Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹1.9 L
EMD Value
₹3,791
Closing Date
5 Feb 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Nodal Officer (Tender)
O/o Sr. Chief Engineer(Civil) BSNL MP Civil Zone Block-C, BDA Flats, First Floor, Vidya Nagar, Behind Petrol Pump Hoshangabad Road , Bhopal (M.P.)- 462026
Repair maintenance work major cracks damaged terrace etc ic painting CSC only near HPO Itarsi 2nd call
2025_BSNL_224949_1
NIT NO. 17/EE(C) /BSNL-BPL/2024-25
Open Tender
Civil Works
Item Rate
60 days
itarsi
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AO Cash Oo GMTD BSNL Itarsi
₹3,791
25 Feb 2025
27 Jan 2025
7 Feb 2025
27 Jan 2025
5 Feb 2025
27 Jan 2025
Amount
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (a) 1:3:6 (1 Cement : 3 coarse sand(zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources).
Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in: (a)Cement Mortar 1:6 (1 cement : 6 coarse sand).
Brick work with common burnt clay modular bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : a) 300x16 mm
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : a)300x10 mm
Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : a) 125 mm
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Welding by gas or electric plant including transportation of plant at site etc. complete.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (a) 40 mm thick with 20 mm nominal size stone aggregate
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as perish : 4457, complete as per the direction of Engineer-in- Charge. a) In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand). (i) Acid and alkali resistant tile.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design a)In 75x75 mm deep chase
12 mm cement plaster of mix :(a)1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix :(a)1:3 (1 cement: 3 fine sand)
Neat cement punning
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. a)Two or more coats on new work.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : a) Water thinnable cement primer.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : (a)Two or more coats on new work.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. a)With cement mortar 1:4 (1 cement : 4 fine sand).
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : (a) 3 mm thick (a) 3 mm thick
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. a)Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. a) In cement mortar
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: a)Of area beyond 3 sq. metres a)Of area beyond 3 sq. metres
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.(a)For thickness of tiles 10 mm to 25 mm
Providing & Grouting of dowel tubes / Shear keys / Joints of precast members with M-60 grade cementitious grout (Non Shrink) of approved make by suitable means ( Free flowing /pump),curing etc. Complete as per directions of Engineer-in-charge. (The payment shall be made on the basis of actual weight of approved grout injected.) a)Stirrer mixed cementitious grout (non shrink) of approved make in dowel tubes / Shear keys / Joints of precast members.
Extra for providing and mixing liquid integral water proofing material conforming to IS :2645 of the approved brand such as LATEX POWER/SUPER LATEX or equivalent at the rate of 300 ml./50Kg bag of cement or in proportion as recommended by the manufacturer in cement slurry, mortar, concrete as required and as directed by the Engineer in - charge. (Note: Integral liquid water proofing material shall be added in the water needed for preparation of cement slurry, mortar, concrete as required. )
Scraping of moss,blisters etc.thoroughly from exterior surface of walls,roof etc necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge)
Labour for taking out rolling shutter (only shutter portion) dismantling by parts for repair or (replacement of damaged parts only), rehanging and refitting the same in position after necessary repairs (excluding the cost of supply of new parts)
Renewing seam pipe for rolling shutter as per existing size and shape fitting, fixing complete
Oiling and greasing of rolling shutter and repair to in side lock. Oiling and greasing of rolling shutter and repair to in side lock.
Renewing profile of rolling shutter including fitting fixing complete as per existing size and shape
Renewing spring of rolling shutter as per existing size and shape including fitting fixing complete
Reparing collapsible gate by cutting out all rivets as necessary re-assambling all members including welding pieces of channels,sraightening bent bars and rivetting with new rivets and fitting in position and painting two coats
Easing and oiling, cleaning collapsible gate and repairing to locking arrangements
Credit value of unserviceable materials :(a)All type of scraped steel/iron item e.g. reinfocement bar, structural members,doo bolts,tower bolt,handle etc
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .