Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NOT FOUND | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹11.5 L
EMD Value
₹23,000
Closing Date
4 Sept 2024, 5:00 pmClosed
GSM(Contract), Contract Complex, DPS, Kishtwar
GSM (Contract), Contract Complex, Dulhasti Power Station, Kishtwar(J and K) PIN-182206
Renovation of electrical work of Bursar Guest House in DSB Colony of Dulhasti Power Station at DPS, Kishtwar
2024_NHPC_821139_1
NH/DPS/CONT/NIT-210/2024/ E121660 dated 14.08.2024
Open Tender
Electrical Works
Works
150 days
DPS
Please refer tender document
2 documents required · 2 mandatory
₹590
NHPC Limited
₹23,000
Yes
20 Dec 2024
14 Aug 2024
9 Sept 2024
14 Aug 2024
4 Sept 2024
14 Aug 2024
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC Conduit with modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single coer cable etc. as required.
Group-C
Wiring for twin control light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC Conduit with 2 way modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single coer cable etc. as required.
Wiring for light power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC Conduit alongwith 1No.4sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light power plug with 4x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC Conduit alongwith 2No.4sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/submain alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit as required.
2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire
2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire
Supply and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.
Supply and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.surface/recessed including cutting the wall and making good the same in case of recessed conduit as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supply and fixing following moduler switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
TV antenna socket outlet
Bell push
Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate etc. as required.
Supply and fixing 3 pin, 5A ceiling rose on the existing junction box/wooden block including connections etc. as required.
Supply and fixing brass batten/angle holder including connection etc. as required.
Supply and fixing call bell/buzzer suitable for single phase, 230V, complete as required.
Installationof exhaust fan in the existing opening, including making good the damage, connection, testing. Commissioning etc. as required.
Up to 450mm sweep
Installation, Testing, Commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on celling/wall including connections with 1.5 sqmm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
4x16 Sq.mm +2x6Sq.mm earth wire
Supply and fixing 5 A to 32 A rating, 240/415V, 10KA, "C" curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Sigle pole
Supply and fixing following rating four pole, 415, Isolator in existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing following rating, four pole, (three phase and neutral) 415 volts, residual current circuit breaker (RCCB) ,having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing following way surface/recess mounting vertical type, 415V,TPN MCB distribution board of sheet steel, duct protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required.
12 way (4+36), Double door
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying of Exhaust fan,200mm sweep complete with all accessories including connections etc.as required.
Supplying of Exhaust fan,300mm sweep complete with all accessories including connections etc.as required.
Supplying of fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube/lamp including connections etc.as required.
JP Infratech
Tanveer Ahmed
Rayaz Ahmed Malik
GANAI CONSTRUCTION AND SERVICES PRIVATE LIMTED
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .