Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 CrAccepted-AOC NO 1387 1 EDICIA JEEVANANDHAM STREET MOSAKKAVUNDANPALAYAM ERODE 638002 TAMIL NADU | ERODE | ERODE | TAMIL NADU | 638002 | ₹39.6 Cr Quoted ₹35.2 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹35.5 CrRejected-Finance | ₹35.5 Cr | L2 | Rejected-Finance Rejected |
| 3 | L3₹35.8 CrRejected-Finance NO 46 2 K D S ILLAM ARUNAGIRINATHAR STREET CHENNIMALAI POST ERODE DISTRICT 638 051 | ERODE | TAMIL NADU | 638051 | ₹35.8 Cr | L3 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | P K SUBRAMANIAN CONSTRUCTION L2 | SRK ASSOCIATESS L3 | SREE BALAJI ASSOCIATES PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|
| 1.00Clearing scrub Jungle and Surface dressing of the ground. The rate including hire charges of all machineries, removing of all rubbish from site, lead upto 50m, transportat charges and labour charges etc., complete complying with standard specification | ||||||
| 2.00 | Area | 11,827 | Sq.m | 9 ₹1.1 L | 7.5 ₹88,702.50 | 7 ₹82,789 |
| 3.00Providing and constructing cast in situ hydraulic bored piles of 300mm / 450mm diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³ in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of mobalization of all necessary plants, equipment's like piling rigs, temporary casing of appropriate length for setting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method duly through all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc .,Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap). | ||||||
| 4.00 | For Building - 450mm dia pile | 20,061 | RM | 4,850 ₹9.7 Cr | 4,995 ₹10.0 Cr | 4,900 ₹9.8 Cr |
| 5.00 | Supply and conducting Vertical load testing of piles in accordance with as per IS 2911 (Part- IV) - 2013 etc including supply and installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.
Note: After testing and unloading of the superimposed load splaced for the test, the pile should be chipped off 1metre below the ground level. | 1 | Nos | 3,65,000 ₹3.6 L | 3,71,000 ₹3.7 L | 3,50,000 ₹3.5 L |
| 6.00 | Supply Conducting Pile integrity tests (PIT) on the piles under each cluster by using a 6 lbs nylon tipped hand held hammer, glueing sensitive accelerometer on top of the pile by petro wax or petroleum jelly after making the pile head smooth and even by disc grinder, providing stage wise and final report along with relevant conclusions etc., as directed by Client / Engineer-in-charge. as per IS 2911 (Part- IV) - 2013 etc | 1 | Nos | 7,600 ₹7,600 | 7,665 ₹7,665 | 7,500 ₹7,500 |
| 7.00 | Conducting High strain Dynamic load tests at 1M below existing ground level / pile cutoff level as per approved method shall be as per IS 2911 (Part- IV) - 2013 etc .Cost should include preparation of pile head, mobilization of all plant and equipments required for carry out the test as per the approved method. | 1 | Nos | 17,300 ₹17,300 | 17,505 ₹17,505 | 17,000 ₹17,000 |
| 8.00Earth work excavation for all foundations in all type of soils and sub soils to the required depth for Footings, plinth / grade beams, etc,. by mechinaries including manual excavation for the following type of soil / rock as per detailed specification. As per SS 20B as hard rock requiring blasting inclusive baling out water wherever necessary and including refilling 0 to 2.0m depth consolidation depositing the surplus earth in places shown clearing and leveling the site with an initial lead of 10 metre and lifts as specified hereunder etc., complete in all respects complying with relevant standard specification and as directed by the departmental officers. | ||||||
| 9.00 | 0 to 2m depth. | 3,252.66 | cu.m | 310 ₹10.1 L | 315 ₹10.2 L | 300 ₹9.8 L |
| 10.00 | 2 to 3m depth. | 33 | cu.m | 320 ₹10,560 | 325 ₹10,725 | 300 ₹9,900 |
Tender Value
Refer Docs
EMD Value
₹16.4 L
Closing Date
16 Jul 2025, 3:00 pmClosed
Superintending Engineer I
Superintending Engineer-I, CW, CMDA, Koyambedu, Chennai
Proposed Construction of Kaivannam Sathukkam Chennai Craft Bazaar at Koyambedu Chennai
2025_CMDAC_580455_1
Tender Notice No.5/2025-26
Open Tender
Civil Works - Others
270 days
Koyambedu
Registration of Contractor, Annual Turnover, Similar Work experience, GST Registration, Income Tax Return, Site Visit Certificate
7 documents required · 7 mandatory
₹0
₹16.4 L
Yes
22 Jan 2026
10 Jul 2025
17 Jul 2025
10 Jul 2025
16 Jul 2025
10 Jul 2025
Amount
Clearing scrub Jungle and Surface dressing of the ground. The rate including hire charges of all machineries, removing of all rubbish from site, lead upto 50m, transportat charges and labour charges etc., complete complying with standard specification
Providing and constructing cast in situ hydraulic bored piles of 300mm / 450mm diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³ in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of mobalization of all necessary plants, equipment's like piling rigs, temporary casing of appropriate length for setting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method duly through all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc .,Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap).
For Building - 450mm dia pile
Supply and conducting Vertical load testing of piles in accordance with as per IS 2911 (Part- IV) - 2013 etc including supply and installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: After testing and unloading of the superimposed load splaced for the test, the pile should be chipped off 1metre below the ground level.
Supply Conducting Pile integrity tests (PIT) on the piles under each cluster by using a 6 lbs nylon tipped hand held hammer, glueing sensitive accelerometer on top of the pile by petro wax or petroleum jelly after making the pile head smooth and even by disc grinder, providing stage wise and final report along with relevant conclusions etc., as directed by Client / Engineer-in-charge. as per IS 2911 (Part- IV) - 2013 etc
Conducting High strain Dynamic load tests at 1M below existing ground level / pile cutoff level as per approved method shall be as per IS 2911 (Part- IV) - 2013 etc .Cost should include preparation of pile head, mobilization of all plant and equipments required for carry out the test as per the approved method.
Earth work excavation for all foundations in all type of soils and sub soils to the required depth for Footings, plinth / grade beams, etc,. by mechinaries including manual excavation for the following type of soil / rock as per detailed specification. As per SS 20B as hard rock requiring blasting inclusive baling out water wherever necessary and including refilling 0 to 2.0m depth consolidation depositing the surplus earth in places shown clearing and leveling the site with an initial lead of 10 metre and lifts as specified hereunder etc., complete in all respects complying with relevant standard specification and as directed by the departmental officers.
0 to 2m depth.
2 to 3m depth.
3 to 4m depth.
Construction of Embankment with approved Earth materials deposited at site from roadway cutting and excavation from drain and foundation of other structures, graded and compacted to meet requirement of table 300-1, 300-2 of MORTH, in layers not exceeding 250 mm loose thickness, spreading, breaking clods, removal of roots and other organic materials to the required line, grade and cross-section including watering, spreading by Dozer, grading by motor grader and consolidation by vibratory road roller with desired field density not less than 95% of maximum dry density ,including all lead,lift, loading, unloading, all labour, hire charges of all machineries, Transportation, etc., complete in accordance with MORTH technical specification clause No. 305 and with all other incidental charges and as per the direction of the Engineer-In-Charge of work.
Supplying and Filling with M - sand in foundation and others sub structures for 100mm thick and well watered, rammed and consolidated by power compacter. The rate includes the cost of M sand, compacting with mechanical compactors, labour charges for leveling, loading & Unloading and Transportation charges etc., complete and as per the standard specification.
Plain Cement Concrete 1:4:8 (One Cement, Four sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive of giving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an intervel of 12"to a depth of 8" in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc.,
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.9 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
For Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
For column footing plinth beam bed blocks templates staircase, steps piers, raft beam, raft slab etc.
for plane surfaces such as rectangular or square rcc columns, sunshades, top and bottom slab of rcc boxing, etc.
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical walls etc.
Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Raft, Grade beam, Shear wall, RCC walls, Lift walls, Plinth beams, Column, footings, Grade slab, Roof slab & beam, Curved slab, beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box binders basement retaining wall, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. Rate to include all leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, curing etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer in charge
For Foundation and Basement
For Ground floor
For First floor
Supplying, fabricating and fixing in position of steel Fe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete cover blocks to maintain the cover as required. The rate including cost of all materials, bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks and GI binding wires etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supply and constructing Fly ash Brick masonry in Cement Mortar 1:5 (One cement and Five M sand) in foundations, basement and superstructure using Fly ash Bricks of size 230x110x75mm etc. Rate to include all materials, labour charges, wastages for working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.
For Ground floor
For First floor
For Terrace floor
Supply and constructing Flyash Brick partition wall 115mm thick in Cement Mortar 1:3 (one cement and three M sand) 11.50 CM thick using using Fly ash Bricks of size 230x110x75mm including both side plastering with CM 1:5 12mm thick and using hoop iron reinforcement if found necessary and hoop iron shall be supplied to the department at free of cost etc., complete as directed by the Engineer in- charge.
For Ground floor
For First floor
Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc..with Cement Mortar 1:3 (1 of cement : 3 of fine P.sand) according to the specification. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Plastering of 12 mm thick for Internal walls with cement mortar 1:5 (1 of cement : 5 of fine P.sand) according to specifications. Rate shall include for providing GI mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Plastering 15 mm thick for external surfaces with cement mortar 1:5 ratio (1 of cement : 5 of fine P.sand) including water proofing compound of “CICO No.1 or equivalent“ as per Manufacturer's Specification with sponge finish (washed sand finish) all complete as per specification and as directed. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Supplying and painting of 2 coats of weather proof exterior emulsion with high sheen, anti algal properties over one coat wall exterior primer of approved quality and shade etc., complete.Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Supply and painting of two coats of Acrylic emulsion paint of approved shade and colour over one coat of DCP Primer including one coat of Acrylic Wall Putty with DCP Primer. Rate including all brush, roller, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.(Internal surface)
Flooring with Joint free double charged vitrified tiles of approved quality, colour and design joint free of size 600 x 600 x 8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.
Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Providing Ceramic tiles of size 305 x 305 x 6mm flooring approved make and quality with plain/colour with base mortor in CM 1:3, 10mm thick and pointing with white cement by adding suitable colour pigments including finishing, jointing and polishing with neat finish etc., complete. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.
Supplying and laying of Top of roof with Solar refelective tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as per the direction of the Engineer-In-Charge.
Paving the floor with kota stone slab of size 600 x 600 of 18 / 20mm (un-polished) in all floors laid in of cement mortor 1:3 (one cement three sand), 20mm thick and pointed with colour cement neatly including polishing with polishing stone and oxalic acid etc., so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges etc. The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard specification.
Supply and laying with best quality the following materials of Machine Polished granite slab of 18 mm thick (Fine Polished Steel Grey Granite Slab) including cutting and edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Supply and laying with best quality the following materials of Machine Polished granite slab for wash basin counter top of 18 mm thick (Stell Grey) including cutting for wash basin and edge polishing to be set in CM 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge - Flamed Steel Grey Granite
Supply and Laying skirting 100 mm high with vitrified floor tiles confirming to IS 13006/EN 176 Group B1a with techical specification of approved make , set in C.M 1:3 (1 of Cement : 3 of manufactured sand) 12 mm thick and pointing the joints with white cementt compound and matching corner tile beading. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, chasing of wall for flushing the tile inline with wall surface, preparation of surface, ncessary haccking in RCC surface, cutting of tiles to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.
Providing 100 mm high skirting with best quality approved granite slab of thickness not less than 18 mm, machine cut and leather finish set in cement mortar at all levels and all as per drawing. Rate shall include for preparation of surface, with tin-oxide / high gloss factory polish. Rate also to include filleting/ chamfering of the edges along with partial recessing of the skirting into masonry / gypsum wall.
Supply and applying water proofing treatment on Retaining walls external surface at Basement, UG Sump and STP raft sides etc. using cement admixed with water proofing compound in the following order . i) Making ' V ' grooves at the construction joints of size 20 x 20 mm and filling the "V" Groove with CICO No. 3 Quick Setting Waterproofing Compound admixed with cement ii) Supply and Fixing of 50 long 18 mm dia GI nozzles in the hole of about half the depth of member size along construction joints, and honey comb areas at a spacing not more than 1m c/c.iii) Supply and Applying injection grouting through the nozzles grouting pumps with a minimum pressure of 2 kg/sqcm with cement slurry admixed with CICO Non shrink Polymeric Water Proof Grouting Compound or approved equivalent at the rate of 2% by weight of cement. iv) Sealing & cutting of nozzles and leveling the surface using integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1by weight.v)Supply and applying one coat of TAPECRETE Acrylic Polymer Modified Cementitious Slurry Coat over well prepared surface as a Primer and applying CICO CORCHEM 206 - I Polyurethane Based Elastomeric Coating to the thickness of 1.5 mm over TAPECRETE slurry coat applied surface. vi) Lay protective plaster layer with 20 mm thick Cement Mortar 1:4 (1 cement: 4 coarse sand) admixed with Normal setting integral Waterproofing compound CICO NO.1 at the rate of 2% by weight of cement over the third coat of brush topping.
Supply and applying water proofing treatment on Toilet sunken areas using cement admixed with water proofing compound in the following order i)Making V groove over the construction joint, beam and slab joint and filling the groove with CICO Quick setting material (CICO NO 3) admixed with cement ii) Supply and Fixing of 50 long 18 mm dia GI nozzles in the hole of about half the depth of member size along construction joints, and honey comb areas at a spacing not more than 1m c/c. iii) Supply and Applying injection grouting through the nozzles grouting pumps with a minimum pressure of 2 kg/sqcm with cement slurry admixed with CICO Non shrink Polymeric Water Proof Grouting Compound or approved equivalent at the rate of 2% by weight of cement. iv) Sealing & cutting of the nozzles and level the surface using integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1by weight. v)Supplying, mixing, applying two coats not less than 2 mm thick of TAPECRETE- Acrylic polymer Waterproof Coating, over the treated RCC slab surface of bottom and sides of toilet sunken slab as per manufacturer's specifications and as directed. vi) Supplying and laying final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No.1 or approved equivalent at the rate specified by the manufacturer over coated surface
Supply and laying water proofing treatment for internal walls of over head tanks bottom of over head tanks covering the following order and consisting of following operations. i)Supply and Fixing 75 mm long 18 mm dia GI nozzles in the hole of about half the depth of member size in grid pattern at a spacing not more than 1.0 meter c/c while casting the bottom slab and along construction joints at a spacing not more than 1.0 meter c/c along the construction joints. ii) Supply and Applying injection grouting through the nozzles grouting pumps with a minimum pressure of 2 kg/sqcm with cement slurry admixed with CICO Non shrink Polymeric Water Proof Grouting Compound or approved equivalent at the rate of 2% by weight of cement. iii) Sealing off the nozzles and level the surface using integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1by weight. iv)The concrete slab shall be thoroughly cleaned to remove debris and dust, and application of two coats not less than 2 mm thick of TAPECRETE - RTU Polymer Based Elastomeric Waterproof Coating over well prepared surface
Making through holes in Plain or Reinforced Cement Concrete with Diamond Core Drilling System by using BOSCH power tools of following diameter in 150mm thick toilet floor slab
100mm dia 150mm thick
200mm dia 150mm thick
Supply and grouting the gaps around the pipes at any dia should be filed in order to provide a proper bond and the same to be aligned by the respective agency. Clean the entire surface and remove the loose particles from the core area. Minimum of 10mm all around gap to be provided between the pipe and the core Provide shuttering below the core apply one coat of CICO LATEX over the area and fill up the hole with CICO GROUT - GP Polymer Based Non-Shrink Grout and finish the surface smoothly.
Construction of Granular sub-base providing laying, spreading and compacting of Close graded Material conforming to Grading V of Table 400-1 of MORTH clause 401 ,mixing in a Wet Mix Plant of 200 tonne capacity at OMC, carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory roller 8-10 tonne to achieve the desired density of 98% including protection of edges of GSB layer, cost of all materials, labour, hire charges of machinery, lighting, guarding, barricading, maintenance of diversion road, loading & unloading, all lead and lift etc., to achieve minimum CBR value of 30%(Compacted Thickness) in accordance with MORT&H technical specification clause No. 401 and with all other incidental charges and as per the direction of the Engineer-In-Charge of work.
Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) -150mm compacted thickness by providing,laying,paving and compacting of aggregate gradtion satisfying table 400-13 of MORTH and satisfying the physical parameters as per MORTH table 400-12, mixing in wet mix plant 200 tonne capacity at OMC, carriage of mixed material to work site and laid in pavers to the required line and grade as per the drawing and compacted with vibrator rollers 8-10 tonnee to achieve the desired density 98% of maximum dry density. The rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision
Providing and laying to required line and grade as per the drawing interlockingcement concrete blocks of M 50 grade 100 mm thick laid over the sand cushion . The size and the shape of the concrete blocks had to be approved before sourcing / manufacturing the same. The aggregate used for the manufacture of the blocks ahsll be sound and free from soft apiecces . The proportion of thcoarse aggregate in the mix is typically 40 percent and the fine aggregate shall be 60% The size of the coarse aggregate should lie between 6mm and 12mm and the gradation should be in the recommended range for cement concrete mixes in general. The sand cushion 80mm thickness shall satisfy the following gradation table-1.The gaps between the two blocks shal be filled with relatively finer sand than the bedding sand of gradation as per Table 2 . The paver blocks shall be compacted using a light tandem roller or plate compactor till the required grade and line is achieved. The rate shall include laying of the bedding sand levelling , laying of paver blocks , filling of the filling sand and compaction
Supplying and filling the sunken slab area by BRICK-BATCOBA by adding CICO NO:1 or approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- Acrylic Polymer Based Waterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturer's specification after entire completion of laying pipes, sanitary fittings etc. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge. i) Including applying two coats not less than 2 mm thick of TAPECRETE- Acrylic Polymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No.1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturer's specifications and as directed.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Glass handrail for railling Supply & fixing for SS 50mm X 1.5mm Thick Top pipe, 5mm+1.52PVB+5mm clear Laminated Toughened glass, 50mm SS Bush, Pipe To Glass Holder, Holes, Installation, All SS will be polished to a matt finish All SS Grade 304,
Providing of Factory made prelaminated FPVC (Foamed Polyvinyl Chloride) Door frame of the size 105x40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre joined with 6 Nos. of 50mm long screw. The door frame shall be fixed to the wall by using 80mm long screws through the frame with the help of PVC fasteners of 3 no's to be provided for each vertical member,GIstiffners of ("U" channel of size 29x9x1mm, 150mm long) -3 no's at hinge point, Frame reinforcement of("U" GI channel of size 46x22x.06mm),Bottom tie rod of ("U" GI channel size of 15x15x1mm) etc. complete as per manufacturers specification for finished item of work. The door frame should be got approved from the Executive Engineer before use on work.
Providing of 35mm thick Factory made Prelaminated ABS (AcrolynitrileButadyne Styrene) Door shutter moulded in different designs, consisting of all round Frame made out of water proof solid foam PVC bar of size 20x32mm, reinforced by 32x 32mm - 2 nos. for vertical made out of LVL (Laminated Veneer Lumber), core material of 32 mm thick high density craft paper honey comb board, sandwiched on both sides with prelaminated ABS sheet thickness of 1.5mm . PVC edge banding of size 0.45mm on the vertical sides. Hardware made out of steel coated butterfly hinges-3 nos for each shutter, 'D' SS pull handle 200 mm on both sides and SS tower bolt on one side with ISI make complete for finished item of work, complete complying with the standard specification.and lifts, transportation charges, loading, unloading, scaffolding, staging, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.Rate including all materials, labour charges, wastages, necessary lead
Window :Supplying and fixing UPVC (Un-Plasticized PolyvinylChloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm125GSMand 100% corrosion free, the profiles are multichambered sections with wall thick of 2mm. The EPDMrubber (black colour) covered with over all the edges offrame and shutter the shutter will be provided withEspag multi power point locks and also it operates ashandle. The corners and joints should be welded andcleaned. Radiations free pin headed plain or browncolour glass 4mm thick should be provided to theshutter and it should not allow leakage of water evenat most ranging storms and should have key lockableaction, security protective hinges, strong lockingsystems and as per size for arresting noise and energyloss. The connecting mechanism between sash andouter frame that enables opening of the window. Thewindow should be fixed to the wall with 100% packingwith screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work
Ventilator Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Fluted Glass Divider for Tables in reading Area - Installation of 10mm thick , flutted glass all around with rounded edges on top fixed as per design. The divider size is .75x.3m ht (As per Architect Drawing
Rolling Shutter Geared Operation Supplying and fixing rolling shutters of approved make, made of required size M.S. laths of size 80 x 1.20 mm interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation to the suitable size and shape as per drawing etc complete including the cost of providing and fixing necessary 27.5 cm long good quality wire springs grade No.2 and M.S. top cover of 1.20 mm thick for rolling shutters. The rate shall be inclusive of one coat of red oxide primer and two coats of synthetic enamel paint of approved quality and colour.Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, installation charges, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.
Providing and fixing welded M.S. grills to the window openings, along the details as per drawing with necessary screws, bolts and fixed with necessary M.S. lugs embedded in masonry with C.C 1:2:4 and finishing the surface neatly. Rate shall welding and consumables, etc, complete, as directed. Design of grills and the size of members to be used shall be got approval before put into use and as directed by Engineer-in-charge
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. ( The make quality and colour of paint should be got approved by the executive Engineer before use on works.)
Providing and fixing of Mangalore tiles for size 282 X 428mm and 10mm thickness over the purlins. The tiles shall be laid from the eaves towards the ridge properly interlocked according to the design of the tile. The tile shall be laid either directly over the reepers or over an undercover. A suitable arrangement shall be made to secure the ends of lower most course of tiles to the roof structure for preventing the tiles from being blown up by wind. Alteast the bottom most layer of tiles, and preferably more number of layers above it, shall be tied to the reepers or other roof elements by means of galvanized wire. The tiles at the eaves shall also be protected against lifting by means of a galvanized steel flat of size 40 x 3 mm fixed to the roof. Where Mangalore tiles are laid as such over reepers, or over ceiling tiles, interlocking of tiles shall be ensured.
PART-A SANITARYWARES & CP FITTINGS
Supply and fixing in position white European Water Closet (floor mounted) of approved make with low level concealed flushing tank 10 litre capacity of best quality and approved make with 100mm P or S trap with double flapped rigid PVC seat cover with CP brass hinges etc. complete complying with standard specification and as directed by the Departmental officers (The EWC should be got approved by the Executive Engineer before use on works.(M-0647 - P.NO-97)
Supplying and fixing of Oval Shape Hand Wash Basin of size 560 x 450mm, including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and as directed by the Department officers. (The Wash basin should be got approved by the Executive Engineer before use on works.
Supplying and fixing of White Glazed Porcelain Oval Shape Special Type Urinal of size 382 x 398 x 601mm. Including fixing the urinal in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and as directed by the Department officers. (The urinal should be got approved by the Executive Engineer before use on works.
Supplying and fixing SS sink of size 1200 x 550 x 180mm, including fixing with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and as directed by the Department officers. (The SS Sink should be got approved by the Executive Engineer before use on works.
Supplying and fixing approved make of CP Two Way Bib Cock with Health Faucet (wall hook one metre long flexible tube) including cutting and making good the walls wherever required etc.complete, complying with standard specification and as directed by the Department officers. The quality and make of health faucet should be got approved by Executive Engineer before use on work.
Supplying & fixing approved make, 15 mm dia C.P of angle valve stop cock, conforming to I.S. Specifications & quality including cost of shellac, thread etc., complying with standard specifications & including cutting & threading wherever necessary. (Taps should be got apprioved by the Engineer - In- charge before use on work.)
Supplying & fixing approved make, 15 mm dia C.P of Pillar cock, conforming to I.S. Specifications & quality including cost of shellac, thread etc., complying with standard specifications & including cutting & threading wherever necessary. (Taps should be got apprioved by the Engineer - In- charge before use on work.)
Supplying & fixing approved make, 15 mm dia SS of swan neck tap, conforming to I.S. Specifications & quality including cost of shellac, thread etc., complying with standard specifications & including cutting & threading wherever necessary. (Taps should be got apprioved by the Engineer - In- charge before use on work.)
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) .
Supplying & fixing approved make, Coat Hook, conforming to I.S. Specifications & quality including cost of shellac, thread etc., complying with standard specifications & including cutting & threading wherever necessary. (Taps should be got apprioved by the Engineer - In- charge before use on work.)
Supplying & fixing approved make, Toilet Paper Holder, conforming to I.S. Specifications & quality including cost of shellac, thread etc., complying with standard specifications & including cutting & threading wherever necessary. (Taps should be got apprioved by the Engineer - In- charge before use on work.)
Supplying and fixing Brass Chromium Plated soap tray of size 150x100 mm. The rate including cost of soap tray, teak wood plug & CP screws etc., complying with standard specification and as directed by the Department officers.
Supplying and fixing Chromium Plated Towel Dispenser. The rate including cost of towel dispenser, teak wood plug & CP screws etc., complying with standard specification and as directed by the Department officers.
Supplying & fixing in position 15 mm dia brass/ C.P / SS screw down tape (Heavy duty) of approved make conforming to I.S. Specifications & quality including cost of shellac, thread etc., complying with standard specifications & including cutting & threading wherever necessary. (Taps should be got apprioved by the Engineer - In- charge before use on work.)
Supplying & fixing approved make, CP waste coupling, conforming to I.S. Specifications & quality including cost of shellac, thread etc., complying with standard specifications & including cutting & threading wherever necessary. (Should be got apprioved by the Engineer - In- charge before use on work.)
Supplying & fixing approved make, CP Bottle trap 32mm dia, conforming to I.S. Specifications & quality including cost of shellac, thread etc., complying with standard specifications & including cutting & threading wherever necessary. (Should be got apprioved by the Engineer - In- charge before use on work.)
Supplying & fixing approved make, CP/brass waste coupling with dome grating 32mm dia, conforming to I.S. Specifications & quality including cost of shellac, thread etc., complying with standard specifications & including cutting & threading wherever necessary. (Should be got apprioved by the Engineer - In- charge before use on work.)
PART-B INTERNAL & EXTERNAL DRAINAGE
Supplying & fixing in position PVC Nahini / Floor trap of size 100x75mm including stainless steel gratings of approved brand & quality, fixed over a bed of brick jelly lime concrete 1:2:5 ( One part of lime, two parts of sand & five parts of 40 mm size brick jelly ) & finished with cement mortar 1:3 ( One cement & three M sand ) including dismantling masonry works wherever found necessary & making good the damaged portions to the original condition & giving connections to the cast iron pipes etc., complete, complying with standard specification. (The PVC Nahini / Floor trap should be got approved by the Executive Engineer before use on works ).
Floor trap-100 mm Inlet & 75 mm Outlet
P' trap-100 mm Inlet & 100 mm Outlet
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below Stilt level .(Internal, External & Rain water system)
40mm dia pvc pipe - 10kg / sq.cm.
50mm dia pvc pipe - 6kg / sq.cm.
75mm dia pvc pipe - 6kg / sq.cm.
110mm dia pvc pipe - 6kg / sq.cm.
160mm dia pvc pipe - 6kg / sq.cm.
200mm dia pvc pipe - 6kg / sq.cm.
Supplying & fixing in position 150 X 100 mm square mouth 'P' or 'S' trap pvc Gully trap with cast iron double gratings of size 150 X 150 mm with C.I / SFRC air tight cover with frames of size 300 X 300 mm at bottom & top respectively with necessary earth work excavation, laid over a bed of brick jelly cement concrete 1:3:6, 150 mm thick using 20 mm size broken brick jelly including necessary brick work & plastering, &including dismantling masonry wherever necessary & redoing the damaged portions to the original condition & by using cement concrete 1:3:6 using 20 mm stone jelly for fixing the Gully trap & giving connections to the stone ware sewer line etc., complete, complying with standard specification. (The stone ware gully trap should be got approved by the Executive Engineer before use on works ).
450mm x 450mm internal size & 600mm upto 1000mm deep
600mm x 600mm internal size & 600mm upto 1000mm deep
900mm x 900mm internal size & 1000mm upto 1500mm deep
900mm x 1200mm internal size & 1500mm upto 2100mm deep
PART-C INTERNAL & EXTERNAL WATER SUPPLY SYSTEM
Supplying, laying and jointing CPVC pipes of approved quality and best variety conforming to ISS and with ISI mark of the following size including cutting, threading and fixing CPVC specials but excluding cost of such specials and fixing to wall with necessary teak wood plugs, GI clamps and screws, making good the dismantled portions to original condition with necesscary brick work and plastering wherever necessary scaffolding charges above ground level upto 4 m height.
20mm dia CPVC pipe Ratio - 11
25mm dia CPVC pipe Ratio - 11
32mm dia CPVC pipe Ratio - 11
40mm dia CPVC pipe Ratio - 11
50mm dia CPVC pipe Ratio - 11
Supplying, laying and jointing UPVC SCH-80 pipes of approved quality and best variety conforming to ISS and with ISI mark of the following size including cutting, threading and fixing UPVC specials but excluding cost of such specials and fixing to wall with necessary teak wood plugs, GI clamps and screws, making good the dismantled portions to original condition with necesscary brick work and plastering wherever necessary scaffolding charges above ground level upto 4 m height.
20 mm dia UPVC pipe Schedule-80
25mm dia UPVC pipe Schedule-80
32mm dia UPVC pipe Schedule-80
40mm dia UPVC pipe Schedule-80
50mm dia UPVC pipe Schedule-80
65mm dia UPVC pipe Schedule-80
80mm dia UPVC pipe Schedule-80
100mm dia UPVC pipe Schedule-80
Supplying & fixing in position first quality & approved variety of Brass/cast iron body nickel plated with stainless steel Ball Valves / Butterfly Valves / non-return valves / Y-strainer (Heavy type ) with I.S.I. Mark of the following size including cost of Shellac, thread etc.,including labour for cutting & threading of Pipes etc., complete complying with standard specifications for both internal & external water supply arrangements.
20mm dia Ball Valve
25mm dia Ball Valve
32mm dia Ball Valve
40mm dia Ball Valve
50mm dia Ball Valve
65mm dia Butterfly Valve
80mm dia Butterfly Valve
100mm dia Butterfly Valve
50mm dia Non return Valve
65mm dia Non return Valve
50mm dia Y- Strainer
65mm dia Y- Strainer
supplying and fixing SFRC manhole cover with frame of size 600mm x 600 mm clear size for UG Sump & Over Head Water Tank, conforming to I.S. Specifications & quality, complying with standard specifications & including cutting & threading wherever necessary. (Should be got apprioved by the Engineer - In- charge before use on work.)
600mm x 600mm clear size SFRC manhole cover with frame
Providing and keeping in stores, shifting to the place of installation, fixing of 1mtr length, 6mm Thickness UPVC SCHEDULE - 80 Puddle flanges for UG Sump & Over Head Water Tank, conforming to I.S. Specifications & quality, complying with standard specifications & including cutting & threading wherever necessary. (Should be got apprioved by the Engineer - In- charge before use on work.)
25mm UPVC schedule - 80 Puddle Flange
32mm UPVC schedule - 80 Puddle Flange
40mm UPVC schedule - 80 Puddle Flange
50mm UPVC schedule - 80 Puddle Flange
65mm UPVC schedule - 80 Puddle Flange
80mm UPVC schedule - 80 Puddle Flange
100mm UPVC schedule - 80 Puddle Flange
Supply, erection and testing & commisioning of 2HP submersible pumpset in the to suit 20000 LPH @ 25M, max. total head of 30M (3 pumps (2 working + 1 Standby) each pump capacity is 10000 LPH, fitted with bronze impellers and having delivery size of 65mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts,GI nipple, 65mm dia uPVC SCH 80 / HDPE hose of required length etc completed and as directed by the officer incharge. (RAW TANK TO DOMESITC OHT 1&2)
Supply, erection and testing & commisioning of approved make Booster system (capacity of system is 7.0 Cu.M/ hour at 20 meters head) comprising 2 pumps 1 working + 1 standby (each Pumpset 7.0 Cu.M/ hour at 20 meters head) with 1 No. of 328 litres capacity pressure tank, switch, guage, control panel etc. conducting trail run, testing, commissioning maintaining the system for the period of one year, rate include all Electrical panel work connected to existing Electrical cable arrangement etc. complete. For Domestic water purpose (At terrace level - BELOW / NEXT TO OH TANK)
Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (1000 litres) (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact.
Supply, installation, testing and commissioning of water filtration plant (5000 LPH), which contains Pressure Sand filter, carbon filter and chlorination system with complying as per IS standard with specifications & including pumps, plumbing, electrical works wherever necessary with all accessories as required. (Should be got apprioved by the Engineer - In- charge before use on work.) The system shall be provide with Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact.
Drilling of 12" dia vertical borewell so as to have a finished size of 6" dia borewell in boulder area to any required depth as decided by the TWAD Board Officers including Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractor's rig tools, fuel, labourers etc
300mm (TWAD ,Unique code : (WD-W0840): 14f, P.No: 202
150mm / 165mm (TWAD ,Unique code : (WD-W0834) 14a, P.No: 201
Reaming from 200mm dia pilot bore to 350mm dia bore as direct by the Engineer incharge up to 80mtr depth ending below ground level
Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 2010 P.No: 06
200mm dia CS (WD-W0030)
200mm dia RS (WD-W0032)
150mm dia RS (WD-W0029)
Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers.
200mm dia CS (WD-W0831)
200mm dia RS (WD-W0831)
150mm dia RS (WD-W0830)
Supplying and filling with river pebbles in annular space between bore and PVC pipe up to hard rock.
Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by 'V' notch method.
Supply ,erection and testing & commisioning of 3HP submersible pumpset in the to suit 200mm borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts,GI nipple, 50mm dia HDPE hose of required length etc completed and as directed by the officer incharge.
ELECTRICAL WORKS
LT PANELS
Supply, Installation, Testing and Commissioning all metal floor mounted meter board incorporated with the following. The cost of the foundation channels shall also be including in the rate. The Cost shall also includes unloading and positioning.3Nos.250Amps TP cutouts with 200Amps neutral link propoersly fixed on the sheet steel with necessary accessories with 200Amps 4P Aluminium Busbar. The Phase busbar shall be 50x6mm and the neutral busbass shall be 50x6.The Board shall be provided with 2Rus of 25x6mm Aluminium busbars of earthing.Space for fixing 14Nos of direct operated three phase energy meter with necessory accessories.14Sets of 1Nos. 32A TP cutout with neutral link properly fixed on the sheet steel.14Sets of interconnection between the coutout,MCB and the Meter shall be done with 16Sq.mm.Cu PVC insultated strandard copper conductor wires with crimped type lugs / sockets, etc.RYB indicating Lamps of LED Clustered type and Control toggles switch per each phase shall be provided for the Main EB cut-out chamber door. CRCA sheet Thickness : 14SWG for door and Frames 16SWG for others. Foundation Channel - 3mm thick Cable Gland - 14SWG Painting: Powder Coated RAL 7032 and Black Color for the foundation channel. (Rate as per quotation)
Supply, Installation, Testing and Commissioning all metal floor mounted meter board incorporated with the following. The cost of the foundation channels shall also be including in the rate. The Cost shall also includes unloading and positioning.3Nos.250Amps TP cutouts with 200Amps neutral link propoersly fixed on the sheet steel with necessary accessories with 200Amps 4P Aluminium Busbar. The Phase busbar shall be 50x6mm and the neutral busbass shall be 50x6.The Board shall be provided with 2Rus of 25x6mm Aluminium busbars of earthing.Space for fixing 14Nos of direct operated three phase energy meter with necessory accessories.8Sets of 1Nos. 32A TP cutout with neutral link properly fixed on the sheet steel.6Sets of 1Nos. 200A TP cutout with neutral link properly fixed on the sheet steel.8Sets of interconnection between the coutout,MCB and the Meter shall be done with 16Sq.mm.Cu PVC insultated strandard copper conductor wires and 6Sets of interconnection between the coutout,MCB and the Meter shall be done with 50Sq.mm.Cu.PVC with insultated strandard copper conductor wires crimped type lugs / sockets, etc.RYB indicating Lamps of LED Clustered type and Control toggles switch per each phase shall be provided for the Main EB cut-out chamber door. CRCA sheet Thickness : 14SWG for door and Frames 16SWG for others. Foundation Channel - 3mm thick Cable Gland - 14SWG Painting: Powder Coated RAL 7032 and Black Color for the foundation channel. (Rate as per quotation)
Supplying, erecting, connecting and commissioning 200Amps 4P ATS in M S enclosure in an angle iron frame, cable adoptor boxes,interconnections, etc., for EB and DB Changeover for Common service.
Supplying,erecting, connecting and commissioning of FLOOR MOUNTED CUBICLE TYPE MAIN POWER/LIGHTING PANEL with necssary foundation channels, etc., The cost shall also including unloading, positioning,etc., The Board shall be incorporated with the following:- INCOMER:200AMPS TP+N MCCB - 1No. OUTGOING: 63AMPS TP+N MCCB …5Nos. 32AMPS TP+N MCCB …3Nos BUSBARS : ALUMINUM RATING : 200 AMPS The Phase Bus bar shall be of 50 x 12mm. and the Neutral bar shall be 50 x 6 mm. The Earth Bus bar shall be 2 Runs of 25 x 6mm. There shall be One set of Metering Compartment incorporated with the following:- i) 3 Nos Tape wound CTs of ratio 200 /5A and Class 1. 0 for Metering and burden 15 VA. ii) 1 No. Class 1.0, 96 Sq.mm. Digital Muilt function meter ( V, A, f, Kwhr ). iii) RYB Indicating Lamps of LED Clustered type and Control MCBs shall be provided. CABLE ENTRY : TOP / BOTTOM (Rate as per quotation)
Supply, Erection, Testing and Commissioning of 58.5KVA Diesel Generator set with AMF control panel, comprising of Water cooled CPCB developing @ 1500 RPM and Alternator, complete with type approved canopy and all accessories. with the following technical specification: *Industries most reliable engines, proven over decades. *Low emission, High efficiency. *Compact, robust and rugged design. *Engine Dry type air cleaner *Exhaust Silencer (Residential type) Hospital Grade. *Expansion bellow *Lube oil cooler Lube oil filter (“Spin-on” type) *Fuel Filter (“Spin-on” type) *In line mono block fuel injection pump with Electronic Governor and fuel feed pump. *Dynamically balanced Flywheel with starter ring *Electronic Governor :Governing class G2(as per ISO 8528 part V) *SAE 1 flywheel housing and flywheel suitable for SAE 14 disc coupling for close coupling of single bearing alternator.
*Exhaust gas turbocharger 24 Volt electric starter motor 24 Volt, 18 amps. Battery charging alternator *Engine instrument control panel consisting of: Engine safety module EMS (KG934) with built in On/Off Bush button. ALTERNATOR *Exhaust gas turbocharger 24 Volt electric starter motor 24 Volt, 18 amps. Battery charging alternator *Engine instrument control panel consisting of: Engine safety module EMS (KG934) with built in On/Off Bush button. ALTERNATOR 58.5KVA, Three phase 415V, 0.8 pf 4 wires 50 hz at 1500 RPM brushless alternator. The voltage regulation will be 2 phase sensing +/¬ 1 %. The alternators shall be of Class H insulation, enclosure IP 23 and are designed built and tested to IS 4722 or any other equivalent Indian or international standards. Control Panel: 58.5 KVA DG Set Std Control Panel Consisting of EMS KG934 unit consisting Volt, Amps, RPM, Hz, LLOP, HWT, Low fuel level, over Speed alarm, Over Load alarm, Load imbalance safety alarm, etc. Fuel Tank: 300 Letters Capacity inbuilt Fuel Consumption: 100% = 37.6 Litres/hr.75% = 27.6Litres / hr.50% = 19.8Litrs/hr. Battery: 24V DC, 130AH Supply of AMF Control Panel Suitable for 320 KVA DG set for EB Services with byepass arrangement. (Make: Kirlosker, Koel or equvalent) including Suitable Foundation and Transportation charges.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and fixing of 7 segment 6 way 63A TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no 63A. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no.63A 4 pole ELCB / RCD (totally 8 ways in one segment) 3Nos 63A 2pole MCB(3x 6 ways in each segment) and 24nos.6A to 32A SP MCBseperate provision for MCB / Isolators ( totally 24 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following on wall with earth connection only.
VERTICAL THREE PHASE MCB DISTRIBUTION BOARD WITH MCB : Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 3 nos. 32A 3P MCB, 15 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End
Supply and laying of following XLPE armoured HT / LTUG cable in a Earth / Trench / Tray with suitable cable tie tag etc as required.
Supply and laying of 31/2 core x 120 Sq.mm PVC armoured LTUG cable in tray or wall with MS Clamp.saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Clamping of 3 1/2C x 50 sq.mm. PVC armoured LTUG aluminium cable on post or on wall with MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Clamping of 3 1/2C x 25 sq.mm. PVC armoured LTUG aluminium cable on post or on wall with MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Clamping of 4C x 16 sq.mm. PVC armoured LTUG aluminium cable on post or on wall with MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Clamping of 4C x 10 sq.mm. PVC armoured LTUG aluminium cable on post or on wall with MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Laying of 4C x 10 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.(Outside)
Supply and fixing of double compression brass cable gland for following Aluminium conductor XLPE insulated armoured cable of 1100 V grade with earth connection.
Supply and fixing of brass cable gland for 3 1/2 C x 120Sq.mm PVC LTUG armoured cable with earth connection
Supply and fixing of brass cable gland for 3 1/2 C x 50 Sq.mm PVC LTUG armoured cable with earth connection
Supply and fixing of brass cable gland for 3 1/2 C x 25 Sq.mm PVC LTUG armoured cable with earth connection
Supply and fixing of brass cable gland suitable for 4C x 16 PVC armoured LTUG cable with earth connection.
Supply and fixing of brass cable gland suitable for 4C x 10 PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of the following size PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (copper sockets for copper cables and Alu. Sockets for alum. HT / LT Cable)
Supply and providing cable end termination of 3 1/2 Core x 120 Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete.
Supply and providing cable end termination of 3 1/2 Core x 50 Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete.
Supply and providing cable end termination of 3 1/2 Core x 25Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete.
Supply and providing cable end termination of 4 C x 16sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete.
Supply and providing cable end termination of 4 Cx10 sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete.
Supply and Run of 2 of 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable 32mm PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Supply and Run of 2 of 4 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable 32mm PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Supply and Run of 2 of 2.5 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable 32mm PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.(Primary Point)
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe on wall and ceiling with continuous earth wire connection of 2.5 sq mm copper wire with painting of suitable colour.
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Light point / fan point (for electronic regulator) ( 6 points / Coil) Higher End
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box on wall with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Light point / fan point (for electronic regulator) ( 6 points / Coil) Higher End.Secondary
Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End
Supply and fixing of 1no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.Scope cover wall cutting, grouting,flushing and making good on the wall. Higher End.
Supply and fixing of 2no.6A two module 5 pin socket , 2 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.Scope cover wall cutting, grouting,flushing and making good on the wall. Higher End.
Supply and fixing of 1no.6A/16A two module 5 pin socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.Scope cover wall cutting, grouting,flushing and making good Cocealed the wall. Higher End.
Supply and fixing of 2nos.6A/16A two module 5 pin socket , 2 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.Scope cover wall cutting, grouting,flushing and making good Cocealed the wall. Higher End.
Supply andfixing of25A Flush type Wall Socket 25ADPMCB complete set for ACP lugin flush with wall with earthconnection (For AC Plug)
Indoor / Outdoor Light fittings
supply and fixing of 65 mm dia. (2 -1/2") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 60W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour .(Rate as per quotation)
Supply and fixing of 28 W LED tube light fitting with cool day light made out of CRCA powder coated body, poly methyl meth acrylate (PMMA) diffuser, glare free light, Suitable for recessed / surface mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories etc., complete.( Make: Crompton)
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18")
Supply and fixing of 300mm(12")sweep (Heavy duty) AC Exhaust fan complete with necessary wall opening and making good of the wall and wiring to the near by point with 1.5 sqmm FRLS PVC insulated copper wires including necessary accessories and hardware's as required.
Supply and fixing of louvers shutters arrangements for 300mm (12") sweep (light duty) AC exhaust fan
EARTHING SYSTEM
Supply and installation maintenance free GI Earthing System comprising of 50mm dia and 2 mtr. long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs. of carbon based environment friendly backfill compound and suitable clamp.
Supply, Installation, Testing and Commissioning of earthing station consisting of 600 x 600 x 3 mm. thick, copper Plate earth electrode, back filling with alternate layer of charcoal, salt, brick masonry work for chamber 450 x 450 mm. heavy duty CI cover, watering pipe, funnel and earthing conductor as per IS:3043 specification. All civil works required such as excavation in all types of soils, rocks, PCC Earthing Chamber foundation, reinstatement and making good the surface to match original, removal of surplus earth etc. are included.
Coil earth to street light poles with No.8 SWG GI wire of 11.5 metres of length in which 10 metres of total length compressed in to a coil of one meter length (75mm to 100mm dia) connected suitable with hexagonal earth bolt of size 8mm in to 25mm welded on the pole at one end with a coil position fixed on the earth.
Supply, fabrication, of GI /Copper earth flat of following size in provided trench, clamping in wall, ceiling, with suitable Clamps/ saddles, connecting the joints through bracing / welding covering with termination in the earth pits, Panels, Distribution boards and equipments with bitumen paint including accessories wooden plugs, screws, fastener etc., all inclusive
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection
Supply and Run of 1 of No.8 SWG GI wire in suitable PVC rigid pipe on wall / floor / ground for earth connection
The cable rack shall have runners rugs of suitable size, horizontal elbow, vertical elbow 90 Deg. Up vertical elbow 90 Deg. Down, re-deep, coupler plates, materials. The cable racks shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fastners, welding, anchor bolts, nuts etc. The rack shall have suitable cable clamping arrangements etc.' Cable Tray /ladder should be powder quoted as match with ceiling colour as per PWD requirements. The rate shall inclusive of necessary Wedge anchors theaded rods,nuts & bolts, making clamp for rcc roof fix / perlin/Truss, cable tray clamps etc, (8 mm threaded rod supports shall be provided at not more than 2 mtr center to center and as per site requirement )
300X50mm Perforated Tray
Supply, Installation, Testing and commissioning of 32 channel 8 SATA NVR 1no with 8TB Hard Disk Drive 2nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected, Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output HDMI1 / VGA1 outputs provided HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire /ship / temperature / temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. (Make : Hikvision / Dahua / Sony).
Supply of 8MP, Internet Protocol fixed BULLET /Dome CAMERA with Indoor and Out door following specification: ●1/2.5" Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection) ● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied ●On-board Storage - Built-in micro SD/SDHC/SDXC card slot, up to 128 GB, ● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W ● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. (Make: Dahua/Panasonic)
Supply, Installation, Testing and Commissioning of 55" smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS pannel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANR h) True colour generator i) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remote p) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung).
Supply and fixing of outdoor 4 x 6 PVC box with 102mm x 77mm x 102mm with all fixing accessories. (Rate as per quotation enclosed)
Supply and Laying of CAT 6 armoured cable in 50mm dia HDPE pipe below the ground complete with all necessary accessories etc.. (Between ethernet switch to camera and radio modem) i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal) IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM ii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant. Fire Rating: PVC : IEC 60332-1. iii. Conductor - Bare Copper Wire iv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm.
Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges.
Supply and fixing of POE 24 port switch 10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line.
Supply and fixing of POE 8 port switch 10/ 100 / 1000 Base -T / 2 x 1000 Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line.
Supplying and concealing modular type RJ socket with top pin with suitable with concealed type manufacturer's GI metal back box and modular socket in flush with wall mounted on poly carbonate front plate with socket mounting metal parts, for making good of the concealed portion with suitable colour.
Supply and Fixing of Rack with Accessories -Higher end 4 U Rack with LNS unit and fan extra for the above rack.
Supply and Fixing of Rack with Accessories -Higher end 9 U Rack with LNS unit and fan extra for the above rack.
Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up with stand
Supply, Erection of 6m Length pole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges.
PA System
Supply, Installation,Testing & commisioning of 480 watts P.A Mixer Amplifier with the output power of 1350 watts maximum, 500watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 watts RMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of 2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db.(Make:Ahuja SSA 10000 /Bosch or its equivalent)
Supply, fixing & Testing of 10" gooseneck with suitable base incorporates separate bush switches for momentary and dynamic microphone with 600ohm impedence and has 2.5mv/pa sensitivity and frequency response ranging from 50-15000hz with multi tone chime model.(Make:-ACM66 Ahuja/bosch/its equivalent)
Supply and run of 2core 1.5 Sqmm armoured speaker cable with 25mm PVC pipes on wall, tray and ceiling etc. complete.
Supply & Installation of custom built M.S Powder coated wall mounting Audio rack with Lock & key for housing of Amplifier & player/Recorder conforms to EIA-310, IEC-60297 and able to withstand the load of 40kg with welded construction made up of CRCA steel with suitable height, width and depth.
Safety Accessories
Supply of 2m x 1m Rubber 3mm thick Mat suitable for LT installation confirming to IS
Supply of First Aid Box complete with all First Aid Medicines
Supply of Shock Treatment Chart fixed in glass frame
Supply of 1 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle
Supply of Hand Gloves 11KVGrade
Supply of Danger Board as required by the Electrical Authorities
Supply of Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms
Earth Discharge Rod
Lightning Rod
Supply of Early Streamer Emission Air Terminal (ESEAT). Model: L The ESEAT has corrosion resistant stainless chrome body made up of AISI 316 grade of height 0.50 metres capable of working in hazardous atmosphere. The Air terminal is non-radioactive and requires no special licensing. The unit is fully autonomous (no battery, no external power supply is required), collects energy from the ambient electric field. The ESEAT model has been tested in a high voltage laboratory in accordance with NFC 17 102 in order to measure the average gain in triggering. The average gain in triggering time (ΔTs) obtained during the lab test for the offered model is 60 μs. The ESEAT works on negative as well as positively polarized discharges. ESEAT has been tested for such discharges in Central Power Research Institute (CPRI). A dedicated tester is available to test the healthiness of the ESEAT on request (Page No. 37, Point No. 3 of Clause 8.6 of the Revised NFC 17-102 version 2011 ). ESEAT Model : L - Radius of protection : 86 Metres Level of protection considered for the Project-II level
MOUNTING STRUCTURE Supply of Standard / Special Mounting Structure of height 4.5 mts. pipe, and 300 x 300 x 8mm MS plate, 3 mts. 48mm OD class C GI outer pipe,1.8 mtr, 38mm OD inner pipe, for roof mounting on concrete base and with FRP adapter
TEST LINK Supply of Test Link Box for each Down conductor in order to disconnect the earth termination system to enable measurement of resistance
SURGE PROTECTION Supply and installation Cabinet Type Class 1 and 2 Combined Model SPD to arrest surges and overvoltages in the power line due to lightning switching action etc. they must be installed in the incoming MCC panel / DB of the respective building in parallel to the power circuit. Model: PSV4-12.5/400TT (3 phase power network)
Supply and Fixing of 1 x 12W LED Bollard Light fitting with Integrated Driverg of with necessary weather proof junction boxes, GI brackets, interconnections, etc.,
Supply and Fixing of 1 x 10W Bulk Head type light fitting of with necessary weather proof junction boxes, GI brackets, interconnections, etc.,
Supply and Fixing of 1 x 20W Surface Down light fitting(IP65) of with necessary weather proof junction boxes, GI brackets, interconnections, etc.,
Lightning Rod
250 kVA, 11 kV/433 V ONAN Outdoor Transformer.
P K SUBRAMANIAN CONSTRUCTION (BID ID -1402800)
SRK ASSOCIATESS (BID ID -1403883)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid