GEMC-511687749080797
Awarded to MITI ELECTRONICS PRIVATE LIMITED
₹1.4 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Syringe Infusion Pump | Fresenius kabi Model Infusia SP7 | - | 5 NOS | ₹27,999 | 139,995 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.4 LQualified Make: Fresenius Kabi
Model: Fresenius kabi Model Infusia SP7 14 11 MADHURAM FLATS 3RD MAIN ROAD KANNAPPA NAGAR THIRUVANMIYUR CHENNAI TAMIL NADU 600041 | CHENNAI | TAMIL NADU | 600041 | Make: Fresenius Kabi
Model: Fresenius kabi Model Infusia SP7 | L1 | Qualified | |
| 2 | Qualified Make: Fresenius Kabi
Model: Fresenius kabi Model Infusia SP7 197 JLPL INDUSTRIAL PARK SECTOR 82 MOHALI MOHALI PUNJAB 140306 | S A S NAGAR | PUNJAB | 140306 | Make: Fresenius Kabi
Model: Fresenius kabi Model Infusia SP7 | - | Qualified | |
| 3 | L2₹1.4 L+₹4.50 (<0.01%)Disqualified Make: Mindray Medical
Model: MINDRAY 197 JLPL INDUSTRIAL PARK SECTOR 82 MOHALI MOHALI PUNJAB 140306 | S A S NAGAR | PUNJAB | 140306 | Make: Mindray Medical
Model: MINDRAY | L2 | Disqualified | |
| 4 | Disqualified Make: ALLIED
Model: Make: Allied Medical Ltd., Model: Syrn200 203 SWASTIK BHAWAN COMMERCIAL COMPLEX CENTRAL DELHI RANJEET NAGAR CENTRAL DELHI DELHI 110008 | WEST DELHI | DELHI | 110008 | Make: ALLIED
Model: Make: Allied Medical Ltd., Model: Syrn200 | - | Disqualified | |
| 5 | Disqualified Make: KellyMed
Model: Kelley med KL602 A 38 1ST FLOOR NARAINA INDUSTRIAL AREA PHASE 1 NARAINA INDUSTRIAL AREA PHASE 1 SOUTH WEST DELHI DELHI 110028 | NEW DELHI | DELHI | 110028 | Make: KellyMed
Model: Kelley med KL602 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
10 Aug 2018, 4:00 pmClosed
Infusion Pump Volumetric/Syringe Based Infusion Pump Volumetric/Syringe Based ( 5 ) Technical Specifications Specification Specification Name Values Allowed Values Standards Availability of any of Certification such as ISO/European-CE US-FDA/CE YES YES Details of the Certifications such as type of certification
nu mber
date and validity - - Conformity to Standards YES - Performance Parameters Type of Infusion Pump Syringe Infusion Pump Volumetric Infusion Pump
Syringe Infusion Pump Technology (of operation) Programmable Mode Programmable Mode
Continous Mode Flow rate Range with increment in ml/hr 1.1 to 840 ml/hr(50 ml syringe) 0.1-99.9 ml/hr(0.1 ml/hr increment) for Volumetric Infusion Pump Only
1-1200 ml/hr(1 ml/hr increment) for Volumetric Infusion Pump Only
0.1 to 240 ml/hr(10 ml syringe)
1.1 to 400 ml/hr(20 ml 1/6 syringe)
1.1 to 600 ml/hr(30 ml syringe)
1.1 to 840 ml/hr(50 ml syringe)
1.1 to 999 ml/hr(100 ml/hr syringe) Infused Volume Range in ml 0.1-999(0.1 ml/hr increment) 0.1-999(0.1 ml/hr increment)
1-9999(1 ml/hr increment) Flow rate & volume flow rate & volume to be infused should be configured to limit the maximum allowable range - KVO (Keep Vein Open) Rate in ml/hr 1 Accuracy in % 2 Bolus Type Bolus with volume pre- selection Bolus with volume pre- selection
Bolus without volume pre- selection
Interval Bolus
Purge Bolus ( For Syringe based)
Auto Bolus (For Syringe based) Bolus Rate Range in ml/hr 800 ml/hr for 50 ml syringe 1-600 ml/hr ( for Volumetric type infusion set)
200 ml/hr for 10 ml syringe
360 ml/hr for 20 ml syringe
560 ml/hr for 30 ml syringe
800 ml/hr for 50 ml syringe
999 ml/hr for 100 ml syringe Bolus Volume in ml 0.1-99.9/500 ml 0.1-99.9/500 ml
0.1 ml to 5 ml in 0.1 ml increments(auto bolus)
NA for Purge bolus Display Type LCD - Size of Display (length x width) (mm x mm) - - Contents of Display - - Alphanumeric Programming Key Board YES - Operating and Transportation Temperature range - - 2/6 Humidity Conditions (operating and transport & storage) (15 to 90%) YES - Pressure Conditions(operating and transport & storage) (50 to 106 kpa) YES - Power sources Battery operated - Battery Type Reachareable lithium polymer - Battery Rating - - Battery run time at normal delivery rate in hours 8 - Battery run time at highest delivery rate in hours 2-3 hrs - Battery recharge time (full charge) in hours 10 - Power Supply 220-240 V AC
50 Hz) (3 wire grounded system) YES - Eectrical Protection (Class I
Type CF) YES - Fuse Type 220V 2A*2
12V 2A*2 - Maximum Power Consumption in watt 9.5 - Fitting of device on the IV bottle and bag false - IR Sensor to detect the abnormality in IV Bag or bottle false - Audible and Visual alarm facility Should have an audible and visual alarm wtth automatic pump stop function for the following : pressure drop
air standby
volume infused
door open
battery Pre- alarm
recall
invalid rate
empty etc - Availability of Infusion mode setting(rate mode
drip mode
wait mode
time mode) true - 3/6 Protection against fluid ingress - IP*1 - Protected against vertically falling drops of water YES - Capability of Motioning of empty Intravenous bags or bottles false - Warranty in Years 3 1
2
3
4 Dimensional & Material Parameters Dimension (Excluding power cables)(mm x mm x mm) - - Weight(with clamp base)in kg 2.2 - Material (Outer Shell) ABS PLASTIC - Additional Parameters Pole clamp Multi- function mounting clamp YES - Quick titration of rate or dose with volume timing programming YES - Compatible with any standard (PVC) infusion sets available in local indian market YES - Features : compatible with all standard syringes (b) excellent injection function and operation
even small volume injection is accurate (c) dual cpu monitoring function (d)accurate and sensitive pressure sensor detects occlusion pressure accurately (e) smart pulsation compensation function - No of infusion sets supplied with the single unit 10 - Packing (Individual) YES - Reports Type tests reports from a Central Govt lab OR International Laboratory Accreditation Cooperation (ILAC)or their worldwide affiliated/recognized YES - 4/6 labs OR NABL approved lab Test Report No - - Test Report Date - - Name and complete address of the Lab - - Copy of certificates to be provided to buyer on demand after placement of order (Applicable if availability of test report indicated as YES
otherwise put NA) YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 K Kala Alias Saraswathy 605005
RAJIV GANDHI GOVERNMENT WOMEN AND CHILDREN HOSPITAL
100 FEET ROAD
ELLAIPILLAICHAVADY
PUDUCHERRY 5 15
376422
GEM/2018/B/53305
GeM Contract
Infusion Pump Volumetric/ Syringe Based
GeM Contract
15 days
Puducherry; Pondicherry
PRODUCT
Awarded to MITI ELECTRONICS PRIVATE LIMITED
₹1.4 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Syringe Infusion Pump | Fresenius kabi Model Infusia SP7 | - | 5 NOS | ₹27,999 | 139,995 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Infusion Pump Volumetric/Syringe Based Infusion Pump Volumetric/Syringe Based ( 5 ) Technical Specifications Specification Specification Name Values Allowed Values Standards Availability of any of Certification such as ISO/European-CE US-FDA/CE YES YES Details of the Certifications such as type of certification | - | - | - |
| nu mber | - | - | - |
| date and validity - - Conformity to Standards YES - Performance Parameters Type of Infusion Pump Syringe Infusion Pump Volumetric Infusion Pump | - | - | - |
| Syringe Infusion Pump Technology (of operation) Programmable Mode Programmable Mode | - | - | - |
| Continous Mode Flow rate Range with increment in ml/hr 1.1 to 840 ml/hr(50 ml syringe) 0.1-99.9 ml/hr(0.1 ml/hr increment) for Volumetric Infusion Pump Only | - | - | - |
| 1-1200 ml/hr(1 ml/hr increment) for Volumetric Infusion Pump Only | - | - | - |
| 0.1 to 240 ml/hr(10 ml syringe) | - | - | - |
| 1.1 to 400 ml/hr(20 ml 1/6 syringe) | - | - | - |
| 1.1 to 600 ml/hr(30 ml syringe) | - | - | - |
| 1.1 to 840 ml/hr(50 ml syringe) | - | - | - |
| 1.1 to 999 ml/hr(100 ml/hr syringe) Infused Volume Range in ml 0.1-999(0.1 ml/hr increment) 0.1-999(0.1 ml/hr increment) | - | - | - |
| 1-9999(1 ml/hr increment) Flow rate & volume flow rate & volume to be infused should be configured to limit the maximum allowable range - KVO (Keep Vein Open) Rate in ml/hr 1 Accuracy in % 2 Bolus Type Bolus with volume pre- selection Bolus with volume pre- selection | - | - | - |
| Bolus without volume pre- selection | - | - | - |
| Interval Bolus | - | - | - |
| Purge Bolus ( For Syringe based) | - | - | - |
| Auto Bolus (For Syringe based) Bolus Rate Range in ml/hr 800 ml/hr for 50 ml syringe 1-600 ml/hr ( for Volumetric type infusion set) | - | - | - |
| 200 ml/hr for 10 ml syringe | - | - | - |
| 360 ml/hr for 20 ml syringe | - | - | - |
| 560 ml/hr for 30 ml syringe | - | - | - |
| 800 ml/hr for 50 ml syringe | - | - | - |
| 999 ml/hr for 100 ml syringe Bolus Volume in ml 0.1-99.9/500 ml 0.1-99.9/500 ml | - | - | - |
| 0.1 ml to 5 ml in 0.1 ml increments(auto bolus) | - | - | - |
| NA for Purge bolus Display Type LCD - Size of Display (length x width) (mm x mm) - - Contents of Display - - Alphanumeric Programming Key Board YES - Operating and Transportation Temperature range - - 2/6 Humidity Conditions (operating and transport & storage) (15 to 90%) YES - Pressure Conditions(operating and transport & storage) (50 to 106 kpa) YES - Power sources Battery operated - Battery Type Reachareable lithium polymer - Battery Rating - - Battery run time at normal delivery rate in hours 8 - Battery run time at highest delivery rate in hours 2-3 hrs - Battery recharge time (full charge) in hours 10 - Power Supply 220-240 V AC | - | - | - |
| 50 Hz) (3 wire grounded system) YES - Eectrical Protection (Class I | - | - | - |
| Type CF) YES - Fuse Type 220V 2A*2 | - | - | - |
| 12V 2A*2 - Maximum Power Consumption in watt 9.5 - Fitting of device on the IV bottle and bag false - IR Sensor to detect the abnormality in IV Bag or bottle false - Audible and Visual alarm facility Should have an audible and visual alarm wtth automatic pump stop function for the following : pressure drop | - | - | - |
| air standby | - | - | - |
| volume infused | - | - | - |
| door open | - | - | - |
| battery Pre- alarm | - | - | - |
| recall | - | - | - |
| invalid rate | - | - | - |
| empty etc - Availability of Infusion mode setting(rate mode | - | - | - |
| drip mode | - | - | - |
| wait mode | - | - | - |
| time mode) true - 3/6 Protection against fluid ingress - IP*1 - Protected against vertically falling drops of water YES - Capability of Motioning of empty Intravenous bags or bottles false - Warranty in Years 3 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 Dimensional & Material Parameters Dimension (Excluding power cables)(mm x mm x mm) - - Weight(with clamp base)in kg 2.2 - Material (Outer Shell) ABS PLASTIC - Additional Parameters Pole clamp Multi- function mounting clamp YES - Quick titration of rate or dose with volume timing programming YES - Compatible with any standard (PVC) infusion sets available in local indian market YES - Features : compatible with all standard syringes (b) excellent injection function and operation | - | - | - |
| even small volume injection is accurate (c) dual cpu monitoring function (d)accurate and sensitive pressure sensor detects occlusion pressure accurately (e) smart pulsation compensation function - No of infusion sets supplied with the single unit 10 - Packing (Individual) YES - Reports Type tests reports from a Central Govt lab OR International Laboratory Accreditation Cooperation (ILAC)or their worldwide affiliated/recognized YES - 4/6 labs OR NABL approved lab Test Report No - - Test Report Date - - Name and complete address of the Lab - - Copy of certificates to be provided to buyer on demand after placement of order (Applicable if availability of test report indicated as YES | - | - | - |
| otherwise put NA) YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 K Kala Alias Saraswathy 605005 | - | - | - |
| RAJIV GANDHI GOVERNMENT WOMEN AND CHILDREN HOSPITAL | - | - | - |
| 100 FEET ROAD | - | - | - |
| ELLAIPILLAICHAVADY | - | - | - |
| PUDUCHERRY 5 15 | - | - | - |
Exempted
9 Oct 2018
24 Jul 2018
contract_GEMC-511687749080797.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_376422.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .