Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹3.1 L
Closing Date
27 Aug 2026, 5:30 pmClosed
MR KUNAL AASHISH(DFLT)
SECIRCLE01
NIT 191 Dated 04.08.2026 Construction of road Kudkel to Patelpara Borguda, Length 3.50
197410
NIT 191 Dated 04.08.2026
RESTRICTED TENDER
WORKS
PERCENTAGE
9 days
SECIRCLE01
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
26 documents required · 26 mandatory
Panchayat and Rural Development (PARD)
WORKS
MR KUNAL AASHISH(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
SECIRCLE01
BASTAR 01
SE CIRCLE 01 BASTAR
120
09
No
1
197410
27 Aug, 2026 5:30:00 PM IST
3 Sep, 2026 10:00:00 AM IST
13 Aug, 2026 5:30:00 PM IST
NIT 191 Dated 04.08.2026
NIT 191 Dated 04.08.2026 Construction of road Kudkel to Patelpara Borguda, Length 3.50
311000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
2
2 Sep, 2026 5:30:00 PM IST
AS PER NIT
AS PER NIT
AS PER NIT
5000.00 INR
0d 16h 58m
26 documents required · 25 mandatory · 1 optional
₹5,000
₹3.1 L
27 Aug 2026
13 Aug 2026
3 Sept 2026
13 Aug 2026
2 Sept 2026
Setting Out work complete with construction of bench mark (Min 1 per km) working benchmark (Min 4 per km) and near all bridges and cross-drainage works made of bricks/stone masonary or concrete and reference pillars made of precast concrete poles/concrete filled 100 mm dia A.C.pipe @ 100 m interval of as required on both sides of the formation width, marking on central line, setting out curves and recording of central line levels and other required levels and distances etc. including setting out of cross-drainage structures & bridges with required reference pillars and marking etc. as directed by Engineer-in-Charge.
Clearing grass and removal of rubbish up to a distance of 30 m outside the periphery of the area as per Technical Specification Clause 201. By Manual Means
Compacting Original Ground / Existing Embankment
Surface Drains in Soil
Construction of Embankment with Material Obtained from Pits
Construction of Subgrade and Earthen Shoulders
Granular Sub-base with Well Graded Material (CBR 20 or more) (Table 400.1)
Water Bound Macadam with Stone Screenings
Prime Coat (Low Porosity)
Tack Coat
20mm thick Open-Graded Premix Carpet using Bituminous (VG/modified bitumen) Binder
Seal Coat
Cement Concrete Pavement
Semi-Reflective Traffic signs upto 0.90 sqm
Semi-Reflective Traffic signs more than 0.90 sqm sign board
Providing and Fixing Informtory and Logo Board of PMGSY Project
Providing and fixing 'Citizen Information Board' of PMGSY Project (A) Providing and fixing of typical " PMGSY Citizen Information Board" with Logo as per MoRD specifications & drawings, made of 75 mm square or 75 mm dia circular steel tube of 12 SWG 3.2 m height and cross member 2 nos 1m long, fixed with angle iron 50x50x5 mm MS angle on the back
Kilometre Stones & Boundary Pillar
5th Kilometre Stone (precast)
Ordinary Kilometer Stone (Precast)
200 m stone (precast)
Boundary Pillar Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
Road marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC: 35. The finished surface to be level, uniform and free from streaks and holes.)
Providing & Laying Cement Concrete Pipe NP3 on first class bedding of granular material including fixing collar with cement sand mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonary work in head wall and parapets as per clause 1106 .(A) 600 mm Dia.
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 I. P.C.C grade M 15 (Nominal mix (1:2.5:5)
Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 1 Granular material
Excavation in Cutting in Soil by manual means with lead upto 50 mExcavation for roadway in soil for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3Chainage 19100 TO 19600 & 22400 TO 22900 TO & 38600 TO 39450
Construction of Plain Cement Concrete Drain with P.C.C. grade M-15 including all shuttering/form work etc. complete as per drawings/technical specification and direction of engineer in charge.
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 (12 MM)
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (I.) P.C.C grade M 10
Providing concrete for plain/reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry
Providing concrete for plain/reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 II. P.C.C grade M 15(Nominal mix (1:2.5:5)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 I. P.C.C grade M 15(Nominal mix (1:2.5:5)
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II. R.C.C grade M 20 (Nominal mix (1:2:4)
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 I. R.C.C grade M 25 (ii) For design mix
Filler Joint (II) Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and technical specifications
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 I) Granular material
Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
8869920347676678703_197410_Tender Document NIT 191.pdf
NIT • 1.42 MB
6712046715960758616_197410_BOQ KUDKEL TO PATELPARA BORGUDA.xlsx
BOQ • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .