Estates Officer
Estates Division SKUAST Jammu Main Campus Chatha
Construction of pasteurization unit for preparation of pasteurized compost through short method of composting including pasteurization tunnel and bunkers for Division of Plant Pathology at Chatha
2023_SKUST_234700_6
AU/Estates/23-24/13 dated 20-10-2023
Open Tender
Civil Works
Item Rate
360 days
Main Campus Chatha
Please refer tender documents
4 documents required · 4 mandatory
₹1,500
Assistant Comptroller Estates SKUAST Jammu
₹1.3 L
Yes
13 Dec 2023
27 Oct 2023
23 Nov 2023
27 Oct 2023
22 Nov 2023
27 Oct 2023
Amount
Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 Sq. m on plan), including dressing of sides & remaining of bottoms , lift upto 1.5 m , including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 m
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level :
1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth and curing complete.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, walls, bases of columns, etc. for mass concrete.
Edges of slabs and breaks in floors and walls.
Under 20 cm wide
Columns, Pillars, Piers, Abutments, Posts and Struts.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floors, roofs, landings, balconies and access platform.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.
Cold twisted/TMT bars
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1: 6 (1 cement: 6 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium handles ISI marked (powder coated) with necessary screws etc. complete :
Providing and laying Vitrified floor tiles (Size 600 x 600 mm), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades laid over 20 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete
Size 600 x 600 mm
Providing gola 75x75mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3(1 cement : 3 fine sand) as per standard design
In 75x75mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
12 mm cement plaster of mix : Inside plaster
1:6 (1 cement: 6 fine sand)
18mm Cement plaster in two coats under layer 12mm thick cement plaster 1 : 5 (1 cement : 5 coarse sand) finished with a top layer 6mm thick cement plaster 1 : 6 (1 cement : 6 fine sand) (Outside plaster)
6 mm cement plaster of mix :
1:3 (1 cement: 3 fine sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
New work (two or more coats) over and including water thinnable priming coat with cement primer.
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work.
Providing and laying RBM (River Bed Material) including loading, carrying, unloading, spreading, compacting and watering complete item.
Providing and fixing following PVC pipes alongwith necessary assesories and fitting (such as tee, elbow, bends etc )complete items
PVC pipe (150 mm nominal dia)
PVC pipe (200 mm nominal dia)
PVC Pipe (15 mm nominal dia)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing ACP in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5.00 mm thickness
Providing and fixing wire gauge in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment)
Providing and fixing aluminium eye hooks for aluminium shutters.
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors ,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side ofhe sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required
Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Ridges plain (500 - 600mm)
Providing and fixing 25 mm thick thermocoal along with chicken mesh complete item
Carriage of material from source to site
Sand (10 kms)
Aggregate (10 kms)
Bricks (18 kms)
SUB-DISTRIBUTION BOARDS
Providing and fixing 6 amps to 32 amps rating 240 volts, 'L' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqired (category B)
Single Pole
Triple Pole and neutral
Triple Pole
Supply and fixing of following rating, 2P 230 volts, SPN in the existing MCB DB complete with connections, testing and commissiong etc. as required
40 amps SPN
63 amps SPN
EARTHING AND LIGHTNING PROTECTION
Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) complete as required for earthing and lightning protection.
Providing and fixing 25 mm x 5mm GI strip from earth electrode as required
Supply, installation, testing at works, installation and commissioning of following distribution boards totally enclosed compartmentalized, cubicle indoor type fabricated with 16 SWG sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/ mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply as per specifications and drawings.
Moulded case circuit Breakers shall be thermal magnetic trip type. Fault level for all MCCB and bus bar shall be 35 KA. ICU shall be equal to ICS=100%
All metering current transformers shall be Class 1, 15 VA.
MDB-1 (Indoor Type)
Incomer
125 A 4P MCCB – 1No.
R,Y,B phase indicating lights with control fuses - 1 set
Bus Bar
125 A 415V, 50Hz, 3ph, 4 wire Aluminium Bus bar
Outgoing
40 Amp TPN - 1 No.
63 Amp TPN - 1 No.
40 Amp SPN - 2 No.
63 Amp SPN - 2 No.
Supply and fixing of the following way, single pole and neutral / three pole and neutral, sheet steel, double door, phase segregation type, MCB distribution board, 230V / 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar and link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing, etc., as required.
8 way TPN
12 way SPN
Supply and fixing 1x20 watt box type fitting complete with extruded alulminium tube rod including connection testing etc. as reqd. (CAT No. DMLNLT8-16 and LTT8-20)
Supply and fixing of 18 Watt LED Panel surface mounted including connection testing etc as reqd. (CAT No. LCDSPLN-R-18-CDL)
Supply and fixing of 12 Watt LED Panel surface mounted including connection testing etc as reqd.
Supply and fixing of 70 Watt LED street light with GI pipe bracket with all accessories including connection testing.
Wiring for light / fan / exhaust fan / call bell point with 1.5 Sq mm FR PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit(2mm thick) with modular switch and plate, GI box and earthing the points with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc.
Supplying and fixing suitable size GI box with modular plate and covered in front on surface or in recess, including providing and fixing 6 pin 5/6 Amp modular socket outlet and 5/6 Amp modular switch with connections, etc. as required. (Power plug)
Wiring for light plug with 2 x 2.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x 2.5 mm copper wire for loop earthing required
Wiring for power plug with 2 x 4 sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x4.0 Sq mm copper wire for loop earthing as required
Wiring for power plug with 2 x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x1.5 Sq mm copper wire for loop earthing as required
Wiring for 1x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked in the existing PVC conduit etc. as required ( Invertor wiring )
Wiring for sub main wiring with following sizes of PVC/ insulated copper conductor wires in the surface/ recessed PVC / MS conduit along with PVC insulated copper conductor earth wire as required complete with connections, testing and commissioning etc. as per specifications and drawings.
2x6 sq mm with 1x6.0sqmm earth wire
2x10sq. mm with 1 x 6.0sq. mm earth wire
4x 4 sq. mm with 1 x 6.0sq. mm earth wire
Wiring for sub main wiring with4x10 sqmm alongwith 2x6sqmm earth wire sizes of PVC/ insulated copper conductor side core conductor in surface/recessed PVC conduit etc. as reqd.
Supplying and fixing suitable size GI box with modular plate and covered in front on surface or in recess, including providing and fixing 6 pin 5/6 and 15/16 Amp modular socket outlet and 15/16 Amp modular switch with connections, etc. as required. (Power plug)
Supply and fixing of 250 mm x 300 mm x 100 mm deep size metal box with suitable size phenolic laminated sheet cover in the front including connection testing etc as reqd.
Supply and fixing of 200 mm x 300 mm x 100 mm deep size metal box with suitable size phenolic laminated sheet cover in the front including connection testing etc as reqd.
Supply and fixing step up electronic fan regulator on the existing switch box including connecting testing etc. as required.
Supply and fixing 20 Amp Industrial socket with 32 Amp SPN including connection, testing, etc. as required
Supply and fixing of 25 mm dia PVC conduit alongwith accessories in surface/recess.
Blower for compost bulk chamber 1 and 2 made of 4 mm thick M.S. sheet constructed body with dynamic impellers EN8 shaft, V belt drive transmission with safety guard and 7.5 HP motor of Crompton or Kirlosker make, 1440 RPM motor blower Air displacement capacity of 4500 cum Air/hour pressure at entry point 80 to 100 mm water point.
Ducting of G.I. sheet 63 mm thick in pasteurization tunnel with louvers, dampers etc, including digital panel box, auto timer, one sensor of ISI mark.
Remote thermometers with 6-sensors of ISI mark and digital panel of either L&T temperature reading in bulk chamber during pasteurization and conditioning of compost including ducting of G.I. sheet 1 mm thick
Dewatering pump with hose (2 HP) of Crompton or Kirlosker make for guddy pit with complete pipe fitting.
Main LT panel power load 100 HP including LT cable 50 sqmm and 2.5 mm with 100 ampere changeover including fixing cable wire with panel to all blower and equipments.
Installation charges of blower with MS channel frame, PCC including civil work, fixing of electrical panel dewatering motor fixing and main LT panel. Labour charges
Sub-station creation with complete job with 63 KVA transformer
Earthing work of main panel and blower
zakir hussain
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .