| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.8 L+₹1.1 L (3.24%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹44.0 L+₹9.4 L (27.0%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not recommended bidder not enlisted in the Cat b(i) | |
| 5 | Rejected-Technical | - | Rejected-Technical Not recomended NO remark in WLR of CEWC Qtr ending mar 2024 |
Tender Value
₹37.9 L
EMD Value
₹75,700
Closing Date
8 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Pathankot
GE (AF) Pathankot
PROVN OF 02X100 KVA VOLTAGE STABILISERS ALONG WITH ASSOCIATED WORKS AT 41 WEU (B) BAKROTA T AF STATION DALHOUSIE UNDER GE (AF) PATHANKOT
2024_MES_659065_1
GE/PAF-08/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Pathankot
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Pathankot
₹75,700
Yes
15 Oct 2024
11 Jun 2024
15 Jul 2024
11 Jun 2024
8 Jul 2024
25 Jun 2024
Amount
Rough excavation not exceeding 1.5m deep and getting out hard dense soil complete all as specified and directed by Engr-in-charge.
Removal of excavated and demolished material to a distance n exc. 50 m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed by Engr-in-charge.
Material and Labour PCC Type D-2 (1:4:8) in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Material and Labour for PCC 1:3:6 Type C1(using 20 mm graded aggregate) as in wall or retaining wall, any thickness, size or shape including pilasters buttresses columns, pillars boundary pillars andposts (including caps and bases) complete all as spefcified and as directed by the Engineer-in-Charge.
Material and Labour for formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses etc, verical or to batter, work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engneer-in-Charge
Supply and Fixing PVC (SWR) pipes single socketed, in any length of 110mm bore with rubber ring joints, laid in wall & trenches , complete all as specified and directed by Engr-in-charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removal of excavated and demolished material to a distance exc. 1.50 km but n exc. 5km and depositing complete all as specified and directed by Engineer-in-Charge.
Excavation over area n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, and getting out in hard/dense soil complete all as specified and directed by Engr-in-charge.
Excavation over area exc 1.5 m in depth and n exc 3.0 m ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, and getting out in hard/dense soil complete all as specified and as directed by engineer in charge
Material and Labour for RCC M-25 design mix as in foundation, including raft, footing foundation beams plinth beams, bases for columns complete all as specified and as directed by engineer in charge
Material and Labour for RCC M-25 design mix as in chajja complete all as specified and as directed by engineer in charge
Material and Labour for RCC M-25 design mix as in beams, cantilivers etc.complete all as specified and as directed by engineer in charge
Material and Labour for RCC M-25 design mix as in columns , pillars, piers, posts and struts etccomplete all as specified and as directed by engineer in charge
Material and Labour for Form work to sides of concrete foundation footing base of columns and raft beams sides and soffits (if any) of plinth beams complete all as specified and directed by Engr-in-charge.
Material and Labour for Form work to sides of pillars, posts, struts, pier, columns square, rectangular or polygonal rough finished surface of concrete complete all as specified and directed by Engr-in-charge.
Material and Labour for Form work to sides of floor or roof beam,lintels overhangs, etc complete all as specified and directed by Engr-in-charge.
Material and Labour TMT bars 6 to 8 mm dia cut to length, bent to shape, required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
Material and Labour TMT bars 10 mm dia and over cut to length, bent to shape, required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) with old size bricks complete all as specified and as directed by engineer in charge.
Supply and Fixing Steel windows with side hung shutters including projecting type hinges with steel handle , amd steel peg stay , complete with glazing bars, dovetailed or welded etc
Supply and Fixing 0.63mm thick galvanised, corrugated mild steel sheeting with two corrrugations side lap, fixed with coach screws and washers, in roofs, wall etc. with grade of zinc coating 275 complete all as specified and directed by Engr-in-charge.
Supply and Fixing Fe 410-w(Gde E 250)quality B rolled mild steel in roof trusses (framed) trussed, purlins, crane gantries, rails and framing (beam, tee, angle, channel or flat sections) including distance pieaces cleats etc complete all as specified and as directed by engineer in charge.
Providing & fixing false ceiling with semi perforated 12mm thick at all heights with GRS (Glass Fiber Reinforced Gypsum) false ceiling tile of size 595X595 mm of approved texture ,design and pattern having moisture content less then 2 %, humidity resistance of 99%,NRCO .50 to 0.75 as per IS 8225 :1987, Noncmbustiible as per IS 476 (part 4)-1970 and light reflectance of 855 (minimum) to be laid in true horizontal level suspended on interlocking metel T grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @120 gms per sqm including both side) comprising of main T runners of size 15X32 mm length 3000mm ,cross T of size 15X32 mm of length 600mm to from grid module of size 600mm X600mm suspended from Ceiling using galvanised mild steel items (galvanizing @ 80 gms per sqm) i e 50mm long ,8mm outer dia M-6 hanger rod upto 1000mm length and L shape level adjuster of size 85X25X2mm galvanised iron perimeter wall angle of size 24X24X0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plug at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications ,drawing and as per direction of the Engr- in Charge.
Supply and Fixing Steel rolling shutters, without ball bearing As specified ,including top cover , anchoring rod ,hasp and staple and one shop coat of primer , erected in position as indicated complete all as specified and directed by engineer in charge .
Supply and Fixing 3 mm thick sheet glass ordinary quality and glazing with beads in squares n exe o.5 sqm each pane all as specified by Engr-in-charge.
Supply and Fixing in repair galvanised mild steel wire cloth nominal dia of wire 0.56mm and average width of aperture 1.00mm in wooden/steel frame complete all as specified and directed by Engr-in-charge.
Material and Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and Labour for preparation of new plastered surfaces and applying two coats of exterior acrylic paint of any shade in comouflaged pattern as approved by GE as per manufacturers instruction complete all as specified and directed by engineer in charge.
Material and Labour for Preparation new surfaces of wall and applying two coats of oil emulsion distemper over a coat of 3 mm thick wall putty complete all as specified and directed by Engr-in-charge.
Material and Labour for preparation of new steel and iron surfaces of any description over 10 Cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer over a coat of moderant solution to remove zinc coating complete all as specified and directed by Engineer-in-Charge
Material and Labour for 100 mm thick hardcore of gauge n exc 63 mm ,deposited ,spread and levelled in layers n exc 15 cm thick , watered and rammerd to a true surface complete all as specified and directed by Engineer-in-Charge.
Material and Labour for 75 mm thick cement concrete type D-2 (1:4:8) over hardcore complete all as specified and directed by Engineer-in-Charge.
Material and Labour for 25 mm thick cement concrete type B-1 1:2:4 (20mm graded aggregate) complete all as specified and directed by Engineer-in-Charge.
Material and Labour Machine cut kota stone slab flooring 20-25mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-charge.
Material and Labour Machine cut kota stone slabs flooring 20-25mm thick, as in riser of steps, skirting, dado and piller laid and the including screed bed over cement slurry screed 10mm thick in CM (1:3) incl rubbing and polishing, rounding or bullnosing the exposed edges complete all as specified and directed by Engr-in-charge.
Material and Labour PCC 1:3:6, type C-2, 75mm thick as in plinth protection, Surface finished fair and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 20 cm deep and getting out in hard/ dense soil complete all as specified and directed by Engr-in-charge.
Material and Labour 100 mm thick Cement concrete type C1,1:3:6 (20mm graded aggregate) as in sub base finished even and rough, complete as as specified and directed by Engineer-in-Charge
Providing and laying 60mm thick factory made chemfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footpath, parks, lowns, driver ways or light trafic parking etc.of required strength; thickness & size/shape, made by table vibratory method using PU mould,laid in required colour and petern over and including 50mm thick compected bed of fine sand ,compecting and proper embeding /laying of inter locking paver block into the sand bedding layer through vibratoey compection by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern,finishing and sweeping extra sand complete all as per specified and directed by Engr-in charge
PCC (1:2:4) type B-1, 20mm graded stone aggregate in kerb stone,rounded or chemfered on edges complete all as specified and directed by Engr-in-charge.
Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exc 50 m and making good surface, work in soft disintergreted rock complete all as specified and directed by Engr-in-charge.
Supply and Fixing Fe 410-w(Gde E 250)quality B MS plates plain or chequered square cut or notched forming holes drilled or welded any thickness complete and all as specified and as directed by Engr-in-charge.
Supply and Fixing copper strip 20x3mm complete with saddles/ insulators made out of PVC or fibre and fixing screws for roof conductor/down conductor including welding or brazing for joints all as required at site or as directed by Engr-In-Charge.
Material and Labour for air termination single pointed copper rod 12mm dia and 300mm long complete and all as specified and as directed by Engr-in-charge.
Material and Labour for test point terminal block made of gun metal or phosphorus bronze of size 75X75X6mm drilled and screwed including 03 Nos 8mm dia 25mm long hexagonal head screw complete all as specified and directed by Engr-in-charge.
Material and Labour for earthing complete with copper earth plate electrode 600x600x3.15 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to copper strip 20X3 mm as earth lead by means of bolts, nuts washers and check nuts of steel/GI duly protected with 40 mm bore light grade pipe upto main board , 20mm bore watering pipe light grade with CI/MS funnel and wire mesh including excavation , earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, add charcoal dust and common salt as directred by the Engr-in-charge all as shown in electrical plate No. 03 of SSR part-I 2009 having pit in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for CI cover of required size, funnel with wire mesh complete and all as specified and as directed by Engr-in-charge.
Supply and Fixing GI tubing light grade 25mm dia, cut to size and bent to shape all as required at site including fixing arrangement with necessary clamps of required size at site and providing appropriate size of insulators to pipe from foundation of air termination rod complete all as specified and directed by Engr-in-charge.
Supply, laying, connecting and testing XLPE insulated armoured heavy duty electric cable of size 95 sqmm 3.5 core with multistranded aluminium conductor, 1100 volts grade laid in trenches/ducts/wall or through pipe or pole with suitable size of cable glands, crimping type cable lugs complete all as specified and directed by Engr-in-charge.
All as per ser item No. 51 here in before but of size 70 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
All as per ser item No. 51 here in before but of size 35 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Supply and fixing servo controlled Voltage stablizer of capacity 100 KVA (1W+1S) for automatic opeartion (Confirming as per BIS:9815:Parrt1 : 1994 reaffirmed 2009) 3 Phase, 50 Hz, naturally oil cooled indoor type, copper wound, digital Display, relay free smooth & silent operation with initial filling of Transformer Oil (IS335:1993 reaffirmed 2005) having following specification:- (i) Designed for input variation between 360 V to 480 V. (ii) Output voltage stablizer at any designed/desired voltage 415 Volts with accuracy ± 1% (Adjustable). (iii) Rated frequency 50 Hz. (iv) NO distortion in wave form. (v) Response time not to exceed 10 milli seconds. (vi) Senitivity (±) 1% (vii) Rate correction 8 Volt/second for single phase and 20 Volts/second for phase to phase. (viii) No load losses less than 0.5%. (ix) Full load losses less than 2.5%. (x) Duty cycle - continuous 24 x 7. (xi) Effieciency more than 95%. (xii) Type of load: 3 phase, unbalance type. (xiii) Digital display Voltmeter/Ampmeter. (xiv) Capacity: 100 KVA. (xv) Protections (a) Over load/Short circuit protections. (b) High/low voltage cut off. (c) Bypass arrangement in case of emergency. (d) Single phase sequence change protection. (e) Ingress protection(IP) up to IP42/45
Supply, laying, connecting and testing XLPE insulated armoured heavy duty electric cable of size 25 sqmm 4 core with multistranded aluminium conductor, 1100 volts grade laid in trenches/ducts/wall or through pipe or pole with suitable size of cable glands, crimping type cable lugs complete all as specified and directed by Engr-in-charge.
Supply,Fabrication, installation and testing of Feeder Pillar KIOSK type floor mounted dust/vermin proof indoor type of size 1.2x1.5x0.6 mtr mtr factory fabricated made out of MS sheet of thickness 3.15 mm mounted on angle iron legs made out of angle iron of size 40x40x6 mm with front & rear opening with locking arrangement, containing bus bar chamber to accommodate 3 phase & 1 neutral copper busbar of size 40x10 mm fixed on epoxy based insulators in horizontal position in upper part of panel separate chambers for 01 No. incomming MCCB and 03 Nos. outgoing MCCB connected to busbar by copper strip of size 20x5 mm duly drilled hole for cable connectioin and powder coated all as required at site or as directed by Engr-in-charge (including the PCC foudation of panel) complete including of following :- (a) MCCB 200 Amp FP 35KA (thermal, adjustable type, O/L & S/C Protection) - 01 No (I/C). (b) MCCB 100 Amp 3P 25 KA -04 Nos (c) Digital Multi-function meter with CT's of required cap – 01 No. (d) LED type Indicator lamps (R, Y. B) – 01 Set. (e) On load Change over switch unit four pole 200 Amps - 01 No. All accessories pre wired with suitable size copper conductor cable including making necessary arrangements for fixing all as required at site or directed. NOTE : 1) All connections to be done with proper size copper / Brass Thimbels. ( 2) Control circuit wiring to be done with S/C copper wire complete all as specified and directed by Engr-in-charge.
Material and labour Steel tubular swaged pole complete with cast iron plate, finial taper plug, bolts, nuts & screws as specified of type 410 SP-31, 9 meter long including applying two coats of black bituminous paint throughout internally and externally up to the planting depth and remaining portion of the exterior painted with one coat of red oxide primer over two coats of aluminium paint complete all as specified and directed by Engr-in-charge.
Material and labour for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B1, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Part-I, 2009 specification complete all as specified and directed by Engr-in-charge.
Supply & fixing cable FRP junction box with 3 No SP terminals, with IP 66 protection made of DK thermoplastic, weather proof, shock proof, halogen free for hazardous areas with internally embedded gasket and metric knock outs for cable entry suitable for cable of size up to 50 sqmm complete all as specified and directed by Engr-in-charge.
Supply and fixing time switches astro type (having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with contactor fitted inside sheet steel enclosure complete all as specified and directed by Engr-in-charge.
Material and labour for street light fitting, powder coated, pressure die cast aluminium IP 66, 70 watt with 100 lm/watt compact LED light with heat resistant toughened glass with lens, complete and making connection from DB to fitting in and including PVC conduit by using PVC cable with copper conductor of size 2.5 Sqmm 3 core, complete all as specified and directed by Engr-in-charge.
All as per item Sr No 61 here-in-before but 150 watt complete all as specified and directed by Engr-in-charge.
Bracket made out of GI pipe 50 mm medium grade 1.2 mtr long bent to shape with MS flat iron clamps made out of 50x6mm thick mild steel FI including nuts, bolts complete all as specified and directed by Engr-in-Charge.
Material and labour for cement concrete in foundations, filling and mass concrete type C2 1:3:6 with 40mm graded aggregate for foundation of pole complete all as specified and directed by Engr-in-charge.
Material and labour for cement concrete in foundations, filling and mass concrete type B2 1:2:4 with 40mm graded aggregate for coping of pole complete all as specified and directed by Engr-in-charge.
Material and labour for Excavation in trenches in any type of soil, exceeding 1.5m in depth for foundation, laying of cables and getting out complete all as specified and directed by Engr-in-charge.
Material & labour for Sand cushioning to under ground cable 8 cm thick layer below the cable and 15cm thick above the cable complete all as specified & as directed by Engineer-in-charge.
Supply and fixing Brick protection with well burnt sub class ‘B’ brick a butting each other( width wise) across the cable laid in trenches complete all as specified & as directed by Engineer-in-charge.
Material & labour for tubing GI light grade 50mm bore laid in trenches, ducts, floor for protection of cable, fixed to wall or poles including fixing arrangement all as required and directed by Engineer-in-Charge.
Material & labour for Cross arms, bracings, supports, clamps and back plates fabricated out of structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size all as required at site for fixing GI tubing in truly vertical position including two coats of synthetic enamel paint over a coat of red oxide primer as indicated or complete all as specified & as directed by Engineer-in-charge.
Material & labour for Stay assembly with stay rod 20 mm dia, 1.8 mtr in length complete with accessories as shown in electrical Plate No 1 (size of stay strand 7/4.00 mm, stay grip 7/3.15 mm) including loop type insulator large size with overall dimensions 90mmx140 mm dia, clearance of hole 25.5 mm and stay clamps complete all as specified & as directed by Engineer-in-charge.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 16 sq mm to 35 sqmm complete all as specified & as directed by Engineer-in-charge.
Material & labour for Earth continuity conductor or main earthing lead 25x4 mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified & as directed by Engineer-in-charge.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1mcomplete all as specified & as directed by Engineer-in-charge.
Surya & Gautam Builders (BID ID -3051477)
SAJJANHAR ASSOCIATES BUILDERS AND ENGINEERS (BID ID -3043571)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .