Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC 309 VINAYAK TOWER CUTTACK PURI ROAD BHUBANESWAR 751 006 | KHORDHA | ODISHA | 751006 | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹18.1 L+₹4.0 L (28.6%)Rejected-Finance | L2 | Rejected-Finance Being L2 bidder | |
| 3 | L3₹18.1 L+₹4.1 L (28.9%)Rejected-Finance NEAR SOLAPOKHARI PO INS CHILKA DIST KHURDA ODISHA 752 037 | KHORDHA | ODISHA | 752037 | L3 | Rejected-Finance Being L3 bidder |
| Sl No | Description | Qty | Unit | SWAIN ENGINEARING L2 | Shree Mahavir Associates L1 | S C MOHANTY L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for preparation of old painted surfaces of wall and applying one coats of Oil bound distemper on walls complete all as specified and directed | 1,450 | Sqm | 55 ₹79,750 | 40 ₹58,000 | 32 ₹46,400 Lowest |
| 2.00 | M&L for preparation of old surfaces of ceiling and applying one coats of white washing on ceilings complete all as specified and directed. | 200 | Sqm | 38 ₹7,600 | 18 ₹3,600 Lowest | 35 ₹7,000 |
| 3.00 | M&L for preapartion of old painted surfaces of wall by complete removal of existing treatment and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over surfaces complete all as specified and directed | 1,260 | Sqm | 165 ₹2,07,900 | 110 ₹1,38,600 | 41 ₹51,660 Lowest |
| 4.00 | M&L for complete removal of existing treatment on walls and applying wall care putty of 2 mm thickness over plastered surface to prepare the surface even and smooth and one coat of alkali resistant primer paint and two coat of oil bound distemper on walls etc complete all as specified and directed. | 550 | Sqm | 320 ₹1,76,000 | 130 ₹71,500 | 84 ₹46,200 Lowest |
| 5.00 | M&L for preparation of old painted steel and iron surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint (First quality) complete all as specified and directed | 200 | Sqm | 75 ₹15,000 | 88 ₹17,600 | 41 ₹8,200 Lowest |
| 6.00 | M&L for preparation of old previously treated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of synthetic enamel paint (ordinary tint) complete all as specified and as directed. | 250 | Sqm | 80 ₹20,000 | 79 ₹19,750 | 45 ₹11,250 Lowest |
| 7.00 | Taking down cement plaster on brick walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. | 30 | Sqm | 94 ₹2,820 | 45 ₹1,350 Lowest | 47 ₹1,410 |
| 8.00 | M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM in 1:6 including demolition of old brick work built in cement mortar complete all as specified and directed. | 1 | Cum | 6,000 ₹6,000 | 6,000 ₹6,000 | 3,510 ₹3,510 Lowest |
| 9.00 | M & L for rendering 10 mm thick in CM 1:6 on on fair faces of brick/concrete wall surfaces of any description and finishing surfaces even and smooth without using extra cement complete all as specified and directed. | 25 | Sqm | 240 ₹6,000 | 155 ₹3,875 | 123 ₹3,075 Lowest |
| 10.00 | M & L for Rendering 15 mm thick in CM 1:4 on other than fair faces of brick/concrete wall surfaces of any description and finishing surfaces even and smooth without using extra cement complete all as specified and directed. | 25 | Sqm | 320 ₹8,000 | 188 ₹4,700 | 180 ₹4,500 Lowest |
Tender Value
₹18.7 L
EMD Value
₹37,440
Closing Date
28 Aug 2025, 6:00 pmClosed
Shri Himanshu IDSE EE
GE (I)(CG) Bhubaneswar, Military Engineer Services, Near School Integral Education, Campus-2, Coast Guard Complex, Pallaspalli, Bhubaneswar-751 020 (Odisha)
COMPREHENSIVE MAINT OF MD AND OTM ACCN SUCH AS PERIODICAL JOINERY PLUMBING MASONRY INCLUDING MISC ITEMS AND REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION AND COOLING APPLIANCES AND CONNECTED WORKS AT CGRA COMPLEX AND OTM ACCN AT ICG GOPALPUR
2025_MES_717879_2
8586/BBSR/04/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Gopalpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (I) (CG) Bhubaneswar
₹37,440
Yes
29 Sept 2025
4 Aug 2025
30 Aug 2025
4 Aug 2025
28 Aug 2025
14 Aug 2025
Amount
M&L for preparation of old painted surfaces of wall and applying one coats of Oil bound distemper on walls complete all as specified and directed
M&L for preparation of old surfaces of ceiling and applying one coats of white washing on ceilings complete all as specified and directed.
M&L for preapartion of old painted surfaces of wall by complete removal of existing treatment and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over surfaces complete all as specified and directed
M&L for complete removal of existing treatment on walls and applying wall care putty of 2 mm thickness over plastered surface to prepare the surface even and smooth and one coat of alkali resistant primer paint and two coat of oil bound distemper on walls etc complete all as specified and directed.
M&L for preparation of old painted steel and iron surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint (First quality) complete all as specified and directed
M&L for preparation of old previously treated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of synthetic enamel paint (ordinary tint) complete all as specified and as directed.
Taking down cement plaster on brick walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM in 1:6 including demolition of old brick work built in cement mortar complete all as specified and directed.
M & L for rendering 10 mm thick in CM 1:6 on on fair faces of brick/concrete wall surfaces of any description and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for Rendering 15 mm thick in CM 1:4 on other than fair faces of brick/concrete wall surfaces of any description and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for praparation of new plastered surface of wall of any description and applying two coat of oil bound distemper over and including a coat of primer and 2mm thick wall care putty complete all as specified and directed.
M& L for preparation of new plastered surface of wall and applying Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and directed
S&F in repairs chromium plated long body fancy type bib taps with wall flange, cast copper alloy with round operating knob screwed down high pressure, screwed for 15 mm bore iron pipe complete all as specified and directed.
S&F in repairs chromium plated pillar taps, fancy type of size 15mm dia, cast copper alloy, with capstan heads, chromium plated, fancy type screwed down high pressure, with or without lettered 'Hot or Cold' with long screwed shanks and flynuts, screwed for iron pipe complete all as specified and directed.
S&F in repairs Stop Valves (Angular stop cock) 15 mm bore dia pipe, Chromium Plated, Fancy Type, screwed down,high pressure screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair for spindel of 15mm bore CP cast copper Alloy bib cock/angle cock complete all as specified and directed.
S&F in repairs PP-R Gate valves (brass insert) as per requirement of the site of size 25 mm outer dia of pipe complete all as specified and directed.
S&F in repairs CP Health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook incluiding making connections and fixed in position incl, fixing in pipe etc complete all as specified and as directed.
S&F in reapirs Brass chromium plated shower roses of size 125mm with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F in reapirs 10 Ltr Capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and 32mm dia PVC flushing pipe complete all as specified and directed.
S&F in repairs two way Bib Taps, cast copper alloy, 15 mm bore dia of pipe, Chromium Plated, with crutch or butterefly handle, screwed down for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repairs Brass chromium plated bottle traps 32mm bore for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap complete all as specified and directed.
S&F 20mm bore dia pipe of 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc including taking down old unserviceable steel/PP-R pipe complete all as specified and directed.
S&F in repairs 20mm Dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) complete all as specified and directed.
M&L for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity exc 500 litre but n exc 2000 litre capacity complete all as specified & directed.
S&F in repairs Grating round 140 mm size of PTMT (Minimum weight 50gms) complete all as specified and directed.
S&F in repairs Vitreous China wash basin, white, flat back, size 630x450mm excluding taps, waste, chain and plug and porcelain stopper but including brackets with cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed.
S&F in repairs vitreous china pedestal type water closet, white (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete and making good to floor complete all as specified and directed.
S&F in repairs Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessorieslike rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified.
S&F in repairs Plastic water closet seat cover, in any colours, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repairs Vitreous china urinal partition white of size 310x700 mm and of slabs terminating about 40cm above floor line complete all as specified and directed.
S&F in Repairs Vitreous China urinals, half stall type, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
S&F in repairs Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed.
S&F Brass CP 15mm bore Swan neck tap with Medium Swivel Spout including Brass Check nuts, Rubber Washer complete all as specified and directed.
S&F in repairs Brass CP mixer 15mm bore for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F in reapairs PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
Supply and fixing in repairs 32mm PVC waste pipe for wash hand basin., 900mm long. complete all as specified and directed
S&F PVC (SWR) pipes 110MM Dia single socketed in any length with rubber ring joints fixed to walls at any height incluiding scaffolding as required at site including taking down old PVC pipe complete all as specified and directed.
S&F PVC (SWR) Bends of any radius for bore dia 110mm at any height incluiding scaffolding as required at site complete all as specified and directed.
S&F PVC (SWR) pipes 75MM Dia single socketed in any length with rubber ring joints fixed to walls at any height incluiding scaffolding as required at site including taking down old PVC pipe complete all as specified and directed.
S&F PVC (SWR) Bends of any radius for bore dia 75mm at any height incluiding scaffolding as required at site complete all as specified and directed.
M&L for Hacking out old broken glass (any thickness, size, quality or description) from aluminium doors / windows / wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
M&L for 5.50mm thick Sheet glass, ordinary quality and glazing with rubber beads/ gaskets/ oil putty as required at site in square exc 0.5 sq. m in each pane complete all as specified and directed.
S&F in repairs stainless steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or stainless steel wire staples complete all as specified and directed.
M&L for Double Charged Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incluiding Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes including dismantling of old tiles including cement mortar bedding complete all as specified and directed.
M&L for Non-skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incluiding Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes including dismantling of old tiles including cement mortar bedding complete all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incluiding Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 for fixing of Tiles including dismantling of old tiles including cement mortar bedding complete all as specified and directed.
M&L Granite 18-20mm thick (of any Colour any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incluiding rendering 15mm thick in CM 1:4 including dismantling of old stone and cement mortar bedding complete all as specified and directed.
S&F in replacement Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws upto 20 mtr height including necessary scaffolding/ hydra machine as required at site complete all as specified and directed.
S&F in replacement 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc. at site complete all as specified and directed.
S&F in repairs bright finished Stainless steel 304 grade droppery rod 1mm thick 25mm bore dia with fancy type brackets including end caps complete all as specified and directed.
S&F in replacement Zebra Blinds/Roller Blinds of size from 25mm to 75mm as required (as combination of colour approved by user White/Blue/Red etc)for Windows Home Décor Windows Zebra Blinds for Window Roller Blinds Room Darkening Roller Blinds for home, Office of window with complete functioning arrangement including all fitting/fixtures complete all as specified and directed.
S&F in repairs Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S&F in repairs toilet paper holder of brass chromium plated with flat recessed type SS fixed to walls with chromium plated (CP) brass screws Complete all as specified and directed."
S&F in repairs door closer Aluminium (extruded section Body) hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and directed.
Taking down chowkats or frames with shutters not exc 1.5 Sqm each (w/o taking Each off shutters from the frames) and removing from site complete all as specified and directed.
Taking down chowkats or frames with shutters exc 1.5 Sqm but n exc. 4 Sqm each (w/o taking Each off shutters from the frames) and removing from site complete all as specified and directed.
Taking down shutters of any description of area exc 1 sq.m and n exc 2 sq.m each and removing from site complete all as specified and directed.
M&L for 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints etc. all as specified and directed.
S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 35mm thick Glazed and skeleton shutters,of 2nd class hard wood, open rebated and prepared to receive glass,gauze, etc. (with sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
S&F powder coated anodised aluminium frame for doors, windows, ventilators etc complete,all as specified and as directed.
S&F for Powder Coated Anodised aluminium window and ventilator shutters, Sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified. (Note : Glass pane shall be measured and paid separately)
S&F for powder coated Anodised aluminium door shutters,aluminium section weighing 0.55 kg/ m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
S&F 100mm size stainless steel butt hinges fixed propely in correct alignment with necessary screws complete all as specified & directed.
S&F 125 mm size Aluminium handles, cast type, anodised complete all as spcified and directed.
S&F 150 mm long Extruded aluminium alloy handles, fabricated type, anodised including necessary screws complete all as specified and directed.
S&F 150mm long Aluminium anodised, barrel tower bolts of extruded section and fixed including necessary screws and fixing arrangements complete all as specified and directed.
S&F 150 mm long Extruded aluminium alloy handles, fabricated type, anodised including necessary screws complete all as specified and directed.
S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F aluminum alloy, anodized, sliding door bolt of length 300mm with hasp & staple (bolt type) & fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified and directed.
Supply and fixing for Tinted Sheet glass 4.0mm thick in square exc 0.5 sq. m etc. complete all as specified and directed.
Dismantling of wall and ceiling boards of any thickness, including cover fillets etc. complete all as specified and directed.
M&L for 18-20 mm thick medium density fibre board, exterior grade, both side laminated with 0.9 mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions, fixed to timber framework with screws as required complete all as specified and directed.
M&L for 2nd class hardwood plain fillets, square, rectangular or triangular in section, sectional area exceeding 13 Sqm but not exceeding 25 sqm, clean sawn, secured with nails or brads as required complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description not exceeding 10cm width or girth and applying two coats of synthetic enamel paint when unconnected with other painting or when painted in different tint complete all as specified and directed.
S&F Continuous (piano) hinges, stainless steel, bright finish or electrogalvanised with 40mm width of flaps complete all as specified and directed.
S&F in repairs 150 mm Long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F in repairs 300mm long MS ordinary rat tail rod pattern springs including roller and roller plate complete complete all as specified and directed.
S&F in repair door seal of aluminum sheet with nylon brush fixed with screw of length varies from 0.75 to 1.00m complete all as specified and directed.
Demolition of RCC Cover slabs of any description and in any position not otherwise specifically provided for complete all as specified and directed
M&L for Providing precast cover slabs as in cover slabs over Drains/Manholes of Type B1 1:2:4 (20mm graded aggregate) with joints to set in cement mortar 1:6 complete all as specified and directed.
M&L 10mm dia & over TMT Bars cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Certain repair works like refixing of loose curtain brackets, adjust loose builders hardware, repairs dislocked bib tap etc, where required including new screws, bolt, washers etc if required complete all as specified and directed.
M&L for Cleaning/removal of blockage from Nahani trap, floor trap, gully trap, IWC, EWC including CI or/ UPVC pipe or any other type of pipe including its junction to outside of wall to complete all as specified and directed.
Taking out carefully Precast RCC cover slab of septic tank excavating and taking out sludge including foul water in a closed container by mechanical process or manual process transporting to a distance exc 1KM and depositing the same in excavated earthen pit of suffiecent size and depth in any type of soil outside the defence land, where directed to a distance exc 1KM returning, filling in earth into excavated pit disposed of at BMC identified area after every disposal of sludge cleaning inspection pit, sludge chember inlet and outlet pipe cleaning MS rungs etc complete for septic tank capacity from 25 user to 500 users cleaning the septic tank with fresh water complete all as specified and directed.
Taking out carefully the cover slab of each manhole of depth from 1.0 metre to 2.00 metre and removing the sludge by mechanical process or manual process transporting to a distance exc 250 m but not exc 500 m and depositing the same in excavated earthen pit of sufficient size and depth of any type of soil within the defence land, where directed including returning, filling of earth in excavated pit after every disposal of sludge etc. and cleaning with fresh water, placing the cover slab in position complete all as specified and directed.
Cleaning of blockage sewage line manually and then with fresh water of pipe 100 mm dia / 150 mm dia or above in between man holes and passing rubber ball of suitable size through line to ensure all blockage perfectly clear to the entire satisfaction of Engineer-in-Charge complete all as directed.
Taking down carefully copper/aluminium point wiring including sunken MS boxes (light, fans, socket or power) complete, (fittings such as switches, ceiling roses,call bell, pendants, regulators, socket etc by unscrewing from board carefully and making good disturbed surfaces of walls, floors etc complete all as specified & directed.
M&L for point wiring with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm for earth continuity wire, to be drawn in and including PVC conduit heavy duty with concealed wiring, MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick switch board and brass screws with cap washers for one light/Fan point controlled by one single way switch including all necessary wall cutting and making good disturbed surface complete all as specified & directed.(Make of wire: .(Make of wire: Finolex/Polycab/Plaza Make of PVC Conduit :-Plaza/Prestoplast/Precision)
M&L Point wiring for one light point or one fan point controlled by one switch with two runs of FRLS grade PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLS grade PVC insulated unsheathed stranded copper conductor as for earth continuity wire to be drawn in and including PVC casing & caping ( medium grade) not less than 25 mm width with fittings & fixtures including MS sheet metal switch / terminal box 1.22 mm thick upto (200x300)mm size duly covered with backelite sheet cover 3.00mm thick and continutiy conductor shall be connected to common earth and earth dolly and making good disturbed surface to walls complete all as specified & directed . (Make of wire: .(Make of wire: Finolex/Polycab/Plaza Make of PVC Casing-N- Caping :-Plaza/Prestoplast/Precision)
All as per here and before item No-94 above but Concealed wiring in Existing Conduit .
All as per here and before item No-94 above but for one light point controlled by one two way switch
All as per item No. 94 above but for call bell point.
All as per item No. 94 above but one 3 pin socket outlet 5 Amps on same board.
All as per item No. 94 above but one 3 pin socket outlet 5 Amps but independent board with cable 1.5 Sqmm two run & 1.5 Sqmm one run of earth continuty.
All as per item No.94 here in before but for 5/15 Amps point on independent board with two runs of 2.5 Sqmm FRLS grade PVC insulated unsheathed stranded Copper conductor and 2.5 Sqmm, FRLS grade PVC insulated, unsheathed, stranded copper conductor as earth wire.
M&L Sub main wiring using two runs of FRLS grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 1.5 Sqmm and one run of 1.5 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old unserviceable sub main wiring complete all as specified & directed. Note : Two runs of 1.5 Sqmm copper wire,one run of 1.5 Sqmm wire & one run PVC Conduit shall be measured as one unit.
M&L Sub main wiring using two runs of FRLS grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 2.5 Sqmm and one run of 2.5 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old unserviceable sub main wiring complete all as specified & directed.Note : Two runs of 2.5 Sqmm copper wire,one run of 2.5 Sqmm wire & one run PVC Conduit shall be measured as one unit.
M&L Sub main wiring using two runs of FR grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 4.0 Sqmm and one run of 4.0 Sqmm FR grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old unserviceable sub main wiring complete all as specified & directed.Note : Two runs of 4.0 Sqmm copper wire,one run of 4.0 Sqmm wire & one run PVC Conduit shall be measured as one unit.
Supply and fixing in replacement of Step type electronic Fan regulator flush switch type on the existing phonolic laminated sheet etc as required as existing type and size complete all as specified & directed.
Supply and fixing in replacement including connection of modular switch one way 6 Amps 1 Module complete all as specified and directed.
Supply and fixing in replacement including connection of modular switch one way 16 Amps 1 Module complete all as specified and directed.
Supply and fixing in replacement modular Bell push 6A 1 Module complete all as specified and directed.
Supply & fixing in replacement including connection modular socket outlet 2 /3 pin 6 Amps 2 modules complete all as specified and directed.
Supply & fixing in replacement including connection modular socket outlet 2 /3 pin 6/16 Amps 2 modules complete all as specified and directed.
Supply and fixing in replacement of Modular Fan regulator,120 watts complete all as specified and directed.
Supply and fixing in replacement white modular cover plate with frame including metal flush box 1 Module complete all as specified and directed.
Supply and fixing in replacement white modular cover plate with frame including metal flush box 2 Module complete all as specified and directed.
Supply and fixing in replacement white modular cover plate with frame including metal flush box 3 Module complete all as specified and directed.
Supply and fixing in replacement white modular cover plate with frame including metal flush box 4 Module complete all as specified and directed.
Supply and fixing in replacement white modular cover plate with frame including metal flush box 6 Module complete all as specified and directed.
Supply and fixing in replacement white modular cover plate with frame including metal flush box 8 Module complete all as specified and directed.
Supply and fixing in replacement of Modular Fan regulator,120 watts two modular complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed mounted or surface mounted type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed..
Supply and fixing in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing in replacement round/square shape 12 watt 220 volts AC recessed or surface mounted type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Taking down old Unserviceable DB including fittings/fixtures with MCBs of any make and size complete all as specified and directed.
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 4 way, 240 Volts fixed in wall,making good disturbed surfaces, complete all as specified and directed.
Supply and fixing in replacement ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with minimum service value 5.10 cubic meter/minute/watt. Five star rated with brushless direct current motor (BLDC) complete with remote control complete all as specified and directed.
S&F in replacement Isolator, TPN, 415 Volt 63 A complete all as specified and directed.
All as per item No. 124 above but TPN, 415 Volt 100 A complete all as specified and directed.
S&F MCB, SPN. 6-32 Amps rating 240, volt, 'C' series, 10 kA complete all as specified and directed.
S&F in replacement MCB SP, 6-32 Amps, 240 volt, 'C' Series, 10 kA complete all as specified and directed.
S &F in replacement MCCB 4 pole 160 Amp ,415 Volt ,36 KA complete all as specified and directed.
S&F in replacement MCB DP, 40 Amps, 240 volt, 'C' Series, 10 kA complete all as specified and directed.
S&F in replacement MCB DP, 32 Amps, 240 volt, 'C' Series, 10 kA complete all as specified and directed.
Supply and fixing High-quality design LED Tube light fittings in extruded aluminium housing with high quality PC diffuser 1x20 watt with enhances safety and relible ,robust housing structure with decorative end caps complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed.
Supply & fixing in repair Building security light fitting,new compact designed IP 66, Aluminium PDC housing with toughen glass cover high power LED street light/Building Security light of capacity 25 watt.including provn of necessary connection complete all as specified and directed.
Supply and fixing in repair of GI pipe Bracket of 40 mm dia Medium grade pipe bend to shape of approx length 1.5 Mtr including 2 no. MS Clamp of flat iron size 40x6 mm complete with nut, bolt, washers complete all as specified and directed.
Supply and fixing in repair sheet metal encloser box including Plug and socket with 20 Amps MCB (SP) 10 KA, C Series with taking down old U/S existing sheetmetal enclosure complete all as specified and directed. ( Make L&T/Legrand /Standard).
Supply only PVC holder stand for capacitor of ceiling fan 1200mm sweep complete all as specified and directed.
Supply only capacitor 230 Volts AC 50 HZ and rated capacity 2.5 MFD for ceiling fan complete all as specified and directed.
Supply only capacitor 230 Volts AC 50 HZ and rated capacity 1.25 MFD for ceiling fan complete all as specified and directed.
Supply only capacitor 230V AC 50 HZ and rated capacity 3.15 MFD for exhaust fan complete all as specified and directed.
S&F PVC insulated, sheathed twin twisted stranded copper conductor flexible cable of size 1.5 Sqmm for ceiling fan complete all as specified & directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm completed all as speciifed and directed.
S&F gun metal bush of suitable size for exhaust fan of any type / size as per existing type complete all as specified and directed.
S&F MS hook and clamps MS flat iron of existing size after taking out old rusted hook & clamp etc.for hanging/fixing of ceiling fan including cemented work complete all as specified and directed.
S&F MS anodized bolts with anodized nuts, spring washers split pin etc size 50 mm long 10 mm dia half threaded type with split pin hole for hanging of ceiling fan complete all as specified and directed.
S&F in repairs down rod of suitable size including gromet/ reel type rubber pad with clamp & bolts, nuts and washers suitable for housing ceiling fan complete all as specified and directed.
S&F in repairs louvers shutter made of MS sheet metal 1.2 mm thick for round base and 0.8mm thick for flaps confirming of mounting edges frames made of MS Flat of size 25mmx3mm including heavy duty rust proof passivated bolts, of size 50mm long 8mm dia to be fixed on wall after drilling and duly painted by two coats of synthetic enamelled paint (spray painting) over a coat of primer for exhaust fans up to size 300 - 450 mm sweep complete all as specified and directed.
S&F in repairs of PVC plug top of 5 Amps, 3 pin,230 volts complete all as specified and directed.
S&F in repairs of PVC plug top of 15 Amps, 3 pin,230 volts complete all as specified and directed.
S&F in repairs of Metallic plug top of 20 Amps, 3 pin,230 volts complete all as specified and directed.
Supply and Replacement of Incoming cable with 3-core,PVC Stranded copper conductor of sizes 1.5 sq.mm with taking down of old unserviceable incoming cables complete all as specified and directed.
S&F Modular switch 2 way 6A, 1 module complete all as specified and directed.
S&F in replacement Switch piano, flush type, single pole, one way 5 Amps, 240V complete all as specified and directed.
S&F Switch piano, flush type, two pole, two way 5 Amps, 240V complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way 15 Amps, 240V complete all as specified and directed.
S&F Bell push Switch, flush type, single pole, one way 5 Amps, 240V complete all as specified and directed.
S&F Call Bell ,Ding-Dong ,single pole, AC, 230 Volts complete all as specified and directed.
S&F in replacement Switch socket combination 2 in 1, 5 pin, 5 Amps flush type 240 Volt including box complete all as specified and directed.
S&F Socket outlet 2 in 1, 5 pin, 5 Amps flush type 240 Volt complete all as specified and directed.
S&F in replacement Socket outlet 2 in 1, 5 pin, 5/15 Amps flush type 240 Volt complete all as specified and directed.
S&F in replacement Switch socket combination 5/15 Amps flush type,6 pin,5 in 1 complete all as specified and directed.
S&F in replacement Ceiling rose,3 terminal PVC/poly carbonate isolated body complete all as specified and directed.
M&L for services of jointing/taping or checking the electrical connections and securing after defect rectification in existing points/connection/items for light/call bell/ fan/regulators/capacitor/ sockets/ switches/ceiling rose/ switch socket boards/ junction boxes /metal/MCB sockets/power sockets or connected circuits till MCB control in DB/earthing complete and refixing the existing items after defect rectification, as and when required/directed complete all as specified and directed. Note: (i) Sufficient electrician /helper and other required items are to be provided immediately for repair as and when intimated (ii) The defect rectification of all connected items in the same circuits/ switch socket board will be counted as one job only (iii) Necessary tapping jointing lugging, minor connecting wires and securing and other minor items to make good the defects is deemed to be included complete all as specified and directed.
Dismantling of Split type Air Conditioner, of any capacity & 'make', opening up for servicing, inspection / examination for serviceability of compressor, fan, motor, relays,PCB of indoor and outdoor units, capacitors, cleaning the evaporator and condenser with compressed air/ water as required, lubrication of moveable parts, replacement of worn out bolts , screws, rubber gaskets, seals, terminal & link clips, unserviceable wiring, rubber mounting for compressor including all minor spare parts for carrying out servicing including reassembling & testing of AC, complete all as specified and directed.
SWAIN ENGINEARING (BID ID -3401529)
S C MOHANTY (BID ID -3409642)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .