Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC F A ROAD MACHKHOWA PO PS BHARALUMUKH DIST KAMRUP M ASSAM GUWAHATI 781009 | KAMRUP METRO | ASSAM | 781009 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹26.5 L+₹27,870 (1.06%)Rejected-Finance | L2 | Rejected-Finance Other than L1 bidder | |
| 3 | L3₹28.7 L+₹2.5 L (9.50%)Rejected-Finance | L3 | Rejected-Finance Other than L1 bidder |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
14 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Shillong
HQ CWE Shillong, SE Falls, Shillong - 793011
REPAIR AND MAINTENANCE OF VARIOUS RCC OHT/RESERVOIR AT CERTAIN AREAS OF UMROI MIL STN UNDER GE UMROI.
2023_MES_607497_2
8676/UMR/E8
Open Tender
Civil Works
Item Rate
180 days
Umroi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Umroi
₹54,000
Yes
1 Dec 2023
23 Sept 2023
16 Oct 2023
23 Sept 2023
14 Oct 2023
30 Sept 2023
Amount
Material and labour for cleaning of existing water tank from inside surfaces of the tank by scraping down walls & bottom surface using steel wire brushes to remove all disputation/fungus, other micro-organisms etc. Using light hammer & wire brushes, taking out and removing sediment loose dirt/mud sludge, vegetation and other foreign materials completely from the internal and external surface of tank disposal of all the waste/spoil to a distance not exceeding 50 mtr. And washing repeatedly with acid based material, corrosion inhibitors and dispersing agents solution inside surfaces of tank with water and washing with clean water thoroughly and preparation of the surface to review new plaster complete all specified and directed.
Material and labour for dismantling/taking down old existing unserviceable cement plaster loose/unsound weaken cement concrete of any description and in any position from existing external/internal surfaces of RCC/slab/beam/columns RCC facies etc. average depth 15mm (approx. height upto 15 mtr from natural ground level) with power driven of pneumatic chisel and removal upto the approval municipal dumping ground outsides MOD land including cutting of all edges, making square shoulders of the cavities roughening the smooth surfaces, scrapping out/removing corrosion all loose/scale/rust etc from the visible reinforcement by applying rust remover and cleaning the steel reinforcement properly and then applying single component cementations on visible reinforcement surfaces to form a continuous film not less than 1mm thick and preparing the surface to receive concert of epoxy grout mortar act including providing necessary proportions, bracing and runners to relieve the members form the load coming on it including scaffolding with working platform as required and as per design and pattern including preparing the surface to match with the existing surface, complete all as specified and directed
Material and labour for applying 2 coats of polymer modified primer for steel having MuCis technology and which is a blend of Portland cements, graded fillers, corrosion inhibiting additive and re-dispersible polymers in powder form that when mixed with water forms slurry for application by brush to cover exposed reinforcement/steel surface. The product shall achieve an adhesion bond strength of 1 MPa to steel. It has got a pot life of 30 minutes @30°C. The touch-dry time shall be 10-15 minutes@ 30°C. The mixed density shall be 2.01-2.05. The water/powder ratio by weight shall be 0.3. It shall achieve coverage of 2 kg /Sq.Mtr @ 1.0mm thickness, applying on visible reinforcement surfaces to form a continuous film not less than 1mm thick complete all specified and directed.
Material and labour for providing and filling epoxy putty into RCC crack after opening up RCC cracks in V-groove manner approximate 5-10 mm wide & 5-10mm deep using mechanical cutter, properly cleaning the same to remove loose dust, dirt etc. And filling the same using three component, the solvent free, thixotropic Epoxy resin based putty having 100% solid contents mixed density of 1,6 g/cc, compressive strength-50 N/mm2, pot life of 40 minutes at 27 degree C, Drying time 8 hrs. recoatable time 24 hrs. And finishing in line and level with existing concrete surface etc. complete all as specified and directed.
Material and labour for providing and applying a blend of Portland cement, graded fillers and chemical additives which impart controlled expansion, should be ready to use and can fill convoluted voids and cracks, it should componsates shrikage at both plastic and Hardened states. W/P ratio of 0.18. Strength of 1 day to be 20N/mm2. Time of expansion to start after 20min of mixing and finish in 120 min of mixing epoxy bonding agent having mix density of 1.45 to 1.5 kg/ltr, compressive strength (BS-6319 PT 3)-25 Mpa at 7 days bond strength (ASTM C 881)-11 N/mm2 at 7 days, including all tools and tackles as per accepting officer, complete all as specified and directed.
Material and labour for repair to cracks and damaged existing surface of tank upto 15 mt height from natural ground level by structural strengthing using epoxy injection grouting, complete all as specified and directed. NOTE:- (a) Fixing of PVC nozzles in zig-zag fashion not more than 50cm C/C on surfaces on all direction as required after drilling holes in concrete fixing PVC nozzle with fast setting mortar and covering with Renderoc Plug. The size of holes shall be 20mm dia and 75mm in depth. (b) Epoxy injection grouting by using standard pressure grouting pump after mixing design and hardener to the extent TILT, till refuse to accept further grout and as per manufacturer's recommendation. (c) Cutting and flushing of nozzles with surface after completing grouting and sealing the nozzle with renderoc plug and preparing the surface to match with the existing surfaces.
Material and labour for applying 2 coats of two component amine cured epoxy mastic coating using Light brush blasting using nonmetallic abrasive leaving a clean, rough and even pattern. it should be based on a 100% epoxy formulation and contains no solvents or water diluents. Apply two coats with brush or squeeze to the existing surface, working well into the substrate. It should achieve Compressive Strength of >70 MPa after 14days, having pot life, minutes at 27°C, 100 g >40 mass, complete all specified and directed.
Material and labour for providing and fixing welded MS wire mesh weighing not less than 1 kg/sqmt on the prepared surface which should be cleaned and should be removed from dirt, fungus and all foreign material, complete all specified and directed.
Material and labour for providing and spraying white, pigmented, wax based dispersion concrete curing compound incorporating a special alkali reactive emulsion breaking system compound (comply with ASTM C309-90) over the plastered surface. This impervious film prevents excessive water evaporation which in turn permits more efficient cement hydration, thus reducing shrinkage and increasing durability. It shall have a specific gravity of 1.02 and the minimum application temperature shall be 10°C and shall have a coverage of 8-10m²/litre /coat complete all as specified and directed.
Material and labour for applying 2 coats of waterproofing and protective coating using Industrial with Mucis properties - High performance elastomeric cementitious Non-toxic waterproofing coating complies to ASTM D4541, ASTM C836,DIN 1048p.5,ASTM D412 having Shore Hardness 'D' Scale =20, Non Volatile, Low Temperature Flexibility Adhesion to concrete > 2.5 N/mm2, Pass permeability Test, Tensile Strength 2 0.4 Mpa, Elongation 220%, Coating to be applied after proper curing of screed, mixing using slow speed electric drill and application of 2 coats complete all specified and directed.
Material and labour for applying 2 coats of hygienic coating on inner walls & floors/bottoms OHT using-2 part Solvent free epoxyresin coating for Lining & potable water retaining structures having 100% solid contents, approved by CFTRI (USFDA-175.300) and complies to ASTM D 2370, etc, non-toxic cured film meets requirements as per IS 9883:1981. Coating to be applied after proper surface preparation to remove loose dust, dirt etc. cleaning, mixing using slow speed electric drill and application of 2 coats at 300 microns DFT complete all specified and directed.
Material and labour for providing and applying 50mm thick micro concrete, single component cement based free flowing grout with 10 mm washed aggregates; The grout shall be having non shrink property and a positive expansion of up to min 1% in the plastic state and a flowability of 3 M at head of 250 mm for a gap width of 50 mm, developing a compressive strength of 25 MPa in 1 day & 60 MPa in 28 days, shall not bleed or segregate, having a minimum pot life of 20 minutes after which the expansion shall start, shall be also developing a flexural strength of Minimum 10 MPa & bond strength of 10 MPa, It shall have resistance to dynamic loads and specimens shall not get damaged /cracked on being subjected to alternate loads of 5 MPa to 25 MPa @ 500 Cycles per minute for minimum 2 Mio cycles, It shall be chloride free and creep resistant, with epoxy bonding agent of Thermax Ltd /SNI Infra/cipy polyurethane having mix density of 1.45 to 1.5 kg/ltr, compressive strength (BS-6319 PT 3)-40 MPa at 7 days bond strength (ASTM-C 881)-11 MPa at 7 days having an overlay time of 3 hrs at 30°C pouring cementitious grout into the formwork using suitable arrangement or if required using pumping device for and the bottom shuttering after 7 days ensuring proper bond between the cementitious grout and existing concrete substrate etc including all tools and tackles as per accepting officer, complete all specified and directed.
Material and labour for application of Water based acrylic polymer primer cum sealer coating on prepared surface having high performance copolymer emulsion, formulated to achieve specific performance characteristics that shall dry to a transparent finish and supplied as a single component white liquid to exposed concrete or masonry surface after proper surface preparation, cleaning of dust, dirt etc. The system shall form a film and shall have excellent water retention after film formation. It shall have coverage @8-10 sqm/lit/coat on prepared surface complete all specified and directed.
Material and labour for providing and applying two coats of water based Aliphatic acrylate - Anti-Carbonation coating for concrete surfaces over a coat of acrylic polymer primer. The coating to be applied on surface shall be liquid applied highly durable waterproof coating system for surface, based on high quality acrylic emulsion, functional filler, sunlight stable pigment and quality fungicides. It shall have properties that provide features like crack bridging ability, breathability, flexibility & exterior durability and resists micro- organism growth. It shall cover hairline cracks up to 0.5 mm effectively. It shall have excellent crack bridging ability and shall bridge cracks up to 2 mm width. The elongation at break is approx. 220 %. The tensile strength is 0.7 Mpa. It has a hardness shore 'A' scale of 80, with an adhesion strength of 3.4 Mpa. The coating is UV resistant, algae and fungus resistant, and has a water vapor permeability of 40 gm/m³/day and a crack bridging ability of 1- 2 mm. The coating must be applied with temperature above 5°C and below 45°C. The coating shall be applied in two coats of by roller or brush application at the interval of 4-6 hours. Allow applied coating to dry or cure for 7 days. Before applying coating one coat of Water based Acrylic polymer primer cum sealer coating for concrete surfaces primer cum sealer must be applied, complete all specified and directed.
Material and labour for drilling hole chemical anchoring of reinforcement on existing columns/chajja/beams with Hilti HIT-HY 70, minimum hole depth 100mm, steel bar 12mm dia and drill bit dia 14mm, complete all as specified and directed. Make: HT-V-R-M12x150 of Hilti
Material and labour for MS TMT bars 8mm dia and over as in reinforcement cut to length, bent to shape required including cranking, bendings spirally for hooping for column, hooking ends & binding & binding with and including MS annealed wire not less than 0.9 mm dia complete all as specified and directed.
Material and labour for form work to sides and soffits of lintels, beams, columns, shelves, chajjas including overhangs etc for fair finished flat surface, complete all as specified and directed.
Material and labour for treating the existing pipe penetrations using non-shrink, free flowing, cementitious grout. The compressive strength of the grout must exceed 50 N/mm2 at 7 days and 60 N/mm2 at 28 days. The flexural strength of grout must exceed 9N/mm2 @ 28 days. Fresh wet density of the mixed grout must exceed 2150 kg/m3. Further flashing the area using solvent based UV resistant polyurethane based waterproofing material having minimum tensile strength on 4 N/mm2 and minimum elongation of 800% complete all as specified and directed.
M/s Harjas Construction & Waterproofing Co
ANZ CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .