| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.3 L+₹47,213.23 (3.19%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹15.3 L+₹54,283.23 (3.67%)Rejected-AOC 59 ST MARY S ROAD SECUNDERABAD 500 003 | SECUNDERABAD | SECUNDERABAD | TELANGANA | 500003 | L3 | Rejected-AOC L3 | |
| 4 | L4₹15.7 L+₹92,921.23 (6.28%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹17.7 L+₹2.9 L (19.4%)Rejected-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L5 | Rejected-AOC L5 |
Tender Value
₹19.4 L
EMD Value
₹38,800
Closing Date
13 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Hakimpet
Secunderabad
REPAIRS AND REPLACEMENT OF CABLES AND MISC ITEMS IN CERTAIN PLACES AT AFS HAKIMPET UNDER GE (AF) HAKIMPET
2023_MES_603565_1
8541/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hakimpet
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Hakimpet
₹38,800
Yes
8 Sept 2023
15 Jun 2023
15 Jul 2023
15 Jun 2023
13 Jul 2023
29 Jun 2023
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in hard/dense soil for laying of cables/ for erection of poles/ for stay assembly etc complete all as specified and directed by Engineer-in-Charge.
Boaring/ drilling (horizontally ) of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 80 mm dia suitable for 0.4 mpa working pressure. all as specified and directed by Engineer in charge..
Supply and spread clean dry river sand in trenches for cushioning of cable complete all as specified and directed by Engineer-in-Charge. (Note: Punned down thickness only shall be measured for the purpose of payment)
Supply and laying sub class 'B' bricks laid dry and flat old size across the length of cable for protection of cable complete all as specified and directed.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Material and labour for 80mm dia bore tubes, 'light grade' galvanised, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed by Engineer-in-Charge.
All as per item here-in-before but of size 50mm bore.
All as per item here-in-before but of size 40mm bore.
Supply & fixing in replacement of LT PVC insulated, heavy duty aluminium conductor multi stranded, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape underground cable of 16 Sqmm, 2 core in trenches or fixed on pole/wall or drawn through pipes including suitable size Lugs & Glands etc complete all as specified and directed by Engineer-in-Charge.
All as per item here-in-before but of size 16 Sqmm, 4 core
Supply & fixing in replacement of LT XLPE insulated strip armoured multi stranded aluminium underground cable of 25 Sqmm, 4 core in trenches or fixed on pole/wall or drawn through pipes including suitable size of Lugs & Glands etc complete all as specified and directed by Engineer-in-Charge.
All as per item here-in-before but of size 35 Sqmm, 3.5 core
All as per item here-in-before but of size 120 Sqmm, 3.5 core
All as per item here-in-before but of size 150 Sqmm, 3.5 core
Dismantling & taking out LT burnt cable ends of any size from transformer/LT panel/LT feeder pillar/ street light pole box/trenches any type/size, for repair/making suitable for reconnection to cable, providing lugs to burnt end of cables, preparing fresh terminals and reconnection, fixing the removed portion of cable with transformer/in trenches/along pole/ panel/feeder pillar box, including excavation of loop & refilling complete using old bricks and sand returning filling the excavated soil complete all as specified and directed.
Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 1.50 Km and n.exc 5.00 Km etc complete all as specified.
M & L for 50 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floor finishing even and smooth with using extra cement and making impression of expanded metal, whilst concrete is green over 100 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) with and including to make the road surface making good as per existing surface etc complete all as specified and directed by the Engineer in Charge.
Repair of earth pit incl required excavation ,earth work and PCC work to make good damaged /disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B1 using 20 mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm bars at 150 mm centre to centre both ways or PVC readymade available in market with prior approval of Engr In Charge, incl supply & fixing of wire mess and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts washer complete all as specified and directed
Supply, fixing ( in replacement ) of LT Panel cubical types, connecting to electrical system & testing for out door use, made out of 2 mm thick CRCA sheet CPRI approved factory made, totaly enclosed of size not less than Box size - 600x550x300mm & supported with 4 Nos MS Angle, lugs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket & sealed for vermi proof and dust proof and mounted on PCC blocks double door type with locking arragement with handle at front and openable at front &back both side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :-
(a) High conductivity aluminium bus bar of size - 50 mm x 40mm x 5mm (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (b) Phase indication lamp, LED type(set of 3) , (c) Grouting of panel including earth work as required & PCC (1:3:6) type D-2 using 20 mm gradeded stone 2x PCC block of size, 500mm x 300 mm x 100 mm & plastering with (1:4) cement sand etc complete all as directed.
Supply, fixing ( in replacement ), of LT Panel cubical types,connecting to electrical system & testing for out door use, made out of 3 mm thick CRCA sheet CPRI approved factory made, totaly enclosed of size not less than 900x600x400mm & supported with 4 Nos MS Angle, lugs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket & sealed for vermi proof and dust proof and mounted on PCC blocks double door type with locking arragement with handle at front and openable at front &back both side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :-
(a) High conductivity aluminium busbar of size - 50mm x80mm x 8 mm) 4 Nos TPN of 400 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (b) Phase indication lamp, LED type(set of 3) , (c) MCCB 4 Pole 200 Amp 415 volt ,36 KA breaking capacity microprocessure based - 01 Nos (d) Grouting of panel including earth work as required & PCC (1:3:6) type D-2 using 20 mm gradeded stone , 2x PCC block of size, 500mm x 300 mm x 100 mm & plastering with (1:4) cement sand etc complete all as directed. Note : Drawing will be approved by Engineer-in-charge before placing order to manufacture.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp including provision of mounting pole of suitable Dia & Height all as specified & directed by Engineer-in-Charge complete.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron or steel earth lead strip 32x6 mm size upto 7.5 mtr long in single length by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 5 of SSR part I including necessary excavation in hard/dense soil and earth work GI pipe 20mm dia mediumj grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to LT panel board as indicated including testing complete all as specified and as directed.
M&L for Earth continuity GI strip 32X6 mm with saddles and fixing screws etc fixed to wall on batten/porcelain insulator or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing including breazing at each necesasry joints etc.
Checking, identifying the defect /faulty point of LT UG cable of any size using Cable fault locator machine or by mannual excavation and taking out bricks from the trench upto fault point along cable route and re-laying the same using old bricks/sand incl returning filling and making good surface after rectification of defect complete all as directed.
Material and labour for cable jointing kit for 1100 Volts grade cable for straight through joint (Heat Shrink system) complete with jointing material and accessories suitable for 3.5/4 core XLPE/PVC insulated armoured aluminium conductor cable of size 240/300 sqmm complete all as specified and directed by Engineer-in-Charge. Make: 3M/ MS Seal/Raychem RPG.
All as per item here-in-before but of size 120 sqmm to 185 sqmm. , 3.5/4 core Make: 3M/Raychem .
All as per item here-in-before but of size 3.5/4 core, 70 sqmm to 95 sqmm. Make: 3M/Raychem .
All as per item here-in-before but of size 3.5/4 core, 25 sqmm to 50 sqmm. Make: 3M/Raychem
M&L for surface excavation over the areas around the poles/feeder piller boxes/ sub stations not exceeding 15cm depth including cleaning the bushes and vegetation and leveling incl removal of surplus soil in hard/ dense soil. Note:- This Job may be repeated on the same location after three months
S&F( in replacement) Pole box three phase of size 297x 250 x 130 mm made out of 2 mm MS sheet factory made with inbuilt locking arrangement, out door type , fix to pole with suitable MS clamp comprising of alluminium busbar 16 Amp 04 Nos fixe on epoxy insulated pole and MCB 6-32 Amp 10 kA 240 volt complete all as specified and directed.
Material and labour in replacement of Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size including applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Material and labour in replacement of Stay assembly with 16mm dia stay rod and all accessories as shown in electrical plate No. 1 complete all as specified and directed by Engineer-in-Charge.
Material and Labour for spray painting with two coats of enamel paint Surfaces of any description of approved colour over one coat of red oxide metal primer after scraping thoroughly the existing corroded metal surface of the LT panel at installed position all as directed by Engineer-in-Charge.
M&L MCCB 4 Pole, current rating 250 Amp, microprocessor based, thermal setting adjustable 70%-100% breaking capacity 25kA at 415V,50Hz. Including both side spreader Make : Havells/Indoashian /L&T/ Standard.
All as per item here-in-before but of capacity 160 Amps, 36 KA. Make : Havells/L&T/Standard
All as per item here-in-before but of capacity 25-100 Amps, 16KA Make : Havells/Indoashian /L&T/ Standard.
M&L MCCB 3 Pole, current rating 350 Amp, microprocessor based, thermal setting adjustable 70%-100% breaking capacity 35kA at 415V,50Hz Including both side spreader . Make : Havells/L&T/Standard
Supply and fixing in replacement new PVC insulated, served with inner sheathed pvc tape weather proof stranded Copper conductor cable FRLS three core 4 Sqmm size for connecting from connectors to Light fittings or Over head conductor to street light fittings with connector etc complete all as specified and directed by Engineer-in-Charge.
Disconnecting, dismantling and taking out old U/S UG Cable of any type and size carefully and depositing to the store yard for further disposal all as specified and directed by the Engr-in-Charge.
Dismantling/disconnecting and taking out the following old unserviceable/defective items and keeping a side for further disposal in accordance of direction of Engr-in-Charge.
Structural steel rusted broken or damaged including old cross arms, MS clamps, bolts/nuts etc
ACSR/copper conductor out lived broken unserviceable of any type including removing binding wire from insulators/jumpers.
Old unserviceable line insulator of any type including hardware
Old GI wire of any size including gaurding,cradles,stay wires etc.
Old GI pipe of any size.
SRI SAI RAM ENTERPRISES
DWARKA PERSHAD RADHEY RAMANLAL
MS ENTERPRISES
M/S - KRUPA ELECTRICALS
Srinivash Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .