OFFICE OF THE EXECUTIVE ENGINEER (SDW) VIII
OFFICE OF THE EXECUTIVE ENGINEER (SDW) VIII
Renovation of internal and external wiring and electrical fittings at Sector-24 SPS Dwarka
2021_DJB_201052_14
NIT No.10 / EE(SDW)-VIII/ 2020-21
Open Tender
Miscellaneous Works
Works
30 days
OFFICE OF THE EXECUTIVE ENGINEER (SDW) VIII
as per nit condition
2 documents required · 2 mandatory
₹500
services.sabpaisa.in
Exempted
18 Mar 2021
6 Mar 2021
15 Mar 2021
6 Mar 2021
15 Mar 2021
6 Mar 2021
Supply of 30 Watt LED luminaries. Make :-Bajaj/Havells/DJB approved makes
Supply of 60s Watt LED luminaries. Make :-Bajaj/Havells/DJB approved makes
Supply of 18-20 Watt LED tube. Make :-Bajaj/Havells/DJB approved makes
Supply of ceiling fan. Make :-Bajaj/Havells/DJB approved makes
Supply of exhaust fan. Make :-Bajaj/Havells/DJB approved makes
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc of Single pole and neutral.
Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Rewiring for light point/ fan point/ exhaust fan point/ call bell pointwith 1.5 sq.mm FR PVC insulated copper conductor single core cable and1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Wiring of circuit sub main wiring along with earth wire with the following size of PVC insulatd copper conductor single core cable in surface recessed PVC conduit :-2x1.5 sq mm + 1 x 1.5sq. mm
Wiring of circuit sub main wiring along with earth wire with the following size of PVC insulatd copper conductor single core cable in surface recessed PVC conduit :- 2x2.5 sq mm + 1x2.5 mm
Wiring of circuit sub main wiring along with earth wire with the following size of PVC insulatd copper conductor single core cable in surface recessed PVC conduit :- 2 x 4.0 sq mm + 1x4.0 sq mm
Wiring of circuit sub main wiring along with earth wire with the following size of PVC insulatd copper conductor single core cable in surface recessed PVC conduit :- 2x10.0 sq mm + 1x6.0 sq mm
R.S. ENTERPRISES
HARI ELECTRICAL CO.
DEV ENGINEERS
SHREE BALAJI ENGINEERS
ztp corporation
Mehar Enterprises
GOGIA BROTHERS
PARTH SHARMA
Premier Engineering Company
HYDROCON ENGINEERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .