Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55,500Admitted-Finance | ₹55,500 | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ARIF ZAIDI L1 |
|---|---|---|---|---|
| 1.00 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
(a) 20 mm nominal outer dia. Pipes. | 10 | One Running Metre | 300 ₹3,000 |
| 2.00 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
(a) 25 mm nominal outer dia. Pipes. | 5 | One Running Metre | 350 ₹1,750 |
| 3.00 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | 50 | One Kilogram | 130 ₹6,500 |
| 4.00 | Centering and shuttering including strutting, propping etc. and removal of form for :
(a) Suspended floors, roofs, landings, balconies and access platform | 5 | One Square Metre | 900 ₹4,500 |
| 5.00 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
(a) Cold twisted bars | 50 | One Kilogram | 100 ₹5,000 |
| 6.00 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | 500 | One Litre | 10 ₹5,000 |
| 7.00 | Providing and laying S&S C.I. standard specials such as tees, bends, collars, tapers, caps etc. (Heavy class) :
(a) Up to 300 mm dia. | 1 | One Quintal | 6,000 ₹6,000 |
| 8.00 | Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 :
(a) 100 mm dia. Pipe | 3 | One Running Metre | 1,200 ₹3,600 |
| 9.00 | providing and laying footvalve 100 mm all complete as per direction of engineer in charge | 1 | Each | 5,000 ₹5,000 |
| 10.00 | Providng and fixing non return valve 80 mm of Zuloto and equivalent make all complete as per direction of engineer in charge. | 2 | Each | 9,000 ₹18,000 |
Tender Value
₹59,783
EMD Value
₹1,196
Closing Date
5 Mar 2026, 6:00 pmClosed
SDE (C)
SDE (C), BSNL Civil Sub Division, VIVEK VIHAR, New Delhi-110095
A/R and M/O to staff quarters at Vivek Vihar Delhi-95 SH- Replacement of damaged Non Return Valve and priming tank in pump room and other related civil works
2026_BSNL_268473_1
25/BSNL/BCD-1/2025-26
Open Tender
Civil Works
15 days
Vivek Vihar Delhi
Please refer Tender documents.
4 documents required · 4 mandatory
₹177
AO (Cash)
₹1,196
9 Mar 2026
24 Feb 2026
7 Mar 2026
24 Feb 2026
5 Mar 2026
24 Feb 2026
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall (a) 20 mm nominal outer dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall (a) 25 mm nominal outer dia. Pipes.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Centering and shuttering including strutting, propping etc. and removal of form for : (a) Suspended floors, roofs, landings, balconies and access platform
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (a) Cold twisted bars
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and laying S&S C.I. standard specials such as tees, bends, collars, tapers, caps etc. (Heavy class) : (a) Up to 300 mm dia.
Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : (a) 100 mm dia. Pipe
providing and laying footvalve 100 mm all complete as per direction of engineer in charge
Providng and fixing non return valve 80 mm of Zuloto and equivalent make all complete as per direction of engineer in charge.
Credit for old iron
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.78 MB
BOQ_312458.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid