be included in the unit rate quoated. (ii) Making good disturbed wall in cement mortar 1:3 , & with wall puti for concealing meatl box and painting wall surface as per existing finish shall be carried out by the contractor without any extra cost from the department.
Taking down carefully existing unserviceable main switch /cutout /DBs of any type, capacity and description and removing materials from site and making good disturbed surfaces of walls, floors as per the existing finishes all as specified and as directed.
Supply and fixing DPX³ 100 MCCB with O/L & S/C thermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 100 Amps, of Make Legrand Cat No 4200 57 or Equivalent in L&T
Supply and fixing DPX³ 63 MCCB with O/L & S/C thermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 63 Amps, of Make Legrand Cat No 4200 57 or Equivalent in L&T
Supply and fixing DPX³ 125 MCCB with O/L & S/C thermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 125 Amps, of Make Legrand Cat No 4200 56 or Equivalent in L&T
Supply and fixing DPX³ 160 MCCB with O/L & S/C thermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 160 Amps, of Make Legrand Cat No 4200 57 or Equivalent in L&T
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into PVC casing caping with all fittings, PVC junction boxes etc and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into PVC casing caping with all fittings, PVC junction boxes etc and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed
Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed.
S & F PVC rigid non-metallic conduit of dia 20 mm dia inclusive of all tees, bends, elbows reducers, junction box etc and fixing accessories such as couplers, lock nuts, saddles, etc for telephone cable , TV cable and public address system complete all as specified and directed by Engineer-in- Charge
S & F PVC rigid non-metallic conduit of dia 25 mm dia inclusive of all tees, bends, elbows reducers, junction box etc and fixing accessories such as couplers, lock nuts, saddles, etc for telephone cable , TV cable and public address system complete all as specified and directed by Engineer-in- Charge
Labour for taking down of unserviceable ceiling fan of any sweep and make after disconnecting cable end terninal from ceiling rose, dismantling blades and hanging serviceable fan at same location of any sweep, make by connecting cable end terminal to ceiling rose, after fixing blades at site with fan, testing for smooth running complete all as specified and as directed. Note : Transportation to & fro involved of unserviceable ceiling fan to deposit in EM Store yard Powai and back to site hanging serviceable fan after collecting from store is deemed to be included with unit rate.
Servicing / over hauling of ceiling fan 230 Volts of any make and sweep, along with following others repairs. a). Dismantaling of ceiling fan complete part by part carefully, testing stator coils, degreasing bearing and display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts b) Heating & varnishing to stator coils with super quality varnish and dried out properely with external heat as ordered & directed. c) Reassembeling of ceiling fan complete with all existing serviceable parts obtained against Item 1 (a), and new parts as required / ordered by Engineer in Charge. Note (i). Any Parts required for replacement shall be measured and paid seperately under appropriate item as ''Supply only'' (s) of this schedule. However labour element involved in replacement is included in unit rate quoated against this Item. (ii).Any unforeseen minor repair and minor parts that are not covered under Item No-86 , (a) to (c) (Total cost less than Rs 100 ) but required to complete the repair work / smooth functioning of fan shall be deemed to be included with the unit rate. (iii) Transportation of fan to workshop for repair and back to site in E/M store yard at Bhandup is deemed to be included with unit rate. (iii). Rewinding of stator coils of ceiling fan , where involved shall be measured and paid separetely against relevant item of this schedule. (iv) 3 core PVC insulated and sheathed 0.75 Sqmm cable from ceiling rose to fan connector of adequate length (maximum upto 1 Mtr) and (greasing the bearing with ball bearing grease where involved) shall deemed to be included in the unit rate.
S&F Ball bearing rubber sealed for bottom cover 6201 or as per existing
S & F Ball bearing rubber sealed for Top cover 6202 or as per existing
Material and labour for rewinding stator of ceiling fan 1200/1400 mm sweep with supper enameled copper wire of existing gauge, and testing complete all as specified and as directed.
M & L in replacement of ceiling fan capacitor 2.5 MFD with or without taking down the ceiling fan fixed at any height refixing in original Position after repaired and connecting up, complete all as specified and as directed.
M & L for taking out old paint of ceiling fan (any size) with paint remover liquid , Preparing smooth surfaces for painting, cleaning all dust etc, filling cavities with filler, and Painting of complete ceiling fans including blades with synthetic enamel white rust proof paint by spraying complete all as specified and as directed.
S & F Ceiling fan down rods cut to required length as per site requirement of 15 mm dia GI pipe (medium grade) to the existing trusses of any height including necessary welding, drilling holes complete all as specified and as directed.
Supply only gun metal bush suitable for ceiling fan of any sweep complete all as specified and directed.
Supply only shackle clip assembly with rubber bush reel and nuts, bolts and washers suitable for ceiling fan of any sweep complete all as specified and directed.
Supply only PVC canopy top and bottom with tighten screw suitable for ceiling fan of any sweepcomplete all as specified and directed.
Material and Labour for Radium Retro Reflective Vinyl Sticker, (Thickness 0.4mm,) water proof, wear resistant back with sticker, Resistant to fading, cracking, and peeling, colour as directed by Engnr-in- Charge, (for MES Property Inenfification) Numbering Fan any type, cut to customizable size font - Height not less than 20 mm and width not less than 15 mm with letters as - GE(NW) / E&M / CF /BLDG No/ QTR No/MES- 001 / complete all as specified and as directed. Note- Ser No i.e 001 will change on each ceiling fan as directed by Engnr-in- Charge.
Taking down and opening / dismantling of exhaust/ ventilation fan, 200/250/300 mm sweep and taking out old unserviceable winding and M & L for rewinding the same with super enameled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassembling, testing complete including spy painting with one coats of synthetic enamel paint after preparing rusted surface and re-fixing, testing and commissioning complete all as specified and directed by the Engineer-in-Charge. Note : Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items.
All as per above item No 91 but size for 450 mm sweep Exhaust fan.
Supply and fix bush Suitable for existing exhaust fan of 200/250/300 mm sweep all as specified and directed.
Supply and fix bearing Suitable for existing exhaust fan of 400 mm sweep all as specified and directed.
Supply and fix bush Suitable for existing exhaust fan of 400 mm sweep all as specified and directed.
Supply and fix bearing Suitable for existing exhaust fan 200/250/300 mm sweep all as specified and directed.
Supply and fix shaft Suitable for existing exhaust fan 200/250/300/400 mm sweep all as specified and directed.
Supply and fixing in repair 250/300 mm sweep PVC exhaust fan blade all as specified and directed.
Supply and fixing in repair exhaust fan motor 170 to 250V, 50 Hz (200 mm Sweep to 300 mm Sweep) suitable capacity and size all as specified and directed.
Supply and fixing in repair 250/300 mm sweep PVC exhaust lovers suitable for any size and model all as specified and directed.
Supply and fix capacitor 1.5 mfd capacity 230 volts all as specified and directed
Supply and fixing in repair 250/300 mm sweep 3 or 4 blade metal body fan blade suitable for any size and model all as specified and directed.
Supply and fixing in repair 250/300 mm sweep GI sheet exhaust lovers suitable for any size and model all as specified and directed.
Supply and fixing in repair 400 mm sweep GI sheet exhaust lovers suitable for any size and model all as specified and directed.
Supply and fixing in repair 400 mm sweep 4 blade metal body fan blade suitable for any size and model all as specified and directed.
Taking down and opening / dismantling of BLDC ceiling fan, 1200/1400 mm sweep and taking out old unserviceable winding and M & L for rewinding the same with super enameled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassembling, testing complete including spy painting with one coats of synthetic enamel paint after preparing rusted surface and refixing, testing and commissioning complete all as specified and directed by the Engineer-in-Charge. Note : Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items.
Supply and fixing in repair BLDC fan control electronic card for 1200 mm sweep ceiling fan as per model all as specified and directed.
Supply and fixing in repair BLDC fan electronic remote for 1200 mm sweep ceiling fan as per model all as specified and directed.
Supply and fixing in repair Modular AC Box With 25A SP MCB, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top complete all as specified and directed.
M & L for repair any type of defective electronic single Phase meter including any kind and type material and testing required complete all as specified and directed.
M & L for repair any type of defective electronic Three Phase meter including any kind and type material and testing required complete all as specified and directed.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and as directed.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover , 3 Phase 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and as directed.
Supply and fixing, fresh air (exhaust) fan plastic body of 250mm sweep, AC single phase, 240V, 50 Hz, Input Voltage, 140-285, , with louvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/M store yard Bhandup complete all as specified and directed.
Supply and fixing, fresh air (exhaust) fan plastic body of 200mm sweep, AC single phase, 240V, 50 Hz, Input Voltage, 140-285, , with louvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/M store yard Bhandup complete all as specified and directed.
Supply and fixing, fresh air (exhaust) fan plastic body of 150mm sweep, AC single phase, 240V, 50 Hz, Input Voltage, 140-285, , with louvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/M store yard Bhandup complete all as specified and directed.
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including GI strip 25×4 mm as earthing lead by means of bolts, nuts, checknuts and washers of galvanized iron or steel drawn through GI pipe 40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with precast RCC cover in CC 1:2:4 type B1 with handle , with G.I 20 mm dia medium grade pipe for watering and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion complete all as specified and as directed.
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts, check nuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion complete all as specified and as directed. Note for Item No 117 to 118. Item cost includes cost of dismantling unserviceable earthing pit above ground level with earthing electrode and making good as per existing ground.
S & F in repairs heating element of 1.5 kw / 2.0 kw/3.0 kW including rubber washer ISI marked any type complete all as specified and directed.
Taking down of water storage Gyser and refixing after repair at its own position or other location including new hlodfastner complete all as specified and directed.
S&F in repairs thermostat for water storage heater SP 230V complete all as specified & directed.
S&F in repairs non return valve 15 mm dia & connecting of complete heavy duty ISI marked complete all as specified & directed
S&F in repairs safety valve / high pressure release valve 15 mm dia ISI marked complete all as specified & directed
S&F in repairs indicator neon lamp 230 volts SP square or round complete all as specified & directed
S&F in repairs connection pipe of 45 cm long stainless steel anti slip technology,anti explosion design complete all as specified & directed
Supply and fixing in repair of LED street light fitting new generation energy saving and environment friendly long life LED 70 Watt with following specifications : 230 V AC outdoor type, top opening , IK-08, seperate driver compartment, input voltage AC 140V-300V, power factor > 0.95, beam angle 140 x 90 degree , colour temperature 6500 K , rated life 50,000 Hours , pressure die cast aluminum hosing and heat resistant with tempered PC cover with integrated lens, efficiency 145 lumen/watt ,BIS Certified to LM-79/LM-80 lamp with impact and corrosion resistant including thermal management , over-voltage,short circuit ,open circuit and surge protection in multiple optics complete with IP 66 protection including bracket of suitable size with 5 years manufacture warrenty complete all as specified and as directed by engineer-in-charge.
Supply and fixing in repair of LED building security light fitting new generation energy saving and environment friendly long life LED 35 Watt with following specifications : 230 V AC outdoor type, top opening , IK-08, seperate driver compartment, input voltage AC 140V-300V, power factor > 0.95, beam angle 140 x 90 degree , colour temperature 6500 K , rated life 50,000 Hours , pressure die cast aluminum hosing and heat resistant with tempered PC cover with integrated lens, efficiency 120 lumen/watt ,BIS Certified to LM-79/LM-80 lamp with impact and corrosion resistant including thermal management , over-voltage,short circuit ,open circuit and surge protection in multiple optics complete with IP 66 protection including bracket of suitable size with 5 years manufacture warrenty complete all as specified and as directed by engineer-in-charge.
Taking out existing unserviceable bracket Supply and fix in repairs pipe bracket made out of 25 mm/40 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall including necessary clamp/saddle and fixing by screw/bolt complete all as specified and directed.
Taking out existing unserviceable FRP terminal box and S&F mounting type weather proof terminal box of size 300 x 200 x105 mm heavy duty (hot press machine mould) consisting of 01 No MCB SP 10 Amps and backlite connector of 32 A for Three phase and neutral (Four terminals) for cable in cable out entire complete. Terminal box to be fixed to wall/ Pole all as specified and directed.
M&L for prepartion of old paint with electrically operated spray machine surfaces of LT panel/feeder piller box of any type outdoor/indoor including removing old paint with scrubing and applying two coats of synthetic emanel paint of shade as per existing over a coat of red oxide primer, complete all as specified and directed.
Supply & fixing in repairs LED phase indicating lamp R Y B colour as required at site in existing panel boards complete all as specified and directed.
Supply and Fix digital type ammeter 0-50 Amps range,flush type with appropriate CTs, AC, 50Hz in existing panel boards after disconnecting of cables and testing including removing unserviceable item complete all as specified and directed. Make :- AE / L&T / Secure / Enercon
Supply and Fix digital type voltmeter 0-500 volts range, flush type, AC, 50Hz in existing panel boards after disconnecting of cables and testing including removing of unserviceable voltmeter complete all as specified and directed. Make : AE/ Secure/ Minilec / L&T / Siemens
S & F Highly efficient LED Motion sensor Bulbs, 10 W, output of 900 lumens, cool white, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap, complete and standard warranty of manufacturer from date of purchase/ installation all as specified and directed. Make - Crompton or Equivalent in Philips, Crompton
S & F Highly efficient 12 Watt, B-22 , Back up LED Bulb cool white, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap, complete and standard warranty of manufacturer from date of purchase/ installation all as specified and directed. Make - Crompton or Equivalent in Philips, Crompton
M&L for fault finding and load balancing by measuring load in each phase, disconnecting and reconnecting the wiring in order to distribute the load in a balanced manner to existing DB complete all as specified and as directed by engineer-in-charge.
S&F LED round type light 15 Watt , 230V , 50 Hz AC , surface mounted, 6500 K , cool white, Lumen efficiency 80lm/Watt with primium grade opel diffuser and no harmful UV/ IR radiation with motion sensor complete with connecting to existing ceiling rose.
Disconnecting the incoming and out going cable connection and dismantling the unserviceable conventional type industrial meter board and removing from site for further disposal. Design fabricating supplying and fixing indoor type horizontal panel/ vertical panel Suitable for fixing of 08 nos smart prepaid meter size 160mm x 262mm x 99mm . The electric meter mounting base made of vermin, termite and weather proof totally enclosed cubical type front operated double door separate and suitable compartment for prepaid smart meter, fabricated out of 2 mm thick stainless steel sheet 304 grade sheet and with industrial type built in locking arrangement. The meter box shall be factory made from a reputed panel fabricators. The panel shall be wall/floor mounting type and to be fixed with all necessary fixing arrangements such as angle iron brackets and frame or iron angles 5 mm thick. The panel to be pre-wired with PVC insulated copper conductors for monitors and copper busbar with heat shrinkable sleeves of capacity 250 Amps for connecting the incoming MCCB and suitable size copper conductor connection between meter and copper bus bar (not less than 06 Sqmm) out going MCB (mounting on GI rail or Insulator) and including digital type multifunction meter with the following items complete all as specified (Meter panel) (a) Copper busbar 250 Amps for phases and neutral duly sleeved with heat shrinkable insulation using colour code for R Y B &N set of 4- 01 Set. (b) MCCB, TPN, 125 Amps 415 Volts 16 KA- 01 No (incomer) (c) MCB SPN, 40 A, 230 Volt, 10KA, ‘C’ curve -8 Nos (out going) (d) MCB,SP, 16 A, 230 Volt, 10KA,‘C’ curve -01 Nos (out going) (e) Indicator lamp complete with lamp holder LED type set of 03-01 set (f) VAF+ PF meter CL-0.5, input Voltage-50-520 VAC, CT 1A/5 A, Parameter VLL,VLN,A, F& PF digital type meter of size 96mm x 96mm - 01 No
Supply and fix ground earth enhancement bentonite-sodium-carbon compound to improve the earthing with properties i.e bio tech grade, anti corrosive, BFC material conforming to IS 3043, IEE:80 all as per directed by Engr-in-charge.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 1,42,920.00 (Minus) as listed in Schedule of Credit. Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'. Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple storey bldgs having height G+4 to G+16 configuration , Necessary scaffolding and safety measures required during execution of work are including in this items. Note 3:- Any T&P required at site will be arranged by contractor without any financial effect to department and rates for the same are included in respective items. Note 4 : Contractor supervisor to report on daily basis to the concerned JE E/M as detailed by the Engr-in-Charge on daily basis to collect the complaints from complaint cell/ JE E/M in morning by 9.15 am on all working days, supervise the work and again report to AGE E/M/JE E/M in evening daily by 4.45 pm to submit the progress and details. Note 5: While Quoting the tender contractor must keep in mind that the fitting and fixtures will be fixed as per day to day complaint recieved from various locations i.e NCHC Powai, NCHC Ulhasnagar and 23 A Mhada Powai and the contractor must engage the adequate labour to resolve complaints within given time frame (except Govt holidays and rainy days) after receiving of complaint without any extra cost to govt or as directed by Engineer-in-charge. And, if the contracor/ deputed supervisor fails to rectify the complaint within the stipulated time frame a penalty of Rs 50/- per complaint will be deducted from the contratcor part as per the priority i.e. Priority-I for 24 hrs, Priority- II for 72 hrs and Priority- III for 07 days of a given complaint.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
TENDERDOCUMENTS_8464.pdf
Tender Documents • 1.46 MB
BOQ_836225.xls
BOQ • 1.98 MB
Download all tender documents and submit your bid