Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹62.2 L
EMD Value
₹1.2 L
Closing Date
6 Jan 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2025_PWDJK_299162_1
e-NIT No.EDJ166 of 2025-2026 Dated 26-12-2025
Open Tender
Electrical Works
Percentage
Jammu
please refer to NIT
2 documents required · 2 mandatory
₹600
Executive Engineer PWD RandB Electric Div Jammu
₹1.2 L
5 Feb 2026
26 Dec 2025
7 Jan 2026
27 Dec 2025
6 Jan 2026
27 Dec 2025
Supplying, Installation, Testing and Commissioning of 98" Flat UHD size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required.
Supply Installation Testing Commissioning of UHD LED 65" resolution 3840x2160, Brightness 500 Nits,Contrast Ratio 3000:1, Viewing angle 178/178,Response Time 8ms,display Colour 16.7m,Built in 15 watt speaker , Input : RGB, DVI-D, Display Port 1.2, HDMI 2.0, Stereo Mini jack, DVI , HDMI, Usb 2.0 with 03 years warranty
SITC of Retractable Touch Monitor Chairman Unit: It should have 17.3" HD, aluminium alloy embedded with toughened glass, It should support 1920 x 1080 HD display, .,It should have decentralized design to avoid system server required. Chairman unit should be able to push content to all screens just by pressing one button and shall control all display elevation, It should have the facility to create and program 3 identities Chairman, Secretary, Delegates , It should have Loop-in Loop-out connection on network cable, it shall support and control 42 display simultaneously., It should have automatic power supply mode and should gets on when it comes out and should shut down when goes in cover, It should have Multi-point balanced lifting control system with double silent sliding rail structure for smooth & uniform lifting., It should have Digital intelligent synchronous positioning recognition processing technology giving accurate positioning, unified speed and free lifting of the lifting system., The body thickness should be less than 70mm, It should be easy to transport with panel thickness of 3mm thickness; It should be equipped with computer switch shortcut button to support manual switching , It should have USB for data supporting HDD, mouse & keyboard ; It should support adjustable tilting with range of 120°. Panel up, down, pause, with independent control button, It should have support manual control, Loop-in Loop -Out Cat 6 for content , RS-232 control, Software control, Remote control, It should have automatic identification when single source is used and it should have manual switching when two sources are connected. It should go into power saving mode when no signal.
Supply Installation Testing and Commissioning of Digital Chairman Unit with fixed microphone with flexible stem can be easily adjusted to suit the user- Short (250mm) or more as per instruction of Engineer-in-charge ,Built-in loudspeaker with volume control,Built-in volume control for headphones, Possible-to-speak indication,Request-to-speak indication,GSM immunity, The flush mounted discussion device with micropone is the perfect solution for conference rooms where table space is key. The flexible stem allow the participant to adust the microphone to the most comfortable position.Possible Functions:-Possible-to-speak indication:- A white possible-to-speak indicator above the microphone button indicates when the microphone can be activated.Request-to-speak indication:- A green request-to-speak indicator above the microphone button and in the head of the microphone indicate when a request-to-speak has been added to the waiting list. The indicators flash green when the request-to-speak is first in the waiting list. Short or long microphone with flexible stem:- The fixed microphone with flexible stem can be easily adjusted to suit the user. For maximum comfort, a short 310 mmm (12.2 in or more) . Built-in loudspeaker with volume control:- To ensure for optimum intelligibility, the loudspeaker volume of all discussion devices is centrally controlled from the control unit. Face-to face meeting feeling:- An authentic face-to face meeting feeling is achieved by allowing the loudspeaker and microphone to be on at the same time.
GSM immunity:- Immunity to mobile phone interference ensure clear, uninterrupted discussion.Controls and Indicators:- 1. Microphone button plus 5 or more buttons for Volume control of built-in loudspeaker, headphone jack etc. 2. Color-coded LED indicator above microphone button for showing the following states: microphone on, request-to-speak, and possible-to-speak. 3. Light-ring indicator in head of microphone. 4. Concealed initialization button at base of device for reassigning the network address. Connections 1. 1 x 6-or more pole circular female connector with cable locking recess - or 2 x RJ 45 port supporting for loop-through connection of Discussion Devices. 2. 1 x 1 m cable with a 6-pole circular male connector with cable lock or RJ45 cable Technical specifications:-Power consumption (W):- 1.50 W/ Frequency response (-3 dB) (Hz):- 30 Hz- 20000 Hz/ Total harmonic distortion + noise (%):-1%/ Minimum signal-to-noise ratio (dBA):- 80 dBA
Maximum number of flush discussion devices supported per trunk :- 35/ Acoustic Polar Pattern:- Cardioid/ Frequency response (-3 dB) (Hz) (microphone):- 125 Hz - 15000 Hz/ Nominal Acoustic input level (dB SPL) (microphone):- 85 dB SPL / Microphone stem length (mm) :-310mm/ Mounting type :- flush-mounted / Connector type:- 6-pin connector male cable length (m):- 2 m/ Environmental:-Operating temperature (ºC - 35 ºC)/ Storage temperature (ºC):- - 40 ºC - 70 ºc/ Operating relative humidity, non-condensing (%):- 5% - 98%/ Air pressure (hPa):- 600 hPa - 1,100 hPa
Supply Installation Testing and Commissioning of Digital Delegate Unit with fixed microphone with flexible stem can be easily adjusted to suit the user-Short (250 mm or more) as per instruction of Engineer-in-charge ,Built-in loudspeaker with volume control,Built-in volume control for headphones. The flush mounted discussion device with short micropone is the perfect solution for conference rooms where table space is key. The flexible stem allow the participant to adust the microphone to the most comfortable position. Possible Functions:- Possible-to-speak indication:- A white possible-to-speak indicator above the microphone button indicates when the microphone can be activated. Request-to-speak indication:- A green request-to-speak indicator above the microphone button and in the head of the microphone indicate when a request-to-speak has been added to the waiting list. The indicators flash green when the request-to-speak is first in the waiting list. Short or long microphone with flexible stem:- The fixed microphone with flexible stem can be easily adjusted to suit the user. For maximum comfort, a short 310 mmm (12.2 in) or long 480 mm (18.9 in) microphone stem is available. Built-in loudspeaker with volume control:- To ensure for optimum intelligibility, the loudspeaker volume of all discussion devices is centrally controlled from the control unit. Face-to face meeting feeling:- An authentic face-to face meeting feeling is achieved by allowing the loudspeaker and microphone to be on at the same time.
GSM immunity:- Immunity to mobile phone interference ensure clear, uninterrupted discussion. Controls and Indicators:- 1. Microphone button plus 5 or more buttons for Volume control of built-in loudspeaker, headphone jack etc. 2. Color-coded LED indicator above microphone button for showing the following states: microphone on, request-to-speak, and possible-to-speak. 3. Light-ring indicator in head of microphone. 4. Concealed initialization button at base of device for reassigning the network address. Connections 1. 1 x 6- or more pole circular female connector with cable locking recess - or 2 x RJ 45 port supporting for loop-through connection of Discussion Devices. 2. 1 x 1 m cable with a 6 or more - pole circular male connector with cable lock or RJ 45 Cable Technical specifications:- Power consumption (W):- 1.50 W Frequency response (-3 dB) (Hz):- 30 Hz- 20000 Hz/ Total harmonic distortion + noise (%):-1% / Minimum signal-to-noise ratio (dBA):- > 80dBA.
Maximum number of flush discussion devices supported per trunk :- 35 / Acoustic - Polar Pattern:- Cardioid/ Frequency response (-3 dB) (Hz) (microphone):- 125 Hz - 15000 Hz /Nominal Acoustic input level (dB SPL) (microphone):- 85 dB SPL //Microphone stem length (mm) :-250mm or more /Mounting type :- flush-mounted / Connector type:- 6-pin connector male /cable length (m):- 2 m /Environmental:- Operating temperature (ºC - 35 ºC) / Storage temperature (ºC):- - 40 ºC - 70 ºC / Operating relative humidity, non-condensing (%):- 5% - 98% /Air pressure (hPa):- 600 hPa - 1,100 hPa
Supply Installation Testing and Commissioning of Digital conference system controller with connection of up to 80 Discussion Devices from day one( provide expansion unit accordingly from day one) and expandable upto 220 Delegate Units ,Built-in MP3 recorder with internal memory and USB recording,Internal /External( Digital Acoustic Feedback Suppression) (DAFS) for ensuring superior speech intelligibility, support for automatic HD camera control,Web browser control for configuration, Built-in monitor loudspeaker,built-in loudspeaker and headphone socket allows for:live monitoring of a meeting , indicators for showing-Open microphone, Mains power on/off,Plus/minus buttons for setting the volume range, RJ45 Ethernet,USB recording LED indicator.
SITC of HDMI Extender ( Supports 50 Mtr. and above).
SITC of Distribution Amplifier 1 HDMI In 4 HDMI Out.
SITC of Switcher 4 HDMI In 1HDMI Out Audio De Embedder.
SITC of PTZ Camera ; USB based : Yes; Zoom : Minimum 20X Optical Zoom; Iris: f=5.57~110mm ; F1.6 ~ F3.5;Viewing Angle:3.3° (tele) –54.7° Wide ;Sensor:1 /2.8inch or better CMOS sensor; Pixels:2.07 Mega Pixel ; Video Format: SDI Video Formats: 1080P60/50/30/25/59.94/29.97 ; 1080I60/50/59.94. 720P / 50/ 30 / 25 /59.94/29.97; Minimum illiumination:0.5 Lux ; DNR:2D & 3D DNR; White Balance :Auto/Manual/One push 3000K / 3500K / 4000K / 4500K / 5000K / 5500K / 6000K / 6500K /7000K; Electronic Shutter : Auto/Manual; Focus : Should be Auto/Manual/One Push; BLC:ON/Off; WDR : Off/Dynamic level adjustment; Video Adjustment: Brightness, Color, Saturation, Contrast, Sharpness, B/W mode, Gamma curve; SNR : >55 dB; Interface:: USB 3.0 x1, DVi/HDMI x1, , LAN x1, RS232 x1; Video Compression Format:H.265/H.264 ; Control Protocol: VISCA/PELCO-D/Pelco-P; Baud Rate : 11520 / 9600 / 4800 / 2400 ; LAN Port :Yes; Network Protocol: RTSP/RTMP/ ONVIF, GB/T28181; Pan Rotation:+ 170° Tilt Rotation :-30°~+90° ; Pan Control Speed: 0.1~100°/second ;Tilt Control Speed : 0.1~45°/second ;Preset Speed: Pan: 100°/second, Tilt 45°/second ;Preset Number:255 preset
SITC of Video Conferencing Endpoint: It should the facility to upgrade the unit from Point to Point into Multi Point supporting 1 +3, 1+5, & 1 + 8 conferencing sites.It should be compatible with standard SIP and H.323 private network conferencing,It should have open API to support third-party application development for easy customization. It should have infrared passthroughand should enable control of camera and codec with single remote control. It should support remote recording capabilities with a PC for conference recording. It should support USB flash drive recording; It should support simultaneous input and output of two different languages, allowing flexible mixing and encoding of dual-language audio. It should have packet loss resistance feature supporting FEC technology to address severe network packet loss, It should have Multimedia Framework Protocol : ITU-T H.323,IETF SIP ; Video Codec Protocol : H.261,H.263,H.263+ ,H.263++, H.264, H.264 High Profile,H.265; Audio Codec Protocol :G.711,G.722,G.722.1,G.722.1C,AAC-LD ,G.726,SILK ; Double Stream Protocol: ITU-T H.239,BFCP; It should support Other Communication Protocols : H.221,H.224, H.225,H.235, H.241,H.245, H.281,H.350, H.460,T.140, DTMF; Network transmission Protocols:TCP/IP,DHCP,SSH,HTTP,HTTPS with SSL/TLS,RTP, RTCP, RFC3261, RFC3264, RFC2190,RFC3407,RFC2833,RFC4585(RTP/AVPF), SNTPARP; Audio Feature:It should have Automatic echo cancellation (AEC), Automatic gain control (AGC), Automatic noise suppression (ANS); It should have Audio Input Interface:1×3.5mm input or more , 1 × Cannon plug microphone input or more, 1 x RJ45 input or more, 1x USB input or more, 1 × HDMI input or more; Audio Output Interface: 1 × 3.5mm output or more, 2 × HDMI Audio output or more, 1 x USB outputor more;
Video Input Interface : 2 x HDMI or more,1 x USB or more,1 x VIDEO( POE Touch); Video Output Interface: 2 X HDMI (3x HDMI Optional) or more; USB Interface :2 x USB 3.0 (USB flash disk supported, USB microphone etc.) or more; Network Interface : 2 × RJ45 or more: 10/1000 Base-T Touch/DMIC Interface 1 × Wireless or more: 802.11 b/g/n Wi-Fi (Optional); It should support Others : OLED display IP and registration number, AI tracking AI noise reduction, voice to text, wireless casting,4K dual-screen heterodyne display; It should come with Active Image Resolution supporting Minimum: 1Mbps for 4K at 30fps; dual 4K at 30fps on main and auxiliary streams with minimum 2 Mbps. It should support Minimum 512Kbps for 1080p at 60fps; 4K at 60fps and should support on minimum 2Mbps; Data Content Resolution:Input: It should support VGA (640x480),SVGA (800X600), XGA(1024X768), WXGA(1280X768) ,WXGA(1280X800), 1280X960, SXGA (1280X1024,1360X768,1366X768,1440X900,1600X900,720p(1280X720),1080p(1920X1080)3840X2160, Codec:800X600,1024X768,1280X1024,1280X720,1920X1080,3840X2160, Output: 800X600, 1024X768,1280X1024,1280X720,1920X1080,3840X2160, It should have Active Dual Stream with Dual 4K resolution at 30 frames per second to display content on one screen and video on another. Other Image Feature: It should have PIP (Picture in Picture), PBP(Picture by Picture), POP in case using a large single display; It should have Bandwidth IP: 64kbps~8Mbps; Power Supply : Operating voltage: DC 12V, Max. power consumption:54W.
Supply Installation Testing and Commissioning of Popup Box, Pop–Up Table Mount Multi–Connection Solution, Elegant in–table compact solution, CE qualified, 4 Fixed Inputs — 15–pin HD, HDMI, 3.5mm & Ethernet. PORTS - HDMI connector,,Ethernet RJ–45 connector, 15–pin HD connector, 3.5mm mini jack.
SITC of Digital signal processor :Should have Double Core chip having 456MHz or better ; Should have Microphone Inputs x 08 or more; Should have Microphone / Line outputs x 08 or more ; Should have Input processing’s with Preamp, Signal Generator, Expander, Compressor, 5-band parametric equalisation, Auto gain, AM auto mix function, AFC Adaptive Feedback Cancellation; Should have Output processing with Speaker management having 31-band graphic equaliser, delay, crossover, limiter, high and low channel filters; Should have Matrix Mixing of input and output signals, mixing component control or better; Should have Automatic Mixing Console ; Should have AFC Auto feedback elimination; Should have Auto Echo cancellation; Should have Auto Noise Cancellation module; Should have Automatic mixing console, Ducker, or better, Should have built-in USB as Microphone in and Audio out for Software based VC as well as for recording the conference and playing digital audio, Should have camera tracking for Look At Me / Speaker tracking, Should have minimum 8 GPIO ports free to configurable as required. ; Should have Central Control Command Cet Generator ; Should have Sampling rate of 48Khz or better,Frequency response of 20Hz – 20Khz + 0.2dB or better, Should have input gain amplification of -24~27dB,3dB,Level 1 with minimum 7 levels or better ; Should have background noise -90dBu or better ; Should have THD+N ≦0.004% @4dBu or better ; Should have Automatic power failure protection memory function; Should have per channel phantom power 48V module or better. ; Should have software which should be configurable PC and also through Mobile devices like Smart phones, Tablet etc.; Should have password facility to avoid misuse having separate password for the admin and separate for users; Should have facility to save the different setting done in a file upto 100 or more settings; Should have Ethernet Port RJ 45 x 1; Should have RS 232 x 1; Should have RS 485 x 1.
SITC of Wall mount Speaker: Power Tap: 10W/20W/40W/OFF-8ohm,Power at 8ohm, 60W;Peak Power: 80W,SPL@1M: 94±3db, Max SPL@1M: 112db, Frequency Response: 65-20KHz,Dispersion Angle: Vertical : 80° and Horizontal:100° (1KHz),Enclosure Material : PP Enclosure and 360-degree metal mounting bracket, Speaker 6.5” weatherproof woofer and 1” silk tweeter.
SITC of Amplifier: Power Output 240 W Max., 350W RMS at 10% THD, 330W RMS at 5% THD, Output Regulation 2 dB, no load to full load at 1kHz, Input Channels 7 X Mic. 0.65mV/4.7k Ohms , 2 X Aux 100mV/470k Ohms, Frequency Response 50-15,000Hz ±3dB, Signal to Noise Ratio 60dB , Tone Controls Bass ±10dB at 100Hz, Treble±10dB at 10KHz, Outputs Line: 200mV/600 Ohms, 1V/1k Ohms, Speaker Output 4 Ohms, 8 Ohms & 100V, Digital Player MP3 Player with USB, SD Card & Bluetooth, Power Supply AC: 220-240V 50/60Hz , DC: 12V, Power Consumption : AC : 250VA DC : 4A, Power Consumption AC : 250VA DC : 4A, Consist of USB Pen drive Port, SD Card Plug and Play, Compatible with Radio & Bluetooth, EQ & Recording, 5 Channels Microphone Inputs, 2 Channels Aux Inputs, 1 Channel Line Output. 100V Constant Voltage Output and 4Ω\ 8 Ω \16 Ω Resistance Output.
"Supply Installation Testing and Commisioning of wireless handheld Microphone with -32 preset channels, with compatible groups of eight (8) channels for simultaneous use14 hour battery life from two (2) AA alkaline batteries , Rugged metal transmitters with backlit LCD display and battery gaugeNumber of Channels: 32 Modulation: ± 40 kHz Diversity: True Antenna RF Sensitivity: <1.0 μV for 12 dB SINAD Image Rejection: > 55 dB Squelch: Tone Code plus Amplitude,Frequency Response: 80 Hz – 18 kHz ± 2 dB Balanced Output: 20 dBV (max @ 40 kHz deviation) Unbalanced Output: Adjustable 8 mV to 0.755V RMS Distortion: < 1.0%, 0.4% Signal-to-Noise Ratio: > 100 dB
Supply Installation testing and commissioning of 5 KVA/ 4 KW True Online , DSP Controlled online UPS with 1 phase AC input 50Hz and 1 phase AC output with 60 minutes backup on 12V SMF batteries Bank with Rack along with inter connecting battery cables and cable from UPS to Battery bank. The UPS should be with IGBT Based Rectifier and Inverter and with LCD/LED display for monitoring of its status along with inbuilt Galvonic Isolation Transformer. UPS should have following Features: UPS power factor : Input PF should be 0.99 AND output PF not less than 0.9 , Efficiency: up to 97% without Isolation ,Communication interface :RS232/USB port and optional SNMP compatibility for remote Monitoring , Audible Alarm : Mains Failure/Low battery /UPS Warning /Overload/Fault & Bypass Mode , THDI: not more than 5% , Noise Level less than 70db ,CERTIFICATIONS & Standard : ISO-9001-14001 Certified ,Compatibility with DG Genset , Built in Automatic & Maintenance Bypass Switch , Warranty : 2 Years on UPS as well as on Batteries, Battery Make : Exide /Amaron/Quanta/ Panasonic Make Preferred/Approved Brand : APC-Schneider /Emerson –Vertiv /Legrand-Numeric.
Desktop Computer/ Laptop Core i3/16 GB RAM/ 512 GB SSD/20" Screen
Supply installation testing Commsioning of 24 Uwith fully loaded including rack,pdu and all accessories required Standard rack to place all Av equipment
Supply Installation Testing & Commissioning of 3 Core Power Cable 1.5 sqmm.
Supply installation testing Commsioning of speaker cable core 2x1.5 sq mm with all accessories as required.
Supply , Installation , Testing & Commissioning of HDMI to HDMI cable 20 Mtr etc. as reqd.
Supply , Installation , Testing & Commissioning of HDMI to HDMI cable 1.5 Mtr etc. as reqd.
Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. 1 Run of cable
CAMC for Audio and Video system for Two year after Defect liability period of 1 year
Supplying, installation, testing and commissioning of 2.0/2.2 Ton Inverter type Split AC's (copper) Hot/ Cold (all weather) type of minimum capacity following Specification as detailed below. 1. Type:- Split (Indoor Unit & Outdoor Unit) 2. Cooling Capacity:- Not less than 6000 watts 3. Compressor type :- Twin Rotary type Compressor 4. Refrigerant:- Eco-friendly (Green Gas) (R-22/ R-32/ R-290/R-410A/R-600A) 5. Remote Control:- Yes 6. Swing:- Adjustable 7. Air flow adjustment:- Auto 8. Energy Efficiency i) ISEE Rating (Desired):- 05 Star Rating, Inverter type ii) BEE rated Energy Efficiency Ratio (EER):- Not less than 3.8 9. General features:- i) Filters:- Anti Bacteria/Dust filter etc. ii) Air Direction Control:- Air iii) Auto Restart:- Yes iv) Sleep Mode:- Yes
v) Timer:- Yes vi) Sound Level inside (in db):- Not more than 50 db & Sound lel outside (in db):- Not more than 56 db vii) inverter type split AC:- Yes viii) Power Supply/Consumption a) Power Supply (Volt/Phase/Hz.):- 230/Single/50 b) Power consumption (watts) with 100% loading:-Not more than 2000 watt c) Power consumption (watts) with 50% loading:- Not more than 900 watt d) Running Current (Amps):- Max 8.0 to - 9.0 Amps e) Operating Temperature (room) minimum:- 2 º C to 46 º C f) Maximum Outside (Ambient) Temperature:- Should be capable of operating at least upto 50 ºC Ambient Temperature 10. Compressor Warranty: 10 years 11. PCB Warranty: 5 year 12. Total System Warranty: 1 year Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required.
Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:- 2 Years from the date of installation.
Supplying & fixing of M.S Wall/Floor Stand duly powder coated for outdoor unit of Split AC
Supplying & fixing of drain pipe for indoor unit 1"
Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group-A
Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 x 10 sq. mm + 1 x 6 sq. mm earth wire
4 x 16 sq. mm + 2 x 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 1 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Bell push
Ding Dong Bell
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C"curve including connections, painting etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mm x 75mm)
4 Module (125mm x 75mm)
6 Module (200mm x 75mm)
8 Module (125mm x125mm)
Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.
12 way (Double door) (SPN type)
Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.
8 way (4+24), (Double door) (TPN type)
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.
Single pole 6/10/16/32 Amp
Single pole and neutral 32 Amp
Single pole and neutral 40 Amp
Single pole and neutral 63 Amp
Triple pole and neutral 40 Amp
Triple pole and neutral 63 Amp
Supplying & fixing of LED Batten Tube fitting 600mm size 10/11 watt Aluminium housing with 1000 Lumens and min lumens efficiency 100 lumens/watt P.F >.90
Supplying, installation, Testing & Commissioning of 18- 22 watt LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)
Supplying, installation, Testing & Commissioning of 36 watt Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required.
Ceiling fan 1200 mm sweep alongwith rod upto 1'-6" long (3 Star)
Exhaust fan 300 mm size (Metalic)
400 mm wall fan
Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable)
35 sq. mm 3.5 core
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.07 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.95 MB
BOQ_970450.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .