Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC 2 B KRISHNA NAGAR AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹14.3 L Quoted ₹14.5 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹15.3 L+₹74,299.40 (5.11%)Rejected-Finance | ₹15.3 L+₹74,299.40 (5.11%) | L2 | Rejected-Finance Being not lowest |
| 3 | L3₹17.4 L+₹2.9 L (19.9%)Rejected-Finance | ₹17.4 L+₹2.9 L (19.9%) | L3 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
2 Mar 2023, 6:00 pmClosed
Capt Arvind Kumar
GE (P) Dappar
Special Repair to worker canteen (Bldg No 109) at Mil Stn Dappar under GE (P) Dappar
2023_MES_579366_1
GE (P) DPR-45/2022-23
Open Tender
Civil Works
Works
180 days
GE (P) Dappar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (P) Dappar
₹45,000
Yes
9 Jul 2023
6 Feb 2023
4 Mar 2023
6 Feb 2023
2 Mar 2023
17 Feb 2023
6 Feb 2023 - 17 Feb 2023
Amount
B/R Portion
Raking out joints/ pointing to brick work or brick tiles, laid flat, in floors built in cement mortar, surface channels, roofs, etc complete all as specified and directed.
Flush pointing to brick tiles laid flat as in pavings/Roof in CM 1:3 complete all as specified and directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified nd directed by Engr-in-Charge.
M&L for PCC 1:2:4 using 12.5mm graded stone aggregates, steps; seismic and other similar bands, plinth courses, string courses, parapets and copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed and directed by Engr-in-Charge.
Demolition of cement concrete un-reinforced in ground floors and paving n.exc 15cm thickness complete all as specified.
M&L for 75 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate)
M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick with grey cement and no pigment, set, jointed and pointed in neat cement slurry in floors over 20mm thick screedbed in CM 1:6. complete all as specified and directed.
M&L 100 mm thick Cement concrete type D2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing.
M&L Sand filling 25mm thick under floors or in foundations including watering and consolidation complete all as specified & directed.
M & L machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and no pigmentas specified & as directed by Engr-in-Charge.
Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed
M&L for cement plastering 15mm thick in cemet mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for cement plastering 5mm thick in cement mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for cement plastering 15mm thick in two layers (10mm +5mm) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and fair complete all as specified and as directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
Supply only integral liquid water proofing compound complete all as specified and directed. Make : Pidilite/Sika
M&L applying 02 coats of OBD oil emulsion preparation of newely plaster surfaces @ 10 sq.m/litre/2 coats by using roller/brush to new surfaces , over a coat of putty thickness vary from 1 to 1.5 mm over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed.@ 10 sq.m/litre/2 coats by using roller/brush to old wall surfaces , over a coat of putty thickness vary from 1 to 1.5 mm over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer including complete removal of existing treatment complete all as specified and directed. Make of Wall Primer : Asian / Berger / Nerolac [Best Quality]. Make of OBD : Asian (TRACTOR) / Berger (BISON) / Nerolac (BEAUTY SMOOTH)
M&L for preparation of newely plaster surfaces of ceiling and applying three coats of white wash complete all as specified.
M & L for preparing existing treated surfaces on ceiling including cornices and applying two coat of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by Engineer-in-Charge.
M & L for preparation of new surfaces of external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc including cornices and applying two coat of cement base paint @ 5 sq.m/kg/1 coat by using following brands of cement based paint by roller complete all as specified & as directed by Engineer-in-Charge. Make of Cement Paint : Snowcem Plus (Snowcem Paints)
M&L 50 mm thick PCC 1:3:6 type B1 (using 20 mm graded stone aggregate) lincluding finishing the surface even and smooth without using extra cement, as in plith protection, complete all as specifed.
Demolition of brick work built in cement mortar incl all quoins, arches, pillars, etc complete all as specified and directed by Engr-in-Charge.
M&L Brick work with sub class 'B' burnt bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed by Engr-in-Charge.
M&L Brick work with sub class 'B' burnt bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 but except brick complete all as specified and directed by Engr-in-Charge.(serviceble Old bricks shall be reused after cleaning obtained from demolition).
Dismantling, floor, hearth or wall tiling including CM(bedding (but not backing), removing serviceable tiles to store & rubbish off the premises
Providing and Laying Premium (1st) quality digitally printed straight edge, punched, glazed ceramic rectangle tile in approved shade and finish with flexural strength greater than 16 N/mm2, scratch hardness on Moh’s Scale minimum 3 and crazing resistance of 2 cycles in coloured tiles 600 X 300 mm and 7 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified. Note : Dado should be flushed with the wall plastering. Make : Johnson (Digital HD Tiles) (Barstow DK/LT/HL for Toilets & Verona LT/HL for Kitchens) or equivalent from Kajaria/Somany as approved by AO
M & L for joint free non-Skid whilte ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge
M&L for Baroda Green marble, machine cut as in shelves/steps/cills/jambs/skirting/border and the like works and flooring etc, 15-16 mm thick including bull-nose the front length, set and jointed in cement slurry over & including screed of 15 mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type granite polishing complete all as specified. Note : Single piece should be used in steps/cills/jambs/shelves.
S&F in repair Sink Cock wall mounted with swinging spout and with wall flange, fency type chromium plated cast copper alloy screwed down, high pressure, screwed one ends for 15mm bore of iron pipe or for union and fixed in position complete all as specified and directed. Make : Jaquar (Continental Series)/ Hindware (Contessa Plus Series)/ Cera (Ocean Series)/ Prayag (Neptune Series)
S&F in repair stainless steel sink with drainage board, 1.00 mm thick, glossy finish, for kitchen with plugs washers and CP waste coupling/round strainer of 110mm dia and including cantilever cast iron brackets, connecting union, etc, overall size 915mm x460 with bowl size 410x 330 x 160 and making good disturbed portion in CM 1:3 or PCC 1:2:4 as directed. Make : Sink :- Nirali or Diamond or Neelkanth or Prayag
S&F in repair towel rod CP 60 cm long between flanges and including all accessories like brackets/screws etc as recommended by manufacturer and complete fixed in position complete all as specified.
S&F in repair cockroach trap gratings AISI-304 of size 150X150mm square in shape with 5mm border complete in all respect all as specified. Make : Prayag (FT-31M) or equivalent as approved
Taking up or down existing steel tubing and connections, 15mm bore complete all as directed and specified.
S&F 15mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as directed and specified.
Taking up or down existing steel tubing and connections, 20mm bore complete all as directed and specified.
S&F 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as directed and specified.
Supply Fixing in repairs 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified.
Supply Fixing in repairs 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified.
S & F in repairs 1000 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including disconnectiong of existing tank and removing to store.
S&F for MS Clamps, Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay) and similar small articles conforming to Fe-290 Gde-E-165 all as specified
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
S&F in repairs PVC(HDPE) SWR RWP, 150 mm bore, single socketed in any length with rubber ring joints using solvent as per maunfacture instruction, fixed to walls complete all as specified and directed by Engr-in-Charge. Make : Astral / Prince / Finolex
S & F in repairs 150 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S&F in repairs PVC(HDPE) SWR ,75 mm bore, single socketed in any length with rubber ring joints using solvent cement as per manufacture instruction, including all fitting elbow, tees, sockets, bends etc. laid in trenches & floors for connecting bottle traps & nahani trap complete all as specified.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
M&L cast iron nahani/floor/multi floor trap 100 mm dia including jointing with solvent cement in repair fixed in cement concrete (1:2:4) type B1complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed.
S&F Pressed steel frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, hold fast etc., complete all as specified, size 105 x 60mm and incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed.
S&F Pressed steel frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, hold fast etc., complete all as specified, size 125 x 60mm and incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed.
M&L cement concrete 1:2:4 type B-1, using 20mm graded stone aggregate as in holdfast blocks/ filling in chowkats complete all as specified and directed.
S&F factory made flush shutters 30 mm thick ply construction, BWP confirming to IS 2202, solid core construction, with block board core and plywood face panels, commercial type on both sides with 6mm thick lipping frame to match including supply and fixing following items : (a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm - 4 Nos per leaf (b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf (d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16 x 300mm - 1 No per leaf (e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 No per leaf
S&F 35mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR-91 Pt-1 section 8 clause 8.20(a), kiln seasoned and chemically pressure treated all as specified including stainless steel 304 Grade wire cloth (wire dia. 0.36mm) and the supply and fixing following items: a) Stainless steel (304 Grade) Finished Butt Hinge 150mm-4 Nos per leaf (b) Stainless steel (304 Grade) Finished Tower Bolt 200mm long-2 Nos per leaf (c) Stainless steel (304 Grade) Finished Handle 200mm- 2 Nos per leaf (d) Stainless steel (304 Grade) Finished door sttoper-1 Nos per leaf (e) 200mm long MS rat tail pattern springs incl roller and roller plate-1 Nos per leaf
S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate fixed complete all as specified and directed.
Providing and fixing factory made extruded aluminium casement windows with 15 micron powder coating doubled panelled and double shutters consisting of frame and mullion of 101.60X44.45X1.29 mm and shutters made of 63.5X31.75X1.29mm and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size with and including 5mm thick glass in front shutters and stainless steel wire gauge 0.36mm dia and 1.40 aperature in inner shutters complete fixed in all respect as specified including supply and fixing following items :- (a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm - 2 nos per leaf. (b) Powder Coated Aluminium Tower Bolt 150mm long - 2 nos per leaf. (c) Powder Coated Aluminium Handles 150 mm - 1 nos per leaf. Make (Aluminium Sections) : Jindal/Valco/Galco/Hindalco or equivalent as approved by AO
Providing and fixing factory made extruded aluminium ventilators with 15 micron powder coating of frame of 63.5 X 38.10 X 1.29 mm including 5mm thick frosted glass in lower 55% portion of shutters and stainless steel wire gauge 0.36mm dia and 1.40 aperture in upper 45% portion of shutter and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size with and complete fixed in all respect as specified. Make (Aluminium Sections) : Jindal/Valco/Galco/Hindalco or equivalent as approved by AO
S&F factory made aluminium 15 micron powder coated grill, opening size 101.6 X 63.5 mm (4"X2½") and of approx weight @ 1.345 Kg/sq.m complete fixed in position in windows in all respect as specified
M & L for preparing new wood & wood based surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. Make : Asian Paints/Berger/Nerolac
Demolition of reinfoced cement concrete of any description and in any position not otherwise specifically demolition provided for(reinfocement should be cut as required to facilitate demolition) complete all as specified and directed by Engr-in-Charge.
M&L reinforced cement concrete (nominal mix) type B1 1:2:4 (using 20 mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by Engr-in-Charge
M&L Mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landig and similar work; not exceeding 200mm thick (horizontal or sloping)
Dismantling of boarding of any type/size as in CB/wardrobes or fixed in any position in hardware (if any) etc complete all as specified.
M&L plain fillets as in 2nd class hard wood square rectangular in section wrought secured with screws sectional area exc 6 but n. exc 13 Sqcm. Complete all as specified and directed.
M&L Prelaminated particle board,18/19 mm thcik both side interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work
S&F Piano/continuous hinge of size 40 mm (when open) stainless steel complete all as specified.
S & F 150mm aluminium handles, cast type, anodised complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing for ISI Marked 150mm long aluminium, anodized, barrel tower bolts of extruded section complete all as specified and as directed by the Engineer-in-Charge
S&F 125mm Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws
S&F in repair harrison rails, 25mm dia mild steel, chromium plated with fixing brackets, stops, rollers etc, directed by Engr-in-Charge
Dismantling of Asbestos cement sheeting any gauge, thickness as in roof covering complete all as specified and as directed
S&F prepainted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall ,fixed with self tapping screws as specified.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet of 0.50 mm thick, rib having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engr-in-Charge. Note : Fixing of sheets will be done strictly according as per manufacurer's instructions. Make : Tata Bluescope or equivalent as approved by GE
Dismantling wrought iron or mild steel work of any description
M&L for ecavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil
S&F Plates Fe-410W(GdeE-250) Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) confirming to Fe-410 Gde 250 quality A including distance pieces, cleats etc
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment confirming to Fe-410 Gde 250 quality A including distance pieces, cleats etc
S&F Mild steel bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square not exc 30cm long of dia neck n exc 12mm
M&L for PCC in post and struss type B1 1:2:4 (20mm graded aggregate) all as specified and as directed
M&L for applying two coats of synthetic enamel paint steel surfaces of any description, over 10cm in width or girth,not otherwise described.
E/M Portion
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.
Taking out existing sub main wiring of any description and size including earth wire incld wooden battens/ conduits/quities from stone/brick masonry walls, roofs, floors, etc. all as directed by Engr-In- Charge.
M& L Point wiring complete with 1.5 sqmm (nominal area) PVC insulated PVC unsheathed multistranded copper condutor single core cable 1100 volts grade, FRLSH, ISI marked drawn through and including heavy duty non metalic PVC conduit, ISI marked, not less than 20 mm dia of thickness 1.8 mm concealed in wall, roof, etc, with all connected fittings including pressed steel terminal boxes suitable for mounting modular switches, sockets etc and including PVC insulated and unsheathed multistranded single core copper conductor cable of size 1.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings as specified and directed for the following:- Note:- Switches , sockets, ceiling rose, regulators etc shall be measured and paid separately. Quoted rate is deemed to be inclusive of cost of cutting chases in wall for incorporting PVC conduit and cost for making good to existing wall with CM 1:4 not exceeding 10 cm grith & painting same so as to match the existing wall.
(a) One light / fan / Bell point controlled by one switch
(b) One 5 pin socket outlet independent 5 Amps
(c) One socket outlet 5 Amps on the same board with other switches.
(d) One 6 pin 5/15 Amps socket outlet independent with 2.5 Sqmm size copper conductor cable and 1.5 sqmm copper cables as earth wire.
M&L Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable size of cable 2x6 sqmm (line conductor) & 1x6 sq mm (earth conductor). 1100 V grade drawing in & includingheavy duty non metalic PVC conduit, ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core copper conductor cable, green in colour as in earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed. Note : (i) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only. (ii). Suitable size cable lugs copper fabricated will be measured in the quoted rate only. (iii). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate.
All as per above but in existing PVC conduit with single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x4sqmm and 1 x 4 sqmm.
S&F Modular switch 1 way 6 A, 1 module type single pole 240 volts and complete all as specified and directed by the Engr-in-charge. Make : Hager Insysta/Legrand Asteor/Seimens/Schenider Zencelo.
S&F Modular switch 16Amps 2/3 pin combined 2 module 240 Volts complete all as specified and directed by the Engr-in-charge. Make : Hager Insysta/Legrand Asteor/Seimens/Schenider Zencelo.
S&F Modular socket 6Amps 2/3 pin combined 2 module 240 Volts complete all as specified and directed by the Engr-in-charge. Make : Hager Insysta/Legrand Asteor/Seimens/Schenider Zencelo
S&F Modular socket 6/16Amps 2/3 pin combined 2 module 240 Volts complete all as specified and directed by the Engr-in-charge. Make : Hager Insysta/Legrand Asteor/Seimens/Schenider Zencelo.
S&F Modular Fan step regulator, 120 watt 2 module 240 volts and complete all as specified and directed by the Engr-in-charge. Make : Hager Insysta/Legrand Asteor/Seimens/Schenider Zencelo.
S&F White cover plate with frame 2 module 240 volts complete all as specified and directed by the Engr-in-charge. Make : Hager Insysta/Legrand Asteor/Seimens/Schenider Zencelo
S&F White cover plate with frame 3 module 240 volts complete all as specified and directed by the Engr-in-charge. Make : Hager Insysta/Legrand Asteor/Seimens/Schenider Zencelo
S&F White cover plate with frame 4 module 240 volts and complete all as specified and directed by the Engr-in-charge. Make : Hager Insysta/Legrand Asteor/Seimens/Schenider Zencelo
S&F White cover plate with frame 8 module 240 volts andcomplete all as specified and directed by the Engr-in-charge. Make : Hager Insysta/Legrand Asteor/Seimens/Schenider Zencelo
S&F Modular Metal Box 2 module and complete all as specified and directed by the Engr-in-charge .
S&F Modular Metal Box 3 module and complete all as specified and directed by the Engr-in-charge .
S&F Modular Metal Box 4 module and complete all as specified and directed by the Engr-in-charge .
S&F Modular Metal Box 8 module and complete all as specified and directed by the Engr-in-charge .
Supply and fixing in replacenment Modular Angle holder Cat Pat NO 33958 of Anchor Equivalent/Havells/SSK with insulated body with back plate for LED lamps all as specified and directed by the Engr-in-charge .
Supply and fixing in replacement LED lamp 9watt, retrofit all as specified and directed by Engr-in-charge complete.Make Havells/Philips/CG
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
Supply and fixing in replacement ceiling rose bakelite, 63.5mm 3 terminals with base plate ISI marked, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement MCB SP 6 -32 Amps,10 KA,,'C' series 240 V ISI marked.complete all as specified and directed by Engr-in-Charge. Make: Legrand/ABB/Schenider
S&F Sheet metal enclosure MCB SPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V, 8 Way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. Make : Legrand/ABB/Schenider
S&F Sheet metal enclosure DB vertical TPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 415V, 4 Way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. Make : Legrand/ABB/Schenider
Supply and fixing in replacement thermal magnetic adjustable type MCCB 63 Amps,16 KA, 'C' series 415 V ISI marked.complete all as specified and directed by Engr-in-Charge. Make: Legrand/ABB/Schenider
Supply and fixing in replacement MCB SPN 32 Amps,10 KA 'c' series 240 V ISI marked.complete all as specified and directed by Engr-in-Charge. Make: Legrand/ABB/Schenider
Supply and fixing in replacement MCB SPN 40 Amps, 10 KA 'c' series 240 V ISI marked.complete all as specified and directed by Engr-in-Charge. MAke: Legrand/ABB/Schenider
M&L for Taking down ceiling fan and connected cables removing into safe place and Re-Fixing ceiling fan and connecting up including provision of cable from ceiling rose to fan complete all as specified and directed by Engr-in-Charge.
M& L Earthing complete by using GI wire as earthing lead and MS galvanized earth plate of size 60 cm x 60 cm x 6.3 mm as earth electrode surrounded by charcoal and salt, buried directly in ground vertically in pit of depth not less than 2.25 meter below the ground with top edge of the earth plate at a depth of less than 1.5 mtr below ground level surounded from all sides with mixture of charcoal dust and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron connected iron connected to main switch board or main control board all as shown in electrical plate No 3 of SSR 1991. Pt I and including necessary exc. and earth work. The rate also include testing, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC chambers in cement concrete (1:3:6) type CI 40 mm thick RCC(1:2:4) type B-1 cover and CI frame etc.complete all as specified and directed by Engr-in-Charge.
S&F LED building security light, pressure die cast aluminum housing, 15 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 6 mtr from ground with MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge of make Crompton Greaves cat part no - LSTS-15-CDL OR Equivalent in Philips/Wipro. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate.
Taking down existing unsv cable and Material & Laying XLPE UG insulated, armoured heavy duty electric cable in repair with aluminium conductor multi stranded, 1100 volts , 3.5 core 35 Sq mm .Make-Havells/Polycab/Nicco
Excavation in trenches in soft/loose soil n exc 1.5m wide andn. Exc1.5m deep and getting out includingforming bottom surfaces to required level or slope for taking out embeded cables,brick/pcc protective tiles and relaying new/old cable complete all specified and all as directed by engineer incharge.
M&L sand cushioningng (drysand) to under ground cable for cable protection provided with layers 8cm deep before laying and 15 cm after laying the cable complete all as specified and directed.Note :- Punned thickness will be measured only.
M&L precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm.
Removal of surplus excavated soil to a distance exc 50 m but not exc in 100 m and deposited where directed at a level n'exc 50 m above the starting point complete all as specified and directed.
Returning filling in soft/ loose soil in trenches including spreading, leveling watering and well ramming in 25mm thick layer complete all as specified and as specified.
Supply and fixing 40 mm dia 'light grade', galvanised pipe with all fitting; laid in trenches/ passing through roads/drains alongwith cutting and making surface good with existing surface all as directed by Engr-in-charge.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers all as specified and directed by Engr-in-Charge.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers all as specified and directed by Engr-in-Charge.
Ridhi Enterprises
Supreet Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .