Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.9 LAccepted-AOC GURHA BRAHMANA TEH AKHNOOR DISTT JAMMU PIN 181201 | JAMMU | JAMMU AND KASHMIR | 181201 | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹26.4 L+₹44,344.50 (1.71%)Rejected-Finance | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹32.5 L+₹6.5 L (25.2%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹32.6 L+₹6.7 L (25.7%)Rejected-Finance H NO 01 EXTN 01 SUBASH NAGAR JAMMU J K 180007 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180007 | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | Rejected-Technical H NO 2049 HANUMAN COLONY NEAR TCP 3 HISAR CANTT PIN 125006 HARYANA | HISAR | HARYANA | 125006 | - | Rejected-Technical Not enlisted in a (ii) category |
Tender Value
Refer Docs
EMD Value
₹71,000
Closing Date
14 Feb 2023, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
SPECIAL REPAIR TO BUILDING NO T-103 AT BIKANER LINE AND PROVISION OF SOAKAGE WELL AND SEPTIC TANK INCLUDING UPGRADATION OF SEWAGE LINE AT NAUSHERA LINE AT DAMANA UNDER GE JAMMU
2023_MES_576270_1
GEJC-74/2022-23
Open Tender
Civil Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹71,000
Yes
3 Apr 2023
20 Jan 2023
16 Feb 2023
20 Jan 2023
14 Feb 2023
2 Feb 2023
Amount
B/R Portion: - Dismantling asbestos cement (corrugated or semicorrugated etc) sheets in roof covering complete all as specified and as directed.
Material and labour for pre-painted galvalume aluminum zinc coating galvanised iron based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Material and labour for pre-painted galvalume aluminum zinc coating galvanised iron based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling timber scantling 40 Sq cm and over in section framed work of any description complete all as specified and as directed.
Supply and fixing for structural steel works of Fe-410 W (Grade 'E' 250) quality 'A', as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. including painted one shop coat of zinc chromate / red oxide primer paint (including preparation of surface) before fabrication complete all as specified and as directed.
Material and labour for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410 W (Grade 'E' 250) quality 'B' complete all as specified and as directed.
Material and labour for mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, not exceeding 15 cm long complete all as specified and as directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed by Engineer-in-Charge.
Dismantling boarding any description fixed in any position with nail complete all as specified and as directed.
Supply and fixing for 4mm thick of size 605 X 605 mm, white pre-premiered, self embossed, reinforced designer board for false ceiling conforming to IS-14862 and ISO-8336 : 1993 fixed / laid / incuding galvanised iron frame work at ceiling with screws frame work for ceiling with specification as under mentioned:- (i) Galvanised iron section frame work (Powder coated) suitable for ceiling board consisting of perimeter wall angle 19mm X 19mm X 0.45mm, cross 'Tee' 28.6mm (web) X 24mm flange 0.33mm thick powdered coated main tee 38mm (Web) X 24mm flange 0.33mm thick. Wall angle shall be screwed / fixed to brick wall / partition wall / concrete / RCC with the help of nylon sleeves and screws @ 610 mm centre to centre, then suspending galvanised iron main 'Tee' in both directions by means of hangers / suspenders including 4 galvanised iron wires with alignment @ 1220mm centre to centre to soffits. To from grid of 610 X 610mm cross Tee shall be provided @ 610mm centre to centre in both directions and all suitable provisions shall be made for fixing the recessed / surface mounting light fittings if any complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 Sqm each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fasts shall be finished identical to existing finish (without any extra cost to Govt) and removing from site complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm each but not exceeding 4.0 Sqm each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fasts shall be finished identical to existing finish (without any extra cost to Govt) and removing from site complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each complete and removing from site complete all as specified and directed by Engineer-in-Charge.
Material and labour factory made pressed steel frames of size 105 x 60mm made out of PBI sheet 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete including bottom of each chowkhat to be welded with 02 no's 25 x 25 x 3mm angle iron projecting 10 cm one either side including one shop coat of red oxide chrome primer and including PCC (1:3:6) type C-0 in back filling of chowkhats and tarring back of chowkhats and hold fasts complete all as specified and as directed.
Material and labour factory made pressed steel frames of size 125 x 60mm made out of PBI sheet 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete including bottom of each chowkhat to be welded with 02 no's 25 x 25 x 3mm angle iron projecting 10 cm one either side including one shop coat of red oxide chrome primer and including PCC (1:3:6) type C-0 in back filling of chowkhats and tarring back of chowkhats and hold fasts complete all as specified and as directed.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet and edges will be painted to match with printed sheet, reinforced with mild steel square tube supplying and fixing in opening as per specification complete all as specified and as directed.
Supply and fixing factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded / sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing complete all as specified and as directed.
Supply and fixing 30mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides with lipping / frame to match complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 35mm thick factory made second class hard wood, glazed and skelton shutter open rebated and prepared to receive glass, gauge, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR 2020 Part-I section 8.24 (b) supplied and fitted to chowkhats complete all as specified and as directed.
Supply and fixing mild steel butt hinges medium weight 100 mm long complete all as specified and as directed.
Supply and fixing aluminium handle cast type, anodised size 150mm long, 'D' type complete all as specified and as directed.
Supply and fixing aluminium anodised barrel tower bolts, with bright bolt and fixed 200mm complete all as specified and as directed.
Supply and fixing 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed.
Supply and fixing box type steel windows / Ventilator (factory made) outer frame made out of ERW tube 'P' section 65 X 45 X 25 mm and shutter of ERW tube 'P' section 50mm X 35mm X 20mm openable (double shutter) with glazed shutter on external side and gauzed shutter on internal side including steel pintel hinges steel handle 100 mm long mild steel tower bolt 02 no's on each shutter stopper of 'Z' section and its locking arrangement and mild steel hook and eyes suitable for fixing cooler / AC window complete all as specified and shown on drawings No CEPZTD-324/07 Sh 1/3 to 3/3. Notes: - The quoted rates shall also include: - (i) One shop coat of zinc chromate primer on all exposed surface and one coat of tar on the ends of steel surface in contact with bricks / concrete surface. (ii) 4 no's MS steel lugs made of 20 X 5 mm iron flat 200 mm long. (iii)10 mm Sq Bar grill / guard bar design as per drawing. (iv) PCC block for embedding lugs.
Supply and fixing galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
Supply and fixing mild steel helical door spring 150mm including roller and roller plate complete fixed with welding to existing / new steel chowkhats all as specified and directed.
Supply and fixing 3mm thick ordinary glass sheet quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane including punching or drilling out old glazing pins or spring clips and providing and fixing new clips or pins, including scaffolding to reach up to 4 storey building complete all as specified and as directed.
Supply and fixing floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, overall length of cover plate as 150mm complete all as specified and as directed.
Material and labour for applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description not otherwise described over 10 cm width or girth including preparation of surface complete all as specified and directed.
Material and labour for applying two coats of synthetic enamel paint on wooden surface over one coat of pink primer including preparation of new surface over 10cm width or girth complete all as specified and as directed.
Material and labour for rendering 20mm thick in cement mortar (1:4) on concrete wall surface including two or more dubbing coat including necessary formwork and scaffolding surface finished even and smooth without using extra cement such as chajjas, upward fascias and similar items up to four storey building including taking down of loose plaster / RCC / bricks surfaces complete all as specified and as directed. (including all necessary scaffolding, lifting arrangment for three storey building on external surfaces).
Taking down cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubbing down with water and removing unserviceable material outside cantt area complete all as specified and directed by Engineer-in-Charge. Note: - Rates are deemed to be included for patches work.
Material and labour for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surface finished even and smooth without using extra cement including mixing of integral water proofing compound in the proportion if required as per manufacturer's instructions complete all as specified and as directed. (Including all necessary scaffolding, lifiting arrangement).
Material and labour for rendering 15 mm thick in cement mortar (1:6) on fair faces of concrete or brick surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Material and labour for rendering 5 mm thick in cement mortar (1:3) on fair faces of concrete surface of ceiling, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparing plastered or unplastered new surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
Material and labour for applying two coats of cement based paint over a coat of primer including preparation of new plastered surface of wall complete all as specified and as directed.
Material and labour for applying two coats of oil bound distemper to newly plastered surfaces including preparation / priming the surfaces and applying wall putty complete all as specified and directed by Engineer-in-Charge.
Material and labour for applying two coats of oil bound distemper of wall to old plastered surfaces including preparation of surfaces and applying wall putty complete all as specified and directed.
Material and labour for preparing plastered or unplastered new surfaces of ceiling and applying two coats of white wash complete all as specified and as directed.
Material and labour for preparing plastered or unplastered old surfaces of walls and applying two coats of white wash complete all as specified and as directed.
Material and labour for preparation of old plastered or unplastered surfaces of walls including cornices, pillasters by brooming down or steel wire smoke, root, moulds, moss and efflorescent salts and trading oil and greasy spot by using suitable chemical and removing nails, making good holes with chalk whiting, filling cracks and brooming to remove all dirt etc and applying two coats of cement based paint on old prepared surfaces of walls all as specified and directed.
Material and labour for preparing plastered or unplastered new surfaces of walls and applying three coats of white wash complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc including PCC benching / coping etc complete all as specified and as directed.
Material and labour for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed.
Description all as per Ser Item No 45.00 here-in-before but except bricks complete all as specified and as directed.
Dismantling floors, hearth or wall tilling including cement mortar bedding (but not backing) removing unserviceable materials outside MOD area and rubbish off the premises complete all as specified and as directed.
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
Description all as per Ser Item No 48.00 here-in-before but as in skirting including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
Material and labour for granite 20mm thick (Pure black) (tabled rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in colour cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in cement mortar (1:4) edges of slab to be rounded from all sides (including cutting, wastage and polishing) complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing and making good, cutting not exceeding 10cm girth complete all as specified and as directed.
Taking up or down steel tubing with connections for cleaning for refixing or removing or storeyard complete of bore 15mm all as specified and as directed.
Taking up or down steel tubing with connections for cleaning for refixing or removing or storeyard complete of bore 20mm all as specified and as directed.
Supply and fixing steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore 15mm all as specified and as directed.
Supply and fixing steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore 20mm all as specified and as directed.
Refixing only 15mm dia steel tubing and connections in new or old position including cleaning of old steel tubing complete all as specified and as directed.
Refixing only 20mm dia steel tubing and connections in new or old position including cleaning of old steel tubing complete all as specified and as directed.
Complete removal of vegetations, roots and shrubs from wall and making good the wall surface filling with PCC (1:2:4) type B-0 all scaffolding up to 9 metre height of building complete all as specified and as directed.
Supply and fixing in repair PVC low level flushing cistern valve less, syphonic action type of 10 litres capacity white with inlet, ball valve, float and handle including cast iron brackets, PVC flush pipe 32mm dia, PVC connection (15 x 450 mm) long complete all as specified and as directed.
Supply and fixing in repair vitreous china squatting pan 'Orissa' pattern size 580 x 440mm white, with integral foot rest 'P' or 'S' trap, front or back inlet including connection to trap and to flushing pipe, anti syphonage pipe, etc. complete making good to floor as existing complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of surface of sunken slab and applying 15mm thick plaster in cement mortar (1:4) mixed with water proofing compound both on floor and wall @ 200ml per 50 Kg bag of cement and apply epoxy resin coating with modified cement coating like brush bond of Fosroc / Pidilite / Bostic as per manufacturer's instruction both on floor and wall complete all as specified and as directed.
Supply only integral liquid water proofing admixture of approved make all as specified and as directed.
Supply and fixing in repairs stainless steel sink with drainage board made of 1.00mm thick sheet for kitchen or laboratory with sink coupling, plug, washers, waste pipe including bedding in cement mortar to dwarf wall or including fixing cast iron cantilever brackets, connecting union to pipe, overall size 915mm x 460mm, bowl size (410 x 330 x 160mm) complete all as specified and as directed.
Supply and fixing in repairs kitchen plate rack of stainless steel of size 900 x 800 x 230mm made out of 1 mm thick stainless steel sheet complete all as specified and directed.
Supply and fixing in repairs Vitreous china wash hand basin white, flat back of size 550 x 400mm including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed by Engineer-in-Charge.
Supply and fixing pillar tap fancy type chromium plated with capstan head, screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipes 15 mm bore dia complete all as specified and as directed.
Supply and fixing PVC connection 15mm, 450mm long with nuts and washers complete all as specified and as directed.
Supply and fixing 15mm bore long body bib tap cast copper alloy fancy type chromium plated with capstan handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. As per sample kept in AGE B/R Damana office.
Supply and fixing PVC waste pipe 32 mm dia and suitable length straight or flexible type for wash hand basin / sink complete all as specified and as directed.
Supply and fixing in repairs chromium plated bib tap 15mm size with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
Supply and fixing angle / stop valve of cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed 15 mm bore complete all as specified and as directed.
Supply and fixing swivel shower rose PTMT any colour with arm 15mm size 195mm long complete all as specified and as directed.
Supply and fixing in repairs tubular towel rail, 20mm dia, 'D' type 60cm long between flanges of brass chromium plated complete all as specified and as directed.
Dismantling PVC water tank / demolition of RCC water storage tanks of capacity upto 1000 litres and removing from site complete all as specified and as directed.
Supply and fixing in repairs rotational moulded polyethylene water storage tank including plastic lid cover, double layered, cylindrical vertical with closed top hoisted and fixed in position of capacity 500 litres including making connections, 20 mm dia ball valves high pressure PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gram) complete all as specified in SSR Part - I and as directed.
Supply and fixing in repair curtain rod chromium plated / PVC coated, mild steel, with fixing brackets, side ball stops, rollers, etc complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removing unserviceable material outside cantt area all as specified and directed by Engineer-in-Charge.
Material and labour for plain cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in copings, benching, bed block etc. and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form works complete all as specified and as directed.
Material and labour for 50mm thick cement concrete (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in floor / plinth protection laid in suitable panels finished even and fair all as specified. 6 mm joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 grade and three parts of sand (all by weight) complete all as specified and as directed.
Supply and fixing in repairs 18 / 19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws / nails to timber / steel frame work as in shelves, cup board shutters, book case, writing table stand, shelves etc including fixing of plain fillets square or rectangular of second class hard wood not exceeding 3 Sq.cm in leaping to shutters / shelves compete fixed all as specified and as directed.
Supply and fixing continuous piano hinges, mild steel, bright finish or electrogalvanised, width of flap 30mm (when open) fixed with welding complete all as specified and as directed.
Supply and fixing hasp and staple size 100 mm, alumium anodised, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed.
Material and labour for cement concrete (1:5:10) type E-2 (using 40mm graded crushed stone aggregate) in foundations, filling and mass concrete, as in sub base for paver blocks complete all as specified and as directed.
Material and labour for 60 mm thick machine pressed precast conctete interlocking colour paver block in coloured glossy finish with any colour cement and pigment, any shape and size confirming to IS : 15658-2006, M-35 grade complete all as specified and as directed.
Material and labour for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
Supply and fixing in repair 110 mm dia bore PVC (SWR) pipes single socketed in any length with solvent cement joints, fixed to wall complete all as specified and as directed.
Supply and fixing in repair 75 mm dia bore PVC (SWR) pipes single socketed in any length with solvent cement joints, fixed to wall complete all as specified and as directed.
Supply and fixing in repairs PVC (SWR) bends of bore 110mm dia complete all as specified and as directed.
Supply and fixing in repairs PVC (SWR) bends of bore 75 mm dia complete all as specified and directed.
Material and labour for construction of septic tank for 250 users, exceeding in ordinary soil, foundation in PCC (1:2:4), brick work in cement mortar (1:4), RCC slab covers including RCC precast manhole covers having 6 mm plate embedded all round / fibre reinforced cover with angle iron frame vent shaft and sludge chamber etc complete all as specified and as directed and shown in Drawing No CEPZ/C-TD/013/13 Sh 01-05.
Material and labour for construction of septic tank for 25 users, exceeding in ordinary soil, foundation in PCC (1:2:4), brick work in cement mortar (1:4), RCC slab covers including RCC precast manhole covers having 6 mm plate embedded all round / fibre reinforced cover with angle iron frame vent shaft and sludge chamber etc complete all as specified and as directed and shown in Drawing No CEPZ/C-TD/013/13 Sh 01-05.
Material and labour for soakage wells exceeding in ordinary soil, foundation in PCC (1:3:6), wells of honey combed and solid in M-25 concrete, including intercepting chamber, screen chamber brick work in cement mortar, RCC cover slab in M-25 / RR masonry / filling with brick bats, complete of size 2.4 m dia X 3.0 m deep complete all as specified and as directed and shown in Drawing No CEPZ/C-TD/013/13 Sh 01-05.
Material and labour for soakage wells exceeding in ordinary soil, foundation in PCC (1:3:6), wells of honey combed and solid in M-25 concrete, including intercepting chamber, screen chamber brick work in cement mortar, RCC cover slab in M-25 / RR masonry / filling with brick bats, complete of size 1.8 m dia X 3.0 m deep complete all as specified and as directed and shown in Drawing No CEPZ/C-TD/013/13 Sh 01-05.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc and not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in any type of soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
Demolition by breaking up drain pipes (salt glazed stoneware or AC / RCC) 150mm dia jointed in cement mortar and taking out of trenches and removing the debris including concrete bed and haunching from the trenches complete all as specified and as directed.
Material and labour for 200mm bore / inner dia double wall corrugated HDPE pipes (SN-4) with integral socket and necessary fittings, laid in trenches jointed as per manufacturer's instructions complete all as specified and as directed at site.
Demolition by breaking up drain pipes (salt glazed stoneware or AC / RCC) 100mm dia jointed in cement mortar and taking out of trenches and removing the debris including concrete bed and haunching from the trenches complete all as specified and as directed.
Material and labour for 150mm bore / inner dia double wall corrugated HDPE pipes (SN-4) with integral socket and necessary fittings, laid in trenches jointed as per manufacturer's instructions complete all as specified and as directed at site.
Material and labour for 300 mm bore reinforced concrete pipes, class NP-2, laid and jointed complete with collars complete all as specified and as directed.
Material and labour for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) for 300mm bore pipe complete all as specified and as directed.
Material and labour for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:4) complete all as specified and as directed.
Description all as per Ser Item No 105.00 here-in-before but except bricks complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
Material and labour for precast RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in manhole cover slab fixed in position including necessary form work and set in cement mortar (1:6) complete all as specified and as directed.
Material and labour for mild steel TMT 10mm dia and over cut to length, bent to shape, required including cranking, bending, spirally for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Material and labour for TMT bars 6 to 8mm dia cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
Cutting into existing manholes for connecting new drain 150mm dia making good to pipe and rendering cutting out existing for and forming branch channel (½ round or ¾ round section) in cement concrete (1:2:4) type B-1 smooth finished and reforming benching as required complete all as specified and as directed.
Cutting into existing manholes for connecting new drain 200mm dia making good to pipe and rendering cutting out existing for and forming branch channel (½ round or ¾ round section) in cement concrete (1:2:4) type B-1 smooth finished and reforming benching as required complete all as specified and as directed.
NOTE NO 1: - Samples of materials as approved will be kept in GE's sample room. NOTE NO 2: - All fittings and fixtures mentioned above will be fixed to the satisfaction of Engineer-in-Charge and GE. NOTE NO 3: - Warranty certificate to the Engineer-in-Charge where ever applicable shall be submitted by the Contractor at the time of fittings.
E/M Portion: - Taking down old unserviceable copper / aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden / iron, round block etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into new concealed PVC rigid / steel conduit and into existing cast iron / pressed steel sunken / terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Notes: - (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description all as per Ser Item No 115.00 here-in-before but for one 5 pin socket outlet 5 amps on the same board complete all as specified and as directed.
Description all as per Ser Item No 115.00 here-in-before but for one 5 pin socket outlet, 5 amps, independent complete all as specified and as directed.
Description all as per Ser Item No 115.00 here-in-before but for one 5 pin socket outlet, 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Supply and fixing in replacement for switch piano, flush type, single pole one way 5 Amp, 240 volts complete all as specified and as directed.
Supply and fixing in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and as directed.
Supply and fixing in replacement switch socket outlet combined 5 pin, 5 amp flush type, 240 volts complete all as specified and as directed.
Supply and fixing in replacement switch socket outlet combined 2 in 1, 3 pin, 5 amp and 15 amp flush type, 240 volts complete all as specified and as directed.
Material and labour in replacement for lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Material and labour in replacement self ballast LED retrofit lamp with PVC body and PC diffuser 9 watt 230 Volt 6500K complete all as specified and as directed.
Supply and fixing ceiling rose 3 terminal surface type complete all as specified and as directed.
Supply and fixing in replacement LED lights fitting 1 x 20 W, 220 V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor > 0.95, 100 Lumen / Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4' ft long) with LED rod 20 watt, 230 Volts 50 Hz complete all as specified and as directed.
Material and labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in replacement 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing SPN 40 to 63 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 30 watt system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, TIP - 66 protection suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor>0.95, working temperature range - 20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour for earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground earth (in vertical) earth pit not less than 2.25 metre deep below normal ground level with top edge of the earth plate not less than 1.5 metre below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and as directed.
Supply and fixing in replacement plug top 15 Amps complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
Disconnecting and taking out defective service cable any size and any type from roof, pole, pipe, floor, wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 Sqmm 2.0 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed. Note: - (i) Earth work, sand, bricks, removing, returning filling, Aluminium thimbles / lugs will be paid separately. (ii) Cost of laying electrical cable through new / existing pipe under road, buildings, railway tracks, highways are included in the quoted rates. (iii) All equipments, machinery or tools if required for laying electrical cable through new / existing pipes are provided by the contractor without any extra cost.
Supply and laying, connecting and testing TPN 4 Pole, MCCB with SS enclosure 63 Amps, 50 Hz including fixing on wall with proper nuts and bolts complete all as specified and as directed.
KRISHNA BUILDERS
M/s Koul & Sons
Mehta Enterprises
Bidder Name
KRISHNA BUILDERS
M/s Koul & Sons
bushan kumar
Mehta Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .