Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.9 LQualified III A 28 GF VAISHALI GHAZIABAD GHAZIABAD GHAZIABAD UTTAR PRADESH 201010 | GHAZIABAD | UTTAR PRADESH | 201010 | L1 | Qualified MSE, MII, Category: General | |
| 2 | L2₹82.0 L+₹9,057.62 (0.11%)Qualified 1 97 VINAY KHAND GOMTI NAGAR GOMTI NAGAR GORAKHPUR UTTAR PRADESH 273001 | GORAKHPUR | UTTAR PRADESH | 273001 | L2 | Qualified MII | |
| 3 | L3₹1.1 Cr+₹30.1 L (36.8%)Qualified 0 BAHRAULI BAHRAULI NEAR RAM NARAYAN SCHOOL LUCKNOW UTTAR PRADESH 227308 | 227308 | L3 | Qualified MSE, MII, Category: OBC | |
| 4 | Disqualified OFFICE NO 8 SHD COMPLEX SHATABDI ENCLAVE SECTOR 49 NOIDA NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | - | Disqualified | |
| 5 | Disqualified 8 99 GROUND FLOOR GEETA COLONY NEW DELHI DELHI 110031 | SHAHDARA | DELHI | 110031 | - | Disqualified MSE, Category: General |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
11 Mar 2025, 9:00 amClosed
EIC 4core - 25 sqmm refer annexure-II-A
100000000009Supply of following size LT power cable with Copper conductor as directed by EIC 4core - 16 sqmm refer annexure-II-A
100000000010 Supply of Copper cable of size 4core - 2point5 sqmm for communication refer annexure II-A
100000000011 Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-A
100000000012Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-A
100000000013Installation testing and commissioning of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type rotaryorscroll compressor aircooled refer annexure-II-B
100000000014Installationtesting and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type refer annexure-II-B
100000000015 Installation testing and commissioning of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor units refer annexure-II-B
100000000016 Erection testing and commissioning of suitable size refrigerant grade copper for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexure-II-B
100000000017Laying of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable refer annexure-II-B
100000000018 Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units refer annexure-II-B
100000000019 Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drainrefer annexure-II-B
100000000020 Erection testing and commissioning of rain proof outdoor duty as per IP-66 Electrical control panel annexure-II-B
100000000021 Laying of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed armoured extruded PVC oas directed by EIC 4 core - 4 sqmm refer annexure-II-B
100000000022 Laying of following size LT power cable with Copper conductor XLPEorPVC insulation as directed by EIC 4 core - 6 sqmm refer annexure-II-B
100000000023Laying of following size LT power cable with Copper conductor as directed by EIC 4 core - 25 sqmm refer annexure-II-B
100000000024Laying of following size LT power cable with Copper conductor XLPEorPVCas directed by EIC 4 core - 16 sqmm refer annexure-II-B
100000000025Laying of Copper cable of size 4 core - 2point5 sqmm for communication refer annexure-II- B
100000000026Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-B
100000000027Installing of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-B
100000000028Dismantling and shifting of existing Cassette AC 46 nos and VRV outdoor units of capacity 198 Hp refer annexure II-B
C73340100470Supply of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexureIII-A
C73340001724Supply of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexureIII-A
C73340001821Supply of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil fan motor refer annexureIII-A
100000000029Supply of suitable size Bid Details 2/42 refrigerant grade copper piping between indoor and outdoor units for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexureIII-A
100000000030Providing of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling cassttte AC units refer annexureIII-A
100000000031Providing of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units to refer annexureIII-A
100000000032Providingof cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units complete refer annexureIII-A
100000000033Supply of rain proof outdoor duty as per IP- 66 Electrical control panel with incommer 4 pole MCCB 100 Amp digital voltmeter refer annexureIII-A
100000000034Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY cable confirming EIC 4 core - 4 sqmm refer annexureIII-A
100000000035Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY as directed by EIC 4 core - 6 sqmm refer annexureIII-A
100000000036Supply of following size LT power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XFY as directed by EIC 4 core - 25 sqmm refer annexureIII- A
100000000037Supply of following size LT power cable with Copper conductor XLPEorPVC sheathed 1point1KV by EIC 4 core - 16 sqmm refer annexureIII-A
100000000038Supply of Copper cable of size 4 core - 2point5 sqmm for communication refer annexureIII-A
100000000039Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexureIII-A
100000000040Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexureIII-A
100000000041Installation testing and commissioning of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexure-III- B
100000000042Installation testing and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexure-III-B
100000000043Installation testing and commissioning of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit refer annexure- III-B
100000000044Installation testing and commissioning of suitable size refrigerant grade for 2or2.5or3or4TR Cassette ACorSplit AC unit for suction liquid refer annexure- III-B
100000000045Laying of flexible PVC Duct hose Covering pipe of size 60 mm suitable for exposed refrigerant refer annexure-III-B
100000000046Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure-III-B
100000000047Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure- III-B
100000000048Installation testing and commissioning of rain proof outdoor duty as per IP-66 refer annexure-III-B
100000000049Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV gradeEIC 4 core - 6 sqmm refer annexure-III-B
100000000050Laying of following size LT power cable with Copper conductor XLPEorPVC 1point1KV grade by EIC 4 core - 4 sqmm refer annexure-III-B
100000000051Laying of following size LT Bid Details 3/42 power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XFY cable as directed by EIC 4 core - 16 sqmm refer annexure-III-B
100000000052Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV grade as directed by EIC 4 core - 25 sqmm refer annexure-III-B
100000000053Laying of Copper cable of size 4 core - 2point5 sqmm for communication refer annexure-III-B
100000000054Laying of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-III-B
100000000055Laying of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-III-B
7587515
GEM/2025/B/6007232
Two Packet Bid
C73340001918Supply of Cassette AC four way capacity
45 days
Ghaziabad, Uttar Pradesh
Total value wise evaluation
BOQ
1 document required · 1 mandatory
Exempted
28 Feb 2025
28 Feb 2025
11 Mar 2025
EIC 4core - 25 sqmm refer annexure-II-A
100000000009Supply of following size LT power cable with Copper conductor as directed by EIC 4core - 16 sqmm refer annexure-II-A
100000000010 Supply of Copper cable of size 4core - 2point5 sqmm for communication refer annexure II-A
100000000011 Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-A
100000000012Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-A
100000000013Installation testing and commissioning of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type rotaryorscroll compressor aircooled refer annexure-II-B
100000000014Installationtesting and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type refer annexure-II-B
100000000015 Installation testing and commissioning of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor units refer annexure-II-B
100000000016 Erection testing and commissioning of suitable size refrigerant grade copper for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexure-II-B
100000000017Laying of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable refer annexure-II-B
100000000018 Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units refer annexure-II-B
100000000019 Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drainrefer annexure-II-B
100000000020 Erection testing and commissioning of rain proof outdoor duty as per IP-66 Electrical control panel annexure-II-B
100000000021 Laying of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed armoured extruded PVC oas directed by EIC 4 core - 4 sqmm refer annexure-II-B
100000000022 Laying of following size LT power cable with Copper conductor XLPEorPVC insulation as directed by EIC 4 core - 6 sqmm refer annexure-II-B
100000000023Laying of following size LT power cable with Copper conductor as directed by EIC 4 core - 25 sqmm refer annexure-II-B
100000000024Laying of following size LT power cable with Copper conductor XLPEorPVCas directed by EIC 4 core - 16 sqmm refer annexure-II-B
100000000025Laying of Copper cable of size 4 core - 2point5 sqmm for communication refer annexure-II- B
100000000026Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-B
100000000027Installing of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-II-B
100000000028Dismantling and shifting of existing Cassette AC 46 nos and VRV outdoor units of capacity 198 Hp refer annexure II-B
C73340100470Supply of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexureIII-A
C73340001724Supply of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexureIII-A
C73340001821Supply of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil fan motor refer annexureIII-A
100000000029Supply of suitable size Bid Details 2/42 refrigerant grade copper piping between indoor and outdoor units for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexureIII-A
100000000030Providing of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling cassttte AC units refer annexureIII-A
100000000031Providing of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units to refer annexureIII-A
100000000032Providingof cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units complete refer annexureIII-A
100000000033Supply of rain proof outdoor duty as per IP- 66 Electrical control panel with incommer 4 pole MCCB 100 Amp digital voltmeter refer annexureIII-A
100000000034Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY cable confirming EIC 4 core - 4 sqmm refer annexureIII-A
100000000035Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY as directed by EIC 4 core - 6 sqmm refer annexureIII-A
100000000036Supply of following size LT power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XFY as directed by EIC 4 core - 25 sqmm refer annexureIII- A
100000000037Supply of following size LT power cable with Copper conductor XLPEorPVC sheathed 1point1KV by EIC 4 core - 16 sqmm refer annexureIII-A
100000000038Supply of Copper cable of size 4 core - 2point5 sqmm for communication refer annexureIII-A
100000000039Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexureIII-A
100000000040Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexureIII-A
100000000041Installation testing and commissioning of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexure-III- B
100000000042Installation testing and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexure-III-B
100000000043Installation testing and commissioning of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit refer annexure- III-B
100000000044Installation testing and commissioning of suitable size refrigerant grade for 2or2.5or3or4TR Cassette ACorSplit AC unit for suction liquid refer annexure- III-B
100000000045Laying of flexible PVC Duct hose Covering pipe of size 60 mm suitable for exposed refrigerant refer annexure-III-B
100000000046Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure-III-B
100000000047Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure- III-B
100000000048Installation testing and commissioning of rain proof outdoor duty as per IP-66 refer annexure-III-B
100000000049Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV gradeEIC 4 core - 6 sqmm refer annexure-III-B
100000000050Laying of following size LT power cable with Copper conductor XLPEorPVC 1point1KV grade by EIC 4 core - 4 sqmm refer annexure-III-B
100000000051Laying of following size LT Bid Details 3/42 power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XFY cable as directed by EIC 4 core - 16 sqmm refer annexure-III-B
100000000052Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV grade as directed by EIC 4 core - 25 sqmm refer annexure-III-B
100000000053Laying of Copper cable of size 4 core - 2point5 sqmm for communication refer annexure-III-B
100000000054Laying of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure-III-B
100000000055Laying of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness refer annexure-III-B
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_7587515.pdf
GEM_BID
ATC_casAc_e62c7ad6-98a2-48f1-ac201740736111800_buyer26.belb.up.pdf
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
atc_casac_2025-02-28-15-09-40_36655ccaa0b3e0a39355dde5582a6be5.pdf
BOQ
ac_2024-12-31-16-33-42_e0c16504d7797708812ea76cec3f_2025-02-28-15-09-40_611b0855605731801988635479ec4cb8.csv.pdf
BOQ
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .