E E Gadchiroli Irrigation Div. Gadchiroli
Executive Engineer, Gadchiroli Irrigation division Gadchiroli, Sonapur Complex Area Gadchirioli. Maharashtra
Supplying, Erecting, Testing and Commissioning of Surge Protection System at Reguntha Lift Irrigation Scheme Ta. Sironcha, Dist. Gadchiroli.
2026_CEWRN_1293546_1
E Tender Notice No 1/2026-27
Open Tender
Civil Works - Canal
Percentage
365 days
Regunta Lift Irrigation Scheam Ta sironcha
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
₹3.0 L
5 May 2026
8 Apr 2026
27 Apr 2026
8 Apr 2026
24 Apr 2026
8 Apr 2026
8 Apr 2026 - 16 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Item No. 1: - Providing, Supplying, Erecting & Commissioning of Surge Protection System comprising of Bladder Vessel with minimum Volume of 15 m3, Pressure rating minimum 06 Bar with shell - SA 516 Gr. 70, Elliptic Cap - SA 516 Gr.70, Coating inside & Outside - Thickness 110 micron along with sand blasting SA 2.5 with Butyl Bladder in vertical position. Vessel Connecting Pipe Size 400 mm diameter, M.S. 400 mm Isolation Valve (Confirming to DIN 3202 F4/IS 14846/EN 558:2008), Pre charge Pressure of 02 mt, Load cell arrangement, necessary piping, Flanges, Fasteners, Civil work etc. complete including all lead & lifts.
(Location of Bladder Vessel as per Surge analysis report) | - | No. | - | - |
| - | Item No. 2: - Providing, Supplying, Erecting & Commissioning of 3 - Stage Surge Suppression Air Valve on Delivery Pipe (Confirming to AWWA C 512) of Diameter 80 mm Pressure rating minimum 06 Bar with all cutting, welding of pipe for Tee (T) connection, Isolation Valve (Butterfly valve-Confirming to (IS 13095:1991) - 80 mm Diameter for maintenance purpose and necessary accessories as per the site requirement. Valve should have a simple and robust construction offering high reliability and free operation with high intake capacity. It should be Non Slam Surge Suppression high flow Combination 3 - Stage air valve, including all lead & lifts.
(Location of Valves as per Surge analysis report) | - | No. | - | - |
| - | Item No. 3 :- Providing, Supplying, Erecting & Commissioning of 3-Stage Surge Suppression Air Valve on Rising Main (Confirming to AWWA C 512) of Diameter 150 mm Pressure rating minimum 06 Bar on rising main with all cutting, welding of pipe for Tee (T) connection, Isolation Valve (Butterfly valve-Confirming to (IS 13095:1991) - 150 mm Diameter for maintenance purpose and necessary accessories as per the site requirement. Valve should have a simple and robust construction offering high reliability and free operation with high intake capacity. It should be Non Slam Surge Suppression high flow Combination 3-Stage air valve, including all lead & lifts.(Location of Valves as per Surge analysis report) | - | No. | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
DTP_AntiSurge_Reguntha.pdf
Tender Documents • 2.21 MB
BOQ_2222879.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .