Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹32.9 L+₹31,165.52 (0.96%)Rejected-AOC | L2 | Rejected-AOC SECOND LOWEST BIDDER | |
| 3 | L3₹34.0 L+₹1.4 L (4.43%)Rejected-AOC | L3 | Rejected-AOC THIRD LOWEST BIDDER | |
| 4 | L4₹34.4 L+₹1.8 L (5.59%)Rejected-AOC | L4 | Rejected-AOC FOURTH LOWEST BIDDER | |
| 5 | L5₹34.9 L+₹2.3 L (7.07%)Rejected-AOC | L5 | Rejected-AOC FIFTH LOWEST BIDDER |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
18 Apr 2023, 6:00 pmClosed
GE Nagrota
Garrison Engineer Nagrota Pin 901208 c/o 56 APO
PROVN OF PATHWAY CATTLE FENCING AT NAGROTA AND PROVN OF ADDN ALTERATION TO BUILDING NO T 405 T 113 T 84 T 303 T 354 T 387 AT REASI UNDER GE NAGROTA
2023_MES_586321_1
GEN-85/2022-23
Open Tender
Civil Works
Works
180 days
Nagrota
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
₹96,000
Yes
15 May 2023
18 Mar 2023
20 Apr 2023
18 Mar 2023
18 Apr 2023
6 Apr 2023
Amount
SCHEDULE ‘A’ PART-I Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation or etc, for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in hard dence soil, complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft / loose soil incl removing excavated material (soil) to a distance not. exc. 50 mtr and depositing where directed at a level nexc 1.5 mtr above the starting point complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil , complete all as specified and directed.
Returing, filling in trenches, incl spreading, levelling, watering and well ramming in layers not exc 25 Cm complete all as specified and directed.
Removing excavated material (soil) to a distance not. exc. 50 mtr and depositing where directed at a level nexc 1.5 mtr above the starting point complete all as specified and directed.
M&L for PCC 1:4:8 type D2, using 40mm graded stone aggregate, as in foundation filing, and mass concrete , etc complete all as specified and directed
M & L TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed.
M&L for Mild steel bars (TMT bars) 5mm dia and over upto and including 10mm dia in strriups,spacers and binders complete all as specified and directed.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions finished fair complete all as specified and directed
M & L for formwork to fair finished surface for sides of concrete foundations, footings, bases of columns, raft and beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed
M&L Reinforced cement concrete M-25 using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
M&L Reinforced Cement Concrete M-25 using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, etc complete all as specified and directed
M&L for brick work with sub class 'B' bricks straight or curved on plan exc. 6m mean radius built in cement mortor 1:4 complete all as specified and directed.
M&L for hardcore of gauge n exc. 63 mm,of broken stone deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L plain cement concrete 1:4:8, type D2( using 40mm graded stone aggregate) 75mm thick as in sub base of floor complete all as specified and directed .
M&L for Rendering 15mm thick in two layers [base layer 10mm in CM 1:4 & finishing layer 5mm thick in cement mortar (1:4)] using water proofing compound in 2nd layer only on brick work or concrete surfaces of wall, surfaces finished even and smooth using extra cement at any height using proper scalffolding & safety precautions complete all as specified & directed. Note : WPC shall not be measured and paid separately.
S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. using steel confirming to Fe-410- W(Gde- E-250) quality- B complete all as specified and as directed.
S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete . using steel confirming to Fe-410- W(Gde- E-250) quality- A complete all as specified and as directed.
M&L for glazed ceramic coloured wall tiles (textured and design as required) in vertical surface 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for 60mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-35 Gde of approved shape, size and colour conferming to IS 15658-2006 and laid over and including 50mm thick sand cushion complete all as specified and directed.
M & L 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado/partition/shelves laid over 20mm thick cement screed layer in CM 1:6 and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed
M&L for plain cement concrete type C1 1:3:6 (20mm graded stone aggregate) as in hold fast bed block etc incl formwork complete all as specified and directed.
M&L for plain cement concrete type B1 1:2:4 (20mm graded stone aggregate) as in coping, benching etc incl formwork complete all as specified and directed.
M&L for Pre-cast cement concrete type B1 1:2:4 (20mm graded stone aggregate) as in road side kerb setting in mortar 1:4 , complete incl necessary formwork complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. with raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed
M&L for rendering 10 mm thick in CM 1:3 on brick work or concrete ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete wall surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. & Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed
M&L for Providing 50 mm thick in two layers ( 25 mm thick each layer ) plain cement concrete 1:2;4 type B-0 usng 12.5 mm graded aggregates in roof padding with galvanised wire netting of 0.60 mm dia and size of mesh 12 mm x 12 mm laid between two layers finished even and smooth without using extra cement complete all as specified and directed. Note : Wire mesh shall be measured & paid for seperately under respective item as supply only
Supply only galvanised wire netting of 0.60 mm dia and size of mesh 12 mm x 12 mm complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighing 3.5 kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application laid over & incl a tack coat of bitumen primer @ 0.40 Litre / sqm & finished by applying biumen 85/25 at the rate of 1.2 kg per sqm, APP membrane shall be laid by torching with 75 mm overlap in longitudinal direction & 100 mm overlap in transverse direction and finished by applying one coat of aluminium paint including cleaning surfaces complete all as specified and directed.
M & L for preparing new plastered ceiling surface and applying three coat of white wash complete all as specified and directed.
M & L for preparing new plastered wall surfaces and applying three coat of white wash complete all as specified and directed.
M & L for preparing old treated plastered wall surfaces by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of cement base paint at any height using proper scalffolding & safety precautions complete all as specified & directed complete all as specified and directed.
M & L for preparing old treated plastered wall surfaces by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spotsand applying one coat of white wash complete all as specified and directed.
M & L for Preparation of new/ untreated steel surfaces, of any description, over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide complete complete all as specified and as directed.
M&L for preparation of wall surface and applying two coats of oil bound emulsion distemper over and incl a coat of primer over & incl 3 mm thick wall care putty complete all as specified and directed
M&L for removal of existing treatment & preparation of wall surface and applying two coats of oil bound emulsion distemper over and incl a coat of primer over & incl 3 mm thick wall care putty complete all as specified and directed
M&L for preparation of new or untreated wall surface and applying two coats of with cement base paint,over & incl a coat of primer at any height using proper scalffolding & safety precautions complete all as specified & directed.
M/S MANISHA BUILDERS
R.K. Works
Nitika electricals and engineers works
Kalsi Engineers and contractors
Mohd Rafiq and Co
R C TRADERS
Modh Hafiz Khan
SUNIL AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .